Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.448
Filtrar
1.
BMC Oral Health ; 24(1): 545, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730391

RESUMO

BACKGROUND: This Finite Element Analysis was conducted to analyze the biomechanical behaviors of titanium base abutments and several crown materials with respect to fatigue lifetime and stress distribution in implants and prosthetic components. METHODS: Five distinct designs of implant-supported single crowns were modeled, including a polyetheretherketone (PEEK), polymer-infiltrated ceramic network, monolithic lithium disilicate, and precrystallized and crystallized zirconia-reinforced lithium silicates supported by a titanium base abutment. For the static load, a 100 N oblique load was applied to the buccal incline of the palatal cusp of the maxillary right first premolar. The dynamic load was applied in the same way as in static loading with a frequency of 1 Hz. The principal stresses in the peripheral bone as well as the von Mises stresses and fatigue strength of the implants, abutments, prosthetic screws, and crowns were assessed. RESULTS: All of the models had comparable von Mises stress values from the implants and abutments, as well as comparable maximum and minimum principal stress values from the cortical and trabecular bones. The PEEK crown showed the lowest stress (46.89 MPa) in the cervical region. The prosthetic screws and implants exhibited the highest von Mises stress among the models. The lithium disilicate crown model had approximately 9.5 times more cycles to fatique values for implants and 1.7 times more cycles to fatique values for abutments than for the lowest ones. CONCLUSIONS: With the promise of at least ten years of clinical success and favorable stress distributions in implants and prosthetic components, clinicians can suggest using an implant-supported lithium disilicate crown with a titanium base abutment.


Assuntos
Benzofenonas , Coroas , Dente Suporte , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Análise de Elementos Finitos , Titânio , Titânio/química , Humanos , Porcelana Dentária/química , Polietilenoglicóis/química , Materiais Dentários/química , Polímeros , Cetonas/química , Zircônio/química , Implantes Dentários para Um Único Dente , Teste de Materiais , Projeto do Implante Dentário-Pivô , Fenômenos Biomecânicos
2.
Am J Dent ; 37(2): 85-90, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38704851

RESUMO

PURPOSE: To evaluate clinical performances of two lithium disilicate systems (Initial LiSi press vs Initial LiSi Block, GC Co.) using modified United States Public Health Service (USPHS) evaluation criteria and survival rates after 4 years of clinical service. METHODS: Partial adhesive crowns on natural abutment posterior teeth were made on 60 subjects who were randomly divided into two groups: Group 1: Initial LiSi press and Group 2: Initial LiSi Block. Fabrication of partial crowns was made with full analog and digital procedure in Groups 1 and 2 respectively. The restorations were followed-up for 1 and 4 years, and the modified USPHS evaluation was performed at baseline and each recall together with periodontal evaluation. Contingency tables to assess for significant differences of success over time in each group and time-dependent Cox regression to test for differences between the two groups were used and the level of significance was set at P< 0.05. RESULTS: Regarding modified USPHS scores, all evaluated parameters showed Alpha or Bravo and no Charlie was recorded. No statistically significant difference emerged between the two groups in any of the assessed variables (P> 0.05). No statistically significant difference between scores recorded at the baseline and each recall. All modified USPHS scores were compatible with the outcome of clinical success and no one restoration was replaced or repaired, and the survival rate was 100% after 4 years of clinical service. No difference was found between traditional and digital procedure to fabricate the crowns. The two lithium disilicate materials showed similar results after 4 years of clinical service. CLINICAL SIGNIFICANCE: The crowns made with the two tested lithium disilicate materials with analog and digital procedures showed 100% survival after 4 years of clinical service with no statistically significant difference using the modified USPHS scores.


Assuntos
Coroas , Porcelana Dentária , Humanos , Porcelana Dentária/química , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Seguimentos
3.
Am J Dent ; 37(2): 106-112, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38704854

RESUMO

PURPOSE: To compare the fracture resistance and failure mode of porcelain laminate veneers with different preparation depths in endodontically treated teeth. METHODS: Root canal treatment was performed for 40 maxillary central incisors, and then the teeth were divided into four groups (n= 10). The preparation depths were as follows: Group A: 0.9 mm, Group B: 0.6 mm, Group C: 0.3 mm, and in all three groups, 2 mm butt joint incisal reductions were performed; Group D was a control group with no preparation. Then 30 lithium disilicate porcelain veneers were milled by CAD- CAM method and cemented. After that, all specimens were subjected to cyclic loading and thermal cycling and finally were tested by a universal testing machine until failure occurred. RESULTS: The mean failure loads (N) after exposure to continuous load were as follows: Group A: 625.70 (401.45-1037.77), Group B: 780.32 (222.93-1391.82), Group C: 748.81 (239.68-1241.87) and Group D (control) : 509.88 (84.42-1025.85) and P= 0.216. Analysis of failure mode in four groups showed that P= 0.469. There was no significant difference between the control and the other groups. In this study, 0.3, 0.6 and 0.9 mm depths of preparation for porcelain laminate veneers for endodontically treated teeth had no significant difference in fracture resistance and failure mode with non-prepared teeth. CLINICAL SIGNIFICANCE: Reasonable consideration might be given to porcelain laminate veneer treatment for teeth that have become discolored and resistant to bleaching (such as instances where discoloration is severe following root canal treatment). This approach is considered to be on the conservative side, and has demonstrated that a labial preparation depth reduction of up to 0.9 mm does not have any impact on the failure mode or fracture resistance of endodontically-treated teeth.


Assuntos
Porcelana Dentária , Falha de Restauração Dentária , Análise do Estresse Dentário , Facetas Dentárias , Dente não Vital , Porcelana Dentária/química , Humanos , Incisivo , Teste de Materiais
4.
J Appl Biomater Funct Mater ; 22: 22808000241250118, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38706266

RESUMO

Despite the development of implant-supported prostheses, there are still patients for whom conservative treatments such as resin-bonded fixed dental prostheses (RBFDPs) are more appropriate. This study's objective was to analyze the available research on full-ceramic RBFDPs. In this study, Web of Science, MEDLINE/PubMed, Scopus, Embase, Cochrane Library, and Google Scholar databases were searched for articles published in English between 2010 and 2020. A total of 14 studies were reviewed based on the eligibility criteria. The results showed that using a cantilever design with one abutment had an advantage over two abutments. Additionally, it was proposed that preparations designed with retentive aids, such as a proximal box, groove, and pinhole, could improve RBFDP survival rates. IPS e.max ZirCAD, In-Ceram alumina, and zirconia CAD/CAM were the most commonly used framework materials. Most studies used air abrasion, salinization, or hydrofluoric acid for surface treatment. Adhesive resin cements were the most frequently used type of cement. The survival rate of In-Ceram ceramics (85.3%-94.8%) was lower than that of In-Ceram zirconia and IPS e.max ZirCAD. Debonding, followed by framework fracture, was the leading cause of failure. Following 3-10 years follow-up, the survival percentage of all-ceramic RBFDPs ranged from 76% to 100%. Although RBFDPs have demonstrated satisfactory success as a conservative treatment, long-term follow-ups and higher sample sizes in clinical research are required to gain more reliable outcomes on the clinical success rate of various RBFDP designs.


Assuntos
Cerâmica , Humanos , Cerâmica/química , Cimentos de Resina/química , Porcelana Dentária/química , Prótese Dentária Fixada por Implante , Prótese Adesiva , Zircônio/química
5.
BMC Oral Health ; 24(1): 513, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38698366

RESUMO

BACKGROUND: This study aims to evaluate the effect of surface treatment and resin cement on the shear bond strength (SBS) and mode of failure of polyetheretherketone (PEEK) to lithium disilicate ceramic (LDC). This is suggested to study alternative veneering of PEEK frameworks with a ceramic material. METHODS: eighty discs were prepared from PEEK blank and from lithium disilicate ceramic. Samples were divided into four groups according to surface treatment: Group (A) air abraded with 110 µm Al2O3, Group (AP) air abrasion and primer application, Group (S) 98% sulfuric acid etching for 60 s, Group (SP) Sulfuric acid and primer. Each group was subdivided into two subgroups based on resin cement type used for bonding LDC:1) subgroup (L) self- adhesive resin cement and 2) subgroup (B) conventional resin cement (n = 10). Thermocycling was done for all samples. The bond strength was assessed using the shear bond strength test (SBS). Failure mode analysis was done at 50X magnification with a stereomicroscope. Samples were chosen from each group for scanning electron microscope (SEM). The three-way nested ANOVA followed by Tukey's post hoc test were used for statistical analysis of results. Comparisons of effects were done utilizing one way ANOVA and (p < 0.05). RESULTS: The highest mean of shear bond strength values was demonstrated in Group of air abrasion with primer application using conventional resin cement (APB) (12.21 ± 2.14 MPa). Sulfuric acid groups showed lower shear bond strength values and the majority failed in thermocycling especially when no primer was applied. The failure mode analysis showed that the predominant failure type was adhesive failure between cement and PEEK, while the remaining was mixed failure between cement and PEEK. CONCLUSION: The air abrasion followed by primer application and conventional resin cement used for bonding Lithium Disilicate to PEEK achieved the best bond strength. Primer application did not have an effect when self-adhesive resin cement was used in air-abraded groups. Priming step is mandatory whenever sulfuric acid etching surface treatment is utilized for PEEK.


Assuntos
Benzofenonas , Colagem Dentária , Porcelana Dentária , Análise do Estresse Dentário , Cetonas , Teste de Materiais , Polietilenoglicóis , Polímeros , Cimentos de Resina , Resistência ao Cisalhamento , Propriedades de Superfície , Colagem Dentária/métodos , Condicionamento Ácido do Dente/métodos , Ácidos Sulfúricos , Cerâmica/química , Abrasão Dental por Ar/métodos , Óxido de Alumínio , Facetas Dentárias , Corrosão Dentária/métodos , Humanos
6.
Clin Oral Investig ; 28(5): 298, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702521

RESUMO

OBJECTIVES: To assess the long-term clinical performance of ceramic in-/onlays (CIOs) and cast gold partial crowns (CGPCs) in posterior teeth in terms of success, survival, complications (biological, technical) and quality. MATERIAL AND METHODS: In a retrospective study, a total of 325 patients were recorded after up to 24.8 years (mean 13.9 ± 3.8 years) having (pre-)molars restored with CIO (Empress I, Ivoclar Vivadent, n = 161) and CGPC (Degunorm, DeguDent, n = 164) by supervised undergraduate students. A total of 296 restorations were assessed clinically and radiologically in healthy and endodontically treated teeth using modified United States Public Health Service (USPHS) criteria. Cumulative success and survival rates of the restorations were calculated using Kaplan-Meier estimates. Biological and technical complications were recorded. Status of oral health comprising caries risk and localized periodontitis were assessed. RESULTS: The cumulative success rates of CIOs were 92.1% and of CGPCs 84.2% after mean service times of 14.5 years. The annual failure rates of total service times were 0.5% in teeth restored with CIO (n = 155) and 0.7% in teeth restored with CGPC (n = 163). The cumulative survival rates of CIOs were 93.9% after a mean service time of 15.2 years and decreased to 91.7% after 23.5 years. The cumulative survival rates of CGPCs were 92.6% after a mean service time of 14.9 years and 91.8% after 23.5 years. Complications in CIOs (n = 149) were ceramic fracture (6.7%), secondary caries (4.7%), endodontic complication (2.7%) and tooth fracture (1.3%) compared to CGPCs (n = 147) with endodontic complication (8.8%), secondary caries (4.8%) and decementation (2.0%). Endodontically treated teeth restored with CIO or CGPC revealed significantly less often success compared with corresponding vital teeth (p = .02). CIOs and CGPCs revealed clinically and radiographically good and excellent qualities with 71.8% (107/149) and 68% (100/147) without any significant differences regarding type of restoration. CONCLUSIONS: Both CIOs and CGPCs achieved high survival rates up to 24.8 years when performed by supervised undergraduate students. The longevity of the restorations may benefit from the intraoral repair of accessible defects and, in case of pulp infection or necrosis, an adequate endodontic management. CLINICAL RELEVANCE: CIOs and CGPCs made by supervised undergraduate students are proper restoration types in posterior teeth in the long-term. An adequate preparation design, meticulous care in the inserting technique and constant biofilm removal due to proper oral hygiene combined with professional maintenance care are substantial. The clinical long-term performance was mostly limited by ceramic fractures in CIOs and endodontic complications in CGPCs.


Assuntos
Coroas , Falha de Restauração Dentária , Humanos , Estudos Retrospectivos , Feminino , Masculino , Adulto , Restaurações Intracoronárias , Cerâmica , Ligas de Ouro , Cárie Dentária/terapia , Porcelana Dentária/química , Pessoa de Meia-Idade , Planejamento de Prótese Dentária , Dente não Vital , Resultado do Tratamento
7.
J Dent ; 144: 104987, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38580056

RESUMO

OBJECTIVES: To evaluate whether post-milling firing and material type affect the fabrication trueness and internal fit of lithium disilicate crowns. METHODS: A prefabricated cobalt chromium abutment was digitized to design a mandibular right first molar crown. This design file was used to fabricate crowns from different lithium disilicate ceramics (nano-lithium disilicate (AM), fully crystallized lithium disilicate (IN), advanced lithium disilicate (TS), and lithium disilicate (EX)) (n = 10). Crowns, the abutment, and the crowns when seated on the abutment were digitized by using an intraoral scanner. Fabrication trueness was assessed by using the root mean square method, while the internal fit was evaluated according to the triple scan method. These processes were repeated after the post-milling firing of AM, TS, and EX. Paired samples t-tests were used to analyze the effect of post-milling firing within AM, TS, and EX, while all materials were compared with 1-way analysis of variance and Tukey HSD tests (α = 0.05). RESULTS: Post-milling firing reduced the surface deviations and internal gap of AM and EX (P ≤ 0.014). AM mostly had higher deviations and internal gaps than other materials (P ≤ 0.030). CONCLUSIONS: Post-milling firing increased the trueness and internal fit of tested nano-lithium disilicate and lithium disilicate ceramics. Nano-lithium disilicate mostly had lower trueness and higher internal gap; however, the maximum meaningful differences among tested materials were small. Therefore, the adjustment duration and clinical fit of tested crowns may be similar. CLINICAL SIGNIFICANCE: Tested lithium disilicate ceramics may be suitable alternatives to one another in terms of fabrication trueness and internal fit, considering the small differences in measured deviations and internal gaps.


Assuntos
Desenho Assistido por Computador , Coroas , Porcelana Dentária , Planejamento de Prótese Dentária , Teste de Materiais , Porcelana Dentária/química , Humanos , Dente Suporte , Cerâmica/química , Propriedades de Superfície , Materiais Dentários/química , Adaptação Marginal Dentária , Ligas de Cromo/química
8.
Gen Dent ; 72(3): 42-48, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38640005

RESUMO

The present article reviews the literature regarding tetracycline staining of the dentition and its esthetic management. A total of 49 articles were identified in the initial search, and 22 articles met the eligibility criteria of this narrative literature review. Tetracycline staining results from its use in children between the ages of 6 months and 6 years, when tooth crowns are formed; the effects are dependent on the dosage, duration of treatment, stage of tooth mineralization, and activity of the mineralization process. Tooth bleaching is always the first treatment option for low-grade cases of tetracycline staining. Restorative procedures are indicated for severe staining. The article also describes the treatment of severe staining affecting the maxillary anterior dentition of a 48-year-old man who reported the systemic administration of tetracycline during childhood. Direct composite resin laminate veneers were proposed to achieve immediate, highly esthetic restorations. A combination of different resinous materials in different shades was applied to meet the needs of the patient. The use of direct composite resin laminate veneers satisfied the functional and esthetic demands of the patient at a lower cost than ceramic materials.


Assuntos
Porcelana Dentária , Dentição , Humanos , Masculino , Pessoa de Meia-Idade , Antibacterianos , Resinas Compostas , Facetas Dentárias , Tetraciclina/efeitos adversos
9.
Eur J Oral Sci ; 132(3): e12989, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38679835

RESUMO

This study aimed at examining the bond strength between zirconia and ceramic veneer, following the ISO 9693 guidelines. A total of fifty specimens of zirconia/ceramic-veneer system were produced using two commercial zirconias (VITA YZ-HTWhite and Zolid HT+ White, referred to as Group A and Group B, respectively) and a ceramic-veneering material (Zirkonia 750). The microstructure (via x-ray diffraction analysis, XRD and Secondary Electron mode, SEM) and the mechanical properties (via 3-point bending tests) of the two groups were assessed. Then, experiments were conducted according to the ISO 9693 and conventional protocols applied for producing zirconia/ceramic-veneer restorations. Bond strength values, measured by 3-point bending tests, were 34.42 ± 7.60 MPa for Group A and 31.92 ± 6.95 MPa for Group B. SEM observations of the cohesively fractured surfaces (on the porcelain side) and the examination for normality using the Shapiro-Wilk test suggested the use of Weibull statistical analysis. Median strength (σ50%) for Group A and Group B was 34.76 and 32.22 MPa, while the characteristic strength (σ63.2%) was 35.78 and 33.14 MPa, respectively. The Weibull modulus disparity between groups (12.69 and 13.07) was not significant. Bond strength exceeded the ISO 9693 minimum of 20 MPa, suggesting satisfactory strength for clinical use.


Assuntos
Colagem Dentária , Porcelana Dentária , Análise do Estresse Dentário , Facetas Dentárias , Teste de Materiais , Microscopia Eletrônica de Varredura , Difração de Raios X , Zircônio , Zircônio/química , Porcelana Dentária/química , Propriedades de Superfície , Cerâmica/química , Materiais Dentários/química , Humanos
10.
J Indian Prosthodont Soc ; 24(2): 144-151, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38650339

RESUMO

AIM: The main aim of the present study was to compare and evaluate the effect of repetitive firings on different shades of a pressable all ceramic system layered with veneering porcelain. SETTING AND DESIGN: In-vitro comparative study. MATERIALS AND METHODS: An in vitro comparative study was conducted, and a total of 60 disc shaped specimens (15 mm in diameter and 0.8 mm in thickness) were made of heat pressed ceramic of shades A2, A3, and B2 (20 discs of each shade) grouped as Group I, II, and III, respectively, using the lost wax technique. The discs were subsequently layered with veneering porcelain followed by glazing and overglazing and underwent a firing cycle at each step until six times combined. CIE L*a*b* measurements were noted on each sample after the third, fourth, fifth, and sixth firing using VITA Easyshade Advance 4.0 spectrophotometer. STATISTICAL ANALYSIS USED: Statistical Analysis was done by SPSS 17.0 software. One way analysis of variance, multiple comparisons using the Tukey test, and descriptive statistical analysis were done for all the groups in the study. P <0.05 was statistically significant. RESULTS: The mean color differences for the repeated firings were imperceptible (ΔE <1.67) to the human eye for all ceramic samples tested except between the fourth and fifth firing of Group II (shade A3). CONCLUSION: The analysis revealed that although repeated firings lead to changes in L*, a*, and b* values, the mean color difference was below the clinically acceptable color change (ΔE <3.7).


Assuntos
Cerâmica , Cerâmica/química , Porcelana Dentária/química , Cor , Facetas Dentárias , Teste de Materiais/métodos , Humanos , Pigmentação em Prótese/métodos , Temperatura Alta , Técnicas In Vitro , Espectrofotometria/métodos
12.
PLoS One ; 19(4): e0301799, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38625846

RESUMO

BACKGROUND: Marginal fit significantly impacts the long-term success of dental restorations. Different pattern fabrication methods, including hand-waxing, milling, or 3D printing, may affect restorations accuracy. The effect of porcelain firing cycles on the marginal fit of metal-ceramic restorations remains controversial, with conflicting findings across studies. PURPOSE: The aim was to evaluate the potential effects of multiple porcelain firings (3, 5, 7 cycles) as well as pattern fabrication method (conventional hand-waxing, milling, and 3D printing) on the marginal adaptation of 3-unit implant-supported metal-ceramic fixed partial dentures. It was hypothesized that neither the wax pattern fabrication method nor repeated ceramic firings would significantly affect the marginal adaptation of metal-ceramic crowns. METHODS: In this in-vitro study, 30 Cobalt-Chromium alloy frameworks were fabricated based on pattern made through three techniques: conventional hand-waxing, CAD-CAM milling, and CAD-CAM 3D printing (n = 10 per group). Sixteen locations were marked on each abutment to measure the vertical marginal gap at four stages: before porcelain veneering and after 3, 5, and 7 firing cycles. The vertical marginal gap was measured using direct microscopic technique at ×80 magnification. Mean vertical marginal gap values were calculated and two-way ANOVA and Tukey's post hoc tests were used for inter-group comparisons (α = 0.05). RESULTS: The 3D printing group showed significantly lower (P<0.001) mean vertical marginal gaps (60-76 µm) compared to the milling (77-115 µm) and conventional hand-waxing (102-110 µm) groups. The milling group exhibited a significant vertical gap increase after 3 firing cycles (P<0.001); while the conventional (P = 0.429) and 3D printing groups (P = 0.501) showed no significant changes after 7 firing cycles. Notably, the vertical marginal gap in all groups remained below the clinically acceptable threshold of 120 µm. CONCLUSION: CAD-CAM 3D printing provided superior marginal fit compared to CAD-CAM milling and conventional hand-wax pattern fabrication methods. The impact of porcelain firing on the mean marginal gap was significant only in the milling group. All three fabrication techniques yielded clinically acceptable vertical marginal adaptation after repeated firings. Additive manufacturing holds promise to produce precise implant-supported prostheses.


Assuntos
Desenho Assistido por Computador , Porcelana Dentária , Impressão Tridimensional , Prótese Parcial Fixa , Ligas Metalo-Cerâmicas , Planejamento de Prótese Dentária , Coroas
13.
PLoS One ; 19(4): e0301361, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38625957

RESUMO

OBJECTIVES: The impression technique highly influences the adaptation of ceramic restorations. Not enough information is available to compare the marginal (MF) and internal fit (IF) of endocrowns fabricated with various digitization techniques. Therefore, this in-vitro study aimed to compare the MF and IF of lithium disilicate (LDS) endocrowns fabricated through direct and indirect digital scanning methods. MATERIALS AND METHODS: One extracted maxillary molar was used to fabricate endocrowns. The digitization of the model was performed with (G1) direct scanning (n = 10) utilizing an intraoral scanner (IOS), (G2) indirectly scanning the conventional impression taken from the model using the same IOS (n = 10), (G3) indirectly digitalizing the obtained impression using an extraoral scanner (EOS) (n = 10), and (G4) scanning the poured cast using the same EOS (n = 10). The MF and IF of the endocrowns were measured using the replica method and a digital stereomicroscope. The Kruskal-Wallis test was used to analyze data. RESULTS: The studied groups differed significantly (p<0.001). G2 (130.31±7.87 µm) and G3 (48.43±19.14 µm) showed the largest and smallest mean vertical marginal gap, respectively. G2 and G3 led to the highest and lowest internal gaps in all regions, respectively. With significant differences among the internal regions (p<0.001), the pulpal area demonstrated the most considerable misfit in all groups. CONCLUSIONS: Scanning the impression using an extraoral scanner showed smaller marginal and internal gaps.


Assuntos
Desenho Assistido por Computador , Porcelana Dentária , Cerâmica , Dente Molar , Planejamento de Prótese Dentária , Técnica de Moldagem Odontológica
14.
PeerJ ; 12: e17236, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38618572

RESUMO

Purpose: Juniper (Juniperus procera) is a common forest tree species in Saudi Arabia. The decline in many populations of J. procera in Saudi Arabia is mainly due to seed dormancy and loss of natural regeneration. This study assessed the effects of chemical and hormonal treatments on seed germination and seedling growth in juniper plants. Methods: The seeds were subjected to either chemical scarification with 90% sulfuric acid and 20% acetic acid for 6 min or hormonal treatment by seed soaking in two concentrations (50 and 100 ppm) of three growth regulators, namely, indole acetic acid (IAA), gibberellins (GA3), and kinetin, for 72 h. A control group without any seed treatment was also prepared. The experiments were performed in an incubator maintained at room temperature and under a light and dark period of 12 h for 6 w. The germinated seeds for each treatment were counted and removed from the dishes. The selected germinated seeds from different treatments were planted in a greenhouse and irrigated with tap water for another 6 weeks. The hormone-treated seedlings were sprayed with their corresponding hormone concentrations 1 w after planting. Results: The highest percentage of seed germination was significantly recorded after seed soaking in 50 ppm GA3, whereas treatment with IAA (100 ppm) resulted in the best seedling growth. Seedlings treated with the three phytohormones showed a significant increase in photosynthetic pigments, total soluble sugars, proteins, percentage of oil, IAA, GA3, and kinetin contents of juniper seedlings compared with the control value, whereas abscisic acid content was decreased compared with chemical treatments. Conclusion: The investigated different treatments had an effective role in breaking seed dormancy and improving seedling growth of J. procera, which is facing a notable decline in its population worldwide. Moreover, such an effect was more pronounced in the three phytohormones that succeeded in breaking dormancy and growth of the Juniperus plant than in the other treatments.


Assuntos
Porcelana Dentária , Juniperus , Ligas Metalo-Cerâmicas , Plântula , Titânio , Germinação , Reguladores de Crescimento de Plantas/farmacologia , Cinetina/farmacologia , Sementes , Hormônios
15.
Int J Prosthodont ; 37(2): 135-144, 2024 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-38648162

RESUMO

PURPOSE: To study the degree of accuracy in gingival shade matching of undergraduate students using a computer application. MATERIALS AND METHODS: In total, 76 undergraduate dental students' gingival shade selection abilities were evaluated using an in-house developed computer application. A total of 15 intraoral gingival photographs and 21 pink gingival color porcelain samples were used. The environmental conditions were standardized, and no time limit was set for answering in the computer application. RESULTS: Fourteen gingival color samples (66.6%) were not useful for representing the studied gingival shades. Not all natural gingival colors studied were represented within the 50.50% acceptability limits of the pink samples. There were no statistically significant differences between men and women in terms of "hit" percentages. The highest correlation coefficient (in absolute value) was for the L* coordinate (the darker the gingiva in the picture, the higher the hit rate for choosing the "ideal" shade tab); however, none of the linear correlation coefficients were statistically significant. CONCLUSIONS: Not all colors provided in the pink ceramic system were useful for subjective gingival selection. There were no statistically significant differences between male and female dental students in gingival color perception. The L* coordinate was the only one that influenced the correct perception of gingival color by dental students, and it did so more in women than in men.


Assuntos
Gengiva , Pigmentação em Prótese , Estudantes de Odontologia , Humanos , Feminino , Masculino , Gengiva/anatomia & histologia , Gengiva/diagnóstico por imagem , Cor , Porcelana Dentária , Adulto Jovem , Adulto , Fotografia Dentária
16.
J Prosthet Dent ; 131(5): 935.e1-935.e8, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38431509

RESUMO

STATEMENT OF PROBLEM: Computer-aided design and computer-aided manufacturing (CAD-CAM) materials have become popular for dental restorations; however, which materials should be preferred in terms of surface properties after biofilm formation is unclear. PURPOSE: The purpose of this in vitro study was to investigate the effect of biofilm formation on the discoloration properties of resin-infiltrated ceramic and glass-ceramic CAD-CAM materials and human teeth and to examine the effect of the brushing procedure on color change. MATERIAL AND METHODS: One hundred and six 2-mm-thick specimens were prepared from IPS e.max CAD and Cerasmart, and a total of 53 intact human teeth were used. Five specimens from each group were used to measure the amount of live biomass in the biofilm. The remaining 48 specimens in each group were divided into 4 subgroups: kept in distilled water without the formation of dental biofilm (DW), kept in tea without the formation of dental biofilm (T), kept in distilled water after the formation of dental biofilm (DWB), and kept in tea after the formation of dental biofilm (TB) (n=12). After finishing and polishing the materials, initial color measurements were made using a spectrophotometer, and surface roughness measurements were made using noncontact profilometer. After creating a biofilm layer in DWB and TB, all specimens were kept in their solutions at 37 °C for 24 hours, and the color measurements were repeated. After the biofilm layer had been removed by brushing, a third color measurement was made. The data were statistically analyzed with one-way analysis of variance (ANOVA) and two-way ANOVA (α=.05). RESULTS: The lowest roughness value was observed in Cerasmart. Tooth-IPS e.max CAD gave similar results. The Cerasmart material had the most viable biomass, whereas the IPS e.max CAD material had the least. TB had the highest ΔE1 value for all materials and DW had the lowest (P<.05). The brushing procedure caused the materials to return to their initial colors or reduce the color change in most groups. CONCLUSIONS: The presence of biofilm on CAD-CAM materials immersed in distilled water caused an unacceptable degree of discoloration (ΔE>1.8), and immersion in tea led to greater color change. The adhesion of biofilm to restorative dental materials plays an important role in the coloring of these dental materials.


Assuntos
Biofilmes , Cerâmica , Cor , Desenho Assistido por Computador , Porcelana Dentária , Propriedades de Superfície , Cerâmica/química , Humanos , Teste de Materiais , Técnicas In Vitro , Materiais Dentários/química , Escovação Dentária , Resinas Sintéticas
17.
J Prosthet Dent ; 131(5): 916.e1-916.e9, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38443240

RESUMO

STATEMENT OF PROBLEM: Dental implants are particularly susceptible to occlusal overloading because, unlike natural teeth, they lack a periodontal ligament to help absorb occlusal forces. However, studies evaluating the impact of different crown and luting materials on the damping behavior and strain distribution of implant-supported crowns are lacking. PURPOSE: The purpose of this in vitro study was to investigate the damping behavior and strain distribution of peri-implant bone associated with 5 different CAD-CAM implant-supported crowns and 3 luting materials. MATERIAL AND METHODS: A titanium implant was embedded in a plastic tube with epoxy resin and 5 different crown materials (polymethyl methacrylate, resin-infiltrated ceramic, lithium disilicate, titanium, and zirconia) luted to prosthetic abutments with 3 different luting materials (zinc oxide non-eugenol cement, zinc phosphate cement, and adhesive resin cement) and an uncemented condition were tested (n=5). Strain gauges were attached at the crestal and apical levels of the implant model. All specimens were load tested from 0 to 200 N. Slopes of load/time, microstrain/time, and time required to reach the maximum load were examined to represent the damping behavior. Absolute maximum strain (AMS) and its occurrence level were examined to represent the strain distribution. Two-way ANOVA, followed by the Tukey HSD test, were used for statistical analysis (α=.05). RESULTS: All slopes and times to reach the maximum load in each crown material were statistically similar (P>.05), except for the polymethyl methacrylate group, which showed less steepness in all slopes and more time required to reach the maximum load significantly (P<.05). Both the polymethyl methacrylate group (224.5 ±30.2) and the titanium group (224.0 ±24.3) exhibited significantly higher AMS at the crestal level compared with the resin-infiltrated ceramic group (210.6 ±5.0) (P<.05). The lithium disilicate (218.1 ±15.0) and zirconia groups (217.3 ±14.8) demonstrated comparable AMS values with the others (P>.05). The uncemented group demonstrated steeper slopes and less time required to reach the maximum load compared with the adhesive resin group (P<.05), while slopes and times of the zinc phosphate and zinc oxide non-eugenol groups were comparable (P>.05). The uncemented group (242.7 ±25.3) exhibited significantly higher AMS at the crestal level than the other groups (P<.05). CONCLUSIONS: The crown material significantly affected the damping behavior of peri-implant bone, unlike the luting material. Polymethyl methacrylate with a high damping behavior exhibited high strain at the crestal level. In contrast, resin-modified ceramic with a moderate damping behavior exhibited low strain at the crestal level. Strain at the crestal level could be effectively reduced by approximately 13% through cementation.


Assuntos
Desenho Assistido por Computador , Coroas , Cimentos Dentários , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Cimentos Dentários/química , Cimentos Dentários/uso terapêutico , Humanos , Técnicas In Vitro , Polimetil Metacrilato/química , Cimentos de Resina/química , Teste de Materiais , Cimento de Fosfato de Zinco/química , Titânio/química , Zircônio/química , Porcelana Dentária/química , Cerâmica/química
18.
J Dent ; 144: 104941, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38490323

RESUMO

OBJECTIVES: To evaluate how restoration thickness (0.5 mm and 0.7 mm) affects the fabrication trueness of additively manufactured definitive resin-based laminate veneers, and to analyze the effect of restoration thickness and margin location on margin quality. METHODS: Two maxillary central incisors were prepared either for a 0.5 mm- or 0.7 mm-thick laminate veneer. After acquiring the partial-arch scans of each preparation, laminate veneers were designed and stored as reference data. By using these reference data, a total of 30 resin-based laminate veneers were additively manufactured (n = 15 per thickness). All veneers were digitized and stored as test data. The reference and test data were superimposed to calculate the root mean square values at overall, external, intaglio, and marginal surfaces. The margin quality at labial, incisal, mesial, and distal surfaces was evaluated. Fabrication trueness at each surface was analyzed with independent t-tests, while 2-way analysis of variance was used to analyze the effect of thickness and margin location on margin quality (α = 0.05). RESULTS: Regardless of the evaluated surface, 0.7 mm-thick veneers had lower deviations (P < 0.001). Only the margin location (P < 0.001) affected the margin quality as labial margins had the lowest quality (P < 0.001). CONCLUSION: Restoration thickness affected the fabrication trueness of resin-based laminate veneers as 0.7 mm-thick veneers had significantly higher trueness. However, restoration thickness did not affect the margin quality and labial margins had the lowest quality. CLINICAL SIGNIFICANCE: Laminate veneers fabricated by using tested urethane-based acrylic resin may require less adjustment when fabricated in 0.7 mm thickness. However, marginal integrity issues may be encountered at the labial surface.


Assuntos
Resinas Compostas , Adaptação Marginal Dentária , Materiais Dentários , Facetas Dentárias , Incisivo , Propriedades de Superfície , Humanos , Materiais Dentários/química , Resinas Compostas/química , Teste de Materiais , Planejamento de Prótese Dentária , Porcelana Dentária/química , Desenho Assistido por Computador , Cerâmica/química , Poliuretanos/química , Metacrilatos/química
19.
J Contemp Dent Pract ; 25(1): 29-34, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38514428

RESUMO

AIM: To evaluate the effect of thermo-mechanical cycling (TMC) on fracture resistance of different computer-aided design/computer-aided manufacture (CAD/CAM) crowns. MATERIALS AND METHODS: A total of 42 CAD/CAM crowns were fabricated on epoxy resin maxillary first premolar teeth and divided into three groups (n = 14) according to the material used: IPS e.max CAD (Ivoclar Vivadent) lithium disilicate (LD), Vita ENAMIC (VE) (VITA Zahnfabrik), Tetric CAD (Ivoclar Vivadent). Also, each group was subdivided into two equal subgroups according to TMC (n = 7). Subgroups (O) without TMC and subgroup (W) with TMC (5-55°C, 30 second, 75,000 cycles). All samples in each group were cemented with a universal bond (Tetric N bond universal) and adhesive resin cement (Variolink Esthetic DC) (Ivoclar Vivadent). Subsequently, the samples were loaded to failure in a universal testing machine at a crosshead speed of 1 mm/min, and the fracture pattern and the fracture resistance in each group were recorded. RESULTS: Fracture resistance was analyzed by one-way analysis of variance (ANOVA) test, followed by Tukey's post hoc test for pairwise comparison. Fracture resistance showed a significant difference between the tested groups before and after TMC; IPS e.max CAD has the highest value (1233.35 ± 97.72, 1165.73 ± 199.54 N) followed by Tetric CAD (927.62 ± 42.5, 992.04 ± 53.46 N) and Vita ENAMIC has lowest value (506.49 ± 74.24, 354.69 ± 90.36 N). CONCLUSION: Thermo-mechanical cycling affected the fracture resistance of both polymer-based CAD/CAM crowns. CLINICAL SIGNIFICANCE: For dental practitioners, both IPS e.max CAD and Tetric CAD can be used clinically for posterior teeth, providing satisfactory results and resistance to fracture. How to cite this article: Elmokadem MI, Haggag KM, Mohamed HR. Effect of Thermo-mechanical Cycling on Fracture Resistance of Different CAD/CAM Crowns: An In Vitro Study. J Contemp Dent Pract 2024;25(1):29-34.


Assuntos
Resinas Acrílicas , Resinas Compostas , Odontólogos , Poliuretanos , Papel Profissional , Humanos , Estética Dentária , Porcelana Dentária , Cerâmica/química , Coroas , Desenho Assistido por Computador , Teste de Materiais , Análise do Estresse Dentário , Falha de Restauração Dentária
20.
J Contemp Dent Pract ; 25(1): 79-84, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38514436

RESUMO

AIM: This study aimed to investigate the effect of modified framework (MF) design on the fracture resistance of IPS e.max Press anterior single crown after thermocycling and cyclic loading. MATERIALS AND METHODS: Two types of IPS e.max Press frameworks were designed (n = 10); standard framework (SF) with a 0.5 mm uniform thickness and MF with a lingual margin of 1 mm in thickness and 2 mm in height connected to a proximal strut of 4 mm height and a 0.3 mm wide facial collar. The crowns were cemented to resin dies, subjected to 5,000 cycles of thermocycling, and loaded 10,000 cycles at 100 N. A universal testing machine was used to load specimens to fracture, and the modes of failure were determined. RESULTS: The mean and standard deviation (SD) of fracture resistance were 219.24 ± 110.00 N and 216.54 ±120.02 N in the SF and MF groups. Thus, there was no significant difference (p = 0.96). Mixed fracture was the most common failure mode in both groups. We found no statistically significant difference between the groups (p = 0.58). CONCLUSION: The MF design did not increase the fracture resistance of IPS e.max Press crown. CLINICAL SIGNIFICANCE: Framework design is an essential factor for the success of all-ceramic restorations and its modification might be regarded as an approach to increase fracture resistance. Furthermore, the modified design was evaluated in metal-ceramic or zirconia crowns while less attention was paid to the IPS e.max Press crowns. How to cite this article: Golrezaei M, Mahgoli HA, Yaghoobi N, et al. The Effect of Modified Framework Design on the Fracture Resistance of IPS e.max Press Crown after Thermocycling and Cyclic Loading. J Contemp Dent Pract 2024;25(1):79-84.


Assuntos
Porcelana Dentária , Falha de Restauração Dentária , Coroas , Cerâmica , Teste de Materiais , Análise do Estresse Dentário , Desenho Assistido por Computador , Planejamento de Prótese Dentária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA