Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.298
Filtrar
1.
Spectrochim Acta A Mol Biomol Spectrosc ; 319: 124559, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-38830331

RESUMO

In this work, we present a novel colorimetric sensing platform for the sensitive detection of ethamsylate (ETM) usingultrathin MnO2 nanosheets with enhancedoxidase-mimicking activity. A facile template-free hydrothermal process was applied to synthesize the MnO2 nanosheets under mild conditions. The nanosheets exhibited oxidase-mimicking activity, facilitating the conversion of TMB into the blue-colored oxTMB in the absence of H2O2. However, the presence of ETM inhibited this activity, resulting in the conversion of oxTMB back to colorless TMB and a substantial decrease in the blue color intensity. The colorimetric response exhibited a linear relationship with ETM concentration over the range of 0.5 to 10.0 µg/mL and a detection limit of 0.156 µg/mL. To further elucidate the underlying mechanism, we performed extensive characterization and kinetic experiments. The findings demonstrated that this unique property is attributed to the remarkable capacity of the MnO2 nanosheets to absorb oxygen, producing superoxide radicals (O2-). The oxidase-mimicking activity of the nanosheets was further confirmed by the reaction kinetics, following Michaelis-Menten's behavior. Moreover, the applicability of the sensing platform was assessed by determining ETM concentrations in various real samples (different pharmaceuticals, human plasma, and environmental water). The well-established platform demonstrates the prospective role that nanomaterials-based sensing platforms may play in clinical diagnostics, pharmaceutical analysis, and other relevant fields.


Assuntos
Colorimetria , Limite de Detecção , Compostos de Manganês , Nanoestruturas , Óxidos , Oxirredutases , Colorimetria/métodos , Compostos de Manganês/química , Óxidos/química , Nanoestruturas/química , Oxirredutases/metabolismo , Oxirredutases/química , Cinética , Peróxido de Hidrogênio/análise , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/metabolismo , Materiais Biomiméticos/química , Benzidinas/química
2.
Spectrochim Acta A Mol Biomol Spectrosc ; 319: 124561, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-38833884

RESUMO

To satisfy the public's urgent demand for food safety and protect the ecological environment, sensitive detection of glyphosate holds paramount importance. Here, we discovered that glyphosate can engage in specific interactions with iron organic frameworks (Fe-MOFs) nanozymes, enabling a selective detection of glyphosate. Based on this principle, an innovative colorimetric and fluorescent dual-mode detection approach was devised. Specifically, Fe-MOFs were synthesized at room temperature, exhibiting remarkable peroxidase-mimic activity. These nanozymes catalyze the conversion of colorless and fluorescent 3,3',5,5'-Tetramethylbenzidine (TMB) into blue oxidized and nonfluorescent TMB (oxTMB) in the presence of H2O2. However, the introduction of glyphosate disrupts this process by interacting with Fe-MOFs, significantly inhibiting the catalytic activity of Fe-MOFs through both physical (electrostatic and hydrogen bonding) and chemical interactions. This suppression further hindered the conversion of TMB to oxTMB, resulting in a reduction in absorbance and a corresponding enhancement in fluorescence. The method offers a colorimetric and fluorescence dual-mode detection capability with enhanced applicability. Notably, our approach avoids complex material modifications and is more stable and cost-effective than the traditional enzyme inhibition methods. This innovative detection technique holds immense potential for practical applications and provides a fresh perspective for the detection of pesticide residues.


Assuntos
Colorimetria , Glicina , Glifosato , Ferro , Estruturas Metalorgânicas , Espectrometria de Fluorescência , Glicina/análogos & derivados , Glicina/análise , Glicina/química , Ferro/química , Ferro/análise , Estruturas Metalorgânicas/química , Colorimetria/métodos , Espectrometria de Fluorescência/métodos , Benzidinas/química , Peróxido de Hidrogênio/análise , Peróxido de Hidrogênio/química , Catálise , Herbicidas/análise , Nanoestruturas/química
3.
Sensors (Basel) ; 24(11)2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38894238

RESUMO

In this paper, a novel fluorescent detection method for glucose and lactic acid was developed based on fluorescent iron nanoclusters (Fe NCs). The Fe NCs prepared using hemin as the main raw material exhibited excellent water solubility, bright red fluorescence, and super sensitive response to hydrogen peroxide (H2O2). This paper demonstrates that Fe NCs exhibit excellent peroxide-like activity, catalyzing H2O2 to produce hydroxyl radicals (•OH) that can quench the red fluorescence of Fe NCs. In this paper, a new type of glucose sensor was established by combining Fe NCs with glucose oxidase (GluOx). With the increase in glucose content, the fluorescence of Fe NCs decreases correspondingly, and the glucose content can be detected in the scope of 0-200 µmol·L-1 (µM). Similarly, the lactic acid sensor can also be established by combining Fe NCs with lactate oxidase (LacOx). With the increase in lactic acid concentration, the fluorescence of Fe NCs decreases correspondingly, and the lactic acid content can be detected in the range of 0-100 µM. Furthermore, Fe NCs were used in the preparation of gel test strip, which can be used to detect H2O2, glucose and lactic acid successfully by the changes of fluorescent intensity.


Assuntos
Glucose Oxidase , Glucose , Peróxido de Hidrogênio , Ferro , Ácido Láctico , Ácido Láctico/análise , Ácido Láctico/química , Glucose/análise , Glucose/química , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Ferro/química , Glucose Oxidase/química , Glucose Oxidase/metabolismo , Técnicas Biossensoriais/métodos , Fluorescência , Espectrometria de Fluorescência/métodos , Corantes Fluorescentes/química , Oxigenases de Função Mista/química , Oxigenases de Função Mista/metabolismo , Nanopartículas Metálicas/química
4.
Sensors (Basel) ; 24(11)2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38894416

RESUMO

L-tryptophan is an amino acid that is essential to the metabolism of humans. Therefore, there is a high interest for its detection in biological fluids including blood, urine, and saliva for medical studies, but also in food products. Towards this goal, we report on a new electrochemiluminescence (ECL) method for L-tryptophan detection involving the in situ production of hydrogen peroxide at the surface of boron-doped diamond (BDD) electrodes. We demonstrate that the ECL response efficiency is directly related to H2O2 production at the electrode surface and propose a mechanism for the ECL emission of L-tryptophan. After optimizing the analytical conditions, we show that the ECL response to L-tryptophan is directly linear with concentration in the range of 0.005 to 1 µM. We achieved a limit of detection of 0.4 nM and limit of quantification of 1.4 nM in phosphate buffer saline (PBS, pH 7.4). Good selectivity against other indolic compounds (serotonin, 3-methylindole, tryptamine, indole) potentially found in biological fluids was observed, thus making this approach highly promising for quantifying L-tryptophan in a broad range of aqueous matrices of interest.


Assuntos
Boro , Diamante , Técnicas Eletroquímicas , Eletrodos , Medições Luminescentes , Triptofano , Triptofano/química , Triptofano/análise , Boro/química , Diamante/química , Técnicas Eletroquímicas/métodos , Medições Luminescentes/métodos , Humanos , Limite de Detecção , Técnicas Biossensoriais/métodos , Peróxido de Hidrogênio/análise , Peróxido de Hidrogênio/química
5.
Mikrochim Acta ; 191(6): 352, 2024 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-38806756

RESUMO

Developing convenient and reliable methods for Hg2+ monitoring is highly important. Some precious metal nanomaterials with intriguing peroxidase-like activity have been used for highly sensitive Hg2+ detection. However, H2O2 must be added during these detections, which impedes practical applications of Hg2+ sensors due to its susceptible decomposition by environmental factors. Herein, we discovered that the combination of Hg2+ and palladium metal-organic framework@graphene (Pd-MOF@GNs) exhibits oxidase-like activity (OXD). In the absence of H2O2, this activity not only catalyzes the oxidation of chromogenic substrates such as 3,3',5,5'-tetramethylbenzidine (TMB) or o-phenylenediamine (OPD) to produce a color change but also enhances the electrical signals during OPD oxidation. Based on these properties, an effective and convenient dual-mode colorimetric and electrochemical sensor for Hg2+ has been developed. The colorimetric and amperometric linear relationships for Hg2+ were 0.045 µM-0.25 mM and 0.020 µM-2.0 mM, respectively. The proposed strategy shows good recovery in real sample tests, indicating promising prospects for multiple environmental sample detection of Hg2+ without relying on H2O2. The colorimetric and electrochemical dual-mode Hg2+ sensor is expected to hold great potentials in applications such as environmental monitoring, rapid field detection, and integration into smartphone detection of Hg2+.


Assuntos
Colorimetria , Técnicas Eletroquímicas , Grafite , Limite de Detecção , Mercúrio , Estruturas Metalorgânicas , Paládio , Grafite/química , Colorimetria/métodos , Mercúrio/análise , Mercúrio/química , Estruturas Metalorgânicas/química , Paládio/química , Técnicas Eletroquímicas/métodos , Benzidinas/química , Oxirredução , Poluentes Químicos da Água/análise , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Oxirredutases/química , Oxirredutases/metabolismo , Fenilenodiaminas/química
6.
Chem Commun (Camb) ; 60(47): 6059-6062, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38780054

RESUMO

We developed a system to detect multiple target biomolecules through sensing motif-tethered oligodeoxynucleotides. DNA-based molecular probes gave the primary amine motif upon reaction with the target biomolecules, glutathione (GSH) and H2O2. After labelling with biotin, the product DNAs were selectively collected to be quantified by qPCR.


Assuntos
Biotina , Glutationa , Peróxido de Hidrogênio , Oligodesoxirribonucleotídeos , Oligodesoxirribonucleotídeos/química , Oligodesoxirribonucleotídeos/genética , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Glutationa/química , Glutationa/análise , Biotina/química , DNA/química , Técnicas Biossensoriais/métodos
7.
Analyst ; 149(13): 3651-3660, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38814120

RESUMO

Monitoring methods for beta-lactam (ß-lactam) antibiotics, especially for ampicillin (AMP), with simple operation and sensitivity for realtime applications are highly required. To address this need, antioxidant carbon dots (E-CDs) with excellent fluorescence properties were synthesized using citric acid and ethylenediamine as raw materials. With a quantum yield of 81.97%, E-CDs exhibited a specific and sensitive response to ˙OH. The quenched fluorescence of E-CDs by the formed ˙OH could be restored through a competition reaction with AMP. Leveraging the signal-quenching strategy of E-CDs, H2O2, and Fe2+, a fluorescence signal-on strategy was developed using AMP as the fluorescence recovery agent for the sensitive detection of AMP. The mechanism of the quenching of E-CDs by ˙OH was attributed to the damaging effect of ˙OH on E-CDs. Under optimal conditions, the detection limit of this method for AMP was determined to be 0.38 µg mL-1. This method was successful in drug quality control and the spiked detection of AMP in lake water, milk, and sea cucumber, presenting a viable option for convenient and rapid antibiotic monitoring methods.


Assuntos
Ampicilina , Carbono , Limite de Detecção , Pontos Quânticos , Espectrometria de Fluorescência , Carbono/química , Ampicilina/análise , Ampicilina/química , Pontos Quânticos/química , Espectrometria de Fluorescência/métodos , Animais , Antioxidantes/análise , Antioxidantes/química , Leite/química , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Radical Hidroxila/química , Radical Hidroxila/análise , Antibacterianos/análise , Antibacterianos/química , Corantes Fluorescentes/química , Ácido Cítrico/química , Fluorescência , Etilenodiaminas
8.
Biosens Bioelectron ; 260: 116448, 2024 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-38820720

RESUMO

Functionalized few-layer borophene (FFB) was prepared using gallnut extract and coffee waste extract as natural exfoliating and stabilizing agents in an environmentally friendly ultrasonic and high shear exfoliation. Here, a facile precipitation method was employed to grow iron oxide nanoparticles doped with cerium (Ce-FeONPs) onto the surface of FFB. This intriguing combination of materials yielded Ce-FeONPs nanoparticles that exhibited exceptional peroxidase-like activity, efficiently catalyzing the conversion of 3,3',5,5'-tetramethylbenzidine (TMB) to a blue oxidized TMB (oxTMB) in the presence of hydrogen peroxide (H2O2). Additionally, the introduction of FFB contributes a reducibility effect to the catalytic oxidation of TMB, facilitating the restoration of the oxTMB to TMB. Thus, FFB-Ce-FeONPs showcase intriguing properties encompassing both oxidative and reductive characteristics, suggesting their potential as a reagent for repeated detection of H2O2. Moreover, a colorimetric sensing system enabled the liner detection of H2O2 spanning a concentration range from 0.08 to 1 mM, with a detection limit of 0.03 mM. Noteworthily, FFB-Ce-FeONPs demonstrated sustained efficacy over ten successive recycling cycles, as indicated by consistent slopes and observable color changes. In summary, this work reports the first application of nanoenzymes in repetitive H2O2 detection. Even after ten multiple cycles, the detection limit remains virtually unaltered, underscoring the robustness and enduring effectiveness of the engineered nanomaterial. The proposed simultaneous oxidation and reduction strategies for detecting H2O2 showed a commendable capability in ten cycles of H2O2 detection, thus providing a promising approach in the field of H2O2 detection.


Assuntos
Técnicas Biossensoriais , Cério , Colorimetria , Peróxido de Hidrogênio , Limite de Detecção , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Cério/química , Técnicas Biossensoriais/métodos , Colorimetria/métodos , Oxirredução , Compostos de Boro/química , Química Verde , Benzidinas/química , Catálise , Nanopartículas Magnéticas de Óxido de Ferro/química , Compostos Férricos/química
9.
Biosens Bioelectron ; 260: 116433, 2024 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-38820721

RESUMO

The limitations of solvent residues, unmanageable film growth regions, and substandard performance impede the extensive utilization of metal-organic framework (MOF) films for biosensing devices. Here, we report a strategy for ion design in gas-phase synthesized flexible MOF porous film to attain universal regulation of biosensing performances. The key fabrication process involves atomic layer deposition of induced layer coupled with lithography-assisted patterning and area-selective gas-phase synthesis of MOF film within a chemical vapor deposition system. Sensing platforms are subsequently formed to achieve specific detection of H2O2, dopamine, and glucose molecules by respectively implanting Co, Fe, and Ni ions into the network structure of MOF films. Furthermore, we showcase a practical device constructed from Co ions-implanted ZIF-4 film to accomplish real-time surveillance of H2O2 concentration at mouse wound. This study specifically elucidates the electronic structure and coordination mode of ion design in MOF film, and the obtained knowledge aids in tuning the electrochemical property of MOF film for advantageous sensing devices.


Assuntos
Técnicas Biossensoriais , Dopamina , Técnicas Eletroquímicas , Peróxido de Hidrogênio , Estruturas Metalorgânicas , Técnicas Biossensoriais/métodos , Estruturas Metalorgânicas/química , Peróxido de Hidrogênio/análise , Peróxido de Hidrogênio/química , Técnicas Eletroquímicas/métodos , Animais , Camundongos , Dopamina/análise , Dopamina/química , Glucose/análise , Glucose/isolamento & purificação , Glucose/química , Cobalto/química , Níquel/química , Íons/química
10.
Talanta ; 276: 126244, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38754185

RESUMO

The detections of H2O2 and catalase play an important role in daily life. This study introduces a paper-based flow sensor that is specifically designed to detect H2O2 and catalase. The sensor utilizes a hydrogel composed of cross-linked 4-carboxyphenylboronic acid and polyvinyl alcohol. When H2O2 is in contact with the hydrogel, the B-C bonds of the hydrogel undergo a reactive process, causing decomposition of the hydrogel. The pH indicator strip enables the visual monitoring of the viscosity change that occurs during the gel-sol transition. The quantification of H2O2 is accomplished by assessing the proportion of water coverage on the pH indicator strip. The sensor shows a detection limit of 0.077 wt% and is applicable for the quantitative measurement of H2O2 in routinely used disinfectants. Furthermore, the presence of catalase is effectively identified and the detection of catalase in milk is successfully fulfilled. In summary, this work proposes a simple, user-friendly, label-free, and cost-effective method for constructing a paper-based flow sensor using borate cross-linked polyvinyl alcohol hydrogel, showing great potential for detecting H2O2 and catalase in various practical scenarios.


Assuntos
Boratos , Catalase , Peróxido de Hidrogênio , Papel , Álcool de Polivinil , Peróxido de Hidrogênio/análise , Peróxido de Hidrogênio/química , Álcool de Polivinil/química , Catalase/química , Boratos/química , Hidrogéis/química , Animais , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Leite/química , Limite de Detecção , Reagentes de Ligações Cruzadas/química , Concentração de Íons de Hidrogênio
11.
Talanta ; 276: 126262, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38761660

RESUMO

Implementing the concept of turning waste into treasure, the conversion of biomass waste into high-value carbon materials, especially carbon dots (CDs), has pointed out a new direction for disease diagnosis, tumor treatment, and other aspects. In this work, we have reported the GL-CDs(Fe) via a simple synthesis route exploiting Ganoderma lucidum waste as the precursor. Thanks to their excellent optical property and peroxidase mimetic activity, a novel GL-CDs(Fe)-based ratio fluorescence/colorimetric/smartphone triple mode sensing platform is cleverly fabricated for glucose determination with the LOD of 0.28, 0.37, and 0.52 µΜ separately. Especially, this triple mode biosensor is successfully utilized for glucose detection in serum samples with the relative error of less than ±8 % compared with clinical reports. Surprisingly, the GL-CDs(Fe) also presents immense application prospects in high-level anti-counterfeiting aspects due to their excellent luminescent properties, high water-solubility, and easy availability. Furthermore, GL-CDs(Fe) can catalyze excessive H2O2 inside tumor cells to produce massive hydroxyl radicals (·OH) which break down the redox levels of cancer cells and thereby eliminate tumor cells. Thus, this integrated "Three-in-One" multifunctional platform based on GL-CDs(Fe) unveils enormous research and application prospects for bio-sensing, anti-counterfeiting, cancer treatment.


Assuntos
Técnicas Biossensoriais , Carbono , Ferro , Pontos Quânticos , Reishi , Carbono/química , Reishi/química , Humanos , Pontos Quânticos/química , Ferro/química , Técnicas Biossensoriais/métodos , Antineoplásicos/química , Antineoplásicos/farmacologia , Glucose/análise , Glucose/química , Glicemia/análise , Linhagem Celular Tumoral , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Colorimetria/métodos , Proliferação de Células/efeitos dos fármacos
12.
Talanta ; 276: 126259, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38761664

RESUMO

Hypoxanthine is a promising index for evaluating the freshness of various aquatic products. Combined the hydrogels containing upconversion nanoparticles (UCNPs), Co3O4 NPs, and N-ethyl-N-(3-sulfopropyl)-3-methylaniline sodium salt/4-amino-antipyrine (TOPS/4-AAP) with a smartphone, a portable sensor was developed for the convenient, sensitive detection of hypoxanthine. With the H2O2 from xanthine oxidase (XOD)-catalyzed reactions of hypoxanthine, the fluorescence of UCNPs was effectively quenched by the purple product produced from the oxidization of TOPS/4-AAP catalyzed by Co3O4 NPs exhibiting peroxidase activity, among which the color change could be transformed into digital signals for quantification of hypoxanthine. The Green value in the RGB analysis of the fluorescence image was negatively proportional to hypoxanthine concentration in the range of 2.5-20 mg/L with a detection limit of 0.69 mg/L and a quantitation limit of 2.30 mg/L. Finally, this sensor was applied for hypoxanthine detection in real aquatic products, showing potential application for freshness evaluation of aquatic products.


Assuntos
Cobalto , Hidrogéis , Hipoxantina , Óxidos , Smartphone , Hipoxantina/análise , Hidrogéis/química , Óxidos/química , Cobalto/química , Fluorescência , Limite de Detecção , Nanopartículas/química , Animais , Espectrometria de Fluorescência/métodos , Peróxido de Hidrogênio/análise , Peróxido de Hidrogênio/química
13.
Talanta ; 276: 126290, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38805755

RESUMO

A very sensitive electrochemical biosensor, with haemoglobin (Hb) as its basis, has been created to quantify hydrogen peroxide (H2O2), an essential marker in environmental monitoring, food safety, and medical diagnosis. The sensor uses a simple, eco-friendly preparation method. Hb was immobilised on manganese dioxide nanostructure/gold nanoparticles/poly-diallydimethylammonium chloride-functionalised multiwalled carbon nanotubes (PDDA-MWCNT/AuNP/MnO2), characterised using various techniques: amperometry, voltammetry, X-ray diffraction (XRD), and transmission electron microscopy (TEM). Nafion was used as a binder membrane to preserve the biological and electrochemical properties of the protein on the modified electrode. In comparison to earlier research, the novel biosensor had a lower detection limit (1.83 µM) and a limit of quantification (6.11 µM) (S/N = 3) for H2O2. It also exhibited notable reproducibility, long-term stability, and repeatability. It was effectively used to measure the amount of H2O2 in cow milk and orange juice, yielding recoveries in the order of 98.90-99.53 % with RSDs less than 5.0 %, which makes it a promising biosensor for food control.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Ouro , Hemoglobinas , Peróxido de Hidrogênio , Compostos de Manganês , Nanopartículas Metálicas , Leite , Nanotubos de Carbono , Óxidos , Compostos de Amônio Quaternário , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Ouro/química , Hemoglobinas/análise , Hemoglobinas/química , Técnicas Biossensoriais/métodos , Compostos de Manganês/química , Nanopartículas Metálicas/química , Compostos de Amônio Quaternário/química , Nanotubos de Carbono/química , Óxidos/química , Técnicas Eletroquímicas/métodos , Leite/química , Animais , Polietilenos/química , Bovinos , Sucos de Frutas e Vegetais/análise , Limite de Detecção , Eletrodos
14.
Talanta ; 276: 126207, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38718650

RESUMO

Metal-Organic Framework (MOF) based nanozymes with clear structure are beneficial for exploration of structural-performance and exhibit broad prospects in improving activity. In this study, the prepared bimetallic Fe3Ni-MOF nanozyme was superior to single metal MOF in the peroxidase-like activity. Subsequently, a derivative nanozyme (Fe3Ni-MOF-Ar) was prepared by pyrolysis using Fe3Ni-MOF as the precursor in argon atomoshere with controlled temperature. The investigated of Fe3Ni-MOF-Ar revealed that the irregular macroporous state and the presence of heterovalent FeIII/FeII sites of Fe3Ni-MOF-Ar enable the retention, exposure, and electronic structure regulation of active sites, promoting the dual mechanism (the generation of •OH and electron transfer mechanism) and significantly increasing the peroxidase-like activity. Fe3Ni-MOF-Ar exhibited a strong affinity for substrate H2O2, which is higher than horseradish peroxidase. Ascorbic acid and cysteine are typical substances of antioxidants. Fe3Ni-MOF-Ar was used for sensitive colorimetric detection of ascorbic acid and cysteine, and the detection limit was as low as 150 and 60 nM. In addition, the smartphone devices was used to detection of antioxidant equivalent ascorbic acid, with a detection range of 0.5-120 µM. Fe3Ni-MOF-Ar nanozyme is feasible for sensitive detection of saliva total antioxidant capacity.


Assuntos
Antioxidantes , Ácido Ascórbico , Estruturas Metalorgânicas , Saliva , Smartphone , Saliva/química , Estruturas Metalorgânicas/química , Humanos , Antioxidantes/análise , Antioxidantes/química , Ácido Ascórbico/análise , Ácido Ascórbico/química , Domínio Catalítico , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Peroxidase/química , Peroxidase/metabolismo , Cisteína/análise , Cisteína/química , Colorimetria/métodos , Níquel/química , Limite de Detecção
15.
Talanta ; 276: 126219, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38733936

RESUMO

This study presents a potent paper-based analytical device (PAD) for quantifying various sugars using an innovative bi-nanozyme made from a 2-dimensional Fe/Ce metal-organic framework (FeCe-BTC). The MOF showed excellent bifunctional peroxidase-oxidase activities, efficiently catalyzing luminol's chemiluminescence (CL) reaction. As a peroxidase-like nanozyme, FeCe-BTC could facilitate the dissociation of hydrogen peroxide (H2O2) into hydroxyl radicals, which then oxidize luminol. Additionally, it was also discovered that when reacting with H2O2, the MOF turns into a mixed-valence MOF, and acts as an oxidase nanozyme. This activity is caused by the generated Ce4+ ions in the structure of MOF that can directly oxidize luminol. The MOF was directly synthesized on the PAD and cascaded with specific natural enzymes to establish simple, rapid, and selective CL sensors for the measurement of different sugars. A cell phone was also used to record light intensities, which were then correlated to the analyte concentration. The designed PAD showed a wide linear range of 0.1-10 mM for glucose, fructose, and sucrose, with detection limits of 0.03, 0.04, and 0.04 mM, respectively. It showed satisfactory results in food and biological samples with recovery values ranging from 95.8 to 102.4 %, which makes it a promising candidate for point-of-care (POC) testing for food control and medicinal purposes.


Assuntos
Medições Luminescentes , Luminol , Estruturas Metalorgânicas , Papel , Smartphone , Luminol/química , Estruturas Metalorgânicas/química , Medições Luminescentes/métodos , Ferro/química , Ferro/análise , Cério/química , Peroxidase/química , Peroxidase/metabolismo , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Oxirredutases/química , Oxirredutases/metabolismo , Açúcares/análise , Açúcares/química , Materiais Biomiméticos/química , Luminescência
16.
J Mater Chem B ; 12(22): 5418-5430, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38716837

RESUMO

Constructing metal-organic gels (MOGs) with enzyme-catalyzed activity and studying their catalytic mechanism are crucial for the development of novel nanozyme materials. In this study, a Co@Fe MOG with excellent peroxidase activity was developed by a simple and mild one-pot process. The results showed that the material exhibited almost a single peroxidase activity under optimal pH conditions, which allowed it to attract and oxidize the chromogenic substrate 3,3',5,5'-tetramethylbenzidine (TMB). Based on the active electron transfer between the metal centers and the organic ligand in the synthetic material, the Co@Fe MOG-H2O2-TMB system was verified to be able to detect H2O2 and citric acid (CA). The catalytic microenvironment formed by the adsorption and the catalytic center accelerated the electron-transfer rate, which expedited the generation of hydroxyl radicals (˙OH, a kind of reactive oxygen species (ROS)) in the presence of H2O2. The persistence and high intensity of ˙OH generation were proven, which would endow Co@Fe MOG with a certain antibacterial ability, promoting the healing of bacteria-infected wounds. In conclusion, this study contributes to the development efforts toward the application systems of nanozymes for marker detection and antibacterial activity.


Assuntos
Antibacterianos , Cobalto , Colorimetria , Géis , Ferro , Peroxidase , Antibacterianos/farmacologia , Antibacterianos/química , Ferro/química , Cobalto/química , Colorimetria/métodos , Géis/química , Peroxidase/metabolismo , Peroxidase/química , Porosidade , Estruturas Metalorgânicas/química , Estruturas Metalorgânicas/farmacologia , Peróxido de Hidrogênio/análise , Peróxido de Hidrogênio/metabolismo , Peróxido de Hidrogênio/química , Testes de Sensibilidade Microbiana , Escherichia coli/efeitos dos fármacos , Escherichia coli/enzimologia , Staphylococcus aureus/efeitos dos fármacos , Tamanho da Partícula , Catálise
17.
Molecules ; 29(9)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38731608

RESUMO

In this paper, Cu-BTC derived mesoporous CuS nanomaterial (m-CuS) was synthesized via a two-step process involving carbonization and sulfidation of Cu-BTC for colorimetric glutathione detection. The Cu-BTC was constructed by 1,3,5-benzenetri-carboxylic acid (H3BTC) and Cu2+ ions. The obtained m-CuS showed a large specific surface area (55.751 m2/g), pore volume (0.153 cm3/g), and pore diameter (15.380 nm). In addition, the synthesized m-CuS exhibited high peroxidase-like activity and could catalyze oxidation of the colorless substrate 3,3',5,5'-tetramethylbenzidine to a blue product. Peroxidase-like activity mechanism studies using terephthalic acid as a fluorescent probe proved that m-CuS assists H2O2 decomposition to reactive oxygen species, which are responsible for TMB oxidation. However, the catalytic activity of m-CuS for the oxidation of TMB by H2O2 could be potently inhibited in the presence of glutathione. Based on this phenomenon, the colorimetric detection of glutathione was demonstrated with good selectivity and high sensitivity. The linear range was 1-20 µM and 20-300 µM with a detection limit of 0.1 µM. The m-CuS showing good stability and robust peroxidase catalytic activity was applied for the detection of glutathione in human urine samples.


Assuntos
Colorimetria , Cobre , Glutationa , Peróxido de Hidrogênio , Nanoestruturas , Glutationa/análise , Glutationa/química , Colorimetria/métodos , Cobre/química , Nanoestruturas/química , Catálise , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Porosidade , Oxirredução , Ácidos Ftálicos/química , Humanos , Benzidinas/química , Limite de Detecção
18.
Talanta ; 276: 126202, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38743968

RESUMO

Chemiluminescence (CL) is a self-illumination phenomenon that involves the emission of light from chemical reactions, and it provides favorable spatial and temporal information on biological processes. However, it is still a great challenge to construct effective CL sensors that equip strong CL intensity, long emission wavelength, and persistent luminescence for deep tissue imaging. Here, we report a liposome encapsulated polymer dots (Pdots)-based system using catalytic CL substrates (L-012) as energy donor and fluorescent polymers and dyes (NIR 695) as energy acceptors for efficient Near-infrared (NIR) CL in vivo imaging. Thanks to the modulation of paired donor and acceptor distance and the slow diffusion of biomarker by liposome, the Pdots show a NIR emission wavelength (λ em, max = 720 nm), long CL duration (>24 h), and a high chemiluminescence resonance energy transfer efficiency (46.5 %). Furthermore, the liposome encapsulated Pdots possess excellent biocompatibility, sensitive response to H2O2, and persistent whole-body NIR CL imaging in the drug-induced inflammation and the peritoneal metastatic tumor mouse model. In a word, this NIR-II CL nanoplatform with long-lasting emission and high spatial-temporal resolution will be a concise strategy in deep tissue imaging and clinical diagnostics.


Assuntos
Raios Infravermelhos , Lipossomos , Animais , Lipossomos/química , Camundongos , Catálise , Medições Luminescentes/métodos , Imagem Óptica , Corantes Fluorescentes/química , Humanos , Polímeros/química , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Luminescência , Pontos Quânticos/química , Camundongos Endogâmicos BALB C
19.
Anal Chim Acta ; 1307: 342627, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719406

RESUMO

BACKGROUND: Hydrogen peroxide (H2O2) is an important reactive oxygen species (ROS) molecule involved in cell metabolism regulation, transcriptional regulation, and cytoskeleton remodeling. Real-time monitoring of H2O2 levels in live cells is of great significance for disease prevention and diagnosis. RESULTS: We utilized carbon cloth (CC) as the substrate material and employed a single-atom catalysis strategy to prepare a flexible self-supported sensing platform for the real-time detection of H2O2 secreted by live cells. By adjusting the coordination structure of single-atom sites through P and S doping, a cobalt single-atom nanoenzyme Co-NC/PS with excellent peroxidase-like activity was obtained. Furthermore, we explored the enzyme kinetics and possible catalytic mechanism of Co-NC/PS. Due to the excellent flexibility, high conductivity, strong adsorption performance of carbon cloth, and the introduction of non-metallic atom-doped active sites, the developed Co-NC/PS@CC exhibited ideal sensing performance. Experimental results showed that the linear response range for H2O2 was 1-17328 µM, with a detection limit (LOD) of 0.1687 µM. Additionally, the sensor demonstrated good reproducibility, repeatability, anti-interference, and stability. SIGNIFICANCE: The Co-NC/PS@CC prepared in this study has been successfully applied for detecting H2O2 secreted by MCF-7 live cells, expanding the application of single-atom nanoenzymes in live cell biosensing, with significant implications for health monitoring and clinical diagnostics.


Assuntos
Cobalto , Técnicas Eletroquímicas , Peróxido de Hidrogênio , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Cobalto/química , Humanos , Técnicas Eletroquímicas/métodos , Células MCF-7 , Carbono/química , Limite de Detecção , Técnicas Biossensoriais/métodos
20.
Anal Chim Acta ; 1309: 342701, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38772662

RESUMO

BACKGROUND: Nanozymes, a new class of nanomaterials, have emerged as promising substitutes for enzymes in biosensor design due to their exceptional stability, affordability, and ready availability. While nanozymes address many limitations of natural enzymes, they still face challenges, particularly in achieving the catalytic activity levels of their natural counterparts. This indicates the need for enhancing the sensitivity of biosensors based on nanozymes. The catalytic activity of nanozyme can be significantly improved by regulating its size, morphology, and surface composition of nanomaterial. RESULTS: In this work, a kind of hollow core-shell structure was designed to enhance the catalytic activity of nanozymes. The hollow core-shell structure material consists of a nanozymes core layer, a hollow layer, and a MOF shell layer. Taking the classic peroxidase like Fe3O4 as an example, the development of a novel nanozyme@MOF, specifically p-Fe3O4@PDA@ZIF-67, is detailed, showcasing its application in enhancing the sensitivity of sensors based on Fe3O4 nanozymes. This innovative nanocomposite, featuring that MOF layer was designed to adsorb the signal molecules of the sensor to improve the utilization rate of reactive oxygen species generated by the nanozymes catalyzed reactions and the hollow layer was designed to prevent the active sites of nanozymes from being cover by the MOF layer. The manuscript emphasizes the nanocomposite's remarkable sensitivity in detecting hydrogen peroxide (H2O2), coupled with high specificity and reproducibility, even in complex environments like milk samples. SIGNIFICANCE AND NOVELTY: This work firstly proposed and proved that Fe3O4 nanozyme@MOF with hollow layer structure was designed to improve the catalytic activity of the Fe3O4 nanozyme and the sensitivity of the sensors based on Fe3O4 nanozyme. This research marks a significant advancement in nanozyme technology, demonstrating the potential of structural innovation in creating high-performance, sensitive, and stable biosensors for various applications.


Assuntos
Técnicas Biossensoriais , Estruturas Metalorgânicas , Técnicas Biossensoriais/métodos , Estruturas Metalorgânicas/química , Óxido Ferroso-Férrico/química , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Indóis/química , Catálise , Limite de Detecção , Nanoestruturas/química , Nanocompostos/química , Imidazóis , Polímeros , Zeolitas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA