RESUMO
BACKGROUND: Transcatheter aortic valve implantation is an established, highly effective procedure in selected patients with severe degenerative aortic valve stenosis at high risk for conventional surgery. CASE PRESENTATION: We report a case of a 74-year-old Caucasian man who had an acute left main occlusion after transcatheter implantation of balloon-expandable valve prosthesis, followed by coronary intervention with successful recanalization. CONCLUSIONS: Acute coronary occlusion is a rare life-threatening complication of transcatheter aortic valve implantation that is poorly predictable and requires immediate diagnosis and treatment.
Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Oclusão Coronária/etiologia , Oclusão Coronária/cirurgia , Oclusão Coronária/terapia , Oclusão Coronária/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Angiografia Coronária , Intervenção Coronária PercutâneaRESUMO
This report describes a hybrid intervention addressing left circumflex artery occlusion during minimally invasive mitral valve repair. By using a radiopaque Cor-Knot device (LSI Solutions), targeted removal of occluding sutures was achieved, circumventing sternotomy and coronary artery bypass. Real-time coronary angiography provided assessment of procedural success during surgical revision in a hybrid operating room.
Assuntos
Oclusão Coronária , Procedimentos Cirúrgicos Minimamente Invasivos , Insuficiência da Valva Mitral , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Oclusão Coronária/cirurgia , Oclusão Coronária/etiologia , Oclusão Coronária/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Masculino , Angiografia Coronária , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Feminino , Complicações Pós-Operatórias/etiologia , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/efeitos adversosRESUMO
BACKGROUND: Although occlusion of the right coronary artery (RCA) is common in the remote stages of Kawasaki disease, revascularization of the RCA is challenging in children and is usually managed by observation without intervention. METHODS: Using adenosine-stress 13N-ammonia myocardial perfusion positron emission tomography, we evaluated coronary circulation in 14 patients (12 males) with RCA occlusion to identify ischemia (myocardial flow ratio < 2.0) in the RCA region and examined hemodynamics, cardiac function, and coronary aneurysm diameter. These variables were also compared in patients with/without RCA segmental stenosis (SS). RESULTS: There were five cases of ischemia in the RCA region. RCA myocardial blood flow (MBF) at rest was higher in patients with ischemia than in those without ischemia, but the difference was not significant (1.27 ± 0.21 vs. 0.82 ± 0.16 mL/min/g, p = 0.2053). Nine patients presented with RCA SS, and age at onset of Kawasaki disease tended to be lower in those with SS. The maximum aneurysm diameter of RCA was significantly smaller in patients with SS (10.0 ± 2.8 vs. 14.7 ± 1.6, p = 0.0239). No significant differences in other variables were observed between patients with/without ischemia and SS. CONCLUSIONS: At rest, MBF in the RCA region was relatively well preserved, even in patients with RCA occlusion, and there was no progressive deterioration in cardiac function. Adenosine stress showed microcirculatory disturbances in only half of the patients, indicating that it is reversible in children with Kawasaki disease.
Assuntos
Amônia , Circulação Coronária , Síndrome de Linfonodos Mucocutâneos , Imagem de Perfusão do Miocárdio , Radioisótopos de Nitrogênio , Tomografia por Emissão de Pósitrons , Humanos , Síndrome de Linfonodos Mucocutâneos/complicações , Síndrome de Linfonodos Mucocutâneos/fisiopatologia , Síndrome de Linfonodos Mucocutâneos/diagnóstico por imagem , Masculino , Feminino , Amônia/sangue , Tomografia por Emissão de Pósitrons/métodos , Criança , Pré-Escolar , Imagem de Perfusão do Miocárdio/métodos , Oclusão Coronária/etiologia , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/fisiopatologia , Aneurisma Coronário/etiologia , Aneurisma Coronário/diagnóstico por imagem , Aneurisma Coronário/fisiopatologia , Adolescente , Lactente , HemodinâmicaAssuntos
Estenose da Valva Aórtica , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Oclusão Coronária/prevenção & controle , Oclusão Coronária/etiologia , Oclusão Coronária/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Masculino , Próteses Valvulares Cardíacas/efeitos adversos , Angiografia CoronáriaRESUMO
Cardiovascular disease (CVD) constitutes the most common cause of death worldwide. In Europe alone, approximately 4 million people die annually due to CVD. The leading component of CVD leading to mortality is myocardial infarction (MI). MI is classified into several types. Type 1 is associated with atherosclerosis, type 2 results from inadequate oxygen supply to cardiomyocytes, type 3 is defined as sudden cardiac death, while types 4 and 5 are associated with procedures such as percutaneous coronary intervention and coronary artery bypass grafting, respectively. Of particular note is type 1, which is also the most frequently occurring form of MI. Factors predisposing to its occurrence include, among others, high levels of low-density lipoprotein cholesterol (LDL-C) in the blood, cigarette smoking, chronic kidney disease (CKD), diabetes mellitus (DM), hypertension, and familial hypercholesterolaemia (FH). The primary objective of this review is to elucidate the issues with regard to type 1 MI. Our paper delves into, amidst other aspects, its pathogenesis, risk assessment, diagnosis, pharmacotherapy, and interventional treatment options in both acute and long-term conditions.
Assuntos
Infarto do Miocárdio , Placa Aterosclerótica , Humanos , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/patologia , Placa Aterosclerótica/patologia , Oclusão Coronária/etiologia , Oclusão Coronária/complicações , Animais , Fatores de RiscoRESUMO
Coronary artery obstruction is a rare complication of transcatheter aortic valve replacement (TAVR). This risk increases in TAVR-valve-in-valve procedure. Several anatomic risk factors were described in many studies to identify the predictive elements of coronary artery occlusion on computed tomography cardiac scan. Rescue percutaneous coronary intervention was the first approach described to treat this complication with a high mortality rate. Later on, preventive chimney stenting technique was evaluated and results showed that is a safe and effective strategy but it leads to a difficult coronary access later. New preventive techniques are being evaluated recently (Basilica and Shorctut).
Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Angiografia Coronária/métodos , Oclusão Coronária/cirurgia , Oclusão Coronária/diagnóstico , Oclusão Coronária/etiologia , Saúde Global , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/efeitos adversos , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Medição de Risco , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversosAssuntos
Estenose da Valva Aórtica , Valva Aórtica , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Oclusão Coronária/diagnóstico , Oclusão Coronária/etiologia , Oclusão Coronária/cirurgia , Angiografia Coronária , Idoso de 80 Anos ou mais , Feminino , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Masculino , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Idoso , Resultado do TratamentoRESUMO
Transcatheter aortic valve implantation (TAVI) with commissural alignment aims to limit the risk of coronary occlusion and maintain good coronary access. However, due to coronary origin eccentricity within the coronary cusp, coronary-commissural overlap (CCO) may still occur. TAVI using coronary alignment, rather than commissural alignment, may further improve coronary access. To compare rates of CCO after TAVI using commissural versus coronary alignment methodology. Cardiac CT scans from 102 patients with severe (tricuspid) aortic stenosis referred for TAVI were analysed. Native cusp asymmetry and coronary eccentricity were defined and used to simulate TAVI using commissural versus coronary alignment. Rates of optimal coronary alignment (< 10° from cusp centre) and severe misalignment (< 15° from coronary-commissural overlap) were compared. Additionally, the impact of valve misalignment during implantation was assessed. The native right coronary artery (RCA) origin was 15.8° (9.5 to 24°) closer to the right coronary cusp/non-coronary cusp (RCC-NCC) commissure than the centre of the right coronary cusp. The native left coronary artery (LCA) origin was 4.5° (0 to 11.5°) closer to the left coronary cusp/non-coronary cusp (LCC-NCC) commissure than the centre of the left coronary cusp (p < 0.01). Compared to commissural alignment, coronary alignment doubled the proportion of optimally-aligned RCAs (62/102 [60.8%] vs. 31/102 [30.4%]; p < 0.001), without a significant change in optimal LCA alignment (62/102 [60.8% vs. 74/102 [72.6%]; p = 0.07). There were no cases of severe misalignment with either strategy. Simulating 15° of valve misalignment resulted in severe RCA compromise risk in 7/102 (6.9%) of commissural alignment cases, compared to none using coronary alignment. Fluoroscopic projection was similar with both approaches. Coronary alignment resulted in a 2-fold increase of optimal TAVI positioning relative to the RCA ostium when compared to commissural alignment without impacting the LCA. Use of coronary alignment rather than commissural alignment may improve coronary access after TAVI and is less sensitive to valve rotational error, particularly for the right coronary artery.
Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Oclusão Coronária , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Masculino , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Feminino , Idoso , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Oclusão Coronária/fisiopatologia , Oclusão Coronária/terapia , Idoso de 80 Anos ou mais , Resultado do Tratamento , Estudos Retrospectivos , Medição de Risco , Valor Preditivo dos Testes , Vasos Coronários/diagnóstico por imagem , Próteses Valvulares Cardíacas , Tomografia Computadorizada MultidetectoresRESUMO
Coronary obstruction (CO) is a rare but critical complication of transcatheter aortic valve implantation. It is associated with significant morbidity and mortality. This comprehensive review elucidates the evolving landscape of CO risk assessment and management strategies in the contemporary era of transcatheter aortic valve implantation. Drawing upon recent advances in computed tomography angiography, we delve into the nuanced evaluation of anatomic parameters crucial for predicting CO risk. Furthermore, this review explores the utility of interventional and surgical techniques, including chimney stenting and leaflet modification systems, in mitigating CO complications. In summary, this review serves as a practical guide for clinicians navigating the complexities of CO prevention and management in the evolving landscape of transcatheter aortic valve implantation, with the goal of optimizing patient outcomes and ensuring procedural success.
Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Oclusão Coronária/terapia , Resultado do Tratamento , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Medição de Risco , Stents , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Angiografia Coronária , Próteses Valvulares Cardíacas , Angiografia por Tomografia ComputadorizadaRESUMO
An 86-year-old female with history of surgical aortic valve replacement presented with clinical signs of heart failure. Echocardiography revealed a reduction in left ventricular systolic function and severe bioprosthetic aortic valve dysfunction. This is the first reported case of valve-in-valve transcatheter aortic valve replacement with concomitant undermining iatrogenic coronary obstruction with radiofrequency needle procedure in a surgical bioprosthetic valve.
Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Doença Iatrogênica , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Ablação por Cateter/efeitos adversos , Falha de Prótese , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/terapia , Agulhas , Função Ventricular Esquerda , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Oclusão Coronária/terapia , Oclusão Coronária/fisiopatologia , Angiografia CoronáriaRESUMO
Transcatheter heart valve (THV) procedures require careful planning and consideration to prevent coronary artery obstruction (CAO), which poses a significant and potentially life-threatening condition, especially in patients undergoing valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR). Despite identifying predictors of CAO and utilization of computed tomography and inputting THV features, a significant uncertainty remains in predicting CAO. The ShortCut™ device (Pi-Cardia, Rehovot, Israel) was purposefully designed to modify the leaflets in patients undergoing TAVR, especially prior to ViV procedures, to overcome the risk for CAO. This review aims to detail the device's objectives, structure, procedural steps, the available clinical data, and future directions for its intended utilization in the structural arena for the prevention of CAO.
Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Oclusão Coronária , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Resultado do Tratamento , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/prevenção & controle , Oclusão Coronária/etiologia , Oclusão Coronária/terapia , Fatores de Risco , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologiaRESUMO
BACKGROUND: Shockwave intravascular lithotripsy (S-IVL) is widely used during percutaneous coronary intervention (PCI) of calcified coronary arteries. Ventricular capture beats during S-IVL are common but arrhythmias are rare. CASE PRESENTATION: A 75-year-old woman was scheduled for PCI to a short, heavily calcified chronic total occlusion of the right coronary artery. After wiring of the occlusion, S-IVL was used to predilated the calcified stenosis. During S-IVL, the patient developed ventricular fibrillation twice. CONCLUSION: To our knowledge, this is only the second reported case of VF during S-IVL. Although very rare, it is important to be aware of this potential and serious complication.
Assuntos
Litotripsia , Intervenção Coronária Percutânea , Calcificação Vascular , Fibrilação Ventricular , Humanos , Idoso , Feminino , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/terapia , Fibrilação Ventricular/fisiopatologia , Litotripsia/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Calcificação Vascular/etiologia , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Oclusão Coronária/terapia , Oclusão Coronária/fisiopatologia , Angiografia CoronáriaRESUMO
Coronary obstruction during transcatheter aortic valve replacement (TAVR) poses a significant threat, prompting a closer examination of prevention and bailout strategies. Following TAVR deployment with a coronary artery obstruction complication and recognizing the complexities involved in engaging the left main coronary artery through TAVR cells. This case introduces the "Ping-pong" technique using a second guide catheter. When faced with difficulty in engaging the catheter through TAVR cells, an innovative solution is proposed. Inserting a wire into the valsalva and utilizing a rapid inflate-deflate balloon maneuver successfully facilitates catheter access into the left main, offering a promising intervention for challenging scenarios. In conclusion, this study emphasizes the severe implications of coronary obstruction during TAVR. The innovative "Ping-pong" technique and rapid inflate-deflate balloons emerge as valuable interventions, showcasing their potential in challenging catheter engagement scenarios. These insights offer a promising avenue for enhancing patient outcomes in TAVR procedures.
Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Oclusão Coronária/terapia , Oclusão Coronária/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Idoso de 80 Anos ou mais , Cateteres Cardíacos , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Angiografia Coronária , Masculino , FemininoAssuntos
Estenose da Valva Aórtica , Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Resultado do Tratamento , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Calcinose/fisiopatologia , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Oclusão Coronária/etiologia , Idoso de 80 Anos ou mais , Masculino , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Angiografia Coronária , Idoso , Feminino , Próteses Valvulares Cardíacas , Índice de Gravidade de DoençaAssuntos
Doença das Coronárias , Oclusão Coronária , Corpos Estranhos , Humanos , Vasos Coronários/diagnóstico por imagem , Resultado do Tratamento , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Oclusão Coronária/terapia , Corpos Estranhos/complicações , Corpos Estranhos/diagnóstico por imagem , Angiografia CoronáriaRESUMO
BACKGROUND: Coronary obstruction (CO) is a potentially life-threatening complication of transcatheter aortic valve replacement (TAVR). Chimney stenting or leaflet laceration with transcatheter electrosurgery (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction [BASILICA]) are 2 techniques developed to prevent CO. OBJECTIVES: The aim of the present study was to compare periprocedural and 1-year outcomes of chimney and BASILICA in TAVR patients at high risk of CO. METHODS: This multicenter observational registry enrolled consecutive TAVR patients at high risk of CO, undergoing either preventive chimney stenting or BASILICA. Clinical success was defined as successful performance of the chimney or BASILICA technique without clinically relevant ostial CO. The primary endpoint was major adverse cardiovascular events, a composite of death, myocardial infarction, stroke, or unplanned target lesion coronary revascularization at 1 year. RESULTS: A total of 168 patients were included: 71 (42.3%) received chimney stenting, and 97 (57.7%) underwent BASILICA. Patients undergoing BASILICA had higher preprocedural risk of CO, as indicated by lower sinotubular junction height (18.2 ± 4.8 mm vs 14.8 ± 3.4 mm; P < 0.001) and diameter (28.2 ± 4.5 vs 26.8 ± 3.4; P = 0.029). Rates of periprocedural complications were similar between the 2 groups. Clinical success was 97.2% and 96.9% in chimney and BASILICA, respectively (P = 0.92). At 1-year follow-up, the cumulative incidence of major adverse cardiovascular events was 18.7% (95% CI: 11%-30.6%) in the chimney group and 19.9% (95% CI: 12.1%-31.5%) in the BASILICA group (log-rank P = 0.848), whereas chimney was associated with a numerically higher cardiovascular mortality than BASILICA (6.7% vs 1.3%; log-rank P = 0.168). CONCLUSIONS: Chimney stenting and BASILICA effectively prevent TAVR-induced acute CO. Both techniques seem to have comparable acceptable periprocedural and 1-year outcomes.
Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Próteses Valvulares Cardíacas , Lacerações , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Lacerações/complicações , Lacerações/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Oclusão Coronária/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Desenho de PróteseRESUMO
BACKGROUND: Coronary artery obstruction after percutaneous aortic replacement is a complication with high short-term mortality secondary to the lack of timely treatment. There are various predictors of coronary obstruction prior to valve placement such as the distance from the ostia, the degree of calcification, the distance from the sinuses; In such a situation some measures must be taken to prevent and treat coronary obstruction. CASE PRESENTATION: An 84-year-old male, with severe aortic stenosis and high surgical risk, who was treated with TAVR. However, during the deployment of the valve he presented hemodynamic instability secondary to LMCA obstruction. The intravascular image showed obstruction of the ostium secondary to the displacement of calcium that he was successfully treated with a chimney stent technique. CONCLUSIONS: The high degree of calcification and the left ostium near the annulus are conditions for obstruction of the ostium at the time of valve release; In this context, provisional stenting prior to TAVR in patients at high risk of obstruction should be considered as a safe prevention strategy to achieve the success of the procedure.
Assuntos
Estenose da Valva Aórtica , Calcinose , Oclusão Coronária , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Vasos Coronários/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Oclusão Coronária/etiologia , Calcinose/complicações , Calcinose/cirurgia , Estenose da Valva Aórtica/complicações , Desenho de PróteseRESUMO
BACKGROUND: Guide catheter extensions (GCEs) increase support and facilitate equipment delivery, but aggressive instrumentation may be associated with a higher risk of complications. AIM: Our aim was to assess the impact of GCEs on procedural success and complications in patients submitted to chronic total occlusion (CTO) percutaneous coronary intervention (PCI). METHODS: We analyzed data from the multicenter LATAM CTO Registry. Procedural success was defined as <30% residual stenosis and TIMI 3 distal flow. Major adverse cardiac and cerebrovascular events (MACCE) was defined as the composite of all-cause death, myocardial infarction, target vessel revascularization, and stroke. Propensity score matching (PSM) was used to compare outcomes with and without GCE use. RESULTS: From August 2010 to August 2021, 3049 patients were included. GCEs were used in 438 patients (14.5%). In unadjusted analysis, patients in the GCE group were older and had more comorbidities. The median J-CTO score and its components were higher in the GCE group. After PSM, procedural success was higher with GCE use (87.7% vs. 80.5%, p = 0.007). The incidence of coronary perforation (odds ratio [OR]: 1.46, 95% confidence interval [CI]: 0.78-2.71, p = 0.230), bleeding (OR: 1.99, 95% CI: 0.41-2.41, p = 0.986), in-hospital death (OR: 1.39, 95% CI: 0.54-3.62, p = 0.495) and MACCE (OR: 1.07, 95% CI: 0.52-2.19, p = 0.850) were similar in both groups. CONCLUSION: In a contemporary, multicenter cohort of patients undergoing CTO PCI, GCEs were used in older patients, with more comorbidities and complex anatomy. After PSM, GCE use was associated with higher procedural success, and similar incidence of adverse outcomes.
Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Idoso , Humanos , Catéteres , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Oclusão Coronária/etiologia , Mortalidade Hospitalar , Intervenção Coronária Percutânea/efeitos adversos , Resultado do TratamentoRESUMO
BACKGROUND: Percutaneous coronary interventions (PCI) of chronic total occlusions (CTO) have reached high procedural success rates thanks to dedicated equipment, evolving techniques, and worldwide adoption of state-of-the-art crossing algorithms. AIMS: We report the contemporary results of CTO PCIs performed by a large European community of experienced interventionalists. Furthermore, we investigated the impact of different risk factors for procedural major adverse cardiac and cerebrovascular events (MACCE) and trends of employment of specific devices like dual lumen microcatheters, guiding catheter extensions, intravascular ultrasound and calcium-modifying tools. METHODS: We evaluated data from 8,673 CTO PCIs included in the European Registry of Chronic Total Occlusion (ERCTO) between January 2021 and October 2022. RESULTS: The overall technical success rate was 89.1% and was higher in antegrade as compared with retrograde cases (92.8% vs 79.3%; p<0.001). Compared with antegrade procedures, retrograde procedures had a higher complexity of attempted lesions (Japanese CTO [J-CTO] score: 3.0±1.0 vs 1.9±1.2; p<0.001), a higher procedural and in-hospital MACCE rate (3.1% vs 1.2%; p<0.018) and a higher perforation rate with and without tamponade (1.5% vs 0.4% and 8.3% vs 2.1%, respectively; p<0.001). As compared with mid-volume operators, high-volume operators had a higher technical success rate in antegrade and retrograde procedures (93.4% vs 91.2% and 81.5% vs 69.0%, respectively; p<0.001), and had a lower MACCE rate (1.47% vs 2.41%; p<0.001) despite a higher mean complexity of the attempted lesions (J-CTO score: 2.42±1.28 vs 2.15±1.27; p<0.001). CONCLUSIONS: The adoption of different recanalisation techniques, operator experience and the use of specific devices have contributed to a high procedural success rate despite the high complexity of the lesions documented in the ERCTO.
Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Oclusão Coronária/cirurgia , Oclusão Coronária/etiologia , Angiografia Coronária , Fatores de Risco , Europa (Continente) , Sistema de Registros , Doença CrônicaRESUMO
A 37-year-old man with a history of Kawasaki disease presented with total occlusion of the right coronary artery. The patient underwent percutaneous coronary intervention (PCI) with excimer laser coronary angioplasty (ELCA) and plain old balloon angioplasty (POBA). Three months after PCI, a coronary aneurysm with restenosis was detected at the PCI site, and PCI was performed again using a small balloon. The aneurysm healed three months after the second PCI procedure. This is the first report describing the long-term outcome after an aneurysm caused by PCI with ELCA and POBA.