Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.165
Filtrar
1.
Jt Dis Relat Surg ; 35(2): 299-304, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38727108

RESUMO

OBJECTIVES: This study aimed to investigate whether adding tissue samples directly into thioglycolate (TG) broth yielded a greater number of anaerobic organisms than freshly sampled tissue in suspected hip and knee prosthetic joint infections (PJIs). PATIENTS AND METHODS: Between January 2017 and December 2020, a total of 90 patients (46 males, 44 females; median age: 71.7 years; range, 50.8 and 87.8 years) who underwent revision hip or knee arthroplasty were included. Intraoperative samples were taken, with five placed in TG broth and five in standard containers (PC) with subsequent aerobic and anaerobic culturing conducted. Demographic and baseline data of the patients were recorded. The primary outcome was positive bacterial growth from a PJI specimen inoculated directly into TG broth at the time of collection or standard PJI specimen processing. Secondary outcomes investigated were the presence of Cutibacterium acnes (C. acnes) and the curative success of revision procedure. RESULTS: A total of 900 samples (450 PC and 450 TG) were taken from 90 revision arthroplasty patients (47 knees and 43 hips). There was no statistically significant difference in the number of positive bacterial growth samples between TG broth and standard processing (p=0.742). This was consistent with subgroup analysis analyzing C. acnes (p=0.666). CONCLUSION: In hip and knee arthroplasty, there is no benefit in substituting or adding TG broth as a culture medium to better identify both general bacterial species and C. acnes infections specifically. However, the use of TG may be useful in confirming a true positive result for infection.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Infecções Relacionadas à Prótese , Tioglicolatos , Humanos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/tratamento farmacológico , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Artroplastia do Joelho/efeitos adversos , Artroplastia de Quadril/efeitos adversos , Tioglicolatos/farmacologia , Prótese do Joelho/efeitos adversos , Prótese do Joelho/microbiologia , Meios de Cultura/química , Meios de Cultura/farmacologia , Reoperação , Prótese de Quadril/efeitos adversos , Prótese de Quadril/microbiologia , Manejo de Espécimes/métodos , Estudos Retrospectivos
3.
Arch Orthop Trauma Surg ; 144(5): 2421-2428, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38609679

RESUMO

BACKGROUND: Femoral stem fracture following total hip arthroplasty (THA) is an infrequent but nevertheless devastating complication, with an increasing worldwide prevalence as demand for primary THA continues to increase. The aim of this study was to perform a systematic review and meta-analysis of risk factors for femoral stem fracture to help identify at risk patients. METHODS: A systematic search was conducted on EMBASE, MEDLINE and AMED to identify relevant studies. Data regarding study design, source, population, intervention, and outcomes was collated. Data extraction was performed on a custom form generated using Cochrane recommended methodology and analysis of risk factors performed including odds ratios (ORs) with 95% confidence intervals (CIs). RESULTS: A total of 15 studies reporting a total of 402 stem fractures in 49 723 THAs were identified. The median time from index procedure to stem fracture was 68 months (IQR 42.5-118) whilst mean age at index surgery was 61.8 years (SD 6.9). Male gender (OR = 3.27, 95% CI = 2.59-4.13, p < 0.001), patient weight above 80 kg (OR = 3.55, 95% CI = 2.88-4.37, p < 0.001), age under 63 years (OR = 1.22, 95% CI = 1.01-1.49, p < 0.001), varus stem alignment (OR = 5.77, 95% CI = 3.83-8.7, p < 0.001), use of modular implants (OR = 1.95, 95% CI = 1.56-2.44, p < 0.01) and undergoing revision arthroplasty (OR = 3.33, 95% CI = 2.70-4.1, p < 0.001) were significant risk factors for prosthetic stem fracture. A risk window of 15 years post-surgery was identified. CONCLUSIONS: This review concludes that patient weight, younger age, male sex, varus stem alignment, revision arthroplasty and use of modular stems are significant risk factors for femoral stem fracture. Modifying these risk factors where possible may help reduce incidence of femoral stem fracture in at risk patients.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Humanos , Artroplastia de Quadril/efeitos adversos , Fatores de Risco , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/epidemiologia , Fraturas do Fêmur/etiologia , Masculino , Falha de Prótese , Feminino , Prótese de Quadril/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Pessoa de Meia-Idade
4.
Eur J Orthop Surg Traumatol ; 34(4): 2155-2162, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38565783

RESUMO

INTRODUCTION: Increasing interest in the use of anatomical stems has developed as the prevalence of periprosthetic fractures (PPFs) continues to increase. The primary aim of this study was to determine the long-term survivorship and PPF rate of an anatomical femoral stem in a single UK centre. PATIENTS AND METHODS: Between 2000 and 2002, 94 consecutive THAs were performed using the 170 mm Lubinus SP II anatomical femoral stem in our institution. Patient demographics, operative details and clinical outcomes were collected prospectively in an arthroplasty database. Patient records and national radiographic archives were reviewed finally at a mean of 21.5 years (SD 0.7) following surgery to identify occurrence of subsequent revision surgery, dislocation or periprosthetic fracture. RESULTS: Mean patient age at surgery was 65.8 years (SD 12.5, 34-88 years). There were 48 women (51%). Osteoarthritis was the operative indication in 88 patients (94%). Analysis of all-cause THA failure demonstrated a survivorship of 98.5% (95% confidence interval [CI], 98.0-99.3%) at 10 years and 96.7% (94.5-98.9%) at 21 years. The 20-year stem survival for aseptic loosening was 100% with no cases of significant lysis found (lucent line > 2 mm) and no stems required revision. Patient demographics did not appear to influence risk of revision (p > 0.05). There were 2 revisions in total (2 for acetabular loosening with original stems retained). There were no PPFs identified at mean 21.5 year follow-up and 5 dislocations (5%). CONCLUSIONS: The Lubinus SP II 170 mm stem demonstrated excellent survivorship and negligible PPF rates over 20 years following primary THA.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fraturas Periprotéticas , Falha de Prótese , Reoperação , Humanos , Idoso , Feminino , Masculino , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Reoperação/estatística & dados numéricos , Adulto , Seguimentos , Reino Unido , Desenho de Prótese , Fêmur/cirurgia , Fêmur/diagnóstico por imagem , Osteoartrite do Quadril/cirurgia
5.
Medicina (Kaunas) ; 60(4)2024 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-38674229

RESUMO

Periprosthetic joint infection is a feared complication after the megaprosthetic reconstruction of oncologic and non-oncologic bone defects of including the knee or hip joint. Due to the relative rarity of these procedures, however, optimal management is debatable. Considering the expanding use of megaprostheses in revision arthroplasty and the high revision burden in orthopedic oncology, the risk of PJI is likely to increase over the coming years. In this non-systematic review article, we present and discuss current management options and the associated results focusing on studies from the last 15 years and studies from dedicated centers or study groups. The indication, surgical details and results in controlling infection are presented for debridement, antibiotics, irrigation and retention (DAIR) procedure with an exchange of the modular components, single-stage implant exchange, two-stage exchanges and ablative procedures.


Assuntos
Desbridamento , Infecções Relacionadas à Prótese , Humanos , Infecções Relacionadas à Prótese/cirurgia , Desbridamento/métodos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Antibacterianos/uso terapêutico , Antibacterianos/administração & dosagem , Reoperação/métodos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Prótese do Joelho/efeitos adversos , Prótese de Quadril/efeitos adversos , Irrigação Terapêutica/métodos
6.
Acta Orthop ; 95: 174-179, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38629902

RESUMO

BACKGROUND AND PURPOSE: Concerns have emerged regarding elevated levels of cobalt and chromium in patients with metal-on-metal megaprostheses. This prospective study aims to identify systemic cobalt and chromium levels in metal-on-polyethylene knee and hip megaprostheses and their associations with other factors. METHODS: 56 patients underwent knee or hip megaprosthesis surgery at 2 sarcoma centers. Serum cobalt and chromium levels were measured preoperatively and thrice within the first year using inductively coupled plasma mass spectrometry. RESULTS: A statistically significant difference in serum cobalt levels (1.4 ppb; 95% confidence interval [CI] 0.0-3.3) was observed 1 year after knee megaprosthesis surgery compared with preoperative levels. In contrast no difference in chromium levels was observed after 1 year compared with preoperative levels (0.05 ppb; CI 0.0-0.8). An association between younger age, higher eGFR, and increased cobalt levels was observed. No significant correlations were found between ion levels and resection length or the number of modular connections. CONCLUSION: We found elevated serum ion levels in metal-on-polyethylene knee megaprostheses in contrast to metal-on-polyethylene hip megaprostheses. Furthermore, a positive correlation between cobalt and chromium levels, and between cobalt and eGFR was identified, along with a negative correlation between cobalt and age. This study highlights the importance of monitoring systemic cobalt and chromium levels in patients with megaprostheses.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Cobalto , Estudos Prospectivos , Polietileno , Estudos de Coortes , Prótese de Quadril/efeitos adversos , Metais , Cromo , Artroplastia de Quadril/métodos , Desenho de Prótese
7.
PLoS One ; 19(4): e0300956, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38630711

RESUMO

Increasing the stem size during surgery is associated with a higher incidence of intraoperative periprosthetic fractures in cementless total hip arthroplasty with fully coated tapered wedge stems, especially in femurs of Dorr type A. If in contrast a stem is implanted and sufficient primary stability is not achieved, such preventing successful osseointegration due to increased micromotions, it may also fail, especially if the stem is undersized. Stem loosening or periprosthetic fractures due to stem subsidence can be the consequence. The adaptation of an established stem design to femurs of Dorr type A by design modifications, which increase the stem width proximally combined with a smaller stem tip and an overall shorter stem, might reduce the risk of distal locking of a proximally inadequately fixed stem and provide increased stability. The aim of this study was to investigate whether such a modified stem design provides improved primary stability without increasing the periprosthetic fracture risk compared to the established stem design. The established (Corail, DePuy Synthes, Warsaw, IN, US) and modified stem designs (Emphasys, DePuy Synthes, Warsaw, IN, US) were implanted in cadaveric femur pairs (n = 6 pairs) using the respective instruments. Broaching and implantation forces were recorded and the contact areas between the prepared cavity and the stem determined. Implanted stems were subjected to two different cyclic loading conditions according to ISO 7206-4 using a material testing machine (1 Hz, 600 cycles @ 80 to 800 N, 600 cycles @ 80 to 1600 N). Translational and rotational relative motions between stem and femur were recorded using digital image correlation. Broaching and implantation forces for the modified stem were up to 40% higher (p = 0.024), achieving a 23% larger contact area between stem and bone (R2 = 0.694, p = 0.039) resulting in a four times lower subsidence during loading (p = 0.028). The slight design modifications showed the desired effect in this in-vitro study resulting in a higher primary stability suggesting a reduced risk of loosening. The higher forces required during the preparation of the cavity with the new broaches and during implantation of the stem could bare an increased risk for intraoperative periprosthetic fractures, which did not occur in this study.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Prótese de Quadril/efeitos adversos , Fraturas Periprotéticas/epidemiologia , Desenho de Prótese , Artroplastia de Quadril/efeitos adversos , Osseointegração , Fêmur/cirurgia , Reoperação/efeitos adversos , Estudos Retrospectivos
8.
Acta Orthop Belg ; 90(1): 135-138, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38669663

RESUMO

This case report describes a single patient with recurrent implant fractures of his left total hip replacement. According to our knowledge this is the first patient in literature with recurrent implant fractures. This is a rare phenomenon as reason for revision. Risk factors for implant failure of total hip replacement include a lack of proximal support, a distally well fixed stem with proximal debonding, malalignment of the stem and raised BMI.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Falha de Prótese , Recidiva , Reoperação , Humanos , Artroplastia de Quadril/métodos , Artroplastia de Quadril/efeitos adversos , Masculino , Prótese de Quadril/efeitos adversos , Fraturas Periprotéticas/cirurgia , Fraturas Periprotéticas/etiologia , Idoso
9.
Acta Orthop Belg ; 90(1): 139-141, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38669664

RESUMO

Liner dissociations are rare but catastrophic complications after THA, requiring revision surgery. Although this complication has been well documented in THA with modular components, it has been rarely described in preassembled designs. In this report we present a rare case of liner dissociation in a ceramic-on-ceramic pre-assembled cup design. A 41-year-old man who received THA seven years ago, presented with sudden pain in the hip. Radiographic examination confirmed a small dissociation of the liner component in the acetabular shell, as well as radiolucency between the acetabular shell and the ceramic liner, and pneumarthrosis. Revision surgery was carried out six weeks following the liner dissociation. To make an accurate diagnosis, orthopaedic surgeons must be aware of the symptoms of liner dissociation.


Assuntos
Acetábulo , Artroplastia de Quadril , Cerâmica , Prótese de Quadril , Falha de Prótese , Reoperação , Humanos , Masculino , Adulto , Prótese de Quadril/efeitos adversos , Artroplastia de Quadril/efeitos adversos , Acetábulo/cirurgia , Acetábulo/diagnóstico por imagem , Desenho de Prótese
10.
Bone Joint J ; 106-B(5 Supple B): 118-124, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38688513

RESUMO

Aims: Accurate diagnosis of chronic periprosthetic joint infection (PJI) presents a significant challenge for hip surgeons. Preoperative diagnosis is not always easy to establish, making the intraoperative decision-making process crucial in deciding between one- and two-stage revision total hip arthroplasty (THA). Calprotectin is a promising point-of-care novel biomarker that has displayed high accuracy in detecting PJI. We aimed to evaluate the utility of intraoperative calprotectin lateral flow immunoassay (LFI) in THA patients with suspected chronic PJI. Methods: The study included 48 THAs in 48 patients with a clinical suspicion of PJI, but who did not meet European Bone and Joint Infection Society (EBJIS) PJI criteria preoperatively, out of 105 patients undergoing revision THA at our institution for possible PJI between November 2020 and December 2022. Intraoperatively, synovial fluid calprotectin was measured with LFI. Cases with calprotectin levels ≥ 50 mg/l were considered infected and treated with two-stage revision THA; in negative cases, one-stage revision was performed. At least five tissue cultures were obtained; the implants removed were sent for sonication. Results: Calprotectin was positive (≥ 50 mg/l) in 27 cases; out of these, 25 had positive tissue cultures and/or sonication. Calprotectin was negative in 21 cases. There was one false negative case, which had positive tissue cultures. Calprotectin showed an area under the curve of 0.917, sensitivity of 96.2%, specificity of 90.9%, positive predictive value of 92.6%, negative predictive value of 95.2%, positive likelihood ratio of 10.6, and negative likelihood ratio of 0.04. Overall, 45/48 patients were correctly diagnosed and treated by our algorithm, which included intraoperative calprotectin measurement. This yielded a 93.8% concordance with postoperatively assessed EBJIS criteria. Conclusion: Calprotectin can be a valuable tool in facilitating the intraoperative decision-making process for cases in which chronic PJI is suspected and diagnosis cannot be established preoperatively.


Assuntos
Artroplastia de Quadril , Biomarcadores , Tomada de Decisão Clínica , Complexo Antígeno L1 Leucocitário , Infecções Relacionadas à Prótese , Reoperação , Humanos , Infecções Relacionadas à Prótese/diagnóstico , Artroplastia de Quadril/efeitos adversos , Feminino , Masculino , Complexo Antígeno L1 Leucocitário/análise , Idoso , Pessoa de Meia-Idade , Imunoensaio/métodos , Líquido Sinovial/metabolismo , Prótese de Quadril/efeitos adversos , Idoso de 80 Anos ou mais , Cuidados Intraoperatórios/métodos , Estudos Retrospectivos , Sensibilidade e Especificidade
12.
Bone Joint J ; 106-B(5 Supple B): 125-132, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38688510

RESUMO

Aims: Uncemented implants are now commonly used at reimplantation of a two-stage revision total hip arthoplasty (THA) following periprosthetic joint infection (PJI). However, there is a paucity of data on the performance of the most commonly used uncemented femoral implants - modular fluted tapered (MFT) femoral components - in this setting. This study evaluated implant survival, radiological results, and clinical outcomes in a large cohort of reimplantation THAs using MFT components. Methods: We identified 236 reimplantation THAs from a single tertiary care academic institution from September 2000 to September 2020. Two designs of MFT femoral components were used as part of an established two-stage exchange protocol for the treatment of PJI. Mean age at reimplantation was 65 years (SD 11), mean BMI was 32 kg/m2 (SD 7), and 46% (n = 109) were female. Mean follow-up was seven years (SD 4). A competing risk model accounting for death was used. Results: The 15-year cumulative incidence of any revision was 24%. There were 48 revisions, with the most common reasons being dislocation (n = 25) and infection (n = 16). The 15-year cumulative incidence of any reoperation was 28%. Only 13 revisions involved the fluted tapered component (FTC), for a 15-year cumulative incidence of any FTC revision of 8%. Only two FTCs were revised for aseptic loosening, resulting in a 15-year cumulative incidence of FTC revision for aseptic loosening of 1%. Stem subsidence ≥ 5 mm occurred in 2% of unrevised cases. All stems were radiologically stable at most recent follow-up. Mean Harris Hip Score was 69 (SD 20) at most recent follow-up. Conclusion: This series demonstrated that MFT components were durable and reliable in the setting of two-stage reimplantation THA for infection. While the incidence of aseptic loosening was very low, the incidence of any revision was 24% at 15 years, primarily due to dislocation and recurrent PJI.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Desenho de Prótese , Infecções Relacionadas à Prótese , Reoperação , Humanos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/efeitos adversos , Feminino , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/etiologia , Masculino , Prótese de Quadril/efeitos adversos , Idoso , Pessoa de Meia-Idade , Estudos Retrospectivos , Falha de Prótese
13.
Bone Joint J ; 106-B(4): 372-379, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38555938

RESUMO

Aims: Histology is widely used for diagnosis of persistent infection during reimplantation in two-stage revision hip and knee arthroplasty, although data on its utility remain scarce. Therefore, this study aims to assess the predictive value of permanent sections at reimplantation in relation to reinfection risk, and to compare results of permanent and frozen sections. Methods: We retrospectively collected data from 226 patients (90 hips, 136 knees) with periprosthetic joint infection who underwent two-stage revision between August 2011 and September 2021, with a minimum follow-up of one year. Histology was assessed via the SLIM classification. First, we analyzed whether patients with positive permanent sections at reimplantation had higher reinfection rates than patients with negative histology. Further, we compared permanent and frozen section results, and assessed the influence of anatomical regions (knee versus hip), low- versus high-grade infections, as well as first revision versus multiple prior revisions on the histological result at reimplantation. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), chi-squared tests, and Kaplan-Meier estimates were calculated. Results: Overall, the reinfection rate was 18%. A total of 14 out of 82 patients (17%) with positive permanent sections at reimplantation experienced reinfection, compared to 26 of 144 patients (18%) with negative results (p = 0.996). Neither permanent sections nor fresh frozen sections were significantly associated with reinfection, with a sensitivity of 0.35, specificity of 0.63, PPV of 0.17, NPV of 0.81, and accuracy of 58%. Histology was not significantly associated with reinfection or survival time for any of the analyzed sub-groups. Permanent and frozen section results were in agreement for 91% of cases. Conclusion: Permanent and fresh frozen sections at reimplantation in two-stage revision do not serve as a reliable predictor for reinfection.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Prótese de Quadril , Prótese do Joelho , Infecções Relacionadas à Prótese , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Prótese do Joelho/efeitos adversos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Estudos Retrospectivos , Reinfecção , Articulação do Joelho/cirurgia , Reoperação/métodos
14.
Bone Joint J ; 106-B(4): 344-351, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38555949

RESUMO

Aims: Revision total hip arthroplasty in patients with Vancouver type B3 fractures with Paprosky type IIIA, IIIB, and IV femoral defects are difficult to treat. One option for Paprovsky type IIIB and IV defects involves modular cementless, tapered, revision femoral components in conjunction with distal interlocking screws. The aim of this study was to analyze the rate of reoperations and complications and union of the fracture, subsidence of the stem, mortality, and the clinical outcomes in these patients. Methods: A total of 46 femoral components in patients with Vancouver B3 fractures (23 with Paprosky type IIIA, 19 with type IIIB, and four with type IV defects) in 46 patients were revised with a transfemoral approach using a modular, tapered, cementless revision Revitan curved femoral component with distal cone-in-cone fixation and prospectively followed for a mean of 48.8 months (SD 23.9; 24 to 112). The mean age of the patients was 80.4 years (66 to 100). Additional distal interlocking was also used in 23 fractures in which distal cone-in-cone fixation in the isthmus was < 3 cm. Results: One patient (2.2%) died during the first postoperative year. After six months, 43 patients (93.5%) had osseous, and three had fibrous consolidation of the fracture and the bony flap, 42 (91.3%) had bony ingrowth and four had stable fibrous fixation of the stem. No patient had radiolucency around the interlocking screws and no screw broke. One patient had non-progressive subsidence and two had a dislocation. The mean Harris Hip Score increased from of 57.8 points (SD 7.9) three months postoperatively to 76.1 points (SD 10.7) 24 months postoperatively. Conclusion: The 2° tapered, fluted revision femoral component with distal cone-in-cone-fixation, combined with additional distal interlocking in patients with bony deficiency at the isthmus, led to reproducibly good results in patients with a Vancouver B3 fracture and Paprosky type IIIA, IIIB, and IV defects with regard to union of the fracture, subsidence or loosening of the stem, and clinical outcomes.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Fraturas Periprotéticas/cirurgia , Fraturas Periprotéticas/etiologia , Prótese de Quadril/efeitos adversos , Resultado do Tratamento , Desenho de Prótese , Reoperação/métodos , Fraturas do Fêmur/cirurgia , Estudos Retrospectivos
15.
Bone Joint J ; 106-B(4): 312-318, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38555951

RESUMO

The advent of modular porous metal augments has ushered in a new form of treatment for acetabular bone loss. The function of an augment can be seen as reducing the size of a defect or reconstituting the anterosuperior/posteroinferior columns and/or allowing supplementary fixation. Depending on the function of the augment, the surgeon can decide on the sequence of introduction of the hemispherical shell, before or after the augment. Augments should always, however, be used with cement to form a unit with the acetabular component. Given their versatility, augments also allow the use of a hemispherical shell in a position that restores the centre of rotation and biomechanics of the hip. Progressive shedding or the appearance of metal debris is a particular finding with augments and, with other radiological signs of failure, should be recognized on serial radiographs. Mid- to long-term outcomes in studies reporting the use of augments with hemispherical shells in revision total hip arthroplasty have shown rates of survival of > 90%. However, a higher risk of failure has been reported when augments have been used for patients with chronic pelvic discontinuity.


Assuntos
Artroplastia de Quadril , Doenças Ósseas Metabólicas , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Porosidade , Acetábulo/cirurgia , Reoperação , Metais , Falha de Prótese , Estudos Retrospectivos , Seguimentos
16.
Medicina (Kaunas) ; 60(3)2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38541184

RESUMO

Background and objectives: wear and corrosion can lead to the gross failure of the Morse taper junction with the consequent fracture of the true neck of the prosthetic stem in hip arthroplasty. Materials and Methods: 58-year-old male patient, with a BMI of 38 kg/m2. Because of avascular necrosis, in 2007, a metal-on-metal total hip arthroplasty was implanted in him, with a TMZF stem and a Co-Cr head. In December 2020, he complained of acute left hip pain associated with the deterioration of his left leg and total functional impairment, preceded by the crunching of the hip. X-rays and CT scan showed a fracture of the prosthetic neck that necessitated prosthetic revision surgery. A Scanning Electron Microscope (SEM) analysis of the retrieved prosthetic components was conducted. Results: Macroscopically, the trunnion showed a typical bird beak appearance, due to a massive material loss of about half of its volume. The gross material loss apparently due to abrasion extended beyond the trunnion to the point of failure on the true neck about half a centimeter distal from the taper. SEM analysis demonstrated fatigue rupture modes, and the crack began close to the neck's surface. On the lateral surface, several scratches were found, suggesting an intense wear that could be due to abrasion. Conclusions: The analysis we conducted on the explanted THA showed a ductile rupture, began close to the upper surface of the prosthetic neck where the presence of many scratches had concentrated stresses and led to a fatigue fracture.


Assuntos
Artroplastia de Quadril , Fraturas Ósseas , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Microscopia Eletrônica de Varredura , Falha de Prótese , Desenho de Prótese
17.
Int Orthop ; 48(5): 1165-1170, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38438578

RESUMO

PURPOSE: Conversion of a fused hip to a total hip arthroplasty (THA) is technically challenging due to the loss of anatomical references. Here, a reproducible technique using the direct anterior approach (DAA) with a regular surgical table under fluoroscopic guidance is described, which has several advantages over traditional such as lateral or posterior approaches. METHODS: There were reported 11 cases of ankylosis hip that were converted to THA using the same surgical technique protocol. Clinical and radiographic outcomes were recorded at 3.2 years of follow-up. A detailed preoperative evaluation was performed, including a pelvis radiological evaluation and magnetic resonance image (MRI) to assess the integrity of the periarticular soft tissue and flexor muscles. RESULTS: The DAA has considerable advantages, such as allowing more precise targeting during surgery, avoiding the risk of pseudoarthrosis due to the absence of a trochanteric osteotomy, preserving the abductors, and allowing an easier-to-use of intraoperative fluoroscopy due to the supine position. Besides, the use of a standard table reduces surgical time and allows assessment of limb length, hip stability, and impingement in all planes in an intraoperative dynamic range, which decreases postoperative complications. CONCLUSION: Conversion from hip fusion to THA is a rare and complex procedure. The use of DAA with a standard table and fluoroscopy helps to avoid high complications since it allows a dynamic intra-operative examination of the range of motion to rule out impingements, reduces the risk of dislocation, and allows leg lengthening verification.


Assuntos
Anquilose , Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Fluoroscopia/métodos , Radiografia , Anquilose/etiologia , Estudos Retrospectivos
18.
Int Orthop ; 48(5): 1171-1178, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38443715

RESUMO

PURPOSE: After cemented total hip arthroplasty, the risk of periprosthetic fracture (PPF) of taper-slip stems is higher than that of composite-beam stems. We aimed to assess the conditions resulting in PPFs of taper-slip stems using a falling weight. METHODS: Taper-slip stems were fixed to five types of simulated bone models using bone cement, and the fractures were evaluated by dropping stainless-steel weights from a predetermined height onto the heads. The periprosthetic fracture height in 50% of the bone models (PPFH50) was calculated using the staircase method. RESULTS: For the fixation with 0° of flexion, the values for PPFH50 were 61 ± 11, 60 ± 13, above 110, 108 ± 49, and 78 ± 12 cm for the cobalt-chromium-molybdenum alloy, stainless steel alloy (SUS), titanium alloy (Ti), smooth surface, and thick cement mantle models, respectively; for the fixation with 10° of flexion (considering flexure), the PPFH50 values were 77 ± 5, 85 ± 9, 90 ± 2, 89 ± 5, and 81 ± 11 cm, respectively. The fracture rates of the polished-surface stems were 78.6 and 35.7% at the proximal and distal sites, respectively (p < 0.05); the fracture rates of the smooth-surface stems were 14.2 and 100%, respectively (p < 0.05). CONCLUSION: The impact tests demonstrated that the conditions that were less likely to cause PPFs were use of Ti, a smooth surface, a thick cement mantle, and probably, use of SUS.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Fraturas Periprotéticas/epidemiologia , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Prótese de Quadril/efeitos adversos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Reoperação/efeitos adversos , Cimentos Ósseos , Desenho de Prótese , Ligas , Fraturas do Fêmur/cirurgia
19.
Int Orthop ; 48(5): 1241-1247, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38499712

RESUMO

PURPOSE: The aims of this study were to evaluate the survivorships of a new generation cementless DMC with tripod additional fixation in revision total hip arthroplasty and complications at a minimum five year follow-up. METHODS: One hundred and fifteen revisions (THA) treated with tripod DMC performed between 2009 and 2015 were included in this retrospective study. Acetabular defects were classified as Paprosky 1 (n = 38, 33%), 2 (n = 75, 65%) or 3 (n = 2, 2%). Unipolar or bipolar revision was performed for the following indications: aseptic acetabular loosening (63%), infection (14%), aseptic bipolar loosening (11%), instability (4%), aseptic femoral loosening (3%), ALVAL (3%) and iliopsoas impingement (2%). Mean follow-up was 9.4 years ± two (range, 5 to 14). RESULTS: At the final follow-up, a single episode of dislocation occurred within three months after the procedure (0.8%) with no revision. Three cases of aseptic loosening were diagnosed (2.6%). Four infections (3.5%) required reoperation: three required a two stage bipolar revision; one was treated by DAIR procedure. At the latest follow-up, the survivorship of the acetabular cup for aseptic loosening was 98% [95% CI (91.2-99.4)] and for any reasons was 94.4% [95% CI (90.1%-98.9%)]; the mean HHS improved from 60 points (range, 18-94 points) to 83 points (range, 37-100 points) (p < .001). CONCLUSION: This study reports a low complication rate in favour of the use of a tripod DMC in revision THA with a satisfactory survivorship at a ten year follow-up.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Falha de Prótese , Acetábulo/cirurgia , Reoperação , Desenho de Prótese , Seguimentos
20.
Eur J Orthop Surg Traumatol ; 34(4): 1927-1935, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38462554

RESUMO

BACKGROUND: Periprosthetic femoral fractures (PFF) carry significant morbidity following arthroplasty for femoral neck fracture (FNF). This study assessed fracture complications following arthroplasty for FNF and the effect of cement fixation of the femoral component on intraoperative and post-operative PFF. METHODS: Between February 2014 and September 2021, 740 patients with a FNF who underwent arthroplasty were analyzed for demographics, surgical management, use of cement for fixation of the femoral component, and subsequent PFF. Variables were compared with Mann-Whitney or Chi-square as appropriate. Multivariate logistic regression was used to assess independent risk factors associated with intraoperative or post-operative PFF. RESULTS: There were 163 THAs (41% cemented) and 577 HAs (95% cemented). There were 28 PFFs (3.8%): 18 post-operative and 10 intraoperative. Fewer post-operative PFFs occurred with cemented stems (1.63% vs. 6.30%, p = 0.002). Mean time from surgery to presentation with post-operative PFF was 14 months (0-45 months). Mean follow-up time was 10.3 months (range: 0-75.7 months). In multivariate regression, use of cement and THA was independently associated with decreased post-operative PFF (cement: OR 0.112, 95% CI 0.036-0.352, p < 0.001 and THA: OR 0.249, 95% CI 0.064-0.961, p = 0.044). More intraoperative fractures occurred during THA (3.68% vs. 0.69%, p = 0.004) and non-cemented procedures (5.51% vs. 0.49%, p < 0.001). In multivariate regression, use of cement was protective against intraoperative fracture (OR 0.100, CI 0.017-0.571, p = 0.010). CONCLUSIONS: In patients with a FNF treated with arthroplasty, cementing the femoral component is associated with a lower risk of intraoperative and post-operative PFF. Choice of procedure may be based on patient factors and surgeon preference.


Assuntos
Artroplastia de Quadril , Cimentos Ósseos , Fraturas do Colo Femoral , Fraturas Periprotéticas , Humanos , Fraturas do Colo Femoral/cirurgia , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/prevenção & controle , Fraturas Periprotéticas/cirurgia , Masculino , Feminino , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Idoso , Fatores de Risco , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Cimentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA