Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 943
Filtrar
1.
Water Res ; 256: 121594, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38615603

RESUMO

Membrane distillation (MD) has emerged as a promising technology for desalination and concentration of hypersaline brine. However, the efficient preparation of a structurally stable and salinity-resistant membrane remains a significant challenge. In this study, an amphiphobic polytetrafluoroethylene nanofibrous membrane (PTFE NFM) with exceptional resistance to scaling has been developed, using an energy-efficient method. This innovative approach avoids the high-temperature sintering treatment, only involving electrospinning with PTFE/PVA emulsion and subsequent low-temperature crosslinking and fluorination. The impact of the PVA and PTFE contents, as well as the crosslinking and subsequent fluorination on the morphology and MD performance of the NFM, were systematically investigated. The optimized PTFE NFM displayed robust amphiphobicity, boasting a water contact angle of 155.2º and an oil contact angle of 132.7º. Moreover, the PTFE NFM exhibited stable steam flux of 52.1 L·m-2·h-1 and 26.7 L·m-2·h-1 when fed with 3.5 wt % and 25.0 wt % NaCl solutions, respectively, and an excellent salt rejection performance (99.99 %, ΔT = 60 °C) in a continuous operation for 24 h, showing exceptional anti-scaling performance. It also exhibited stable anti-wetting and anti-fouling properties against surfactants (sodium dodecyl sulfate) and hydrophobic contaminants (diesel oil). These results underscore the significant potential of the PTFE nanofibrous membrane for practical applications in desalination, especially in hypersaline or polluted aqueous environments.


Assuntos
Destilação , Membranas Artificiais , Nanofibras , Politetrafluoretileno , Politetrafluoretileno/química , Nanofibras/química , Destilação/métodos , Halogenação , Purificação da Água/métodos
2.
Lab Chip ; 24(9): 2468-2484, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38563430

RESUMO

Three-dimensional (3D) in vitro models, superior in simulating physiological conditions compared to 2D models, offer intricate cell-cell and cell-ECM interactions with diverse signaling cues like fluid shear stress and growth factor gradients. Yet, developing 3D tissue barrier models, specifically perfusable luminal structures with dense, multicellular constructs maintained for extended durations with oxygen and nutrients, remains a technical challenge. Here, we describe a molding-based approach for the fabrication of free-standing, perfusable, high cellular density tissue constructs using a self-assembly and migration process to form functional barriers. This technique utilizes a polytetrafluoroethylene (PTFE)-coated stainless-steel wire, held by stainless steel needles, as a template for a perfusable channel within an elongated PDMS well. Upon adding a bio-ink mix of cells and collagen, it self-assembles into a high cell density layer conformally around the wire. Removing the wire reveals a hollow construct, connectable to an inlet and outlet for perfusion. This scalable method allows creating varied dimensions and multicellular configurations. Notably, post-assembly, cells such as human umbilical vein endothelial cells (HUVECs) migrate to the surface and form functional barriers with adherens junctions. Permeability tests and fluorescence imaging confirm that these constructs closely mimic in vivo endothelial barrier permeability, exhibiting the lowest permeability among all in vitro models in the literature. Unlike traditional methods involving uneven post-seeding of endothelial cells leading to subpar barriers, our approach is a straightforward alternative for fabricating complex perfusable 3D tissue constructs and effective tissue barriers for use in various applications, including tissue engineering, drug screening, and disease modeling.


Assuntos
Movimento Celular , Humanos , Movimento Celular/efeitos dos fármacos , Células Endoteliais da Veia Umbilical Humana , Politetrafluoretileno/química , Membranas Artificiais , Dimetilpolisiloxanos/química , Desenho de Equipamento
3.
Biomech Model Mechanobiol ; 23(3): 845-860, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38361084

RESUMO

In complex cardiovascular surgical reconstructions, conduit materials that avoid possible large-scale structural deformations should be considered. A fundamental mode of mechanical complication is torsional buckling which occurs at the anastomosis site due to the mechanical instability, leading surgical conduit/patch surface deformation. The objective of this study is to investigate the torsional buckling behavior of commonly used materials and to develop a practical method for estimating the critical buckling rotation angle under physiological intramural vessel pressures. For this task, mechanical tests of four clinically approved materials, expanded polytetrafluoroethylene (ePTFE), Dacron, porcine and bovine pericardia, commonly used in pediatric cardiovascular surgeries, are conducted (n = 6). Torsional buckling initiation tests with n = 4 for the baseline case (L = 7.5 cm) and n = 3 for the validation of ePTFE (L = 15 cm) and Dacron (L = 15 cm and L = 25 cm) for each are also conducted at low venous pressures. A practical predictive formulation for the buckling potential is proposed using experimental observations and available theory. The relationship between the critical buckling rotation angle and the lumen pressure is determined by balancing the circumferential component of the compressive principal stress with the shear stress generated by the modified critical buckling torque, where the modified critical buckling torque depends linearly on the lumen pressure. While the proposed technique successfully predicted the critical rotation angle values lying within two standard deviations of the mean in the baseline case for all four materials at all lumen pressures, it could reliably predict the critical buckling rotation angles for ePTFE and Dacron samples of length 15 cm with maximum relative errors of 31% and 38%, respectively, in the validation phase. However, the validation of the performance of the technique demonstrated lower accuracy for Dacron samples of length 25 cm at higher pressure levels of 12 mmHg and 15 mmHg. Applicable to all surgical materials, this formulation enables surgeons to assess the torsional buckling potential of vascular conduits noninvasively. Bovine pericardium has been found to exhibit the highest stability, while Dacron (the lowest) and porcine pericardium have been identified as the least stable with the (unitless) torsional buckling resistance constants, 43,800, 12,300 and 14,000, respectively. There was no significant difference between ePTFE and Dacron, and between porcine and bovine pericardia. However, both porcine and bovine pericardia were found to be statistically different from ePTFE and Dacron individually (p < 0.0001). ePTFE exhibited highly nonlinear behavior across the entire strain range [0, 0.1] (or 10% elongation). The significant differences among the surgical materials reported here require special care in conduit construction and anastomosis design.


Assuntos
Teste de Materiais , Animais , Bovinos , Estresse Mecânico , Politetrafluoretileno/química , Suínos , Pressão , Criança , Humanos , Fenômenos Biomecânicos , Prótese Vascular , Torque , Pericárdio/fisiologia
4.
Environ Sci Pollut Res Int ; 30(56): 118736-118753, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37917268

RESUMO

In this work, different iron-based cathode materials were prepared using two different approaches: a novel one-step approach, which involved the incorporation of iron oxide with Printex® L6 carbon/PTFE (PL6C/PTFE) on bare carbon felt (CF) and a two-step approach, where iron oxide is deposited onto CF previously modified with PL6C/PTFE. The results obtained from the physical characterization indicated that the presence of iron oxide homogeneously dispersed on the felt fibers with the CF 3-D network kept intact in the one-step approach; whereas the formation of iron oxide aggregates between the felt fibers for material obtained using the two-step approach. Among the iron oxide-based cathodes investigated, the iron-incorporated electrode exhibited the greatest efficiency in terms of the removal and mineralization of norfloxacin (NOR) under neutral pH (complete NOR removal in less than 30 min with around 50% mineralization after 90 min). The findings of this study show that the low cost and simple-to-prepare iron-modified carbon-based materials in HEF process led to the enhanced degradation of organic contaminants in aqueous solutions.


Assuntos
Carbono , Poluentes Químicos da Água , Norfloxacino , Oxirredução , Poluentes Químicos da Água/análise , Peróxido de Hidrogênio/química , Ferro/química , Eletrodos , Politetrafluoretileno/química
5.
Colloids Surf B Biointerfaces ; 229: 113449, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37506438

RESUMO

Without differentiated inner and outer biological function, expanded polytetrafluoroethylene (ePTFE) small-diameter (<6 mm) artificial blood vessels would fail in vivo due to foreign body rejection, thrombosis, and hyperplasia. In order to synergistically promote endothelialization, anti-thrombogenicity, and anti-inflammatory function, we modified the inner and outer surface of ePTFE, respectively, by grafting functional biomolecules, such as heparin and epigallocatechin gallate (EGCG), into the inner surface and polyethyleneimine and rapamycin into the outer surface via layer-by-layer self-assembly. Fourier-transform infrared spectroscopy showed the successful incorporation of EGCG, heparin, and rapamycin. The collaborative release profile of heparin and rapamycin lasted for 42 days, respectively. The inner surface promoted human umbilical vein endothelial cells (HUVECs) adhesion and growth and that the outer surface inhibited smooth muscle cells growth and proliferation. The modified ePTFE effectively regulated the differentiation behavior of RAW264.7, inhibited the expression of proinflammatory mediator TNF-α, and up-regulated the expression of anti-inflammatory genes Arg1 and Tgfb-1. The ex vivo circulation results indicated that the occlusions and total thrombus weight of modified ePTFE was much lower than that of the thrombus formed on the ePTFE, presenting good anti-thrombogenic properties. Hence, the straightforward yet efficient synergistic surface functionalization approach presented a potential resolution for the prospective clinical application of small-diameter ePTFE blood vessel grafts.


Assuntos
Prótese Vascular , Trombose , Humanos , Politetrafluoretileno/farmacologia , Politetrafluoretileno/química , Estudos Prospectivos , Heparina/farmacologia , Células Endoteliais da Veia Umbilical Humana , Trombose/tratamento farmacológico , Sirolimo
6.
Sci Rep ; 13(1): 9696, 2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-37322021

RESUMO

Polytetrafluoroethylene (PTFE) is one of the most significant fluoropolymers, and one of the most recent initiatives is to increase its performance by using metal oxides (MOs). Consequently, the surface modifications of PTFE with two metal oxides (MOs), SiO2 and ZnO, individually and as a mixture of the two MOs, were modeled using density functional theory (DFT). The B3LYPL/LANL2DZ model was used in the studies conducted to follow up the changes in electronic properties. The total dipole moment (TDM) and HOMO/LUMO band gap energy (∆E) of PTFE, which were 0.000 Debye and 8.517 eV respectively, were enhanced to 13.008 Debye and 0.690 eV in the case of PTFE/4ZnO/4SiO2. Moreover, with increasing nano filler (PTFE/8ZnO/8SiO2), TDM changed to 10.605 Debye and ∆E decreased to 0.273 eV leading to further improvement in the electronic properties. The molecular electrostatic potential (MESP) and quantitative structure activity relationship (QSAR) studies revealed that surface modification of PTFE with ZnO and SiO2 increased its electrical and thermal stability. The improved PTFE/ZnO/SiO2 composite can, therefore, be used as a self-cleaning layer for astronaut suits based on the findings of relatively high mobility, minimal reactivity to the surrounding environment, and thermal stability.


Assuntos
Nanocompostos , Óxido de Zinco , Óxido de Zinco/química , Dióxido de Silício/química , Relação Quantitativa Estrutura-Atividade , Politetrafluoretileno/química
7.
PLoS One ; 18(3): e0282352, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37000783

RESUMO

Superhydrophobic surfaces (SHS) are attracting attention in many fields owing to their excellent advantages such as anti-freezing, corrosion prevention, and self-cleaning. However, to modify the surface structure, environmental pollution caused by complex processes and chemical treatment must be considered. In this study, the surface of polytetrafluoroethylene (PTFE) was plasma-treated using oxygen and argon plasma to change the surface structure without a complicated process. The PTFE surface was treated in two ways: plasma etching (PE) and reactive ion etching (RIE). The contact angle of the conventional PTFE surface was 113.8 ± 1.4°, but the contact angle of the manufactured surface was 152.3 ± 1.7° and 172.5 ± 1.2°. The chemical composition and physical structure of the samples produced were compared. The treated specimens had the same chemical composition as the specimen before treatment and exhibited differences in their surface structures. Therefore, it was determined that the change in the water repellency was due to the surface structure. After PE treatment, the specimen surface had a mountain range-like structure, and the RIE specimen had a more detailed structure than the PE specimen. The contact rate of water droplets decreased due to the difference in the structure of the specimen before and after treatment, and the increase in the surface contact angle was manifested. In order to confirm that the plasma treatment reduces surface energy, the shape of the liquid collision was observed using a high-speed camera, and the contact time was calculated to confirm water repellency. The contact time of the PE and RIE specimen was 24 milli-second (ms) and 18 ms, respectively. The high contact angle and low sliding angle of the RIE specimen made it easy to restore surface cleanliness in a self-cleaning experiment using graphite.


Assuntos
Politetrafluoretileno , Água , Molhabilidade , Propriedades de Superfície , Politetrafluoretileno/química , Água/química
8.
J Surg Res ; 279: 491-504, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35842974

RESUMO

INTRODUCTION: There is a growing need for small-diameter (<6 mm) off-the-shelf synthetic vascular conduits for different surgical bypass procedures, with actual synthetic conduits showing unacceptable thrombosis rates. The goal of this study was to build vascular grafts with better compliance than standard synthetic conduits and with an inner layer stimulating endothelialization while remaining antithrombogenic. METHODS: Tubular vascular conduits made of a scaffold of polyurethane/polycaprolactone combined with a bioactive coating based on chondroitin sulfate (CS) were created using electrospinning and plasma polymerization. In vitro testing followed by a comparative in vivo trial in a sheep model as bilateral carotid bypasses was performed to assess the conduits' performance compared to the actual standard. RESULTS: In vitro, the novel small-diameter (5 mm) electrospun vascular grafts coated with chondroitin sulfate (CS) showed 10 times more compliance compared to commercial expanded polytetrafluoroethylene (ePTFE) conduits while maintaining adequate suturability, burst pressure profiles, and structural stability over time. The subsequent in vivo trial was terminated after electrospun vascular grafts coated with CS showed to be inferior compared to their expanded polytetrafluoroethylene counterparts. CONCLUSIONS: The inability of the experimental conduits to perform well in vivo despite promising in vitro results may be related to the low porosity of the grafts and the lack of rapid endothelialization despite the presence of the CS coating. Further research is warranted to explore ways to improve electrospun polyurethane/polycaprolactone scaffold in order to make it prone to transmural endothelialization while being resistant to strenuous conditions.


Assuntos
Poliuretanos , Enxerto Vascular , Animais , Prótese Vascular , Sulfatos de Condroitina , Politetrafluoretileno/química , Ovinos
9.
Soft Matter ; 18(22): 4315-4324, 2022 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-35621021

RESUMO

The use of polymeric materials in biomedical applications requires a judicious control of surface properties as they are directly related to cellular interactions and biocompatibility. The most desired chemical surface properties include hydrophilicity and the presence of functional groups for surface modification. In this work, we describe a method to graft a highly stable, ultra-thin, amine-functional hydrogel layer onto highly inert surfaces of poly(tetrafluoroethylene) (PTFE), poly(vinylidene fluoride) (PVDF), and poly(4-methyl-1-pentene) (PMP or TPX). Covalent grafting is realized with hydrophilic poly(vinylamine-co-acetamide)s by C-H insertion crosslinking (CHic) chemistry initiated by UV light. These polyvinylamides carry tetrafluorophenyl azide groups as photo or thermo activated binding sites and contain further free amine groups, which can be used to bind peptides such as biological ligands, polysaccharides, or other hydrogel layers. The covalently bound surface layers resist intensive Soxhlet extraction confirming the stability of the coating. Fluorescent staining verified the accessibility of free primary amine groups, which can be used for the functionalization of the surface with bioactive molecules. The coating demonstrates hydrophobic wetting behavior when conditioned in air and hydrophilic wetting behavior when conditioned in water showing the presence of loosely crosslinked polymer chains that can re-orient. We believe that the reported application of CHic for the surface modification of fluorinated polymers like PTFE and PVDF as well as TPX can form the basis for advanced biocompatible and biofunctional surface engineering.


Assuntos
Hidrogéis , Polímeros , Aminas , Polímeros de Fluorcarboneto , Metilgalactosídeos , Polímeros/química , Politetrafluoretileno/química , Polivinil/química , Propriedades de Superfície
10.
Int J Mol Sci ; 23(6)2022 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-35328404

RESUMO

Bacterial contamination of the membranes used during guided bone regeneration directly influences the outcome of this procedure. In this study, we analyzed the early stages of bacterial adhesion on two commercial dense polytetrafluoroethylene (d-PTFE) membranes in order to identify microstructural features that led to different adhesion strengths. The microstructure was investigated by X-ray diffraction (XRD), differential scanning calorimetry (DSC), and Fourier transform infrared (FTIR). The surface properties were analyzed by atomic force microscopy (AFM), scanning electron microscopy (SEM), and surface free energy (SFE) measurements. Bacterial properties were determined using the microbial adhesion to solvents (MATS) assay, and bacterial surface free energy (SFE) was measured spectrophotometrically. The adhesion of four species of oral bacteria (Streptococcus mutans, Streptococcus oralis, Aggregatibacter actinomycetemcomitas, and Veilonella parvula) was studied on surfaces with or without the artificial saliva coating. The results indicated that the degree of crystallinity (78.6% vs. 34.2%, with average crystallite size 50.54 nm vs. 32.86 nm) is the principal feature promoting the adhesion strength, through lower nanoscale roughness and possibly higher surface stiffness. The spherical crystallites ("warts"), observed on the surface of the highly crystalline sample, were also identified as a contributor. All bacterial species adhered better to a highly crystalline membrane (around 1 log10CFU/mL difference), both with and without artificial saliva coating. Our results show that the changes in polymer microstructure result in different antimicrobial properties even for chemically identical PTFE membranes.


Assuntos
Polímeros , Politetrafluoretileno , Aderência Bacteriana , Membranas Artificiais , Microscopia Eletrônica de Varredura , Politetrafluoretileno/química , Saliva Artificial , Streptococcus mutans , Propriedades de Superfície
11.
Opt Express ; 29(24): 39214-39226, 2021 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-34809290

RESUMO

Micro-lens array, an artificial compound eye vision system, provides a wide field of view and multi-perspective view. However, it has not been adopted as a computer vision application due to its limited visible range and high optical interference. In this research, a novel fabrication method for the flexible polydimethylsiloxane micro-lens array with a polytetrafluoroethylene light screen-aperture integrated layer was established by the simple protrusion method. The integrated layer provided longer visible range by one meter while maintaining the wide field-of-view of 100 °. The resulting images were used for obtaining depth information of a target as an example and for analyzing the rectangular and hexagonal arrangements of the micro-lenses for the future applications. With the improved visual range, wide field-of-view and flexibility, the fabricated micro-lens array can be applied to the small and curved CMOS image sensors in the future.


Assuntos
Biomimética/instrumentação , Técnicas Biossensoriais/instrumentação , Olho Composto de Artrópodes/fisiologia , Dimetilpolisiloxanos/química , Cristalino/fisiologia , Politetrafluoretileno/química , Animais , Biomimética/métodos , Desenho de Equipamento , Luz
12.
ACS Appl Mater Interfaces ; 13(39): 46840-46847, 2021 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-34546028

RESUMO

Fiber-based nanogenerators have great potential applications in wearable electronics such as portable nanodevices, e-skin, and artificial intelligence system. Here, we report a kind of fiber-based electret nanogenerator (FENG) with a semisupported core-shell structure. Owing to its unique structure, the open-circuit voltage and short-circuit current of the FENG reach 40 V and 0.6 µA, respectively, under a short working distance (∼25 µm). No obvious degradation of the output performance under a long-time continuous work (>16 h) and different humidity environments (20-95%) is observed, which demonstrates the FENG's good reliability and stability. Many universal materials, such as cotton rope, conductive sewing thread, and polyvinyl chloride tube, have been successfully used to fabricate FENG. Meanwhile, the FENG-based wearable fabric has been successfully developed to effectively harvest mechanical energy of human motion. The FENG is highly effective, reliable, and stable, promoting the development of fiber-based nanogenerators and their applications in self-powered wearable electronics.


Assuntos
Fontes de Energia Elétrica , Dispositivos Eletrônicos Vestíveis , Cobre/química , Dimetilpolisiloxanos/química , Eletrodos , Humanos , Movimento , Politetrafluoretileno/química , Prata/química , Têxteis
13.
J Mater Chem B ; 9(36): 7409-7422, 2021 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-34551061

RESUMO

Cardiovascular disease (CVD) poses serious health concerns worldwide. The lack of transplantable vascular grafts is an unmet clinical need in the surgical treatment of CVD. Although expanded polytetrafluoroethylene (ePTFE) vascular grafts have been used in clinical practice, a low long-term patency rate in small-diameter transplantation application is still the biggest challenge. Thus, surface modification of ePTFE is sought after. In this study, polydopamine (PDA) was used to improve the hydrophilia and provide immobilization sites in ePTFE. Bivalirudin (BVLD), a direct thrombin inhibitor, was used to enhance the anti-thrombotic activity of ePTFE. The peptides derived from extracellular matrix proteins were used to elevate the bioactivity of ePTFE. The morphology, chemical composition, peptide modified strength, wettability, and hemocompatibility of modified ePTFE vascular grafts were investigated. Then, an endothelial cell proliferation assay was used to evaluate the best co-modification strategy of the ePTFE vascular graft in vitro. Since a large animal could relatively better mimic human physiology, we chose a porcine carotid artery replacement model in the current study. The results showed that the BVLD/REDV co-modified ePTFE vascular grafts had a satisfactory patency rate (66.7%) and a higher endothelial cell coverage ratio (70%) at 12 weeks after implantation. This may offer an opportunity to produce a multi-biofunctional ePTFE vascular graft, thereby yielding a potent product to meet the clinical needs.


Assuntos
Prótese Vascular , Materiais Revestidos Biocompatíveis/química , Politetrafluoretileno/química , Animais , Antitrombinas/química , Antitrombinas/uso terapêutico , Artérias Carótidas/patologia , Artérias Carótidas/cirurgia , Lesões das Artérias Carótidas/terapia , Proliferação de Células/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/farmacologia , Materiais Revestidos Biocompatíveis/uso terapêutico , Modelos Animais de Doenças , Células Endoteliais/citologia , Células Endoteliais/metabolismo , Hirudinas/química , Indóis/química , Masculino , Fragmentos de Peptídeos/química , Fragmentos de Peptídeos/uso terapêutico , Polímeros/química , Proteínas Recombinantes/química , Proteínas Recombinantes/uso terapêutico , Suínos , Porco Miniatura , Trombose/tratamento farmacológico , Molhabilidade
14.
Biomolecules ; 11(8)2021 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-34439772

RESUMO

A prosthetic vascular graft that induces perigraft tissue incorporation may effectively prevent serious sequelae such as seroma formation and infection. Radiation-crosslinked gelatin hydrogel (RXgel) mimics the chemical and physical properties of the in vivo extracellular matrix and may facilitate wound healing by promoting tissue organization. Fibroblasts cultured on RXgel actively migrated into the gel for up to 7 days. RXgels of three different degrees of hardness (Rx[10], soft; Rx[15], middle; Rx[20], hard) were prepared, and small disc-like samples of RXgels were implanted into rats. In vitro and in vivo results indicated that Rx[10] was too soft to coat vascular grafts. Thus, expanded polytetrafluoroethylene (ePTFE) vascular grafts coated with RXgel were developed using Rx[15] and Rx[20] gels, and ring-shaped slices of the graft were implanted into rats. Alpha-smooth muscle actin (αSMA) and type III collagen (Col-III) levels were detected by immunohistochemistry. Immunohistochemical staining for αSMA and Col-III demonstrated that RXgel-coated vascular grafts induced more granulation tissue than non-coated grafts on days 14 and 28 after implantation. RXgel-coated ePTFE vascular grafts may provide a solution for patients by reducing poor perigraft tissue incorporation.


Assuntos
Prótese Vascular , Fibroblastos/metabolismo , Gelatina/química , Hidrogéis/química , Politetrafluoretileno/química , Enxerto Vascular/instrumentação , Células 3T3 , Actinas/metabolismo , Animais , Movimento Celular , Materiais Revestidos Biocompatíveis , Reagentes de Ligações Cruzadas/química , Hiperplasia , Imuno-Histoquímica , Masculino , Camundongos , Ratos , Ratos Sprague-Dawley , Seroma/patologia
15.
Carbohydr Polym ; 270: 118401, 2021 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-34364634

RESUMO

Multicolored superhydrophobic coating with high durability has been receiving tremendous attention in decorative applications. Herein, a facile method to fabricate multicolored superhydrophobic coating with excellent robustness has been developed by using cellulose and chitosan. The multicolored coatings can be obtained through single dyeing or mixed dyeing based on three primary dyes. The coating can be applied on hard substrates (e.g. glass, aluminum sheet) and soft substrates (e.g. cotton fabric) by diverse methods including spraying, dip-coating and painting. The colorful coating firmly adheres to the substrates due to the multiple interactions (siloxane covalent bonds and hydrogen bonds). The colorful coating exhibits water-repellant behaviors and can withstand sandpaper abrasion, tape-peeling cycles, water impact, salt spray test and UV environments. Furthermore, the multicolored coating can be used as a new type of pigment for painting on different substrates and is expected to have a huge potential application in technological design or decoration.


Assuntos
Biomassa , Celulose/química , Quitosana/química , Corantes/química , Interações Hidrofóbicas e Hidrofílicas , Alumínio/química , Cor , Vidro/química , Pinturas , Politetrafluoretileno/química , Propriedades de Superfície , Têxteis , Água/química , Zeolitas/química
16.
Sci Rep ; 11(1): 16321, 2021 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-34381065

RESUMO

Vascular bypass surgery in children differs significantly from adults. It is a rarely performed procedure in the setting of trauma and tumor surgery. Besides technical challenges to reconstruct the small and spastic vessels, another concern in bypass grafting is the adequate limb length growth over time. The primary aim of this study was to assess long-term outcome after pediatric bypass grafting, in a single academic center, focusing on potential effects on limb development. In this retrospective cohort analyses we included all pediatric patients undergoing vascular bypass grafting at our department between 2002 and 2017. All patients ≤ 18 years suffered a traumatic injury or underwent a tumor resection of the lower or upper limb. The youngest female patient was 0.4 years, the youngest male patient was 3.5 years. During the observation period, 33 pediatric patients underwent vascular repair, whereby 15 patients underwent bypass grafting. Median overall follow-up was 4.7 years (IQR ± 9). 8 patients (53%) had a traumatic injury (traumatic surgery group) and 7 patients had a planned orthopedic tumor resection (orthopedic surgery group). In 13/15 (87%) a great saphenous vein (GSV) graft and in 2/15 (13%) a Gore-Tex graft was used for bypassing. Both Gore-Tex grafts showed complete occlusion 12 and 16 years after implantation. No patient died in the early postoperative phase (< 30 days), however 3/7 (43%) in the orthopedic group died during follow-up. Revision surgery had to be performed in 1/15 (7%) patients. A functional use of the extremity was reported in all patients. Normal limb length growth according to the contralateral site, and therefore bypass growth, could be documented in 14/15 patients. Children are surgically challenging. In our study, surgery by a specialized vascular surgery team using GSV grafts led to adequate limb length and bypass growth, and we observed no functional restrictions.


Assuntos
Oclusão de Enxerto Vascular/fisiopatologia , Neoplasias/fisiopatologia , Criança , Feminino , Oclusão de Enxerto Vascular/cirurgia , Humanos , Extremidade Inferior/fisiopatologia , Masculino , Neoplasias/cirurgia , Politetrafluoretileno/química , Estudos Retrospectivos , Veia Safena/fisiopatologia , Veia Safena/cirurgia , Resultado do Tratamento , Extremidade Superior/fisiopatologia , Enxerto Vascular/métodos , Grau de Desobstrução Vascular/fisiologia , Procedimentos Cirúrgicos Vasculares/métodos
17.
Biomed Mater ; 16(6)2021 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-34406979

RESUMO

In situtissue engineering is an emerging field aiming at the generation of ready-to-use three-dimensional tissues. One solution to supply a proper vascularization of larger tissues to provide oxygen and nutrients is the arteriovenous loop (AVL) model. However, for this model, suitable scaffold materials are needed that are biocompatible/non-immunogenic, slowly degradable, and allow vascularization. Here, we investigate the suitability of the known gelatin methacryloyl (GelMA)-based hydrogel forin-situtissue engineering utilizing the AVL model. Rat AVLs are embedded by two layers of GelMA hydrogel in an inert PTFE chamber and implanted in the groin. Constructs were explanted after 2 or 4 weeks and analyzed. For this purpose, gross morphological, histological, and multiphoton microscopic analysis were performed. Immune response was analyzed based on anti-CD68 and anti-CD163 staining of immune cells. The occurrence of matrix degradation was assayed by anti-MMP3 staining. Vascularization was analyzed by anti-α-smooth muscle actin staining, multiphoton microscopy, as well as expression analysis of 53 angiogenesis-related proteins utilizing a proteome profiler angiogenesis array kit. Here we show that GelMA hydrogels are stable for at least 4 weeks in the rat AVL model. Furthermore, our data indicate that GelMA hydrogels are biocompatible. Finally, we provide evidence that GelMA hydrogels in the AVL model allow connective tissue formation, as well as vascularization, introducing multiphoton microscopy as a new methodology to visualize neovessel formation originating from the AVL. GelMA is a suitable material forin situandin vivoTE in the AVL model.


Assuntos
Materiais Biocompatíveis , Gelatina , Metacrilatos , Neovascularização Fisiológica/fisiologia , Engenharia Tecidual/métodos , Animais , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Gelatina/química , Gelatina/farmacologia , Masculino , Metacrilatos/química , Metacrilatos/farmacologia , Microscopia de Fluorescência por Excitação Multifotônica , Modelos Cardiovasculares , Politetrafluoretileno/química , Proteoma/metabolismo , Ratos
18.
Ann Vasc Surg ; 77: 280-287, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34411679

RESUMO

BACKGROUND: To evaluate the quality of in vitro fenestrations during in situ fenestration (ISF) and investigate the differences between needle and laser puncture in current stent-grafts. METHODS: An in vitro study evaluated the damage created by needle ISF on stent-graft fabrics versus laser ISF. Fenestrations were made in 5 different commercially available stent-grafts, including polyester stent-grafts (Relay, Valiant and Hercules) and expanded polytetrafluoroethylene (ePTFE) stent-grafts (TAG and Ankura). Each stent-graft received fenestration by needle and laser separately, followed by gradual dilation (4 mm, 6 mm, 8 mm, and 10 mm sequentially) of noncompliant balloons. Quantitative and qualitative evaluations including fenestration diameter, area, shape and margins were conducted using light microscopy and scanning electron microscope. RESULTS: The primary fenestrations created by needle were slit-like with visible cut-off fibers in polyester stent-grafts and were almost circular with clear margins in ePTFE stent-grafts; those created by laser were squared or elliptical with ragged edges and burned fibers in all the stent-grafts. Fabric debris and toxic particles due to burning of the material were generated during laser-assisted fenestration. The Primary holes in polyester stent-grafts (Relay, Valiant and Hercules) by needle showed smaller area (0.05 mm2 vs. 0.22 mm2, 0.52 mm2 vs. 0.70 mm2 and 0.28 mm2 vs. 0.46 mm2; P < 0.01) and worse shape (0.93 vs. 2.46, 1.17 vs. 2.33 and 0.93 vs. 2.47; P < 0.01) than those by laser, while larger area (0.67 vs.0.43, 0.59 vs.0.45; P < 0.05), better shape (3.93 vs. 2.53, 3.90 vs. 2.93; P < 0.05) and better margin (3.83 vs. 2.47, 3.83 vs. 2.53; P < 0.05) in ePTFE stent-grafts (TAG and Ankrura). After gradual balloon dilation, the final holes showed no evident difference in maximal length, fenestration area, scores of shape and margin between the 2 ways of fenestration (P > 0.05). Ankura stent-graft showed the largest holes with best quality than the others. CONCLUSIONS: The primary fenestrations were different between needle and laser puncture, laser induced fabric debris and toxic particles release should be cautiously considered. The final fenestrations were similar after gradual balloon dilation.


Assuntos
Angioplastia com Balão/instrumentação , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Lasers , Agulhas , Desenho de Prótese , Stents , Humanos , Poliésteres/química , Politetrafluoretileno/química
19.
Biomed Res Int ; 2021: 5551207, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34239925

RESUMO

Expanded polytetrafluoroethylene (ePTFE) is commonly used in cardiovascular surgery, but usually causes postoperation complications. Although great efforts have been done to relieve these complications or to understand their mechanism, there are no applicable strategies available and no understanding mechanisms, especially in the myocardium. Here, ePTFE membranes are implanted into the right ventricular outflow tract of rabbits, and the implant-related myocardium is dissected and analyzed by histology and transcriptome sequencing. ePTFE implantation causes myocardium inflammation and fibrosis. There are 1867 differently expressed mRNAs (DEmRNAs, 1107 upregulated and 760 downregulated) and 246 differently expressed lncRNAs (DElncRNAs, 110 upregulated and 136 downregulated) identified. Bioinformatic analysis indicates that the upregulated DEmRNAs and DElncRNAs are mainly involved in inflammatory, immune responses, and extracellular matrix remodeling, while the downregulated DEmRNAs and DElncRNAs are predominantly functioned in the metabolism and cardiac remodeling. Analysis of coexpression and regulatory relationship of DEmRNAs and DElncRNAs reveals that most DElncRNAs are trans-regulated on the relevant DEmRNAs. In conclusion, ePTFE implantation causes severe myocardial tissue damages and alters the transcriptome profiles of the myocardium. Such novel data may provide a landscape of mechanisms underlying the adverse reactions caused by ePTFE implantation and uncover new therapeutic targets for inhibiting the ePTFE-related complications.


Assuntos
Biologia Computacional/métodos , Miocárdio/metabolismo , Politetrafluoretileno/química , Transcriptoma , Animais , Matriz Extracelular/metabolismo , Feminino , Fibrose , Perfilação da Expressão Gênica , Regulação da Expressão Gênica , Redes Reguladoras de Genes , Ventrículos do Coração/patologia , Sistema Imunitário , Inflamação , Miocárdio/patologia , RNA Longo não Codificante/metabolismo , RNA Mensageiro/metabolismo , Coelhos , Análise de Sequência de RNA , Função Ventricular Direita
20.
ACS Appl Mater Interfaces ; 13(28): 33652-33663, 2021 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-34236833

RESUMO

We report the design and characterization of liquid crystal (LC)-infused porous polymer membranes that can detect and report on the presence of natural and synthetic amphiphiles in aqueous solution. We demonstrate that thermotropic LCs can be infused into nanoporous polymer membranes to yield LC-infused surfaces that exhibit slippery behaviors in contact with a range of aqueous fluids. In contrast to conventional liquid-infused surfaces (LIS) or slippery liquid-infused porous surfaces (SLIPS) prepared using isotropic oils, aqueous solutions slide over the surfaces of these LC-infused materials at speeds that depend strongly upon the composition of the fluid, including the presence, concentration, or structure of a dissolved surfactant. In general, the sliding times of aqueous droplets on these LC-infused surfaces increase significantly (e.g., from times on the order of seconds to times on the order of minutes) with increasing amphiphile concentration, allowing sliding times to be used to estimate the concentration of the amphiphile. Additional experiments revealed other intrinsic and extrinsic variables or parameters that can be used to further manipulate droplet sliding times and discriminate among amphiphiles of similar structure. Our results are consistent with a physical picture that involves reversible changes in the interfacial orientation of anisotropic LCs mediated by the interfacial adsorption of amphiphiles. These materials thus permit facile "naked-eye" detection and discrimination of amphiphiles in aqueous samples using equipment no more sophisticated than a stopwatch. We demonstrate the potential utility of these LC-infused surfaces for the unaided, naked-eye detection and monitoring of amphiphilic biotoxins in small droplets of fluid extracted directly from cultures of two common bacterial pathogens (Pseudomonas aeruginosa and Staphylococcus aureus). The ability to translate molecular interactions at aqueous/LC interfaces into large and readily observed changes in the sliding times of small aqueous droplets on surfaces could open the door to new applications for antifouling, liquid-infused materials in the context of environmental sensing and other fundamental and applied areas.


Assuntos
Toxinas Bacterianas/análise , Cristais Líquidos/química , Polímeros/química , Tensoativos/análise , Adsorção , Toxinas Bacterianas/química , Técnicas de Química Analítica/métodos , Politetrafluoretileno/química , Porosidade , Estudo de Prova de Conceito , Pseudomonas aeruginosa/química , Staphylococcus aureus/química , Tensoativos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA