Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
3.
Am J Ophthalmol ; 227: 245-253, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33823160

RESUMO

PURPOSE: The intent of this study was to determine the diagnostic accuracy of several diagnostic tests for age-related macular degeneration (AMD), diabetic retinopathy (DR), glaucoma, and cataract, as well as the proportions of patients with eye disease from each of 3 enrolling clinics. DESIGN: Diagnostic accuracy study. METHODS: Patients ≥50 years old in a diabetes, thyroid, and general medicine clinic were screened using visual acuity, tonometry, and fundus photography. Photographs were graded at the point-of-screening by non-ophthalmic personnel. Participants with positive screening test results in either eye and a 10% random sample with negative results in both eyes were referred for an in-person, reference-standard ophthalmology examination. RESULTS: Of 889 participants enrolled, 229 participants failed at least 1 test in either eye, of which 189 presented for an ophthalmic examination. An additional 76 participants with completely normal screening test results were referred for examination, of which 50 attended. Fundus photography screening had the highest yield for DR (sensitivity: 67%; 95% confidence interval [CI]: 39%-87%), visual acuity screening for cataract (sensitivity: 89%; 95% CI: 86%-92%), and intraocular pressure screening for glaucoma or suspected glaucoma (sensitivity: 25%; 95% CI: 14%-40%). The burden of disease was relatively high in all 3 clinics, with at least 1 of the diseases of interest (ie, AMD, DR, glaucoma or suspected glaucoma, or cataract) detected in 25% of participants (95% CI: 17-35%) from the diabeteses clinic, 34% (95% CI: 22%-49%) from the thyroid clinic, and 21% (95% CI: 13%-32%) from the general clinic. CONCLUSIONS: Non-expert eye disease screening in health clinics may be a useful model for detection of eye disease in resource-limited settings.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Oftalmopatias/diagnóstico por imagem , Oftalmologistas/normas , Fotografação/métodos , Assistentes Médicos/normas , Idoso , Catarata/diagnóstico por imagem , Competência Clínica , Retinopatia Diabética/diagnóstico por imagem , Feminino , Glaucoma/diagnóstico por imagem , Humanos , Pressão Intraocular/fisiologia , Degeneração Macular/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Oftalmoscopia , Estudos Prospectivos , Reprodutibilidade dos Testes , Microscopia com Lâmpada de Fenda , Seleção Visual/instrumentação , Acuidade Visual/fisiologia
4.
Ophthalmology ; 128(4): 561-573, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33130144

RESUMO

PURPOSE: The increasing diabetes prevalence and advent of new treatments for its major visual-threatening complications (diabetic macular edema [DME] and proliferative diabetic retinopathy [PDR]), which require frequent life-long follow-up, have increased hospital demands markedly. Subsequent delays in patient's evaluation and treatment are causing sight loss. Strategies to increase capacity are needed urgently. The retinopathy (EMERALD) study tested diagnostic accuracy, acceptability, and costs of a new health care pathway for people with previously treated DME or PDR. DESIGN: Prospective, multicenter, case-referent, cross-sectional, diagnostic accuracy study undertaken in 13 hospitals in the United Kingdom. PARTICIPANTS: Adults with type 1 or 2 diabetes previously successfully treated DME or PDR who, at the time of enrollment, had active or inactive disease. METHODS: A new health care pathway entailing multimodal imaging (spectral-domain OCT for DME, and 7-field Early Treatment Diabetic Retinopathy Study [ETDRS] and ultra-widefield [UWF] fundus images for PDR) interpreted by trained nonmedical staff (ophthalmic graders) to detect reactivation of disease was compared with the current standard care (face-to-face examination by ophthalmologists). MAIN OUTCOME MEASURES: Primary outcome: sensitivity of the new pathway. SECONDARY OUTCOMES: specificity; agreement between pathways; costs; acceptability; proportions requiring subsequent ophthalmologist assessment, unable to undergo imaging, and with inadequate images or indeterminate findings. RESULTS: The new pathway showed sensitivity of 97% (95% confidence interval [CI], 92%-99%) and specificity of 31% (95% CI, 23%-40%) to detect DME. For PDR, sensitivity and specificity using 7-field ETDRS images (85% [95% CI, 77%-91%] and 48% [95% CI, 41%-56%], respectively) or UWF images (83% [95% CI, 75%-89%] and 54% [95% CI, 46%-61%], respectively) were comparable. For detection of high-risk PDR, sensitivity and specificity were higher when using UWF images (87% [95% CI, 78%-93%] and 49% [95% CI, 42%-56%], respectively, for UWF versus 80% [95% CI, 69-88%] and 40% [95% CI, 34%-47%], respectively, for 7-field ETDRS images). Participants preferred ophthalmologists' assessments; in their absence, they preferred immediate feedback by graders, maintaining periodic ophthalmologist evaluations. When compared with the current standard of care, the new pathway could save £1390 per 100 DME visits and between £461 and £1189 per 100 PDR visits. CONCLUSIONS: The new pathway has acceptable sensitivity and would release resources. Users' suggestions should guide implementation.


Assuntos
Pessoal Técnico de Saúde/normas , Atenção à Saúde/organização & administração , Retinopatia Diabética/diagnóstico , Edema Macular/diagnóstico , Padrão de Cuidado , Adolescente , Adulto , Procedimentos Clínicos , Estudos Transversais , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 2/complicações , Feminino , Custos de Cuidados de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Oftalmologistas/normas , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia de Coerência Óptica , Adulto Jovem
5.
Am J Ophthalmol ; 224: 292-300, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33309812

RESUMO

PURPOSE: We compared the ability of ophthalmologists to identify neovascularization (NV) in patients with proliferative diabetic retinopathy using swept-source optical coherence tomography angiography (SS-OCTA) and fluorescein angiography (FA). DESIGN: Retrospective study comparing diagnostic instruments. METHODS: Eyes with proliferative diabetic retinopathy or severe nonproliferative diabetic retinopathy and a high suspicion of NV based on clinical examination were imaged using SS-OCTA and FA at the same visit. Two separate grading sets consisting of scrambled, anonymized SS-OCTA and FA images were created. The ground truth for presence of NV was established by consensus of 2 graders with OCTA experience who did not participate in the subsequent assessment of NV in this study. The 2 anonymized image sets were graded for presence or absence of NV by 12 other graders that included 2 residents, 6 vitreoretinal fellows, and 4 vitreoretinal attending physicians. The percentage of correct grading of NV using SS-OCTA and FA was assessed for each grader and across grader training levels. RESULTS: Forty-seven eyes from 24 patients were included in this study. Overall, the mean percentage of correct NV grading was 87.8% using SS-OCTA with B-scans and 86.2% using FA (P = .92). Assessing each grader individually, there was no statistically significant asymmetry in correct grading using SS-OCTA and FA. CONCLUSIONS: Ophthalmologists across training levels were able to identify diabetic NV with equal accuracy using SS-OCTA and FA. Based on these results, SS-OCTA may be an appropriate standalone modality for diagnosing diabetic NV.


Assuntos
Retinopatia Diabética/diagnóstico , Angiofluoresceinografia , Neovascularização Retiniana/diagnóstico , Vasos Retinianos/patologia , Tomografia de Coerência Óptica , Adulto , Retinopatia Diabética/classificação , Reações Falso-Positivas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oftalmologistas/normas , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Neovascularização Retiniana/classificação , Estudos Retrospectivos , Acuidade Visual
9.
Am J Ophthalmol ; 219: 170-176, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32640253

RESUMO

PURPOSE: To examine IOP measurement disagreement between technicians and physicians and the impact of an educational intervention on the short and long-term disagreement in IOP measurement using Goldmann applanation tonometry. DESIGN: Prospective study designed to enhance measurement reliability. SETTING: A glaucoma clinic at a university hospital. StudyPopulation: 6 technicians and 2 physicians. INTERVENTION: An educational intervention was implemented for the technicians to improve IOP measurement agreement with physicians. MainOutcomeMeasures: Frequency of IOP measurement disagreement between physicians and technicians, defined as a difference in IOP of >2 or >3 mm Hg and assessed at baseline and immediately and 6 months postintervention. RESULTS: IOP was evaluated for a total of 529 eyes (physician measured mean IOP = 16.4 mm Hg [SD = 5.9]), 30 per technician-physician pair for each data collection period: baseline, immediately postintervention and 6 months postintervention. At baseline, physicians disagreed 17% and 7% of the time when measuring IOP using >2 and >3 mm Hg to define disagreement, respectively, whereas the average disagreement between technicians and physicians was 25% and 13%. Disagreement was greater at IOPs greater than 20 mm Hg. No significant changes were noted in the frequency of disagreement between technicians and physicians immediately or 6 months postintervention. CONCLUSIONS: Two physicians measuring the same patient in the same room disagreed by >2 mm Hg in 17% of patients' eyes, and this amount of disagreement was even higher when comparing physicians to certified technicians. An educational intervention did not improve agreement in IOP measurements between technicians and physicians. This highlights an important limitation of Goldmann tonometry.


Assuntos
Pessoal Técnico de Saúde/normas , Pressão Intraocular/fisiologia , Oftalmologistas/normas , Tonometria Ocular/normas , Adulto , Idoso , Pessoal Técnico de Saúde/educação , Feminino , Glaucoma/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/diagnóstico , Estudos Prospectivos , Reprodutibilidade dos Testes
11.
J Pediatr Ophthalmol Strabismus ; 57(3): 190-198, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32453853

RESUMO

PURPOSE: To facilitate the development of standardized guidelines for the surgical management of patients with pediatric traumatic cataracts by assessing current ophthalmologists' practice patterns. METHODS: This was a cross-sectional, observational, and retrospective study. A 24-question electronic survey of current practices pertaining to the surgical management of pediatric traumatic cataracts was sent to pediatric ophthalmologists worldwide. Preferences for pre-operative evaluation, surgical timing and techniques, and postoperative management were analyzed. RESULTS: Of the 56 respondents, 62.5% practiced in academic settings. Of the 49 respondents (87.5%) who performed pediatric ruptured globe repair, 41.7% would perform simultaneous cataract extraction if anterior capsular violation existed, whereas 4.1% would do so without capsular violation (P < .001). Most respondents (50.9%) would remove visually significant cataracts within 4 weeks in patients within the amblyogenic age range (P = .02), whereas 63.6% would wait longer outside the amblyogenic range. Preferences for intraocular lens selection, primary posterior capsulotomy, and timing of amblyopia therapy differed. CONCLUSIONS: Individual management practices regarding pediatric traumatic cataracts vary depending on associated globe injuries and patient age. Trends exist in surgical planning, intraoperative techniques, and visual rehabilitation methods, but no single approach has achieved complete unanimity. Therefore, further investigation into optimal timing and the extent of surgical intervention, refractive correction, and postoperative care is necessary prior to developing evidence-based guidelines for enhancing visual outcomes in this population. [J Pediatr Ophthalmol Strabismus. 2020;57(3):190-198.].


Assuntos
Extração de Catarata/normas , Catarata/etiologia , Traumatismos Oculares/complicações , Oftalmologistas/normas , Padrões de Prática Médica , Acuidade Visual , Criança , Estudos Transversais , Traumatismos Oculares/cirurgia , Feminino , Humanos , Masculino , Estudos Retrospectivos
12.
Graefes Arch Clin Exp Ophthalmol ; 258(7): 1419-1426, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32346785

RESUMO

PURPOSE: The coronavirus disease (COVID-19) pandemic has evolved into a formidable healthcare crisis. Ophthalmologists are at daily personal risk of acquiring and transmitting the virus. Implementation of official practical and protective guidelines can be challenging and is often absent. The purpose of this study was to describe the status of ophthalmology practice in Israel, at the early stages of the outbreak. METHODS: A 17-item questionnaire was distributed to ophthalmologists practicing in Israel. Data was obtained regarding demographics and clinical and surgical practice during the pandemic. RESULTS: One hundred and sixty-seven ophthalmologists completed the survey from all regions of Israel. The survey was distributed during the early stages of the outbreak. At this time, no official government guidelines were in place. Most respondents reported no reduction of elective clinic visits and surgeries and no utilization of triage questionnaires. COVID-19 guidelines were reportedly promulgated to hospital ophthalmologists but not to community and private physicians. Personal protective equipment (PPE) measures were reportedly utilized; however, many respondents often acquired them individually. A majority of respondents advocated that healthcare institutions limit clinic and surgery services to emergency services. CONCLUSION: During the critical early stages of the COVID-19 outbreak in Israel, this study emphasizes the delay in development of emergency guidelines, necessary to protect patients and ophthalmologists from this highly transmissible disease.


Assuntos
Betacoronavirus , Infecções por Coronavirus/epidemiologia , Surtos de Doenças , Transmissão de Doença Infecciosa/prevenção & controle , Serviço Hospitalar de Emergência , Oftalmologistas/normas , Pneumonia Viral/epidemiologia , Adulto , COVID-19 , Infecções por Coronavirus/transmissão , Transmissão de Doença Infecciosa/estatística & dados numéricos , Feminino , Humanos , Israel/epidemiologia , Masculino , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/transmissão , SARS-CoV-2 , Inquéritos e Questionários
13.
Ophthalmic Surg Lasers Imaging Retina ; 51(4): S15-S21, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32348530

RESUMO

BACKGROUND AND OBJECTIVE: Evaluate depth of field (DOF) and lateral resolution (LR) on digitally assisted vitreoretinal surgery (DAVS) with different camera aperture values and TV viewing distances to determine maximal optical performance. PATIENTS AND METHODS: Five retinal surgeons objectively evaluated DOF and LR at low (10×), medium (15×), and high (20×) magnification on a conventional microscope (CM) and DAVS. DAVS was evaluated at different camera apertures (30%, 50%, and 75%) and TV viewing distances (1.2 meters [m], 1.5 m, and 2.0 m). A comparison between CM and optimized DAVS values was carried out. RESULTS: On DAVS, DOF significantly increased as camera aperture size was reduced (75% to 50%, P = .022; 75% to 30%, P ≤ .001; and 50% to 30%, P = .001) and as microscope magnification was reduced (high to medium, P = .009; high to low, P ≤ .001; and medium to low, P = .002). LR significantly increased as microscope magnification was increased (low to medium, P = .010; low to high, P ≤ .001; and medium to high, P = .015) and as TV display distance decreased (2.0 m to 1.5 m, P = .019; 2.0 m to 1.2 m, P = .009; and 1.5 m to1.2 m, P = .185). When comparing optimized DAVS against CM, DOF was significantly larger on DAVS (P = .019). LR on DAVS outperformed the CM, but statistical significant was not reached (P = .185). CONCLUSIONS: The authors' study is the first to evaluate different aperture, magnification, and TV distance settings, and when optimized, DAVS can significantly outperform a CM with respect to DOF and LR. Optimized visual performance for DAVS is obtained with a 30% camera aperture and a TV viewing distance no further than 1.5 m. Maximal microscope magnification to exploit LR during macular surgery and low-to-medium magnification to increase DOF for overall vitrectomy surgery is recommended. [Ophthalmic Surg Lasers Imaging Retina. 2020;51:S15-S21.].


Assuntos
Competência Clínica , Imageamento Tridimensional/métodos , Oftalmologistas/normas , Doenças Retinianas/cirurgia , Cirurgia Assistida por Computador/métodos , Acuidade Visual , Cirurgia Vitreorretiniana/métodos , Desenho de Equipamento , Humanos
14.
Graefes Arch Clin Exp Ophthalmol ; 258(7): 1405-1410, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32266472

RESUMO

PURPOSE: The aim of this study was to compare neovascular age-related macular degeneration (nAMD) treatment outcomes between ophthalmological practices and a specialized macula clinic. METHODS: In this case series, we included 347 treatment-naïve eyes with nAMD (332 patients). All patients received intravitreal anti-VEGF treatment using ranibizumab or aflibercept at the discretion of the treating physician using a treat-and-extend protocol either by one of 28 practice-based ophthalmologists (group 1; n = 215 eyes) or at a macula clinic (group 2; n = 132 eyes) over 24 months. RESULTS: Baseline characteristics of the patients in the two groups, including age, initial BCVA (group 1 58.2 ± 18.5, group 2 60.8 ± 16.1 ETDRS letters; p = 0.32), and baseline CRT, were comparable. By end of the observation period, both groups presented similar BCVA (group 1 67.4 ± 19.3, group 2 66.8 ± 17.2 letters; p = 0.51), visual gains (group 1 7.8 ± 16.9, group 2 5.8 ± 14.4 letters; p = 0.11), CRT values (group 1 259.6 ± 80.5, group 2 277.4 ± 87.1 µm; p = 0.10), and number of injections (group 1 13.0 ± 4.5, group 2 11.6 ± 4.1 injections; p = 0.09), as well as portion of eyes with stable disease (absence of any intraretinal fluid and absence or stability of subretinal fluid and pigment epithelial detachment: group 1 78% (n = 128), group 2 75% (n = 95); p = 0.63). However, there was a significant difference regarding the number of examinations (group 1 12.8 ± 5.0, group 2 9.7 ± 3.1 visits; p = 0.0005). CONCLUSIONS: nAMD treatment delivered by practice-based ophthalmologists is reasonable regarding functional outcomes and reduces the indirect treatment burden, which is partially outweighed by significantly more clinical examinations in ophthalmological practices.


Assuntos
Macula Lutea/patologia , Oftalmologistas/normas , Ranibizumab/administração & dosagem , Receptores de Fatores de Crescimento do Endotélio Vascular/administração & dosagem , Proteínas Recombinantes de Fusão/administração & dosagem , Degeneração Macular Exsudativa/terapia , Idoso de 80 Anos ou mais , Feminino , Angiofluoresceinografia/métodos , Seguimentos , Fundo de Olho , Humanos , Injeções Intravítreas , Masculino , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Degeneração Macular Exsudativa/diagnóstico
15.
Cornea ; 39(10): 1207-1214, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32118673

RESUMO

PURPOSE: To describe the ethical attitudes of corneal surgeons and eye bank leadership toward for-profit entities in corneal donation, processing, and distribution. METHODS: Fifty postfellowship corneal surgeons practicing in the United States and 25 eye bank leaders (eg, eye bank directors, CEOs, or presidents) for the Eye Bank Association of America-accredited eye banks completed a 22-question interview, focusing on corneal donation industry changes, including the entry of for-profit institutions. RESULTS: Most participants in both study groups agreed that they have concerns with the entry of for-profit businesses into eye banking (62% corneal surgeons, 68% eye bank leadership), although physicians partnered with a for-profit corneal processor were significantly more likely to have no concerns with the entry of for-profits into eye banking than corneal surgeons partnered with a nonprofit processor (P = 0.04). The most frequently identified concerns with the entry of for-profit businesses into corneal banking were the hypothetical loss of donor trust (56% corneal surgeons, 64% eye bank leadership, P = 0.04) and the potential exploitation of donor generosity (72% corneal surgeons, 60% eye bank leadership). Qualitative theme analysis suggests that both study groups may view increased research/innovation as a potential benefit (64% corneal surgeons, 66% eye bank leadership) of for-profits in eye banking. CONCLUSIONS: Key stakeholders in eye banking do hold relevant ethical beliefs toward recent industry changes, and these attitudes should be considered in the future creation of the ethical corneal donation policy. Further research is needed to assess the attitudes of potential donors and donor families.


Assuntos
Atitude do Pessoal de Saúde , Córnea , Bancos de Olhos/ética , Instituições Privadas de Saúde/ética , Oftalmologistas/ética , Doenças da Córnea/cirurgia , Transplante de Córnea/ética , Ética Institucional , Bancos de Olhos/normas , Feminino , Inquéritos Epidemiológicos , Humanos , Liderança , Masculino , Oftalmologistas/normas , Organizações sem Fins Lucrativos/ética , Inquéritos e Questionários , Doadores de Tecidos/ética , Obtenção de Tecidos e Órgãos/ética , Estados Unidos
16.
Artigo em Inglês | MEDLINE | ID: mdl-31861457

RESUMO

To investigate the parameters of eye movement between ophthalmologists and optometrists while diagnosing digital fundus photographs, sixteen participants (eight ophthalmologists and eight optometrists) were recruited in this study. Every participant's eye movement during diagnosis of a randomized set of fundus photographs displayed on an eye tracker were recorded. Fixation metrics (duration, count and rate) and scan path patterns were extracted from the eye tracker. These parameters of eye movement and correct diagnosis score were compared between both groups. Correlation analyses between fixation metrics and correct diagnosis score were also performed. Although fixation metrics between ophthalmologists and optometrists were not statistically different (p > 0.05), these parameters were statistically different when compared between different area of interests. Both participant groups had a similar correct diagnosis score. No correlation was found between fixation metrics and correct diagnosis score between both groups, except for total fixation duration and ophthalmologists' diagnosis score of diabetic retinopathy photographs. The ophthalmologists' scan paths were simpler, with larger saccades, and were distributed at the middle region of the photographs. Conversely, optometrists' scan paths were extensive, with shorter saccades covering wider fundus areas, and were accumulated in some unrelated fundus areas. These findings indicated comparable efficiency and systematic visual search patterns between both the groups. Understanding visual search strategy could expedite the creation of a novel training routine for interpretation of ophthalmic diagnostic imaging.


Assuntos
Competência Clínica/estatística & dados numéricos , Retinopatia Diabética/diagnóstico , Movimentos Oculares , Fundo de Olho , Oftalmologistas/psicologia , Optometristas/psicologia , Fotografação/métodos , Adulto , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Oftalmologistas/normas , Optometristas/normas
17.
Optom Vis Sci ; 96(10): 751-760, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31592958

RESUMO

SIGNIFICANCE: In our intermediate-tier glaucoma care clinic, we demonstrate fair to moderate agreement in gonioscopy examination between optometrists and ophthalmologists, but excellent agreement when considering open versus closed angles. We highlight the need for increased consistency in the evaluation and recording of angle status using gonioscopy. PURPOSE: The consistency of gonioscopy results obtained by different clinicians is not known but is important in moving toward practice modalities such as telemedicine and collaborative care clinics. The purpose of this study was to evaluate the description and concordance of gonioscopy results among different practitioners. METHODS: The medical records of 101 patients seen within a collaborative care glaucoma clinic who had undergone gonioscopic assessment by two clinicians (one optometrist and either one general ophthalmologist [n = 50] or one glaucoma specialist [n = 51]) were reviewed. The gonioscopy records were evaluated for their descriptions of deepest structure seen, trabecular pigmentation, iris configuration, and other features. These were compared between clinicians (optometrist vs. ophthalmologist) and against the final diagnosis. RESULTS: Overall, 51.9 and 59.8% of angles were graded identically in terms of deepest visible structure when comparing between optometrist versus general ophthalmologist and optometrist versus glaucoma specialist, respectively. The concordance increased when considering ±1 of the grade (67.4 and 78.5%, respectively), and agreement with the final diagnosis was high (>90%). Variations in angle grading other than naming structures were observed (2.0, 30, and 3.9% for optometrist, general ophthalmologist, and glaucoma specialist, respectively). Most of the time, trabecular pigmentation or iris configuration was not described. CONCLUSIONS: Fair to moderate concordance in gonioscopy was achieved between optometrists and ophthalmologists in a collaborative care clinic in which there is consistent feedback and clinical review. To move toward unified medical records and a telemedicine model, improved consistency of record keeping and angle description is required.


Assuntos
Câmara Anterior/patologia , Glaucoma de Ângulo Fechado/diagnóstico , Glaucoma de Ângulo Aberto/diagnóstico , Gonioscopia/normas , Oftalmologistas/normas , Optometristas/normas , Adulto , Idoso , Feminino , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
19.
Ophthalmic Physiol Opt ; 39(6): 432-440, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31602674

RESUMO

PURPOSE: A vignette study to examine treatment decisions made by UK hospital optometrists in patients with neovascular age-related macular degeneration (nAMD) and the effect of optometrists' experience on agreement. METHODS: Patients with nAMD attending Manchester Royal Eye Hospital, Manchester, UK were identified as potential candidates for the case series of vignettes. The cases were chosen to reflect a varied case-mix with respect to difficulty as well as ensuring good quality of the images. Each vignette included a history summary consisting of the number of previous injections given and visual acuity measurements at baseline, the previous visit, and the current visit. Images were compiled to show baseline fundus photographs and ocular coherence tomography (OCT) images with the current visit images on which the treatment decision was to be made along with the images from the previous visit. Hospital optometrists were recruited and asked to complete the series of vignettes, deciding if treatment was required at that visit and how confident they felt with that decision. Their responses were compared to the reference standard created by a consensus of consultant ophthalmologists with a sub-speciality interest in medical retina. RESULTS: Regarding treatment decision for optometrists, the percentage correct value was 75% with the sensitivity being 75.6% (95% CI 70.1-80.3) and the specificity as 75.1% (95% CI 72.1-77.8). No statistically significant difference was found between differing levels of experience. However, there was a significant difference in confidence levels between groups. Potentially sight threatening decisions accounted for 6.4% of the optometrists' decisions, 3.5% were made with a high confidence rating suggesting no discussion with an ophthalmologist was required. CONCLUSIONS: Although the optometrists showed modest agreement with the reference standard in a series of cases that have higher than average complexity, the optometrists showed a similar amount of variability within their treatment decisions compared to the reference standard. The optometrists were therefore not inferior in their performance compared to the ophthalmologists and this can be seen as supporting evidence for their extended role within this clinical area. Experience did not have an effect on 'correct' treatment decisions although there was a statistically significant effect on increasing confidence of treatment decision.


Assuntos
Inibidores da Angiogênese/administração & dosagem , Competência Clínica , Tomada de Decisões , Hospitais , Oftalmologistas/normas , Optometristas/normas , Degeneração Macular Exsudativa/tratamento farmacológico , Humanos , Injeções Intravítreas , Curva ROC , Tomografia de Coerência Óptica , Reino Unido , Degeneração Macular Exsudativa/diagnóstico
SELEÇÃO DE REFERÊNCIAS