Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.527
Filtrar
1.
Phys Med Biol ; 69(12)2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38776951

RESUMO

Objective.In this work, we present and evaluate a technique for performing interface measurements of beta particle-emitting radiopharmaceutical therapy agents in solution.Approach.Unlaminated EBT3 film was calibrated for absorbed dose to water using a NIST matched x-ray beam. Custom acrylic source phantoms were constructed and placed above interfaces comprised of bone, lung, and water-equivalent materials. The film was placed perpendicular to these interfaces and measurements for absorbed dose to water using solutions of90Y and177Lu were performed and compared to Monte Carlo absorbed dose to water estimates simulated with EGSnrc. Surface and depth dose profile measurements were also performed.Main results.Surface absorbed dose to water measurements agreed with predicted results within 3.6% for177Lu and 2.2% for90Y. The agreement between predicted and measured absorbed dose to water was better for90Y than177Lu for depth dose and interface profiles. In general, agreement withink= 1 uncertainty bounds was observed for both radionuclides and all interfaces. An exception to this was found for the bone-to-water interface for177Lu due to the increased sensitivity of the measurements to imperfections in the material surfaces.Significance. This work demonstrates the feasibility and limitations of using radiochromic film for performing absorbed dose to water measurements on beta particle-emitting radiopharmaceutical therapy agents across material interfaces.


Assuntos
Partículas beta , Método de Monte Carlo , Compostos Radiofarmacêuticos , Partículas beta/uso terapêutico , Compostos Radiofarmacêuticos/uso terapêutico , Compostos Radiofarmacêuticos/administração & dosagem , Radiometria/instrumentação , Radiometria/métodos , Imagens de Fantasmas , Água/química , Radioisótopos de Ítrio/uso terapêutico , Humanos
2.
Appl Radiat Isot ; 210: 111360, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38781612

RESUMO

Human activities usually have some contamination as effluents from chemical industries and radionuclides from nuclear reactors. For assessing the probable radioactive contamination in vicinity of Tehran Research Reactor, The gross alpha and beta radioactivity concentrations in soil, pine and cedar leaves and some selected fruits (fig, apple, berry and pomegranate) were investigated using an alpha/beta spectrometer during 2021-2022. Also, the concentrations of artificial and natural radionuclides in samples were investigated by the method of gamma spectroscopy. The gross alpha activity concentrations in soil, pine and cedar leaves and some selected fruits samples are from 0.05 to 0.35 Bq/gr and 0.07-0.31 Bq/gr and 0.04-0.18 Bq/gr, respectively. The gross beta activity concentrations in soil, pine and cedar leaves and some selected fruit samples are from 0.73 to 4.25 Bq/gr and 0.21-3.97 Bq/gr and 1.01-2.71 Bq/gr, respectively. Average activities concentration of natural radionuclide 232Th, 238U and 40K in soil, pine and cedar leaves and some selected fruits are 31.89-16.23-582.73 Bq/kg and 1.84-0.99-84.60 Bq/kg and 1.98-1.09-72.08 Bq/kg respectively. From artificial radionuclides, just 137Cs is recognized in soil sample and the range of 137Cs concentration in surface soils was observed to vary in the range 0.85-2.21 (Bq/kg). The result showed that the Tehran Research Reactor activities not have increased the environmental radioactivity and radiation level in the area.


Assuntos
Partículas beta , Frutas , Monitoramento de Radiação , Poluentes Radioativos do Solo , Irã (Geográfico) , Poluentes Radioativos do Solo/análise , Frutas/química , Monitoramento de Radiação/métodos , Partículas alfa , Reatores Nucleares , Urânio/análise , Contaminação Radioativa de Alimentos/análise , Radioisótopos/análise , Humanos , Folhas de Planta/química , Tório
3.
Luminescence ; 39(4): e4732, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38556715

RESUMO

In the present work, glass samples in the (100 - x)B2O3-xLi2O binary system, with x varying from 30 to 50 mol%, were prepared using the conventional melting and moulding method, with the main objective of evaluating the thermoluminescence response when exposing these materials to ultraviolet (UV) radiation. Complementary analysis based on density, optical absorption on the UV-visible region (UV-vis absorbance), Fourier transform infrared spectroscopy on the medium region, X-ray diffraction, and differential thermal analysis measurements were performed. Thermoluminescence measurements of vitreous samples showed glow curves with at least one peak with a maximum temperature of ~170°C after exposure to UV radiation in the temperature range 50-250°C. Samples were also exposed to beta radiation in the temperature range 25-275°C, also showing single peaks with a maximum temperature of ~150°C.


Assuntos
Partículas beta , Boratos , Boratos/química , Compostos de Lítio , Temperatura
4.
PET Clin ; 19(3): 307-323, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38688775

RESUMO

Targeted radionuclide therapy (TRT) has significantly evolved from its beginnings with iodine-131 to employing carrier molecules with beta emitting isotopes like lutetium-177. With the success of Lu-177-DOTATATE for neuroendocrine tumors and Lu-177-PSMA-617 for prostate cancer, several other beta emitting radioisotopes, such as Cu-67 and Tb-161, are being explored for TRT. The field has also expanded into targeted alpha therapy (TAT) with agents like radium-223 for bone metastases in prostate cancer, and several other alpha emitter radioisotopes with carrier molecules, such as Ac-225, and Pb-212 under clinical trials. Despite these advancements, the scope of TRT in treating diverse solid tumors and integration with other therapies like immunotherapy remains under investigation. The success of antibody-drug conjugates further complements treatments with TRT, though challenges in treatment optimization continue.


Assuntos
Partículas alfa , Partículas beta , Radioisótopos , Compostos Radiofarmacêuticos , Humanos , Partículas beta/uso terapêutico , Partículas alfa/uso terapêutico , Radioisótopos/uso terapêutico , Compostos Radiofarmacêuticos/uso terapêutico , Neoplasias/radioterapia , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/diagnóstico por imagem , Masculino , Lutécio/uso terapêutico , Rádio (Elemento)/uso terapêutico , Neoplasias Ósseas/radioterapia , Neoplasias Ósseas/secundário
5.
Phys Med Biol ; 69(11)2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38684165

RESUMO

Objective. This work introduces a novel approach to performing active and passive dosimetry for beta-emitting radionuclides in solution using common dosimeters. The measurements are compared to absorbed dose to water (Dw) estimates from Monte Carlo (MC) simulations. We present a method for obtaining absorbed dose to water, measured with dosimeters, from beta-emitting radiopharmaceutical agents using a custom SPECT/CT compatible phantom for validation of Monte Carlo based absorbed dose to water estimates.Approach. A cylindrical, acrylic SPECT/CT compatible phantom capable of housing an IBA EFD diode, Exradin A20-375 parallel plate ion chamber, unlaminated EBT3 film, and thin TLD100 microcubes was constructed for the purpose of measuring absorbed dose to water from solutions of common beta-emitting radiopharmaceutical therapy agents. The phantom is equipped with removable detector inserts that allow for multiple configurations and is designed to be used for validation of image-based absorbed dose estimates with detector measurements. Two experiments with131I and one experiment with177Lu were conducted over extended measurement intervals with starting activities of approximately 150-350 MBq. Measurement data was compared to Monte Carlo simulations using the egs_chamber user code in EGSnrc 2019.Main results. Agreement withink= 1 uncertainty between measured and MC predictedDwwas observed for all dosimeters, except the A20-375 ion chamber during the second131I experiment. Despite the agreement, the measured values were generally lower than predicted values by 5%-15%. The uncertainties atk = 1 remain large (5%-30% depending on the dosimeter) relative to other forms of radiation therapy.Significance. Despite high uncertainties, the overall agreement between measured and simulated absorbed doses is promising for the use of dosimeter-based RPT measurements in the validation of MC predictedDw.


Assuntos
Partículas beta , Método de Monte Carlo , Imagens de Fantasmas , Radiometria , Compostos Radiofarmacêuticos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Radiometria/instrumentação , Partículas beta/uso terapêutico , Compostos Radiofarmacêuticos/uso terapêutico , Compostos Radiofarmacêuticos/química , Radioisótopos do Iodo/uso terapêutico , Lutécio/química , Água/química , Radioisótopos
6.
Ann Surg Oncol ; 31(7): 4189-4196, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38652200

RESUMO

BACKGROUND: Radio-guided surgery (RGS) holds promise for improving surgical outcomes in neuroendocrine tumors (NETs). Previous studies showed low specificity (SP) using γ-probes to detect radiation emitted by radio-labeled somatostatin analogs. OBJECTIVE: We aimed to assess the sensitivity (SE) and SP of the intraoperative RGS approach using a ß-probe with a per-lesion analysis, while assessing safety and feasibility as secondary objectives. METHODS: This prospective, single-arm, single-center, phase II trial (NCT05448157) enrolled 20 patients diagnosed with small intestine NETs (SI-NETs) with positive lesions detected at 68Ga-DOTA-TOC positron emission tomography/computed tomography (PET/CT). Patients received an intravenous injection of 1.1 MBq/Kg of 68Ga-DOTA-TOC 10 min prior to surgery. In vivo measurements were conducted using a ß-probe. Receiver operating characteristic (ROC) analysis was performed, with the tumor-to-background ratio (TBR) as the independent variable and pathology result (cancer vs. non-cancer) as the dependent variable. The area under the curve (AUC), optimal TBR, and absorbed dose for the surgery staff were reported. RESULTS: The intraoperative RGS approach was feasible in all cases without adverse effects. Of 134 specimens, the AUC was 0.928, with a TBR cut-off of 1.35 yielding 89.3% SE and 86.4% SP. The median absorbed dose for the surgery staff was 30 µSv (range 12-41 µSv). CONCLUSION: This study reports optimal accuracy in detecting lesions of SI-NETs using the intraoperative RGS approach with a novel ß-probe. The method was found to be safe, feasible, and easily reproducible in daily clinical practice, with minimal radiation exposure for the staff. RGS might potentially improve radical resection rates in SI-NETs. CLINICAL TRIALS REGISTRATION: 68Ga-DOTATOC Radio-Guided Surgery with ß-Probe in GEP-NET (RGS GEP-NET) [NCT0544815; https://classic. CLINICALTRIALS: gov/ct2/show/NCT05448157 ].


Assuntos
Neoplasias Intestinais , Intestino Delgado , Tumores Neuroendócrinos , Octreotida , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Cirurgia Assistida por Computador , Humanos , Tumores Neuroendócrinos/cirurgia , Tumores Neuroendócrinos/patologia , Tumores Neuroendócrinos/diagnóstico por imagem , Feminino , Masculino , Estudos Prospectivos , Pessoa de Meia-Idade , Neoplasias Intestinais/cirurgia , Neoplasias Intestinais/patologia , Neoplasias Intestinais/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Idoso , Intestino Delgado/patologia , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/cirurgia , Octreotida/análogos & derivados , Adulto , Cirurgia Assistida por Computador/métodos , Compostos Organometálicos , Somatostatina/análogos & derivados , Seguimentos , Prognóstico , Partículas beta/uso terapêutico , Estudos de Viabilidade
7.
PET Clin ; 19(3): 389-399, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38679550

RESUMO

Prostate cancer is the most common malignancy in men worldwide, with an estimated 174,650 new cases per year in the United States, and the second cancer-related cause of death, after lung cancer, with 31,620 deaths per year. While the 5 year survival rate for prostate cancer in patients without metastatic spread is nearly 100%, those with distant metastases have 5 year survival rates of approximately 30%. Initial diagnosis and assessment are based on PSA levels, Gleason score (derived from prostate biopsy), and advanced imaging modalities, including prostate MR imaging and PSMA-PET/computed tomography in patients with high-risk features.


Assuntos
Neoplasias da Próstata , Compostos Radiofarmacêuticos , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/patologia , Compostos Radiofarmacêuticos/uso terapêutico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Partículas beta/uso terapêutico
8.
Radiat Res ; 201(5): 479-486, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38407403

RESUMO

High-LET-type cell survival curves have been observed in cells that were allowed to incorporate 125I-UdR into their DNA. Incorporation of tritiated thymidine into the DNA of cells has also been shown to result in an increase in relative biological effectiveness in cell survival experiments, but the increase is smaller than observed after incorporation of 125I-UdR. These findings are explained in the literature by the overall complexity of the induced DNA damage resulting from energies of the ejected electron(s) during the decay of 3H and 125I. Chromosomal aberrations (CA) are defined as morphological or structural changes of one or more chromosomes, and can be induced by ionizing radiation. Whether the number of CA is associated with the linear energy transfer (LET) of the radiation and/or the actual complexity of the induced DNA double-strand breaks (DSB) remains elusive. In this study, we investigated whether DNA lesions induced at different cell cycle stages and by different radiation types [Auger-electrons (125I), ß- particles (3H), or γ radiation (137Cs)] have an impact on the number of CA induced after induction of the same number of DSB as determined by the γ-H2AX foci assay. Cells were synchronized and pulse-labeled in S phase with low activities of 125I-UdR or tritiated thymidine. For decay accumulation, cells were cryopreserved either after pulse-labeling in S phase or after progression to G2/M or G1 phase. Experiments with γ irradiation (137Cs) were performed with synchronized and cryopreserved cells in S, G2/M or G1 phase. After thawing, a CA assay was performed. All experiments were performed after a similar number of DSB were induced. CA induction after 125I-UdR was incorporated was 2.9-fold and 1.7-fold greater compared to exposure to γ radiation and radiation from incorporated tritiated thymidine, respectively, when measured in G2/M cells. In addition, measurement of CA in G2/M cells after incorporation of 125I-UdR was 2.5-fold greater when compared to cells in G1 phase. In contrast, no differences were observed between the three radiation qualities with respect to exposure after cryopreservation in S or G1 phase. The data indicate that the 3D organization of replicated DNA in G2/M cells seems to be more sensitive to induction of more complex DNA lesions compared to the DNA architecture in S or G1 cells. Whether this is due to the DNA organization itself or differences in DNA repair capability remains unclear.


Assuntos
Partículas beta , Radioisótopos de Césio , Aberrações Cromossômicas , Raios gama , Radioisótopos do Iodo , Trítio , Aberrações Cromossômicas/efeitos da radiação , Raios gama/efeitos adversos , Animais , Transferência Linear de Energia , Cricetulus , Elétrons , Humanos , Ciclo Celular/efeitos da radiação , Quebras de DNA de Cadeia Dupla/efeitos da radiação , Cricetinae , Células CHO
9.
Med Phys ; 51(5): 3725-3733, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38284426

RESUMO

BACKGROUND: Diffusing alpha-emitters radiation therapy (DaRT) is a novel brachytherapy technique that leverages the diffusive flow of 224Ra progeny within the tumor volume over the course of the treatment. Cell killing is achieved by the emitted alpha particles that have a short range in tissue and high linear energy transfer. The current proposed absorbed dose calculation method for DaRT is based on a diffusion-leakage (DL) model that neglects absorbed dose from beta particles. PURPOSE: This work aimed to couple the DL model with dose point kernels (DPKs) to account for dose from beta particles as well as to consider the non-local deposition of energy. METHODS: The DaRT seed was modeled using COMSOL multiphysics and the DL model was implemented to extract the spatial information of the diffusing daughters. Using Monte-Carlo (MC) methods, DPKs were generated for 212Pb, 212Bi, and their progenies since they were considered to be the dominant beta emitters in the 224Ra radioactive decay chain. A convolution operation was performed between the integrated number densities of the diffusing daughters and DPKs to calculate the total absorbed dose over a 30-day treatment period. Both high-diffusion and low-diffusion cases were considered. RESULTS: The calculated DPKs showed non-negligible energy deposition over several millimeters from the source location. An absorbed dose >10 Gy was deposited within a 1.8 mm radial distance for the low diffusion case and a 2.2 mm radial distance for the high diffusion case. When the DPK method was compared with the local energy deposition method that solely considered dose from alpha particles, differences above 1 Gy were found within 1.3 and 1.8 mm radial distances from the surface of the source for the low diffusion and high diffusion cases, respectively. CONCLUSIONS: The proposed method enhances the accuracy of the dose calculation method used for the DaRT technique.


Assuntos
Partículas alfa , Método de Monte Carlo , Radiometria , Dosagem Radioterapêutica , Partículas alfa/uso terapêutico , Difusão , Braquiterapia/métodos , Radioisótopos de Chumbo/uso terapêutico , Bismuto/uso terapêutico , Humanos , Partículas beta/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos
10.
Phys Med Biol ; 68(19)2023 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-37678259

RESUMO

Trans-arterial radioembolization (TARE) is an intra-arterial treatment method for liver malignancies. In this procedure, the therapeutic tumor dose is significant for predicting the treatment effectiveness while the dose absorbed in an organ at risk provides an understanding of its tolerance to radiation. This study proposes a Monte Carlo (MC) approach for determining absorbed organ doses for patients undergoing TARE treatment. The technique is based on the use of a voxel-based partial body model generated for each patient from his/her anatomical image data to represent the critical body structures more realistically. These structures are first segmented from image slices to create an image block which is then incorporated into a radiation transport package (MCNP6.2) to perform MC simulations. When used along with the parameters specific to a patient's treatment, such as lung-shunt factor, tumor-to-normal liver ratio, fractional uptakes, and administered activity, this approach allowed more accurate simulation of radiation interactions and hence provided absorbed doses specific to a TARE patient. The MC method also calculated the absorbed doses in organs or tissues that were close to target tissues for which the Medical Internal Radiation Dose Committee (MIRD) formalism makes no predictions. MIRD calculations were found to overestimate the absorbed doses by as much as 11% in lungs, 5% in liver, and 20% in tumor volumes. This raises concerns about the treatment's efficacy when estimating the correct activity to be administered to a patient. When each patient simulation was repeated with a90Y source spectrum to reflect the distribution of varying beta energies, the liver and the lungs were observed to receive relatively lower doses than those obtained with monoenergetic beta particles. Thus, it can be stated that the approach adopted in this study offers a more precise model of the patient's critical tissues and serves as a personalized dosimetric tool for TARE treatment planning.


Assuntos
Braquiterapia , Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Feminino , Masculino , Neoplasias Hepáticas/radioterapia , Partículas beta
11.
Molecules ; 28(16)2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37630410

RESUMO

Prostate-specific membrane antigen (PSMA)-based low-molecular-weight agents using beta(ß)-particle-emitting radiopharmaceuticals is a new treatment paradigm for patients with metastatic castration-resistant prostate cancer. Although results have been encouraging, there is a need to improve the tumor residence time of current PSMA-based radiotherapeutics. Albumin-binding moieties have been used strategically to enhance the tumor uptake and retention of existing PSMA-based investigational agents. Previously, we developed a series of PSMA-based, ß-particle-emitting, low-molecular-weight compounds. From this series, 177Lu-L1 was selected as the lead agent because of its reduced off-target radiotoxicity in preclinical studies. The ligand L1 contains a PSMA-targeting Lys-Glu urea moiety with an N-bromobenzyl substituent in the ε-amino group of Lys. Here, we structurally modified 177Lu-L1 to improve tumor targeting using two known albumin-binding moieties, 4-(p-iodophenyl) butyric acid moiety (IPBA) and ibuprofen (IBU), and evaluated the effects of linker length and composition. Six structurally related PSMA-targeting ligands (Alb-L1-Alb-L6) were synthesized based on the structure of 177Lu-L1. The ligands were assessed for in vitro binding affinity and were radiolabeled with 177Lu following standard protocols. All 177Lu-labeled analogs were studied in cell uptake and selected cell efficacy studies. In vivo pharmacokinetics were investigated by conducting tissue biodistribution studies for 177Lu-Alb-L2-177Lu-Alb-L6 (2 h, 24 h, 72 h, and 192 h) in male NSG mice bearing human PSMA+ PC3 PIP and PSMA- PC3 flu xenografts. Preliminary therapeutic ratios of the agents were estimated from the area under the curve (AUC0-192h) of the tumors, blood, and kidney uptake values. Compounds were obtained in >98% radiochemical yields and >99% purity. PSMA inhibition constants (Kis) of the ligands were in the ≤10 nM range. The long-linker-based agents, 177Lu-Alb-L4 and 177Lu-Alb-L5, displayed significantly higher tumor uptake and retention (p < 0.001) than the short-linker-bearing 177Lu-Alb-L2 and 177Lu-Alb-L3 and a long polyethylene glycol (PEG) linker-bearing agent, 177Lu-Alb-L6. The area under the curve (AUC0-192h) of the PSMA+ PC3 PIP tumor uptake of 177Lu-Alb-L4 and 177Lu-Alb-L5 were >4-fold higher than 177Lu-Alb-L2, 177Lu-Alb-L3, and 177Lu-Alb-L6, respectively. Also, the PSMA+ PIP tumor uptake (AUC0-192h) of 177Lu-Alb-L2 and 177Lu-Alb-L3 was ~1.5-fold higher than 177Lu-Alb-L6. However, the lowest blood AUC0-192h and kidney AUC0-192h were associated with 177Lu-Alb-L6 from the series. Consequently, 177Lu-Alb-L6 displayed the highest ratios of AUC(tumor)-to-AUC(blood) and AUC(tumor)-to-AUC(kidney) values from the series. Among the other agents, 177Lu-Alb-L4 demonstrated a nearly similar ratio of AUC(tumor)-to-AUC(blood) as 177Lu-Alb-L6. The tumor-to-blood ratio was the dose-limiting therapeutic ratio for all of the compounds. Conclusions: 177Lu-Alb-L4 and 177Lu-Alb-L6 showed high tumor uptake in PSMA+ tumors and tumor-to-blood ratios. The data suggest that linker length and composition can be modulated to generate an optimized therapeutic agent.


Assuntos
Albuminas , Partículas beta , Humanos , Masculino , Animais , Camundongos , Ligantes , Distribuição Tecidual , Ácido Butírico
12.
Med Phys ; 50(10): 6118-6129, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37469146

RESUMO

BACKGROUND: Positron probes can accurately localize malignant tumors by directly detecting positrons emitted from positron-emitting radiopharmaceuticals that accumulate in malignant tumors. In the conventional method for direct positron detection, multilayer scintillator detection and pulse shape discrimination techniques are used. However, some γ-rays cannot be distinguished by conventional methods. Accordingly, these γ-rays are misidentified as positrons, which may increase the error rate of positron detection. PURPOSE: To analyze the energy distribution in each scintillator of the multilayer scintillator detector to distinguish true positrons and γ-rays and to improve the positron detection algorithm by discriminating true and false positrons. METHODS: We used Autoencoder, an unsupervised deep learning architecture, to obtain the energy distribution data in each scintillator of the multilayer scintillator detector. The Autoencoder was trained to separate the combined signals generated from the multilayer scintillator detector into two signals of each scintillator. An energy window was then applied to the energy distribution obtained using the trained Autoencoder to distinguish true positrons from false positrons. Finally, the performance of the proposed method and conventional positron detection algorithm was evaluated in terms of the sensitivity and error rate for positron detection. RESULTS: The energy distribution map obtained using the trained Autoencoder was proven to be similar to that of the simulated results. Furthermore, the proposed method demonstrated a 29.79% (+0.42%p) increase in positron detection sensitivity compared to the conventional method, both having an equal error rate of 0.48%. However, when both methods were set to have the same sensitivity of 1.83%, the proposed method had an error rate that was 25.0% (-0.16%p) lower than that of the conventional method. CONCLUSIONS: We proposed and developed an Autoencoder-based positron detection algorithm that can discriminate between true and false positrons with a smaller error rate than conventional methods. We verified that the proposed method could increase the positron detection sensitivity while maintaining a low error rate compared to the conventional method. If the proposed algorithm is implemented in handheld positron detection probes or cameras, diseases such as cancers can be more accurately localized in a shorter time compared with using traditional methods.


Assuntos
Aprendizado Profundo , Neoplasias , Humanos , Tomografia por Emissão de Pósitrons/métodos , Partículas beta , Algoritmos
13.
J Radiol Prot ; 43(3)2023 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-37339608

RESUMO

A monitoring programme, in place since 2006, continues to recover radioactive particles (<2 mm diameter) and larger objects from the beaches of West Cumbria. The potential risks to members of the public using the beaches are mainly related to prolonged skin contact with or the inadvertent ingestion of small particles. Most particles are classified as either 'beta-rich' or 'alpha-rich' and are detected as a result of their caesium-137 or americium-241 content. Beta-rich particles generally also contain strontium-90, with90Sr:137Cs ratios of up to about 1:1, but typically <0.1:1. Alpha-rich particles contain plutonium isotopes, with Pu:241Amαratios usually around 0.5-0.6:1. 'Beta-rich' particles have the greatest potential to cause localised skin damage if held in stationary contact with the skin for prolonged periods. However, it is concluded that only particles of >106Bq of137Cs, with high90Sr:137Cs ratios, would pose a significant risk of causing acute skin ulceration. No particles of this level of activity have been found. Inadvertent ingestion of a particle will result in the absorption to blood of a small proportion of the radionuclide content of the particle. The subsequent retention of radionuclides in body organs and tissues presents a potential risk of the development of cancer. For 'beta-rich' particles with typical activities (mean 2 × 104Bq137Cs, Sr:Cs ratio of 0.1:1), the estimated committed effective doses are about 30µSv for adults and about 40µSv for 1 year old infants, with lower values for 'alpha-rich' particles of typical activities. The corresponding estimates of lifetime cancer incidence following ingestion for both particle types are of the order of 10-6for adults and up to 10-5for infants. These estimates are subject to substantial uncertainties but provide an indication of the low risks to members of the public.


Assuntos
Praias , Exposição Ambiental , Resíduos Radioativos , Poluentes Radioativos do Solo , Humanos , Lactente , Radioisótopos de Césio/efeitos adversos , Radioisótopos de Césio/análise , Plutônio/efeitos adversos , Plutônio/análise , Poluentes Radioativos do Solo/efeitos adversos , Poluentes Radioativos do Solo/análise , Reino Unido , Resíduos Radioativos/efeitos adversos , Resíduos Radioativos/análise , Adulto , Medição de Risco , Exposição Ambiental/efeitos adversos , Monitoramento Ambiental , Pele/efeitos da radiação , Ingestão de Alimentos , Neoplasias/induzido quimicamente , Partículas beta/efeitos adversos , Partículas alfa/efeitos adversos
14.
Radiat Prot Dosimetry ; 199(11): 1248-1255, 2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37295928

RESUMO

The mass attenuation coefficient of lead nitrate (Pb(NO3)2)-filled polycarbonate (PC) composite films were determined both computationally (using Baltakmen's and Thummel empirical formulae) and experimentally using 204Tl and 90Sr-90Y radio-isotopes for films at different filler levels 0, 5, 15, 25, 35 and 50 weight percent (Wt.%). In comparison with Thummel empirical formula, the values obtained from Baltakmen's empirical formula is in good agreement with the experiment. The percentage decrease of half value layer values were (52 ± 8) and (60 ± 10)% for 204Tl and 90Sr-90Y, on comparing the values for 0 and 50 Wt.% films, and so the prepared composite films shield the beta particles effectively. The PC that used to shield the low-energy beta particles of 90Sr-90Y can also moderate the higher energy beta particles; the plot of end point energy of 90Sr-90Y versus thickness of PC exhibits a decreasing trend, which confirms that PC acts as an electron moderator.


Assuntos
Radioisótopos de Estrôncio , Radioisótopos de Ítrio , Chumbo , Partículas beta
15.
Phys Med ; 108: 102545, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37021607

RESUMO

Radio-Guided Surgery (RGS) is a nuclear medicine technique to support the surgeon during surgery towards a complete tumor resection. It is based on intraoperative detection of radiation emitted by a radio-pharmaceutical that bounds selectively to tumoral cells. In the past years, an approach that exploits ß- emitting radiotracers has been pursued to overtake some limitations of the traditional RGS based on γ emission. A particle detector dedicated to this application, demonstrating very high efficiency to ß- particles and remarkable transparency to photons, has been thus developed. As a by-product, its characteristics suggested the possibility to utilize it with ß+ emitting sources, more commonly in use in nuclear medicine. In this paper, performances of such detector on 18F liquid sources are estimated by means of Monte Carlo simulations (MC) and laboratory measurements. The experimental setup with a 18F saline solution comprised a "positron signal" spot (a 7 × 10 mm cylinder representing the tumor residual), and a surrounding "far background" volume, that represented for the detector an almost isotropic source of annihilation photons. Experimental results show good agreement with MC predictions, thus confirming the expected performances of the detector with 18F, and the validity of the developed MC simulation as a tool to predict the gamma background determined by a diffuse source of annihilation photons.


Assuntos
Neoplasias , Cirurgia Assistida por Computador , Humanos , Partículas beta , Simulação por Computador , Método de Monte Carlo , Fótons , Tomografia por Emissão de Pósitrons/métodos
16.
J Environ Radioact ; 259-260: 107109, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36652762

RESUMO

Analysis of cytogenetics effects of ionizing radiation for flora and fauna is essential to determine the impact on these communities and may produce an efficient warning system to avoid harm to human health. Onion (Allium cepa) is a well-established in vivo standard model, and it is widely used in cytogenetics studies for different environmental pollutants. In this work, onion roots were exposed to 0.04-1.44 Gy of ß-particles from a 90Sr/90Y source. We investigated the capacity of brief external exposures to ß-particles on inducing cytogenetic damages in root meristematic cells of onion aiming to verify if onion can be used as a radiation-sensitive cytogenetic bioindicator. A nonlinear increase in the frequencies of chromosomal aberrations and cells with micronuclei was observed. Onion roots exposed to doses 0.13 Gy or higher of ß-particles showed a significant difference (p<0.05) in these frequencies when compared to the unirradiated group. The frequencies of these endpoints showed to be suitable to assess the difference in the dose of beta radiation received from 0.36 Gy. Our research shows the potential of using cytogenetic effects in Allium cepa cells as a biological indicator for a first screening of genotoxic damages induced by brief external exposures to ß-particles.


Assuntos
Allium , Monitoramento de Radiação , Humanos , Cebolas/genética , Cebolas/efeitos da radiação , Biomarcadores Ambientais , Partículas beta , Raízes de Plantas , Aberrações Cromossômicas , Análise Citogenética , Dano ao DNA
17.
Appl Radiat Isot ; 192: 110574, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36525912

RESUMO

Combination of two or three dissimilar scintillator materials as a radiation detector has found major role in environmental radiation monitoring. In this paper, a three-layer Phoswich detector including BC-400, YAG, and CsI was designed to efficiently discriminate gamma-ray in the beta events up to 3.2 MeV using a simple rise-time discrimination method. MCNPX Monte Carlo code was used to obtain interaction probability of beta and gamma-rays as well as optimum thicknesses of the layers in the designing process. The optical transport of the system was simulated by GEANT4. In this regard, the pulses from simultaneous beta-gamma emitter sources were detected and discriminated based on pulse's rise-time so that the minimum number of gamma-ray contaminating events was observed in the beta spectrum. The results showed that using the proposed configuration and the method, output pulses with a rise-time shorter than 9 ns have been successfully detected as a beta particle while those with rising time longer than 15 ns have been identified as gamma-ray events. Overall results revealed that using the proposed system, an individual spectrum of beta particles or gamma-rays can be recorded from a simultaneous beta-gamma emitter source that minimizes contribution of the other radiation.


Assuntos
Partículas beta , Monitoramento de Radiação , Simulação por Computador , Método de Monte Carlo
18.
Enzymes ; 51: 131-152, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36336406

RESUMO

Tritium is a radioisotope of hydrogen emitting low energy ß-rays in disintegration to 3He. DNA molecules are damaged mainly by ß-ray irradiation, and additional damages can be induced by break of chemical bond by nuclear transmutation to inert 3He. Deep knowledges of the mechanisms underlying DNA damages lead to better understanding of biological effects of tritium. This chapter reviews recent experimental and computer simulation activities on quantitative evaluation of damage rates by ß-ray irradiation and nuclear transmutation. The rate of DNA double-strand breaks in tritiated water has been examined using a single molecule observation method. The effects of ß-ray irradiation were not noticeable at the level of tritium concentration of ∼kBq/cm3, while the irradiation effects were clear at tritium concentrations of ∼MBq/cm3. The factors affecting on the DSB rate are discussed. A new image processing method for the automatic measurement of DNA length using OpenCV and deep learning is also introduced. The effects of tritium transmutation on hydrogen bonds acting between the two main strands of DNA have been examined using molecular dynamics simulations. The study showed that the collapsing of DNA structure by the transmutation can be quantitatively evaluated using the root mean square deviation of atomic positions.


Assuntos
DNA , Água , Masculino , Humanos , Trítio , Simulação por Computador , DNA/genética , Partículas beta
19.
Appl Radiat Isot ; 190: 110471, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36183661

RESUMO

The suitable choice of an activator and host combination is essential for synthesizing very sensitive thermoluminescence phosphors. In addition, conspicuous synthesis variables must be optimized to achieve the maximal response. The research presented herein shows that the most recommendable conditions to improve the thermoluminescence response of beta irradiated Gd1-xEuxAlO3 phosphors were: x = 0.02 for europium stoichiometry and 1500 °C for the calcination temperature. The glow curve recorded for the most sensitive phosphor was partially erased by photo-bleaching, and thus, should yield optically stimulated luminescence.


Assuntos
Partículas beta , Európio , Luminescência , Temperatura
20.
Radiat Prot Dosimetry ; 198(13-15): 1009-1013, 2022 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-36083726

RESUMO

To evaluate biological effects triggered by low levels of radiation, we established a uniquely sensitive experimental system to detect somatic mutations. By using the system, we found that mutant frequencies induced by X-rays were statistically significant at doses over 0.15 Gy, and a linear dose relationship with the mutant frequency was observed at doses over 0.15 Gy. The mutation spectra analysis revealed that mutation events generated by X-ray doses below 0.1 Gy were similar to those observed in unirradiated controls. In addition, a significant inflection point for both, the mutant frequency and the mutation spectra, was found at dose-rates around 11 mGy/day when cells were cultured in medium containing tritiated water. Because induced radiation-type events presented a clear dose/dose-rate dependency above the critical dose or the inflection point, these observations suggest that mutation events generated by radiation could change at a threshold dose-rate or a critical dose.


Assuntos
Partículas beta , Quebras de DNA de Cadeia Dupla , Relação Dose-Resposta à Radiação , Mutação , Trítio , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA