Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 138
Filtrar
1.
Int J Nanomedicine ; 16: 3329-3342, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34012262

RESUMO

BACKGROUND AND PURPOSE: Micro-/nano-tubes (TNTs) and micro-/nano-nets (TNNs) are the common and sensible choice in the first step of combined modifications of titanium surface for further functionalization in the purpose of extended indications and therapeutic effect. It is important to recognize the respective biologic reactions of these two substrates for guiding a biologically based first-step selection. MATERIALS AND METHODS: TNTs were produced by anodic oxidation and TNNs were formed by alkali-heat treatment. The original selective laser melting (SLM) titanium surface was set as control. Surface characterization was evaluated by scanning electron microscopy, surface roughness, and water contact angle measurements. Osteoclastogenesis and osteogenesis were measured. MC3T3-E1 cells and RAW 264.7 cells were used for in vitro assay in terms of adhesion, proliferation, and differentiation. In vivo assessments were taken on Beagle dogs with micro-CT and histological analysis. RESULTS: TNN and TNT groups performed decreased roughness and increased hydrophilicity compared with SLM group. For biological detections, the highest ALP activity and osteogenesis-related genes expression were observed in TNT group followed by TNN group (P <0.05). Interestingly, when it comes to the osteoclastogenesis, TNNs displayed lowest TRAP activity and osteoclastogenesis-related genes expression and TNTs were lower than SLM but higher than TNNs (P <0.05). BV/TV around implants was highest in TNT group after 4 weeks (P <0.05). HE, ALP and TRAP staining showed that osteogenic and osteoclastic activity around TNTs were both higher than TNNs (P <0.05). CONCLUSION: TNNs and TNTs have dual advantages in promotion of osteogenesis and inhibition of osteoclastogenesis. Furthermore, TNNs showed better capability in inhibiting osteoclast activity while TNTs facilitated stronger osteogenesis. Our results implied that TNT substrates would take advantage in early application after implantation, while diseases with inappropriate osteoclast activity would prefer TNN substrates, which will guide a biologically based first-step selection on combined modification for different clinical purposes.


Assuntos
Lasers , Nanotubos/química , Osseointegração/efeitos dos fármacos , Osseointegração/efeitos da radiação , Titânio/farmacologia , Células 3T3 , Animais , Adesão Celular/efeitos dos fármacos , Diferenciação Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Cães , Camundongos , Microscopia Eletrônica de Varredura , Osteoblastos/citologia , Osteoblastos/efeitos dos fármacos , Próteses e Implantes , Células RAW 264.7 , Propriedades de Superfície , Titânio/química
2.
Lasers Med Sci ; 35(7): 1519-1529, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32026163

RESUMO

The aim of this study was to evaluate the osseointegration of implants placed in areas grafted with different osteoconductive bone substitutes irradiated with infrared low-level laser therapy (LLLT). Fifty-six rats were randomly allocated into 4 groups: DBB, bone defects filled with deproteinized bovine bone graft (DBB); HA/TCP, bone defects filled with biphasic ceramic made of hydroxyapatite and ß-tricalcium phosphate (HA/TCP); DBB-L, bone defects filled with DBB and treated by LLLT; HA/TCP-L, bone defects filled with HA/TCP and treated by LLLT. Bone defects were performed in the tibia of each animal and filled with the different biomaterials. The grafted areas were treated with LLLT (λ 808 nm, 100 mW, ϕ ∼ 0.60 mm) in 7 sessions with 48 h between the irradiations. After the 60-day period, the implants were placed, and the animals were euthanized after 15 and 45 days. The osseointegration and bone repair in the grafted area were evaluated by biomechanical, microtomographic and histometric analyses, and the expression of some bone biomarkers was evaluated by immunohistochemistry analysis. LLLT induced higher degree of osseointegration, which was associated with the greater expression of BMP2 and OCN. LLLT performed in areas grafted with osteoconductive bone substitutes prior to implant placement improves osseointegration.


Assuntos
Regeneração Óssea/efeitos dos fármacos , Regeneração Óssea/efeitos da radiação , Substitutos Ósseos/farmacologia , Terapia com Luz de Baixa Intensidade , Osseointegração/efeitos dos fármacos , Osseointegração/efeitos da radiação , Animais , Fenômenos Biomecânicos/efeitos dos fármacos , Fenômenos Biomecânicos/efeitos da radiação , Proteína Morfogenética Óssea 2/metabolismo , Bovinos , Hidroxiapatitas/farmacologia , Processamento de Imagem Assistida por Computador , Masculino , Ratos
3.
BMC Musculoskelet Disord ; 20(1): 292, 2019 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-31208382

RESUMO

BACKGROUND: Titanium instrumentations are widely used in orthopedics; the metal bonds with bone in a process called osseointegration. Over time, hydrocarbons adhere to the instrumentation, which weakens the bone-binding ability. Ultraviolet photofunctionalization enhances the bone-binding ability of instrumentation by reducing hydrocarbons. The process has been proven effective in dentistry, but its effects in orthopedics are unverified. We aimed to determine the effect of ultraviolet photofunctionalization of titanium instrumentation used in lumbar fusion. METHODS: This was a non-randomized controlled trial. We prospectively enrolled 13 patients who underwent lumbar fusion surgery. We inserted two pure titanium cages into each intervertebral space; one cage had undergone ultraviolet photofunctionalization, while the other was untreated. The degree of osteosclerosis around both cages was then compared by measuring the densities around the cages on imaging at 2, 3, 6, and 12 months postoperatively compared with 1 month postoperatively. The carbon attachment of the titanium cages was measured using X-ray photoelectron spectroscopy. RESULTS: There was no significant difference between the degree of osteosclerosis (as assessed by the density) around the treated versus untreated cages at any timepoint. The ratio of carbon attachment of the titanium cages was only 20%, which was markedly less than the ratio of carbon attachment to titanium instrumentation previously reported in the dentistry field. CONCLUSIONS: The effect of ultraviolet photofunctionalization of titanium instrumentation in spine surgery is questionable at present. The biological aging of the titanium may be affected by differences in the manufacturing process of orthopedics instrumentation versus dentistry instrumentation. TRIAL REGISTRATION: UMIN Clinical Trials Registry (Identifier: UMIN000014103 ; retrospectively registered on June 1, 2014).


Assuntos
Interface Osso-Implante/efeitos da radiação , Osseointegração/efeitos da radiação , Fusão Vertebral/instrumentação , Titânio/efeitos da radiação , Raios Ultravioleta , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Osteosclerose/diagnóstico por imagem , Osteosclerose/prevenção & controle , Estudos Prospectivos , Estudos Retrospectivos , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos , Titânio/efeitos adversos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
4.
Int J Oral Maxillofac Implants ; 34(3): 643­650, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30892289

RESUMO

BACKGROUND AND PURPOSE: The increased use of cell phones has raised many questions as to whether their use is safe for patients with dental implants. This study aimed to assess the consequences of cell phone-emitted radiation on bone-to-implant osseointegration during the healing phase. MATERIALS AND METHODS: Twelve rabbits were grouped into three groups of four. Group 1 (control) was not exposed to electromagnetic radiation; group 2 (test) was exposed for 8 hours/day in speech mode and 16 hours/day in standby mode; and group 3 (test) was exposed for 24 hours continuously in standby mode for 3 months. Forty-eight implants were placed in tibia and femur bone of rabbits, and after 90 days the rabbits were sacrificed and bone surrounding the implant was retrieved. Histopathologic evaluations of the specimens were done using transmitted light microscope. The differences among the three groups were statistically analyzed with analysis of variance (ANOVA) and pairwise comparisons via Fisher's exact test. RESULTS: Significantly less bone-to-implant contact and bone area surrounding implant threads were found in the test groups compared to the control group. There was a significant difference in regular bone formation (P < .001) among the three groups. CONCLUSION: Implants exposed to cell phone radiation showed more inflammatory reaction when compared to the nonexposed implants, thus indicating that cellular phone overuse could affect the maturation of bone and thus delay osseointegration.


Assuntos
Prótese Ancorada no Osso , Telefone Celular , Implantes Dentários , Osseointegração/efeitos da radiação , Ondas de Rádio/efeitos adversos , Análise de Variância , Animais , Implantação Dentária Endóssea , Radiação Eletromagnética , Fêmur/efeitos da radiação , Coelhos , Exposição à Radiação/efeitos adversos , Tíbia/efeitos da radiação , Cicatrização/efeitos da radiação
5.
Oxid Med Cell Longev ; 2019: 1703709, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31929852

RESUMO

High mobility group box 1 (HMGB1) participates actively in oxidative stress damage and the latter relates closely to diabetic complications, including poor implant osseointegration. This article is aimed at investigating the effects of HMGB1 on dysfunction of bone marrow stromal cells (BMSCs) and impaired osseointegration under diabetic environment. In vitro, BMSCs were treated with normal glucose (NG), high glucose (HG), and HG+glycyrrhizin (HMGB1 inhibitor, HG+GL). Cell proliferation, osteogenic behaviors, and oxidative stress were determined. In vivo, 8-week-old Sprague-Dawley rats were categorized to control, streptozotocin-induced diabetic, and diabetic-GL groups. Rats received GL (50 mg/kg, i.p.) or vehicle treatment daily after titanium implants were planted into the tibiae. After 4 and 8 weeks, plasma lipoperoxide detection, µCT analysis, and histomorphometric evaluation were conducted. By these approaches, we demonstrated that inhibiting HMGB1 by GL significantly attenuated HG-induced upregulation of HMGB1, HMGB1 ligand receptor for advanced glycation end products (RAGE) and their interaction, relieved oxidative stress, and reversed the downregulation of osteogenic markers, resulting in improved osteogenic differentiation. In diabetic rats, GL administration suppressed the upregulation of HMGB1, attenuated the lipoperoxide, and ameliorated the impaired trabecular structure and osseointegration. Taken together, inhibiting HMGB1 can be an effective approach to relieve BMSC dysfunction and enhance osseointegration under diabetic environment.


Assuntos
Células da Medula Óssea/fisiologia , Complicações do Diabetes/metabolismo , Diabetes Mellitus Experimental/metabolismo , Proteína HMGB1/metabolismo , Células Estromais/fisiologia , Animais , Células Cultivadas , Modelos Animais de Doenças , Ácido Glicirrízico/farmacologia , Proteína HMGB1/antagonistas & inibidores , Humanos , Hiperglicemia , Osseointegração/efeitos da radiação , Estresse Oxidativo , Ratos , Ratos Sprague-Dawley , Receptor para Produtos Finais de Glicação Avançada/metabolismo
6.
Int J Oral Maxillofac Implants ; 33(5): 1098-1102, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30231097

RESUMO

PURPOSE: This study retrospectively evaluated the effects of bone density, staging strategy, implant stability, healing process, implant length, surface type, and photofunctionalization on early implant failure. MATERIALS AND METHODS: Consecutive study samples at Yokohama City University Hospital were analyzed for their early implant failure potentially influenced by patient-, surgical protocol-, and implant-related factors. Through the screening process using univariate analysis for those factors, candidate influential factors such as bone density, staging strategy, the level of initial implant stability, postoperative wound breakdown, the length of implants, the surface type of implants, and use or nonuse of photofunctionalization were selected as independent variables in forward multivariate logistic regression analysis. The odds ratio (OR) for candidate factors was calculated. RESULTS: A total of 563 implants placed in 219 patients from 2005 to 2017 were analyzed for their early implant failure. Stepwise logistic regression analysis finally identified postoperative wound breakdown (OR = 0.21) and the use of photofunctionalization (OR = 0.30) that significantly reduced the risk of early implant failure (P < .01 and P < .05, respectively). The implant failure rate was 10.0% with postoperative wound breakdown and 1.0% without it, whereas it was 4.3% without photofunctionalization and 1.3% with it. CONCLUSION: Among various patient-, surgical protocol-, and implant-related factors, the absence of postoperative wound breakdown and use of photofunctionalization significantly reduced the risk of early implant failure. It was notable that photofunctionalization, a unique, chairside measure to improve implant surfaces, was effective exclusively among implant-related factors.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Materiais Dentários/efeitos da radiação , Falha de Restauração Dentária , Osseointegração/efeitos da radiação , Terapia Ultravioleta/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Cicatrização
7.
Biomed Res Int ; 2018: 8139424, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30627574

RESUMO

BACKGROUND: Clinical data demonstrated that failure rate of titanium implant in irradiated bone was 2-3 times higher than that in nonirradiated bone and it is difficult to get the ideal results in irradiated bone. PURPOSE: The aim of the study was to investigate the effects of HBO, BMP2, VEGF165, and combined use of BMP2/VEGF165 on osseointegration and stability of titanium implant in irradiated bone. MATERIALS AND METHODS: Sixty rabbits were randomly assigned to 5 groups (control group, HBO group, VEGF165 group, BMP2 group, and BMP2/VEGF165 group) after receiving 15 Gy radiation. Implant surgery was performed on tibias eight weeks later. They were sacrificed at two or eight weeks after operation. Implant stability, calcium, and ALP activity in serum, the ratio of bone volume to total volume, the rate of bone growth, and gene expression were assessed. RESULT: There was no mortality and no implants failed during the experiment. Implant stability was significantly compromised in the control group compared to the other four experimental groups, and the BMP2/VEGF165 group had the highest implant stability. HBO, BMP2, and VEGF165 significantly increased BV/TV and the rate of bone growth, while the BMP2/VEGF165 showed the best effect among groups. The expression of RUNX2 in HBO, BMP2, and VEGF165/BMP2 group was higher than that in the VEGF165 and control groups at two weeks. The expression of OCN in HBO, BMP2, VEGF165, and VEGF165/BMP2 groups was higher than that in the control group, and the gene expression of CD31 was higher in HBO, VEGF165, and BMP2/VEGF165 groups than that in control and BMP2 groups. CONCLUSION: HBO, BMP2, and VEGF165 could increase bone formation around the implant and improved the implant stability in irradiated bone. The combination use of BMP2 and VEGF165 may be promising in the treatment of implant patients with radiotherapy.


Assuntos
Proteína Morfogenética Óssea 2/farmacologia , Substitutos Ósseos , Prótese Ancorada no Osso , Raios gama , Osseointegração , Titânio , Fator A de Crescimento do Endotélio Vascular/farmacologia , Animais , Antígenos de Diferenciação/biossíntese , Masculino , Osseointegração/efeitos dos fármacos , Osseointegração/efeitos da radiação , Coelhos , Distribuição Aleatória
8.
Acta Odontol Scand ; 76(2): 130-134, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29057714

RESUMO

BACKGROUND: Radiotherapy is a commonly used treatment modality in head and neck cancer; however, it also negatively affects healthy structures. Direct damage to oral soft and hard tissue frequently occurs with radiotherapy. In this study, we aimed to evaluate the effect of radiotherapy on bone surrounding titanium dental implants via biomechanical and molecular methods. MATERIALS AND METHODS: Fifty-four implants were inserted in the left tibiae of 18 adult male New Zealand rabbits (3 implants in each rabbit). After 4 weeks of the implant surgery, the left tibiae of 12 rabbits were subjected to a single dose of irradiation (15 Gy or 30 Gy). Four weeks after the irradiation, rabbits were sacrificed and removal torque test was done for the biomechanical evaluation. Bone morphogenetic protein-2 (Bmp-2) and fibroblast growth factor-2 (Fgf-2) expression analyses were performed with Real-time PCR. Statistical analysis was done using SPSS. RESULTS: The control group showed significantly higher removal torque value than the 15 and 30 Gy irradiation groups, and the 15 Gy irradiation group had higher removal torque value than the 30 Gy irradiation group (p < .001). The 15 Gy and 30 Gy irradiation groups had significantly lower Bmp-2 and Fgf-2 mRNA expressions than the control group (p < .001). In addition, the 30 Gy irradiation group had significantly lower Bmp-2 (p < .01) and Fgf-2 mRNA expressions (p < .001) than the 15 Gy group. CONCLUSION: Radiotherapy with 15 and 30 Gy doses can adversely affect osseointegration of implants by reducing the quality of bone and impairing the bone-to-implant contact. The mechanism of action seems to be related to alterations in Bmp-2 and Fgf-2 mRNA expressions.


Assuntos
Proteína Morfogenética Óssea 2/efeitos da radiação , Implantes Dentários , Materiais Dentários/efeitos da radiação , Titânio/química , Animais , Materiais Dentários/química , Relação Dose-Resposta à Radiação , Masculino , Osseointegração/efeitos da radiação , Coelhos , Propriedades de Superfície , Torque
9.
J Craniomaxillofac Surg ; 45(11): 1846-1853, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28935484

RESUMO

PURPOSE: Low-level laser therapy (LLLT) can increase bone metabolism, cell proliferation, and maturation, and reduce inflammation, while platelet concentrate (PC) assists bone healing process by releasing proteins and growth factors. Here, we evaluated the efficacy of combined LLLT and PC therapy in the healing of critical-size bone defects. MATERIALS AND METHODS: Calvarial critical-size defects 5 mm in diameter were made in 48 Wistar rats. Bones were removed, milled, and used as autogenous bone grafts. Animals were randomized into four groups: LP (LLLT + PC), PC, L (LLLT), and C (control, autogenous graft only). Animals were sacrificed at day 30 and 60 post-surgery. Specimens were submitted to radiographic (digital and conventional), histological, histomorphometric, and immunohistochemical analyses. RESULTS: Digital radiography was shown to be a better image analysis method compared with conventional radiography. Histological analysis demonstrated a significant difference in bone formation between animals in group L (p = 0.049) at day 60 than in other groups. Higher rates of inflammatory infiltrates and fibrosis were observed in the LP and PC groups at days 30 and 60, whereas the groups not receiving PC showed a higher rate of bone maturity. The inflammatory processes were reduced in the animals in the L group, together with new bone formation and maturation. Groups L and C had higher scores of positive osteocalcin immunostaining in bone and extracellular matrix. CONCLUSIONS: LLLT reduces inflammation and contributes to increased bone formation. PC treatment was shown to maintain connective tissue and to induce fibrosis during bone repair. Combined LLLT and PC treatment did not improve bone repair.


Assuntos
Terapia com Luz de Baixa Intensidade , Plasma Rico em Plaquetas , Crânio/fisiologia , Crânio/cirurgia , Cicatrização/efeitos da radiação , Animais , Fibrose , Processamento de Imagem Assistida por Computador , Imuno-Histoquímica , Masculino , Osseointegração/efeitos da radiação , Radiografia , Distribuição Aleatória , Ratos Wistar , Crânio/diagnóstico por imagem , Crânio/patologia
10.
J Prosthet Dent ; 118(3): 357-362, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28222880

RESUMO

STATEMENT OF PROBLEM: Despite its clinical benefits, the immediate loading protocol might have a higher risk of implant failure than the regular protocol. Ultraviolet (UV) photofunctionalization is a novel surface enhancement technique for dental implants. However, the effect of photofunctionalization under loading conditions is unclear. PURPOSE: The purpose of this animal study was to evaluate the effect of photofunctionalization on the biomechanical quality and strength of osseointegration under loaded conditions in a rat model. MATERIAL AND METHODS: Untreated and photofunctionalized, acid-etched titanium implants were placed into rat femurs. The implants were immediately loaded with 0.46 N of constant lateral force. The implant positions were evaluated after 2 weeks of healing. The strength of osseointegration was evaluated by measuring the bone-implant interfacial breakdown point during biomechanical push-in testing. RESULTS: Photofunctionalization induced hydrophilic surfaces on the implants. Osseointegration was successful in 28.6% of untreated implants and 100% of photofunctionalized implants. The strength of osseointegration in successful implants was 2.4 times higher in photofunctionalized implants than in untreated implants. The degree of tilt of untreated implants toward the origin of force was twice that of photofunctionalized implants. CONCLUSIONS: Within the limit of an animal model, photofunctionalization significantly increased the success of osseointegration and prevented implant tilt. Even for the implants that underwent successful osseointegration, the strength of osseointegration was significantly higher for photofunctionalized implants than for untreated implants. Further experiments are warranted to determine the effectiveness of photofunctionalization on immediately loaded dental implants.


Assuntos
Implantes Dentários , Osseointegração/fisiologia , Osseointegração/efeitos da radiação , Terapia Ultravioleta/métodos , Animais , Fenômenos Biomecânicos , Masculino , Modelos Animais , Ratos Sprague-Dawley , Propriedades de Superfície , Suporte de Carga
11.
Int J Oral Maxillofac Implants ; 32(1): 52-62, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28095515

RESUMO

PURPOSE: Ultraviolet (UV)-mediated photofunctionalization has earned considerable attention for the enhancement of the biologic capabilities of titanium. The effects of photofunctionalization on bone augmentation and gap closure were examined using titanium implants and mesh in a rat femur model. MATERIALS AND METHODS: An acid-etched titanium implant (4-mm length, 1-mm diameter) was placed in the gluteal tuberosity that resembles a knife-edge-like edentulous ridge. The lower half of the implant was located in a 2-mm-diameter defect created in the bone without cortical bone support; the upper half was exposed and covered with a titanium mesh to provide augmentation space. After 12 and 24 days of healing, specimens were subjected to microcomputed tomography (micro-CT)- and histology-based bone morphometry in three zones of analysis: augmentation, cortical bone-implant gap, and bone marrow. A biomechanical push-in test was performed to examine the strength of bone-implant integration. Photofunctionalization was performed by treating titanium implants and mesh with UV light for 12 minutes. RESULTS: Photofunctionalized titanium mesh and implants were hydrophilic, whereas untreated controls were hydrophobic. Bone volume was significantly greater in photofunctionalized implants and mesh than in untreated implants in all zones on days 12 and 24. Bone-to-implant contact of photofunctionalized implants was greater than that of untreated implants, not just in the bone marrow but also in the gap and augmented zones. The strength of osseointegration was three times greater for photofunctionalized implants than for untreated implants. CONCLUSION: Use of photofunctionalized titanium mesh and implants effectively enhanced vertical bone augmentation, cortical bone-implant gap closure, and osseointegration without innate bone support.


Assuntos
Osso e Ossos/efeitos dos fármacos , Implantação Dentária Endóssea/métodos , Implantes Dentários , Planejamento de Prótese Dentária , Osseointegração/efeitos dos fármacos , Titânio/farmacologia , Titânio/efeitos da radiação , Raios Ultravioleta , Animais , Interface Osso-Implante/fisiologia , Modelos Animais de Doenças , Fêmur/efeitos dos fármacos , Interações Hidrofóbicas e Hidrofílicas , Masculino , Osseointegração/efeitos da radiação , Osteoblastos/citologia , Osteoblastos/efeitos dos fármacos , Ratos , Propriedades de Superfície , Titânio/química , Microtomografia por Raio-X
12.
J Periodontal Res ; 52(3): 505-511, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27624290

RESUMO

BACKGROUND AND OBJECTIVES: The aim of this study was to evaluate the effect of radiotherapy on the osseointegration of dental implants in the tibia and the action of platelet-rich plasma (PRP) as an adjuvant therapy. MATERIAL AND METHODS: A total of 18 rabbits received two implants in each tibial epiphysis, totalizing 72 implants. The control group (group I) was composed by six rabbits and did not receive radiotherapy. The test groups (II and III) received a single dose of 1727 cGy. Group II was composed by six irradiated animals and group III by six animals that received irradiation and PRP during implant placement. The implant success rate, the bone-implant contact (BIC), and the bone volume were analyzed. RESULTS: There was no osseointegration in four of the implants, three in group II and one in group III. Total BIC was significantly higher in group I, when compared to the other groups. There was a significant difference of osteoid BIC only between irradiated animals (group II, 8.5%; group III, 4.7%; p = 0.001). On the other hand, the mineralized BIC was significantly higher in group I. Furthermore, group II had a lower mineralized BIC than group III (p = 0.002). Bone volume was higher in the control group (41.3%), followed by group III (33.4%) and II (25.1%), with differences between groups I and II (p = 0.001) and groups II and III (p = 0.022). CONCLUSIONS: The present study showed that both the bone volume and BIC were higher in the control group. However, the failure rates of the implants were low in both irradiated groups. The PRP was a positive adjuvant in the osseointegration process.


Assuntos
Implantes Dentários , Osseointegração/efeitos da radiação , Tíbia/efeitos da radiação , Animais , Implantação Dentária Endóssea/métodos , Falha de Restauração Dentária , Masculino , Coelhos , Tíbia/cirurgia , Titânio
13.
J Craniomaxillofac Surg ; 44(11): 1842-1848, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27697399

RESUMO

OBJECTIVES: The aim of this study was to compare the influence of implant surface treatment and irradiation dose on implant stability and osseointegration of 144 extraoral implants in irradiated frontal bone of minipigs. MATERIAL AND METHODS: 144 implants with 3 different surface treatments (machined, etched and HAVD-coated) were implanted in the frontal bone of 16 Göttingen minipigs. Three groups of four pigs received radiation with equivalent doses of 25, 50 and 70 Gy, and one group served as control. Resonance frequency analysis (RFA) was performed recording Implant Stability Quotients (ISQ) at implant placement and 3 months thereafter. Removal torque was measured whilst removing specific implants after 3 months. In addition, the bone-to-implant contact (BIC) was analyzed. RESULTS: Evaluation of ISQ, BIC-values showed no significant difference between the different surface treatments in irradiated and non-irradiated bone. Removal torque revealed statistically significant differences between machined and HAVD-coated implants in the irradiated bone. CONCLUSIONS: Implant stability and osseointegration, based on Removal Torque showed significant higher results for the HAVD-coated implants. No significant difference was observed between the irradiated and non-irradiated animals. This study shows that HAVD-coated extraoral implants can potentially be used for craniofacial rehabilitation in non-irradiated and irradiated bone.


Assuntos
Ossos Faciais/cirurgia , Osso Frontal/cirurgia , Osseointegração/efeitos da radiação , Próteses e Implantes , Animais , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Retenção da Prótese , Doses de Radiação , Suínos , Porco Miniatura
14.
Lasers Med Sci ; 31(9): 1789-1795, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27534769

RESUMO

The purpose of the present study is to evaluate the effects of low-level laser therapy on the osseointegration process by comparing resonance frequency analysis measurements performed at implant placement and after 30 days and micro-computed tomography images in irradiated vs nonirradiated rabbits. Fourteen male New Zealand rabbits were randomly divided into two groups of seven animals each, one control group (nonirradiated animals) and one experimental group that received low-level laser therapy (Thera Lase®, aluminum-gallium-arsenide laser diode, 10 J per spot, two spots per session, seven sessions, 830 nm, 50 mW, CW, Ø 0.0028 cm2). The mandibular left incisor was surgically extracted in all animals, and one osseointegrated implant was placed immediately afterward (3.25ø × 11.5 mm; NanoTite, BIOMET 3i). Resonance frequency analysis was performed with the Osstell® device at implant placement and at 30 days (immediately before euthanasia). Micro-computed tomography analyses were then conducted using a high-resolution scanner (SkyScan 1172 X-ray Micro-CT) to evaluate the amount of newly formed bone around the implants. Irradiated animals showed significantly higher implant stability quotients at 30 days (64.286 ± 1.596; 95 % confidence interval (CI) 60.808-67.764) than controls (56.357 ± 1.596; 95 %CI 52.879-59.835) (P = .000). The percentage of newly formed bone around the implants was also significantly higher in irradiated animals (75.523 ± 8.510; 95 %CI 61.893-89.155) than in controls (55.012 ± 19.840; 95 %CI 41.380-68.643) (P = .027). Laser therapy, based on the irradiation protocol used in this study, was able to provide greater implant stability and increase the volume of peri-implant newly formed bone, indicating that laser irradiation effected an improvement in the osseointegration process.


Assuntos
Implantação Dentária Endóssea , Lasers Semicondutores/uso terapêutico , Terapia com Luz de Baixa Intensidade/métodos , Osseointegração/efeitos da radiação , Animais , Modelos Animais de Doenças , Masculino , Mandíbula , Coelhos , Distribuição Aleatória , Microtomografia por Raio-X
15.
Implant Dent ; 25(6): 744-750, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27513161

RESUMO

OBJECTIVES: This study evaluated the effect of photofunctionalization on osseointegration under the biologically adverse conditions of aging. MATERIALS: First of all, bone marrow-derived osteoblastic cells from young (8 weeks old) and aged (15 months old) rats were biologically characterized. Then, the osteoblasts from aged rats were seeded on titanium discs with and without photofunctionalization, and assessed for initial cell attachment and osteoblastic functions. Titanium mini-implants, with and without photofunctionalization, were placed in the femur of aged rats, and the strength of osseointegration was measured at week 2 of healing. Periimplant tissue was examined morphologically and chemically using scanning electron microscopy and energy dispersive x-ray spectroscopy, respectively. RESULTS: Cells from the aged rats showed substantially reduced biological capabilities compared with those derived from young rats. The cells from aged rats showed significantly increased cell attachment and the expression of osteoblastic function on photofunctionalized titanium than on untreated titanium. In addition, the strength of osseointegration was increased by 40% in aged rats carrying the photofunctionalized implants. Robust bone formation was observed around the photofunctionalized implants with strong elemental peaks of calcium and phosphorus, whereas the tissue around untreated implants showed weaker calcium and phosphate signals than titanium ones. CONCLUSION: These in vivo and in vitro results corroboratively demonstrate that photofunctionalization is effective for enhancing osseointegration in aged rats.


Assuntos
Osseointegração/efeitos da radiação , Terapia Ultravioleta/métodos , Fatores Etários , Animais , Interface Osso-Implante/efeitos da radiação , Implantes Dentários , Fêmur/cirurgia , Masculino , Transplante de Células-Tronco Mesenquimais , Microscopia Eletrônica de Varredura , Osteoblastos/efeitos da radiação , Ratos , Ratos Sprague-Dawley , Espectrometria por Raios X , Titânio
16.
Sci Rep ; 6: 30231, 2016 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-27456818

RESUMO

Non-drug strategies based on biophysical stimulation have been emphasized for the treatment and prevention of musculoskeletal conditions. However, to date, an effective stimulation system for intracorporeal therapies has not been proposed. This is particularly true for active intramedullary implants that aim to optimize osseointegration. The increasing demand for these implants, particularly for hip and knee replacements, has driven the design of innovative stimulation systems that are effective in bone-implant integration. In this paper, a new cosurface-based capacitive system concept is proposed for the design of implantable devices that deliver controllable and personalized electric field stimuli to target tissues. A prototype architecture of this system was constructed for in vitro tests, and its ability to deliver controllable stimuli was numerically analyzed. Successful results were obtained for osteoblastic proliferation and differentiation in the in vitro tests. This work provides, for the first time, a design of a stimulation system that can be embedded in active implantable devices for controllable bone-implant integration and regeneration. The proposed cosurface design holds potential for the implementation of novel and innovative personalized stimulatory therapies based on the delivery of electric fields to bone cells.


Assuntos
Desenvolvimento Ósseo/fisiologia , Fixação Intramedular de Fraturas/métodos , Osseointegração/efeitos da radiação , Próteses e Implantes , Desenvolvimento Ósseo/efeitos da radiação , Diferenciação Celular/efeitos da radiação , Proliferação de Células/efeitos da radiação , Estimulação Elétrica , Humanos , Osseointegração/fisiologia , Propriedades de Superfície
17.
Int J Oral Maxillofac Implants ; 31(4): 776-84, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27447142

RESUMO

PURPOSE: Acid etching in conjunction with storage in an aqueous solution can induce nanostructures forming spontaneously on titanium surfaces, but an inevitable biologic degradation is suspected to accompany the evolution of nanostructures. The aim of this study was to investigate whether ultraviolet (UV) irradiation is effective to solve this problem and further enhance the bioactivity. MATERIALS AND METHODS: Surface characteristics of five groups of titanium implants (SLAnew, SLAold, modSLA, UV-SLA, and UV-modSLA) and their in vivo bone response were analyzed in this study. The surface characteristics were evaluated with contact angle measurements, scanning electron microscopy, and x-ray photon spectroscopy. A total of 160 implants (32 for each group) were inserted into the tibial metaphyses and femoral condyles of 40 rabbits. After 3 and 6 weeks, the rabbits were euthanized for removal torque tests and histomorphometric analysis. RESULTS: Spontaneously formed nanostructures were observed on water-stored surfaces with a size of approximately 15 nm in diameter, and an inevitable contamination of hydrocarbons accompanied the evolution of nanostructures. UV irradiation effectively eliminated hydrocarbon contamination that accompanied nanostructure evolution. UV-modSLA implants showed the highest removal torque value, and UV-irradiated implants exhibited higher bone-to-implant contact and bone area. CONCLUSION: UV irradiation can effectively eliminate the hydrocarbon contamination accompanying the evolution of nanostructures and further enhance the osseointegration. Nanostructures and UV treatment have combined effects in enhancing the interfacial strength between titanium and bone, while UV photofunctionalization has much more overwhelming effects on histologic and histomorphometric performance.


Assuntos
Materiais Biocompatíveis/efeitos da radiação , Implantes Dentários , Nanoestruturas/efeitos da radiação , Propriedades de Superfície/efeitos da radiação , Titânio/efeitos da radiação , Raios Ultravioleta , Animais , Interface Osso-Implante/fisiologia , Implantação Dentária Endóssea/métodos , Planejamento de Prótese Dentária , Modelos Animais de Doenças , Fêmur/cirurgia , Hidrocarbonetos/efeitos da radiação , Implantes Experimentais , Microscopia Eletrônica de Varredura , Nanoestruturas/química , Osseointegração/fisiologia , Osseointegração/efeitos da radiação , Coelhos , Torque
18.
Int J Oral Maxillofac Implants ; 31(3): 676-86, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27183088

RESUMO

PURPOSE: The objective of this study was to compare the rate of implant stability development of as-received and photofunctionalized dental implants in regular and complex cases. MATERIALS AND METHODS: Forty-nine implants (24 as-received and 25 photofunctionalized) placed in regular or complex cases (simultaneous guided bone regeneration, sinus elevation, or fresh extraction sockets) were studied. Photofunctionalization was performed by ultraviolet (UV) treatment of implants for 15 minutes using a photo device immediately prior to placement, and the generation of superhydrophilicity was confirmed. Implant stability was evaluated by measuring the implant stability quotient (ISQ) at placement (ISQ1) and at stage-two surgery (ISQ2). The rate of implant stability development was evaluated by calculating the osseointegration speed index (OSI), defined as the ISQ increase per month ([ISQ2-ISQ1]/healing time in months). The percentage of innate bone support at placement was evaluated clinically and radiographically. RESULTS: The average OSI was considerably greater for photofunctionalized implants (3.7 ± 2.9) than for as-received implants (0.0 ± 1.0). The OSI in complex cases was 4.2 ± 3.2 for photofunctionalized implants and 0.2 ± 0.9 for as-received implants. The OSI in cases with simultaneous sinus elevation was 5.5 ± 3.5 for photofunctionalized implants and 0.2 ± 1.1 for as-received implants. Photofunctionalized implants showed significantly higher ISQ2 values than as-received implants. Photofunctionalized implant ISQ2 values were greater than 60, regardless of primary stability and innate bone support at placement. In multivariate analysis including the effects of photofunctionalization, age and sex of patients, and diameter and length of implants, photofunctionalization showed the strongest influence on the OSI for both regular and complex cases, while other factors influenced the OSI only in certain conditions. CONCLUSION: Photofunctionalization accelerated the rate and enhanced the final level of implant stability development compared with as-received implants, particularly for implants placed into poor-quality bone and other complex cases. Photofunctionalization was a stronger determinant of implant stability than all the other tested implant- and host-related factors.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Materiais Dentários/efeitos da radiação , Osseointegração/efeitos da radiação , Fototerapia/métodos , Raios Ultravioleta , Adulto , Idoso , Análise de Variância , Regeneração Óssea/efeitos da radiação , Estudos de Casos e Controles , Feminino , Regeneração Tecidual Guiada , Humanos , Interações Hidrofóbicas e Hidrofílicas , Masculino , Pessoa de Meia-Idade , Osseointegração/fisiologia , Estudos Retrospectivos , Levantamento do Assoalho do Seio Maxilar , Propriedades de Superfície , Titânio/efeitos da radiação
19.
Lasers Med Sci ; 31(5): 985-9, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27126410

RESUMO

The aim of the present study was to evaluate the success rate of failed implants re-implanted after surface treatment with CO2 laser. Despite the widespread use of dental implants, there are many incidents of failures. It is believed that lasers can be applied to decontaminate the implant surface without damaging the implant. Ten dental implants that had failed for various reasons other than fracture or surface abrasion were subjected to CO2 laser surface treatment and randomly placed in the maxillae of dogs. Three failed implants were also placed as the negative controls after irrigation with saline solution without laser surface treatment. The stability of the implants was evaluated by the use of the Periotest values (PTVs) on the first day after surgery and at 1, 3, and 6 months post-operatively. The mean PTVs of treated implants increased at the first month interval, indicating a decrease in implant stability due to inflammation followed by healing of the tissue. At 3 and 6 months, the mean PTVs decreased compared to the 1-month interval (P < 0.05), indicating improved implant stability. The mean PTVs increased in the negative control group compared to baseline (P < 0.05). Independent t-test showed that the mean PTVs of treated implants were significantly lower than control group at 3 and 6 months after implant placement (P < 0.05). Based on the PTVs, re-implantation of failed implants in Jack Russell Terrier dogs after CO2 laser surface debridement is associated with a high success rate in terms of implant stability.


Assuntos
Implantação Dentária Endóssea/métodos , Retenção em Prótese Dentária , Lasers de Gás/uso terapêutico , Terapia com Luz de Baixa Intensidade/métodos , Animais , Cães , Masculino , Maxila , Osseointegração/efeitos da radiação , Distribuição Aleatória , Cicatrização
20.
J Ultrasound Med ; 35(4): 747-54, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26960802

RESUMO

OBJECTIVES: To investigate the effect of low-intensity pulsed ultrasound (US) on periimplant bone healing and osseointegration under osteoporotic conditions. METHODS: Seventy-two 12-week-old female Sprague Dawley rats received bilateral ovariectomies. Twelve weeks later, titanium implants were bilaterally placed in the proximal tibial metaphysis. The right tibia was exposed to low-intensity pulsed US (40 mW/cm2, spatial and temporal average) for 20 min/d starting the 2nd day after implantation, and the left tibia served as a control without stimulation. The rats were randomly assigned to 6 groups of 12 each according to the US duration (group 1: weeks 0­2, 280 minutes; group 2: weeks 0­4, 560 minutes; group 3: weeks 0­6, 840 minutes; group 4: weeks 0­8, 1120 minutes; group 5: weeks 0­10, 1400 minutes; group 6: weeks 0­12, 1680 minutes). At the end of the 2nd, 4th, 6th, 8th, 10th, and 12th weeks, the rats were euthanized, and bilateral tibias were harvested. Peri-implant bone volume and bone-implant contact were assessed by micro­computed tomography; the implantbone interface was assessed histologically; and implant fixation strength was determined by a removal torque test. RESULTS: Low-intensity pulsed US increased bone-implant contact at the 4th, 6th, 8th, 10th, and 12th weeks (P = .019, .017, <.001, <.001, and <.001, respectively) and periimplant bone volume at all times (P = <.001, .002, .012, .007, .005, and .010). Removal torque on the US side was improved at the 6th, 8th, 10th, and 12th weeks (P= .012, <.001, .006, and .009). Ultrasound evoked a favorable bone response in the histologic study. CONCLUSIONS: Low-intensity pulsed US might enhance new bone formation, especially at an early stage, and improve osseointegration in osteoporotic bone as an auxiliary method. However, further studies are needed to elucidate the mechanisms underlying its action.


Assuntos
Placas Ósseas , Osseointegração/fisiologia , Osteoporose/fisiopatologia , Osteoporose/terapia , Terapia por Ultrassom/métodos , Animais , Feminino , Osseointegração/efeitos da radiação , Osteoporose/diagnóstico por imagem , Ovariectomia , Ratos , Ratos Sprague-Dawley , Resultado do Tratamento , Ondas Ultrassônicas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA