Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 586
Filtrar
1.
J Refract Surg ; 40(7): e468-e479, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007809

RESUMO

PURPOSE: To assess visual and refractive outcomes and visual function after bilateral RayOne Trifocal toric and nontoric intraocular lens (IOL) (Rayner) implantation in patients with presbyopia. METHODS: Charts of patients with presbyopia who underwent refractive lens exchange with bilateral implantation of the RayOne Trifocal IOL (toric and non-toric) were retrospectively reviewed. Visual and refractive outcomes were evaluated at 3 months. Patient satisfaction, spectacle independence, and visual disturbance profile were assessed by questionnaires. RESULTS: A total of 5,226 patients were assigned to one of two groups: 1,010 patients had toric IOL implantation (toric group) and 4,216 patients received the non-toric model (non-toric group). Mean ± standard deviation visual acuity at 3 months for the toric group was binocular uncorrected distance visual acuity (UDVA) of 0.07 ± 0.11 logMAR, monocular corrected distance visual acuity (CDVA) of 0.05 ± 0.07 logMAR, binocular uncorrected near visual acuity (UNVA) at 40 cm of 0.10 ± 0.09 logMAR, binocular uncorrected intermediate visual acuity (UIVA) at 40 cm of 0.13 ± 0.12 logMAR, postoperative spherical equivalent (SE) of -0.21 ± 0.47 diopters (D), and cylinder of -0.34 ± 0.40 D. The non-toric group had binocular UDVA of 0.04 ± 0.08 logMAR, monocular CDVA of 0.05 ± 0.07 logMAR, binocular UNVA of 0.10 ± 0.08 logMAR, binocular UIVA of 0.13 ± 0.11 logMAR, SE of -0.08 ± 0.38 D, and cylinder of -0.28 ± 0.34 D. No statistically significant differences were found in achieving spectacle independence and there were high levels of satisfaction in both groups. CONCLUSIONS: In this retrospective analysis with more than 5,000 patients, both the toric and non-toric RayOne Trifocal IOL models provided good visual performance at all distances, resulting in excellent levels of spectacle independence and patient satisfaction. [J Refract Surg. 2024;40(7):e468-e479.].


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares Multifocais , Satisfação do Paciente , Facoemulsificação , Presbiopia , Pseudofacia , Refração Ocular , Visão Binocular , Acuidade Visual , Humanos , Presbiopia/cirurgia , Presbiopia/fisiopatologia , Acuidade Visual/fisiologia , Estudos Retrospectivos , Feminino , Masculino , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Inquéritos e Questionários , Visão Binocular/fisiologia , Pseudofacia/fisiopatologia , Idoso , Reoperação , Adulto , Desenho de Prótese , Lentes Intraoculares , Resultado do Tratamento
2.
J Refract Surg ; 40(7): e480-e489, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007817

RESUMO

PURPOSE: To evaluate the effectiveness, safety, and stability of a modified PRESBYOND Laser Blended Vision protocol (Carl Zeiss Meditec AG) for correcting hyperopic astigmatism and presbyopia, using Custom Refractive Software Master (CRSM) targeting over a 6-month period. METHODS: A total of 636 eyes of 318 patients with a mean age of 51.05 ± 4.71 years (range: 40 to 60 years) met the inclusion and exclusion criteria. All patients completed a 6-month follow-up. CRSM software was used to generate ablation profiles for the MEL90 excimer laser (Carl Zeiss Meditec AG). The target refraction was emmetropic for the dominant eyes and between -0.75 and -1.12 diopters (D) for the near eyes. RESULTS: Visual and refractive results were studied separately by the dominant and non-dominant eyes. The mean attempt to correct for spherical equivalent refraction was +2.17 ± 1.16 D (range: -1.00 to +5.37 D). The mean attempted cylinder was -0.60 ± 0.75 D (range: -4.00 to 0.00 D). All eyes monocularly achieved uncorrected distance visual acuity (UDVA) of 20/25 or better after refractive treatment and 88% achieved 20/20. Binocularly all eyes achieved UDVA of 20/25 or better and 96.54% achieved 20/20. Ninety-eight percent of the patients maintained their corrected distance visual acuity before surgery and UDVA 6 months after surgery. CONCLUSIONS: This hyperopic micro-anisometropia protocol with PRESBYOND Laser Blended Vision was an effective, safe, and well-tolerated refractive treatment. It was an effective procedure with excellent results for UDVA and uncorrected near visual acuity and demonstrates that binocular summation exists. [ J Refract Surg. 2024;40(7):e480-e489.].


Assuntos
Astigmatismo , Hiperopia , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Presbiopia , Refração Ocular , Software , Acuidade Visual , Humanos , Presbiopia/cirurgia , Presbiopia/fisiopatologia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Lasers de Excimer/uso terapêutico , Masculino , Hiperopia/fisiopatologia , Hiperopia/cirurgia , Pessoa de Meia-Idade , Feminino , Adulto , Astigmatismo/fisiopatologia , Astigmatismo/cirurgia , Resultado do Tratamento , Anisometropia/fisiopatologia , Anisometropia/cirurgia , Topografia da Córnea , Seguimentos , Estudos Prospectivos , Córnea/fisiopatologia , Córnea/cirurgia
3.
BMC Ophthalmol ; 24(1): 269, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38918765

RESUMO

BACKGROUND: To evaluate the optical performance and safety of a new multifocal lens with a novel optical design featuring two additional foci (or intensifiers) in patients with cataract and presbyopia. METHODS: In this single-center, non-randomized prospective observational study, 31 patients underwent implantation of the new multifocal IOL between March 2020 and November 2021 at a tertiary clinical center in Buenos Aires and Ramos Mejia, Argentina. Postoperative examinations with emphasis on uncorrected and corrected visual acuity at distance and near and at two different intermediate distances (80 cm and 60 cm) were performed during the 3 postoperative months. RESULTS: Of the 31 patients who underwent implantation of the new IOL, 30 underwent bilateral surgery (61 eyes in total). At 3 months, all 61 eyes had an uncorrected distance visual acuity (UCDVA) of at least 0.15 logMAR; 57 eyes (93%) had an uncorrected distance visual acuity (UCDVA) of 0.1 logMAR and 27 eyes (44%) had an UCDVA of 0.0 logMAR. At 80 cm, 60 eyes (98%) had an uncorrected intermediate visual acuity (UCIVA) of at least 0.1 log MAR and 48 eyes (79%) had an UCIVA of 0.0 logMAR. CONCLUSION: The new multifocal IOL with a novel optical concept (5 foci) showed a wide range of visual acuity especially at intermediate and near distances in patients undergoing cataract surgery. Uncorrected visual acuity was excellent at all tested distances, monocularly and binocularly, spectacle independence and patient satisfaction were high.


Assuntos
Lentes Intraoculares Multifocais , Presbiopia , Desenho de Prótese , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Estudos Prospectivos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Presbiopia/fisiopatologia , Presbiopia/cirurgia , Refração Ocular/fisiologia , Implante de Lente Intraocular , Pseudofacia/fisiopatologia , Facoemulsificação , Catarata/complicações , Catarata/fisiopatologia , Lentes Intraoculares , Idoso de 80 Anos ou mais , Seguimentos
4.
Vestn Oftalmol ; 140(2): 40-46, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38742497

RESUMO

Extended depth of focus (EDOF) intraocular lenses (IOLs) are the latest IOL designs. In recent years, several models of EDOF IOLs have become available in Russia, two of which (Tecnis Symfony and Acrysof IQ Vivity) are implanted in our clinic. Comparative studies devoted to the results of implantation of the new EDOF IOLs are rare in the available literature. PURPOSE: This article compares the outcomes of implantation of two EDOF IOLs in patients with presbyopia and/or cataract. MATERIAL AND METHODS: The prospective study included 60 patients (81 eyes) after implantation of EDOF IOL Tecnis Symfony (32 patients, 45 eyes; group 1) or EDOF IOL AcrySof IQ Vivity (28 patients, 36 eyes; group 2). The mean follow-up period was 3.9±1.3 months. RESULTS: All groups showed a significant (p<0.05) increase in uncorrected near visual acuity (UCNVA), intermediate visual acuity (UCIVA), and distance visual acuity (UCDVA) at the maximum follow-up time compared to preoperative values. In group 1, the best corrected near visual acuity (BCNVA) increased from 0.61±0.10 to 0.82±0.16 at the maximum follow-up time, and in group 2 - from 0.58±0.08 to 0.67±0.12 (p>0.05). Both groups showed a significant increase in best corrected intermediate and distance visual acuity (BCIVA and BCDVA) at the maximum follow-up time. The increase in the indicator compared to the preoperative period was not significant in both groups (p>0.05). The frequency of side optical phenomena was low in both groups. No significant differences were found between the groups (p>0.05). CONCLUSION: This study presents a comparative analysis of the results of implantation of two different EDOF IOLs. Both lenses were comparable in most of the studied parameters, including providing good distance and intermediate vision, functional near vision, as well as a low frequency of side optical phenomena. In all cases the patients were satisfied with the results of the surgical intervention.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Presbiopia , Acuidade Visual , Humanos , Masculino , Feminino , Implante de Lente Intraocular/métodos , Pessoa de Meia-Idade , Presbiopia/cirurgia , Presbiopia/fisiopatologia , Desenho de Prótese , Estudos Prospectivos , Idoso , Resultado do Tratamento , Catarata/fisiopatologia , Catarata/diagnóstico , Refração Ocular/fisiologia , Percepção de Profundidade/fisiologia , Federação Russa
5.
Sci Rep ; 14(1): 8386, 2024 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600286

RESUMO

This prospective, non-randomized, comparative study aimed to compare the visual outcomes and patient satisfaction after implantations of three presbyopia-correcting intraocular lenses (IOLs) after myopic refractive surgery. It was conducted from January 2020 to December 2021 in Shanghai Heping Eye Hospital. Patients were divided into three groups based on the type of IOL implanted. The visual acuity, refractive stability, high-order aberrations, objective visual quality, spectacle independence, and visual function index 14 questionnaire scores of the three groups were compared. This study included 78 eyes of 39 patients: 26 eyes with 839MP, 26 eyes with MF30, and 26 eyes with ZXR00. Uncorrected distance visual acuity improved significantly for all three groups. For a pupil diameter of 4.0 mm, the spherical aberrations of the three groups were 0.33 ± 0.16 µ, 0.50 ± 0.08 µ, and 0.39 ± 0.10 µ, respectively. The spectacle independence for distance vision was over 90% in each group; for near vision, it was only 25% for the ZXR00 group. All three types of presbyopia-correcting IOLs improved visual quality in post-LASIK or PRK patients. However, the high incidence of photic phenomena after presbyopia-correcting IOL implantation in patients who have undergone myopic LASIK should not be neglected.


Assuntos
Lentes Intraoculares , Miopia , Presbiopia , Humanos , Presbiopia/cirurgia , Implante de Lente Intraocular , Satisfação do Paciente , Estudos Prospectivos , China , Miopia/cirurgia , Desenho de Prótese
6.
Turk J Ophthalmol ; 54(2): 63-68, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38644781

RESUMO

Objectives: To evaluate the clinical results of a new trifocal intraocular lens (IOL) with sinusoidal design by comparing with a traditional trifocal IOL. Materials and Methods: A total of 79 patients undergoing uneventful microincisional cataract surgery with bilateral implantation of one of two types of trifocal IOLs, the Acriva Trinova IOL (VSY) or Acrysof IQ PanOptix IOL (Alcon), were enrolled in this prospective study. Visual and refractive outcomes, contrast sensitivity (CS), and defocus curve were assessed at 3 months after surgery. Patient satisfaction and incidence of photic phenomena were also evaluated. Results: The number of patients/eyes were 48/96 in the Trinova group and 31/62 in the PanOptix group. There were no significant differences between the groups for monocular and binocular corrected/uncorrected distance or intermediate (at 60 cm) and near visual acuities (VA) postoperatively. The Trinova group had statistically significantly better intermediate VA at 80 cm than the PanOptix group (p<0.05). The CS results of both groups were within the normal limits. In the binocular defocus curve of both IOLs, we observed a peak of good VA at 0.0 diopters defocus and a useful wide range for intermediate distances. The incidence of photic phenomena in the Trinova group was lower at postoperative 1 month (p<0.05) but this difference disappeared at 3 months. A total of 47 patients (97.9%) in the Trinova group and 30 patients (96.7%) in the PanOptix group stated that they would recommend the same IOL. Conclusion: Both trifocal IOLs provide good visual quality outcomes and patient satisfaction.


Assuntos
Lentes Intraoculares Multifocais , Presbiopia , Desenho de Prótese , Refração Ocular , Acuidade Visual , Humanos , Estudos Prospectivos , Feminino , Masculino , Acuidade Visual/fisiologia , Idoso , Pessoa de Meia-Idade , Presbiopia/fisiopatologia , Presbiopia/cirurgia , Refração Ocular/fisiologia , Visão Binocular/fisiologia , Satisfação do Paciente , Sensibilidades de Contraste/fisiologia , Facoemulsificação , Seguimentos , Implante de Lente Intraocular/métodos , Lentes Intraoculares
7.
BMC Ophthalmol ; 24(1): 172, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627651

RESUMO

PURPOSE: To assess the efficacy and safety of various intraocular lenses (IOLs), including standard monofocal, bifocal, trifocal, extended depth of focus (EDOF), and enhanced monofocal IOLs, post-cataract surgery through a network meta-analysis. METHODS: A systematic search of PubMed, Cochrane Library, and Web of Science was conducted to identify relevant studies from the past 5 years. Parameters such as binocular visual acuities, spectacle independence, contrast sensitivity (CS), and optical quality were used to evaluate efficacy and safety. Data from the selected studies were analyzed using Review Manager 5.4 and STATA 17.0 software. RESULTS: Twenty-eight Randomized Controlled Trials (RCTs) comprising 2465 subjects were included. Trifocal IOLs exhibited superior uncorrected near visual acuity (UNVA) compared to monofocal IOLs (MD: -0.35; 95% CI: -0.48, -0.22). Both trifocal (AcrySof IQ PanOptix IOLs group MD: -0.13; 95% CI: -0.21, -0.06) and EDOF IOLs (MD: -0.13; 95% CI: -0.17, -0.09) showed better uncorrected intermediate visual acuity (UIVA) than monofocal IOLs. Trifocal IOLs ranked highest in spectacle independence at various distances (AT LISAtri 839MP group: SUCRA 97.5% for distance, 80.7% for intermediate; AcrySof IQ PanOptix group: SUCRA 83.0% for near). CONCLUSIONS: For cataract patients who want to treat presbyopia, trifocal IOLs demonstrated better visual acuity and spectacle independence at near distances. Different types of trifocal IOL characteristics differ. EDOF and enhanced monofocal IOLs have improved visual quality at intermediate distances.Therefore, It is very important to select the appropriate IOLs based on the lens characteristics and patient needs.


Assuntos
Catarata , Lentes Intraoculares , Facoemulsificação , Presbiopia , Humanos , Implante de Lente Intraocular , Presbiopia/cirurgia , Refração Ocular , Satisfação do Paciente , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto
8.
J Cataract Refract Surg ; 50(7): 724-732, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38530027

RESUMO

PURPOSE: To evaluate the clinical outcomes of the toric version of a presbyopia-correcting intraocular lens (IOL) based on the combination of a diffractive-based extended depth-of-focus (EDOF) pattern and a diffractive multifocal platform. SETTING: Miranza COI Bilbao, Bilbao, Spain. DESIGN: Prospective case series. METHODS: 35 patients (51 to 84 years) with corneal astigmatism ranging from 0.75 to 2.19 diopters (D) undergoing bilateral cataract surgery with implantation of the Synergy Toric II IOL were evaluated during a 3-month follow-up. Visual acuity, refraction, defocus curve, and patient-reported outcomes with the Catquest-9SF questionnaire were analyzed. A vectorial analysis was used to analyze the accuracy of astigmatic correction. RESULTS: Mean 3-month monocular postoperative uncorrected distance, intermediate (80 cm) and near (40 cm) visual acuities were 0.06 ± 0.11 logMAR, 0.13 ± 0.12 logMAR, and 0.13 ± 0.09 logMAR, respectively. Mean monocular distance-corrected intermediate (80 cm) and near visual acuity (40 cm) were 0.11 ± 0.12 logMAR and 0.10 ± 0.10 logMAR, respectively. Mean binocular defocus curve showed visual acuities of 0.10 logMAR or better for defocus levels from +0.50 to -2.50 D. Residual cylinder was within ±0.50 D in 97.0% of eyes. The surgically induced astigmatism prediction error ranged between -0.49 D and 0.50 D, with a mean value of 0.04 ± 0.16 D. Mean absolute IOL rotation was 3.79 ± 2.94 degrees. Significant improvements were found in all Rasch-calibrated scores obtained with Catquest-9SF ( P < .001). CONCLUSIONS: The implantation of the toric presbyopia-correcting IOL evaluated provides an efficacious astigmatic correction while providing a fully restoration of the visual function across different distances.


Assuntos
Astigmatismo , Implante de Lente Intraocular , Lentes Intraoculares , Presbiopia , Refração Ocular , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Presbiopia/cirurgia , Presbiopia/fisiopatologia , Estudos Prospectivos , Idoso , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Masculino , Feminino , Astigmatismo/fisiopatologia , Astigmatismo/cirurgia , Facoemulsificação , Desenho de Prótese , Pseudofacia/fisiopatologia , Inquéritos e Questionários , Resultado do Tratamento
9.
J Cataract Refract Surg ; 50(6): 578-584, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38305420

RESUMO

PURPOSE: To evaluate subjective and objective outcomes after combined implantation of an extended depth-of-focus (EDOF) intraocular lens (IOL) and a combined technology multifocal lens (CT-IOL). SETTING: 2 clinical practices (Carolina Eyecare Physicians, Center For Sight) in the United States. DESIGN: Prospective, unmasked, multicenter, nonrandomized bilateral eye study. METHODS: Patients interested in reducing their dependence on spectacles were implanted with an EDOF IOL in the dominant eye and a CT-IOL in the nondominant eye. Refractive and visual acuity (VA) data at various distances (4 m, 66 cm, 40 cm, and 33 cm) were collected 3 months postsurgery, along with the distance-corrected binocular defocus curve and responses to questionnaires related to spectacle independence, visual disturbances, and overall visual function. RESULTS: Data from 37 participants were analyzed. The distance-corrected binocular defocus curve showed a mean VA better than 0.1 logMAR (20/25) at all vergences from +1.00 to -2.50 diopters (D). 36 participants (97%) had an uncorrected binocular VA of 0.3 logMAR or better, at all test distances. 70% of participants (26/37) reported never wearing spectacles at any distance, and 84% (31/37) were "completely" or "mostly" satisfied with their overall vision after surgery. Halos were the disturbance reported most frequently and reported as most bothersome, with difficulty driving at night the most common visual function issue. Difficulty reading was the next most reported issue. Overall eyesight was rated as "excellent" or "good" by 92% (34/37) of participants. CONCLUSIONS: This combined EDOF/CT-IOL approach was well-tolerated by participants and provided some potential benefits relative to bilateral implantation of either lens.


Assuntos
Implante de Lente Intraocular , Facoemulsificação , Presbiopia , Pseudofacia , Refração Ocular , Visão Binocular , Acuidade Visual , Humanos , Estudos Prospectivos , Acuidade Visual/fisiologia , Presbiopia/fisiopatologia , Presbiopia/cirurgia , Visão Binocular/fisiologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Refração Ocular/fisiologia , Pseudofacia/fisiopatologia , Satisfação do Paciente , Lentes Intraoculares , Inquéritos e Questionários , Lentes Intraoculares Multifocais , Dominância Ocular/fisiologia , Percepção de Profundidade/fisiologia , Desenho de Prótese
10.
Int Ophthalmol ; 44(1): 54, 2024 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-38341384

RESUMO

OBJECTIVE: To compare the visual performance of two presbyopia-correcting intraocular lenses (IOLs) that combine both bifocal and extended depth-of-focus profiles, Artis® Symbiose® Plus (Symbiose Plus; Cristalens Industrie, Lannion, France) and Tecnis® Synergy® (Synergy; Johnson & Johnson Vision, Santa Ana, CA, USA). METHODS: The medical records of patients with cataract bilaterally implanted with either Symbiose Plus or Synergy between January 2022 and January 2023 were assessed. The principal measures of postoperative findings included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near (40 and 33 cm) visual acuity (UNVA), objective optical quality (OOQ) parameters, distance-corrected defocus curve analysis, and surveys of subjective satisfaction. RESULTS: Total of 96 eyes from 48 patients were enrolled. Each group was equally composed of 24 patients, 48 eyes. There were no significant differences between the two groups on baseline characteristics. Both IOLs displayed excellent binocular UDVA, CDVA, and UNVA (40 and 33 cm) with no statistical difference (p = 0.467(UDVA), p = 0.584(CDVA), p = 0.096(40-cm UNVA), and p = 0.621(33-cm UNVA)). However, with regard to UIVA, the Synergy group showed significantly superior results (p < 0.001). In contrast, the Symbiose Plus group showed significantly better results on OOQ parameters and patient-reported quality of vision survey outcomes (both p < 0.001). CONCLUSIONS: Both IOLs provided a decent continuous range of vision from near to far distance.


Assuntos
Lentes Intraoculares , Facoemulsificação , Presbiopia , Humanos , Refração Ocular , Implante de Lente Intraocular/métodos , Presbiopia/cirurgia , Satisfação do Paciente , Desenho de Prótese , Visão Binocular
11.
J Cataract Refract Surg ; 50(4): 413-419, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38237073

RESUMO

PURPOSE: To objectively quantify glare of intraocular lenses (IOLs) using a diffractive principle to extend the visual range and to identify models with increased susceptibility to inducing glare. SETTING: David J Apple Laboratory, Heidelberg, Germany. DESIGN: Laboratory investigation. METHODS: Glare was assessed by means of a straylight parameter with a standard C-Quant intended for 7 degrees. In addition, 2 C-Quant modifications were used to test lower angles (ie, 2.5 degrees and 3.5 degrees). The following IOL models were assessed: PanOptix, AT Lisa Tri, Synergy, and Triumf, the latter 2 with chromatic aberration correction at distance. Straylight from trifocal IOLs was compared against a monofocal W-60R lens. The C-Quant test was performed through the studied IOLs by using additional optical components attached to their ocular. RESULTS: Straylight (deg 2 sr -1 ) of the control was <1 at all tested angles, with the trifocal models showing comparable straylight at 7 degrees. At 3.5 degrees, Triumf's straylight increased to 15.5 ± 0.6, followed by Synergy (6.2 ± 1.1), PanOptix (4.1 ± 0.3), and AT Lisa Tri (2.0 ± 0.8). The chromatic aberration-correcting models demonstrated correspondingly higher straylight (Synergy: 18.8 ± 1.3; Triumf: 17.3 ± 0.5) at 2.5 degrees compared with PanOptix (4.3 ± 0.4), AT Lisa Tri (2.1 ± 0.1), and monofocal IOLs yielding minimal or no increase. CONCLUSIONS: Trifocal IOLs induced increased straylight, but it was limited to lower angles, which may cause difficulties detecting these effects using a standard clinical approach. The latest IOL designs featuring chromatic aberration correction at far focus seem more susceptible than the established trifocal IOLs to inducing a glare phenomenon.


Assuntos
Cristalino , Lentes Intraoculares , Presbiopia , Humanos , Ofuscação , Presbiopia/cirurgia , Óculos , Desenho de Prótese
12.
J Refract Surg ; 40(1): e1-e9, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38190559

RESUMO

PURPOSE: To determine the visual outcomes and safety 12 months after implantation of the Presbia Flexivue Microlens refractive corneal inlay. METHODS: In this prospective, non-randomized trial, 22 patients with a mean age of 52.54 ± 2.86 years were implanted with the Flexivue Microlens refractive corneal inlay in the non-dominant eye at the Department of Ophthalmology, Goethe University, Frankfurt, Germany. Corrected near, intermediate, and distance (CNVA, CIVA, and CDVA) visual acuity and uncorrected near, intermediate, and distance (UNVA, UIVA, and UDVA) visual acuity, manifest refraction, subjective quality of vision, endothelial cell count, and contrast sensitivity were measured 1 day, 1 week, and 1, 3, 6, and 12 months postoperatively. RESULTS: For binocular CDVA, no patient lost two or more lines and 30% lost only one line at the 12-month visit. In the eye that had surgery, 85% of the patients lost two or more lines of UDVA, which was statistically significant. Sixty-five percent of the patients gained one or more lines in binocular UIVA, and 80% achieved 20/40 or better in DCIVA. UNVA showed a statistically significant improvement, with 90% of the patients achieving 20/40 or better 12 months after implantation. A total of 85% gained two or more lines in binocular UNVA. CONCLUSIONS: This refractive corneal inlay showed an improvement in binocular UNVA, UIVA, CNVA, and CIVA, whereas binocular CDVA and UDVA were not statistically affected. [J Refract Surg. 2024;40(1):e1-e9.].


Assuntos
Presbiopia , Humanos , Pessoa de Meia-Idade , Presbiopia/cirurgia , Estudos Prospectivos , Refração Ocular , Testes Visuais , Acuidade Visual
14.
Curr Opin Ophthalmol ; 35(1): 4-10, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37962882

RESUMO

PURPOSE OF REVIEW: Corneal refractive surgery (CRS) is one of the most popular eye procedures, with more than 40 million cases performed globally. As CRS-treated patients age and develop cataract, the number of cases that require additional preoperative considerations and management will increase around the world. Thus, we provide an up-to-date, concise overview of the considerations and outcomes of cataract surgery in eyes with previous CRS, including surface ablation, laser in-situ keratomileusis (LASIK), and small-incision lenticule extraction (SMILE). RECENT FINDINGS: Challenges associated with accurate biometry in eyes with CRS have been mitigated recently through total keratometry, ray tracing, intraoperative aberrometry, and machine learning assisted intraocular lens (IOL) power calculation formulas to improve prediction. Emerging studies have highlighted the superior performance of ray tracing and/or total keratometry-based formulas for IOL power calculation in eyes with previous SMILE. Dry eye remains a common side effect after cataract surgery, especially in eyes with CRS, though the risk appears to be lower after SMILE than LASIK (in the short-term). Recent presbyopia-correcting IOL designs such as extended depth of focus (EDOF) IOLs may be suitable in carefully selected eyes with previous CRS. SUMMARY: Ophthalmologists will increasingly face challenges associated with the surgical management of cataract in patients with prior CRS. Careful preoperative assessment of the ocular surface, appropriate use of IOL power calculation formulas, and strategies for presbyopia correction are key to achieve good clinical and refractive outcomes and patient satisfaction. Recent advances in CRS techniques, such as SMILE, may pose new challenges for such eyes in the future.


Assuntos
Catarata , Ceratomileuse Assistida por Excimer Laser In Situ , Lentes Intraoculares , Miopia , Presbiopia , Humanos , Implante de Lente Intraocular/métodos , Presbiopia/cirurgia , Miopia/cirurgia , Refração Ocular , Biometria/métodos , Óptica e Fotônica , Estudos Retrospectivos
15.
J Cataract Refract Surg ; 50(1): 57-63, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37702453

RESUMO

PURPOSE: To evaluate the efficacy of topical pilocarpine HCl 1.25% (Pilo) in treating presbyopia in individuals with or without a history of laser vision correction (laser-assisted in situ keratomileusis [LASIK] or photorefractive keratectomy [PRK]). SETTING: Multiple clinical sites. DESIGN: Pooled analysis of 2 identically designed prospective, randomized, vehicle-controlled studies (GEMINI 1 and 2). METHODS: Adults aged 40 to 55 years with presbyopia received once-daily Pilo or vehicle bilaterally for 30 days. Responder rates for ≥3-line improvement in mesopic, high-contrast, binocular distance-corrected near visual acuity (DCNVA) were determined on day 30. RESULTS: Among participants with a history of LASIK/PRK (n = 39 in the Pilo group, n = 41 in the vehicle group), responder rates for ≥3-line improvement in DCNVA on day 30 at hours 0.25, 0.5, 1, 3, 6, 8, and 10, respectively, were 16.7%, 38.9%, 41.7%, 37.8%, 16.2%, 13.9%, and 8.3% with Pilo and 0.0%, 2.6%, 10.5%, 5.1%, 7.7%, 2.6%, and 0.0% with vehicle. Responder rates in the LASIK/PRK subgroup were significantly higher with Pilo than vehicle at hours 0.25 ( P = .0087), 0.5 ( P = .0001), 1 ( P = .0022), and 3 ( P = .0005). In contrast, there were no significant differences in responder rates between Pilo-treated participants with and without LASIK/PRK. Among non-LASIK/PRK participants in the Pilo group (n = 336), responder rates for ≥3-line improvement in DCNVA on day 30 at hours 0.25, 0.5, 1, 3, 6, 8, and 10, respectively, were 16.8%, 32.7%, 39.0%, 28.0%, 17.4%, 12.6%, and 10.5%. CONCLUSIONS: Pilo treatment effectively and similarly improved DCNVA in presbyopes with or without a history of laser vision correction.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Ceratectomia Fotorrefrativa , Presbiopia , Adulto , Humanos , Pilocarpina/uso terapêutico , Refração Ocular , Lasers de Excimer/uso terapêutico , Estudos Prospectivos , Presbiopia/cirurgia , Resultado do Tratamento , Miopia/cirurgia , Ensaios Clínicos Controlados Aleatórios como Assunto
16.
Curr Opin Ophthalmol ; 35(1): 28-33, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37910172

RESUMO

PURPOSE OF REVIEW: Options for addressing presbyopia with intraocular lens (IOL) implantation have become more varied and sophisticated. We reviewed recent literature on multifocal and extended depth of focus (EDOF) IOLs in order to provide insight on their respective advantages, with emphasis on the visual outcomes of each design. RECENT FINDINGS: Increased patient age, spectral domain optical coherence tomography (SD-OCT) abnormalities, abnormal optical axis measurements, and better preoperative visual acuity have been implicated as predictors of worse postoperative vision or visual quality in multifocal IOLs. Despite differences in objective outcomes, patient-reported outcomes such as satisfaction are consistently similar between multifocal and EDOF IOLs. EDOFs may have slightly lower rates of spectacle independence than trifocals, but there is more support for their use in the setting of with other ocular conditions. SUMMARY: Multifocal and EDOF IOLs are both viable options for patients who wish to preserve near vision. Given their similar objective performance in many aspects, enabling patients to make informed decisions based on their expectations and visual requirements is critical to postoperative satisfaction. Evidence for advanced technology IOL implantation in pediatric patients remains inconclusive.


Assuntos
Linfoma Intraocular , Lentes Intraoculares , Lentes Intraoculares Multifocais , Facoemulsificação , Presbiopia , Humanos , Implante de Lente Intraocular/métodos , Satisfação do Paciente , Presbiopia/cirurgia , Desenho de Prótese , Pseudofacia , Refração Ocular , Acuidade Visual
18.
Retin Cases Brief Rep ; 18(1): 98-100, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35963010

RESUMO

BACKGROUND/PURPOSE: Retinal detachment has previously been reported in association with topical miotic use for the treatment of glaucoma. Pilocarpine hydrochloride 1.25% was recently approved by the Food and Drug Administration for the treatment of presbyopia, with no reports of associated retinal detachments in the clinical trial data. METHODS: Case report. RESULTS: Two novel cases of unilateral retinal detachment occurring within 10 days of the initiation of pilocarpine 1.25% for the treatment of presbyopia were described. The patients were pseudophakic men in their 60s or 70s with preexisting retinal detachment risk factors, such as high myopia, lattice degeneration, and prior retinal detachment. Both affected eyes were treated with pars plana vitrectomy and gas endotamponade with an uncomplicated postoperative course. CONCLUSION: Retinal detachment may be associated with the use of pilocarpine 1.25%. Caution should be used when considering prescribing this medication in patients with preexisting retinal abnormality.


Assuntos
Presbiopia , Descolamento Retiniano , Masculino , Humanos , Descolamento Retiniano/induzido quimicamente , Descolamento Retiniano/cirurgia , Pilocarpina/efeitos adversos , Presbiopia/complicações , Presbiopia/cirurgia , Acuidade Visual , Vitrectomia/efeitos adversos , Soluções Oftálmicas , Resultado do Tratamento , Estudos Retrospectivos
19.
J Refract Surg ; 39(12): 817-824, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38063834

RESUMO

PURPOSE: To compare visual outcomes and satisfaction in patients with emmetropia, presbyopia, and greater or lesser residual accommodation who undergo unilateral or bilateral implantation of a trifocal diffractive intraocular lens (IOL). METHODS: A multicenter, multisurgeon study was performed to evaluate outcomes in patients with emmetropia and presbyopia who underwent refractive lens exchange followed by implantation of a FineVision trifocal IOL (PhysIOL). The inclusion criteria were as follows: emmetropia, sphere -0.25 to +0.50 diopters (D), cylinder less than 0.75 D, and manifest refractive spherical equivalent (MRSE) of -0.25 to +0.25 D. All patients also had to have an uncorrected distance visual acuity (UDVA) of Snellen 0.9 or better in each eye. The sample was divided into different clusters based on two variables: eyes operated on (monocular or binocular) and age either younger than 55 years or 55 years or older. Thus, four possible groups were created. Visual and refractive performance, patient satisfaction, and spectacle independence were assessed. RESULTS: A total of 690 eyes from 431 patients were evaluated. There was no difference in postoperative uncorrected (UDVA) and corrected (CDVA) distance visual acuity between the groups. Binocular uncorrected near vision (UNVA) was better in patients who underwent surgery on both eyes regardless of age (median [interquartile range]: 0.00 [0.00; 0.10] vs 0.10 [0.00; 0.10] logMAR; P < .001). Binocular uncorrected intermediate vision (UIVA) was better in patients who underwent surgery on both eyes aged younger than 55 years than in those who underwent surgery in one eye aged 55 years or older (median [interquartile range]: 0.18 [0.10; 0.18] vs 0.30 [0.18; 0.30] logMAR; P < .001). The efficacy and safety indexes were 0.98 ± 0.09 and 1.01 ± 0.06, respectively. A total of 93.3% of eyes were within the 0.50 D range in postoperative MRSE. Visual dysphotopsia was worse in patients with both eyes operated on, although the differences were not statistically significant. CONCLUSIONS: The study shows that after refractive lens exchange, patients with emmetropia and presbyopia who received a trifocal IOL in one or both eyes achieved good UNVA, UIVA, and UDVA. Regarding near binocular visual acuity, results were better for patients who underwent surgery on both eyes than for those who underwent surgery on one eye. Regarding binocular intermediate visual acuity, patients aged younger than 55 years with both lenses replaced had better results than those 55 years or older with only one lens replaced. However, no significant differences were observed in UDVA or patient satisfaction. [J Refract Surg. 2023;39(12):817-824.].


Assuntos
Lentes Intraoculares , Facoemulsificação , Presbiopia , Humanos , Emetropia , Presbiopia/cirurgia , Refração Ocular , Satisfação do Paciente , Desenho de Prótese
20.
Transl Vis Sci Technol ; 12(12): 19, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-38127324

RESUMO

Purpose: This optical bench study was designed to evaluate and compare the halos generated by presbyopia-correcting intraocular lenses (PCIOLs) and monofocal intraocular lenses (IOLs), with or without lens decentration, using an optical bench to simulate the headlight of a distant vehicle in mesopic conditions. Methods: Halos generated by six nondiffractive and 10 diffractive IOLs with different dioptric add powers were evaluated using a high dynamic range bench system. Halo intensities were compared by assessing the area under the measured intensity profile curve to compute the relative halo magnitude (RHM). Results: Nondiffractive PCIOLs produced smaller and less intense bench halo images than diffractive ones. RHM measurements ranged from 964 to 1896. Monofocal IOLs produced lower RHM values, whereas diffractive PCIOLs generated higher ones. When decentered by 0.5 mm with respect to the system aperture, more obviously asymmetric halo image profiles were observed in diffractive compared with nondiffractive PCIOLs. Conclusions: Simulated bench halos of nondiffractive PCIOLs are smaller and less intense than those of diffractive PCIOLs. Additional clinical studies assessing standardized patient-reported outcomes measures are required to correlate these bench results with patient satisfaction. Translational Relevance: This study contrasts the design-related simulated bench halos of nondiffractive and diffractive PCIOLs, aiming to elucidate their impact on halo perception.


Assuntos
Lentes Intraoculares , Presbiopia , Humanos , Presbiopia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA