Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.995
Filtrar
1.
Harefuah ; 163(5): 298-304, 2024 May.
Artigo em Hebraico | MEDLINE | ID: mdl-38734943

RESUMO

INTRODUCTION: Glaucoma is a progressive optic neuropathy and is the leading cause of preventable irreversible blindness worldwide. Glaucoma causes progressive visual field loss and can have significant implications on the patient's quality of life. Lowering intraocular pressure (IOP) is the only treatment proven to prevent vision loss from glaucoma. It is achieved using medication, laser treatment and surgery. The treatment paradigm of glaucoma has been one whereby surgical intervention has been left for advanced cases due to a variety of reasons, mainly concerning safety and long term success. The past two decades have seen a paradigm shift towards earlier IOP lowering interventions using a wide array of different technologies in the laser and surgical spaces. This review aims to understand the background to this paradigm shift, its necessity, and its potential impact on the vision and life of glaucoma patients.


Assuntos
Glaucoma , Pressão Intraocular , Terapia a Laser , Qualidade de Vida , Humanos , Glaucoma/terapia , Glaucoma/cirurgia , Pressão Intraocular/fisiologia , Terapia a Laser/métodos , Cegueira/etiologia , Cegueira/prevenção & controle , Campos Visuais/fisiologia , Progressão da Doença , Doenças do Nervo Óptico/etiologia , Doenças do Nervo Óptico/terapia
4.
Invest Ophthalmol Vis Sci ; 65(5): 15, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38717426

RESUMO

Purpose: Mutations in the genes encoding type IV collagen alpha 1 (COL4A1) and alpha 2 (COL4A2) cause a multisystem disorder that includes ocular anterior segment dysgenesis (ASD) and glaucoma. We previously showed that transforming growth factor beta (TGFß) signaling was elevated in developing anterior segments from Col4a1 mutant mice and that reducing TGFß signaling ameliorated ASD, supporting a role for the TGFß pathway in disease pathogenesis. Here, we tested whether altered TGFß signaling also contributes to glaucoma-related phenotypes in Col4a1 mutant mice. Methods: To test the role of TGFß signaling in glaucoma-relevant phenotypes, we genetically reduced TGFß signaling using mice with mutated Tgfbr2, which encodes the common receptor for all TGFß ligands in Col4a1+/G1344D mice. We performed slit-lamp biomicroscopy and optical coherence tomography for qualitative and quantitative analyses of anterior and posterior ocular segments, histological analyses of ocular tissues and optic nerves, and intraocular pressure assessments using rebound tonometry. Results: Col4a1+/G1344D mice showed defects of the ocular drainage structures, including iridocorneal adhesions, and phenotypes consistent with glaucomatous neurodegeneration, including thinning of the nerve fiber layer, retinal ganglion cell loss, optic nerve head excavation, and optic nerve degeneration. We found that reducing TGFß receptor 2 (TGFBR2) was protective for ASD, ameliorated ocular drainage structure defects, and protected against glaucomatous neurodegeneration in Col4a1+/G1344D mice. Conclusions: Our results suggest that elevated TGFß signaling contributes to glaucomatous neurodegeneration in Col4a1 mutant mice.


Assuntos
Colágeno Tipo IV , Glaucoma , Pressão Intraocular , Receptor do Fator de Crescimento Transformador beta Tipo II , Transdução de Sinais , Tomografia de Coerência Óptica , Fator de Crescimento Transformador beta , Animais , Camundongos , Colágeno Tipo IV/metabolismo , Colágeno Tipo IV/genética , Transdução de Sinais/fisiologia , Pressão Intraocular/fisiologia , Glaucoma/metabolismo , Glaucoma/genética , Glaucoma/patologia , Fator de Crescimento Transformador beta/metabolismo , Receptor do Fator de Crescimento Transformador beta Tipo II/genética , Receptor do Fator de Crescimento Transformador beta Tipo II/metabolismo , Modelos Animais de Doenças , Doenças do Nervo Óptico/metabolismo , Doenças do Nervo Óptico/genética , Camundongos Endogâmicos C57BL , Células Ganglionares da Retina/patologia , Células Ganglionares da Retina/metabolismo , Segmento Anterior do Olho/metabolismo , Segmento Anterior do Olho/patologia , Nervo Óptico/patologia , Nervo Óptico/metabolismo , Microscopia com Lâmpada de Fenda , Fenótipo , Tonometria Ocular , Mutação
5.
Vestn Oftalmol ; 140(2): 54-62, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38742499

RESUMO

PURPOSE: This study analyzes the influence of various factors on the hypotensive effect of selective laser trabeculoplasty (SLT) in patients with primary open-angle glaucoma (POAG). MATERIAL AND METHODS: A retrospective study of the SLT effect was performed in 582 patients (756 eyes; mean age - 71.9±9.5 years) with POAG stages I-III. The level of intraocular pressure (IOP) decrease was assessed at 1 day, 1, 3, 6, and 12 months after SLT. The relationship between the hypotensive effect and age, gender, glaucoma stage, initial IOP level, number and type of instilled drugs, presence of intraocular lenses, and the surgeon performing the intervention were analyzed. RESULTS: In the entire sample, the hypotensive effect of SLT after 1 day was 4.1±3.4 mm Hg, after 1, 3, 6, and 12 months - 3.7±4.8; 3.5±3.8; 3.1±3.4 and 2.3±3.8 mm Hg, respectively. The hypotensive effect of SLT was most dependent on the preoperative IOP level (R>0.64, p<0.05). No significant correlation was found between the hypotensive effect and the stage of POAG, gender, age, number of hypotensive drugs, phakia/aphakia, and the surgeon. A weaker hypotensive effect of SLT was found in eyes receiving monotherapy with α2-adrenoceptor agonists (p<0.03) and a combination of four drugs (p<0.02). CONCLUSION: SLT is an effective method of additional IOP reduction in POAG at any stage and with any hypotensive regimen. At the same time, the results of its use in real clinical practice indicate the need for more careful IOP control after the procedure, especially in eyes with POAG stage III, as well as in eyes without hypotensive therapy and on the maximum drop regimen.


Assuntos
Glaucoma de Ângulo Aberto , Pressão Intraocular , Terapia a Laser , Trabeculectomia , Humanos , Glaucoma de Ângulo Aberto/cirurgia , Glaucoma de Ângulo Aberto/fisiopatologia , Trabeculectomia/métodos , Feminino , Masculino , Idoso , Pressão Intraocular/fisiologia , Estudos Retrospectivos , Terapia a Laser/métodos , Resultado do Tratamento , Pessoa de Meia-Idade , Anti-Hipertensivos/uso terapêutico
6.
Invest Ophthalmol Vis Sci ; 65(5): 1, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38691092

RESUMO

Purpose: Elevated intraocular pressure (IOP) is thought to cause lamina cribrosa (LC) blood vessel distortions and potentially collapse, adversely affecting LC hemodynamics, reducing oxygenation, and triggering, or contributing to, glaucomatous neuropathy. We assessed the robustness of LC perfusion and oxygenation to vessel collapses. Methods: From histology, we reconstructed three-dimensional eye-specific LC vessel networks of two healthy monkey eyes. We used numerical simulations to estimate LC perfusion and from this the oxygenation. We then evaluated the effects of collapsing a fraction of LC vessels (0%-36%). The collapsed vessels were selected through three scenarios: stochastic (collapse randomly), systematic (collapse strictly by the magnitude of local experimentally determined IOP-induced compression), and mixed (a combination of stochastic and systematic). Results: LC blood flow decreased linearly as vessels collapsed-faster for stochastic and mixed scenarios and slower for the systematic one. LC regions suffering severe hypoxia (oxygen <8 mm Hg) increased proportionally to the collapsed vessels in the systematic scenario. For the stochastic and mixed scenarios, severe hypoxia did not occur until 15% of vessels collapsed. Some LC regions had higher perfusion and oxygenation as vessels collapsed elsewhere. Some severely hypoxic regions maintained normal blood flow. Results were equivalent for both networks and patterns of experimental IOP-induced compression. Conclusions: LC blood flow was sensitive to distributed vessel collapses (stochastic and mixed) and moderately vulnerable to clustered collapses (systematic). Conversely, LC oxygenation was robust to distributed vessel collapses and sensitive to clustered collapses. Locally normal flow does not imply adequate oxygenation. The actual nature of IOP-induced vessel collapse remains unknown.


Assuntos
Pressão Intraocular , Disco Óptico , Oxigênio , Fluxo Sanguíneo Regional , Animais , Pressão Intraocular/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Disco Óptico/irrigação sanguínea , Hipertensão Ocular/fisiopatologia , Macaca mulatta , Imageamento Tridimensional , Modelos Animais de Doenças
7.
BMJ Open ; 14(5): e078018, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38692719

RESUMO

OBJECTIVE: To investigate the differences in myopia prevalence and ocular biometry in children and adolescents in Chongqing and Tibet, China. DESIGN: Cross-sectional study. SETTING: The study included children and adolescents aged 6-18 years in Chongqing, a low-altitude region, and in Qamdo, a high-altitude region of Tibet. PARTICIPANTS: A total of 448 participants in Qamdo, Tibet, and 748 participants in Chongqing were enrolled in this study. METHODS: All participants underwent uncorrected visual acuity assessment, non-cycloplegic refraction, axial length (AL) measurement, intraocular pressure (IOP) measurement and corneal tomography. And the participants were grouped according to age (6-8, 9-11, 12-14 and 15-18 years group), and altitude of location (primary school students: group A (average altitude: 325 m), group B (average altitude: 2300 m), group C (average altitude: 3250 and 3170 m) and group D (average altitude: 3870 m)). RESULTS: There was no statistical difference in mean age (12.09±3.15 vs 12.2±3.10, p=0.549) and sex distribution (males, 50.4% vs 47.6%, p=0.339) between the two groups. The Tibet group presented greater spherical equivalent (SE, -0.63 (-2.00, 0.13) vs -0.88 (-2.88, -0.13), p<0.001), shorter AL (23.45±1.02 vs 23.92±1.19, p<0.001), lower prevalence of myopia (39.7% vs 47.6%, p=0.008) and flatter mean curvature power of the cornea (Km, 43.06±1.4 vs 43.26±1.36, p=0.014) than the Chongqing group. Further analysis based on age subgroups revealed that the Tibet group had a lower prevalence of myopia and higher SE in the 12-14, and 15-18 years old groups, shorter AL in the 9-11, 12-14 and 15-18 years old groups, and lower AL to corneal radius of curvature ratio (AL/CR) in all age subgroups compared with the Chongqing group, while Km was similar between the two groups in each age subgroup. Simple linear regression analysis showed that SE decreased with age in both the Tibet and Chongqing groups, with the Tibet group exhibiting a slower rate of decrease (p<0.001). AL and AL/CR increased with age in both the Tibet and Chongqing groups, but the rate of increase was slower in the Tibet group (p<0.001 of both). Multiple linear regression analysis revealed that AL had the greatest effect on SE in both groups, followed by Km. In addition, the children and adolescents in Tibet presented thinner corneal thickness (CCT, p<0.001), smaller white to white distance (WTW, p<0.001), lower IOP (p<0.001) and deeper anterior chamber depth (ACD, p=0.015) than in Chongqing. Comparison of altitude subgroups showed that the prevalence of myopia (p=0.002), SE (p=0.031), AL (p=0.001) and AL/CR (p<0.001) of children at different altitudes was statistically different but the Km (p=0.189) were similar. The highest altitude, Tengchen County, exhibited the lowest prevalence of myopia and greatest SE among children, and the mean AL also decreased with increasing altitude. CONCLUSIONS: Myopia prevalence in Tibet was comparable with that in Chongqing for students aged 6-8 and 9-11 years but was lower and myopia progressed more slowly for students aged 12-14 and 15-18 years than in Chongqing, and AL was the main contributor for this difference, which may be related to higher ultraviolet radiation exposure and lower IOP in children and adolescents at high altitude in Tibet. Differences in AL and AL/CR between Tibet and Chongqing children and adolescents manifested earlier than in SE, underscoring the importance of AL measurement in myopia screening.


Assuntos
Altitude , Biometria , Miopia , Refração Ocular , Humanos , Adolescente , Criança , Estudos Transversais , Masculino , Feminino , Tibet/epidemiologia , Miopia/epidemiologia , Prevalência , China/epidemiologia , Refração Ocular/fisiologia , Acuidade Visual , Comprimento Axial do Olho/diagnóstico por imagem , Pressão Intraocular/fisiologia , Córnea/diagnóstico por imagem , Córnea/patologia , Córnea/anatomia & histologia
8.
Invest Ophthalmol Vis Sci ; 65(5): 13, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38713484

RESUMO

Purpose: The purpose of this study was to measure intraocular pressure (IOP) elevation while applying standard gonioscopy, selective laser trabeculoplasty (SLT), and laser iridotomy procedural lenses. Methods: Twelve cadaver eyes were mounted to a custom apparatus and cannulated with a pressure transducer which measured IOP. The apparatus was mounted to a load cell which measured the force on the eye. Six ophthalmologists performed simulated gonioscopy (Sussman 4 mirror lens), SLT (Latina lens), and laser iridotomy (Abraham lens) while a computer recorded IOP (mm Hg) and force (grams). The main outcome measures were IOP and force applied to the eye globe during ophthalmic diagnostics and procedures. Results: The average IOP's during gonioscopy, SLT, and laser iridotomy were 43.2 ± 16.9 mm Hg, 39.8 ± 9.9 mm Hg, and 42.7 ± 12.6 mm Hg, respectively. The mean force on the eye for the Sussman, Latina, and Abraham lens was 40.3 ± 26.4 grams, 66.7 ± 29.8 grams, and 65.5 ± 35.9 grams, respectively. The average force applied to the eye by the Sussman lens was significantly lower than both the Latina lens (P = 0.0008) and the Abraham lens (P = 0.001). During gonioscopy indentation, IOP elevated on average to 80.5 ± 22.6 mm Hg. During simulated laser iridotomy tamponade, IOP elevated on average to 82.3 ± 27.2 mm Hg. Conclusions: In cadaver eyes, the use of standard ophthalmic procedural lenses elevated IOP by approximately 20 mm Hg above baseline.


Assuntos
Cadáver , Gonioscopia , Pressão Intraocular , Iris , Terapia a Laser , Trabeculectomia , Humanos , Pressão Intraocular/fisiologia , Terapia a Laser/métodos , Iris/cirurgia , Trabeculectomia/métodos , Tonometria Ocular , Idoso , Iridectomia/métodos , Feminino , Masculino , Idoso de 80 Anos ou mais
9.
BMC Ophthalmol ; 24(1): 209, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38724962

RESUMO

BACKGROUD: The aim of this study was to investigate the associations between fluctuation in blood pressure (BP), ocular perfusion pressure (OPP) and visual field (VF) progression in normal-tension glaucoma (NTG). METHODS: This prospective, longitudinal study included 44 patients with NTG. Only newly diagnosed NTG patients who had not been treated with a glaucoma medication were included. Patients were examined every year for 7 years. Intraocular pressure (IOP), heart rate (HR), systolic BP (SBP), diastolic BP (DBP), ocular perfusion pressure (OPP), and diastolic ocular perfusion pressure (DOPP) were measured at the same time. Ophthalmic examinations, including perimetry, were performed also. Initial VF were compared with follow-up data after 7 years. RESULTS: After 7 years of follow-up, 9 of the 44 patients showed VF progression. The standard deviation (SD) of SBP and OPP were significantly associated with VF progression (P = 0.007, < 0.001, respectively). Multiple regression analysis showed that VF progression was significantly associated with SD of OPP (odds ratio, OR = 2.012, 95% CI = 1.016-3.985; P = 0.045). CONCLUSIONS: Fluctuation in OPP was associated with VF progression in patients with NTG.


Assuntos
Pressão Sanguínea , Progressão da Doença , Pressão Intraocular , Glaucoma de Baixa Tensão , Campos Visuais , Humanos , Glaucoma de Baixa Tensão/fisiopatologia , Campos Visuais/fisiologia , Masculino , Feminino , Pressão Intraocular/fisiologia , Estudos Prospectivos , Pessoa de Meia-Idade , Pressão Sanguínea/fisiologia , Seguimentos , Idoso , Testes de Campo Visual , Adulto
10.
Transl Vis Sci Technol ; 13(5): 8, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38739084

RESUMO

Purpose: This study aimed to evaluate the ocular characteristics associated with spontaneously high myopia in adult nonhuman primates (NHPs). Methods: A total of 537 eyes of 277 macaques with an average age of 18.53 ± 3.01 years (range = 5-26 years), raised in a controlled environment, were included. We measured ocular parameters, including spherical equivalent (SE), axial length (AXL), and intraocular pressure. The 45-degree fundus images centered on the macula and the disc assessed the fundus tessellation and parapapillary atrophy (PPA). Additionally, optical coherence tomography (OCT) was used to measure the thickness of the retinal nerve fiber layer (RNFL). Results: The mean SE was -1.58 ± 3.71 diopters (D). The mean AXL was 18.76 ± 0.86 mm. The prevalence rate of high myopia was 17.7%. As myopia aggravated, the AXL increased (r = -0.498, P < 0.001). Compared with non-high myopia, highly myopic eyes had a greater AXL (P < 0.001), less RNFL thickness (P = 0.004), a higher incidence of PPA (P < 0.001), and elevated grades of fundus tessellation (P < 0.001). The binary logistic regression was performed, which showed PPA (odds ratio [OR] = 4.924, 95% confidence interval [CI] = 2.375-10.207, P < 0.001) and higher grades of fundus tessellation (OR = 1.865, 95% CI = 1.474-2.361, P < 0.001) were independent risk characteristics for high myopia. Conclusions: In NHPs, a higher grade of fundus tessellation and PPA were significant biomarkers of high myopia. Translational Relevance: The study demonstrates adult NHPs raised in conditioned rooms have a similar prevalence and highly consistent fundus changes with human beings, which strengthens the foundation for utilizing macaques as an animal model in high myopic studies.


Assuntos
Fundo de Olho , Tomografia de Coerência Óptica , Animais , Masculino , Feminino , Modelos Animais de Doenças , Disco Óptico/patologia , Disco Óptico/diagnóstico por imagem , Atrofia Óptica/patologia , Atrofia Óptica/epidemiologia , Pressão Intraocular/fisiologia , Miopia Degenerativa/patologia , Miopia Degenerativa/epidemiologia , Fibras Nervosas/patologia , Comprimento Axial do Olho/patologia , Células Ganglionares da Retina/patologia , Miopia/patologia , Miopia/epidemiologia , Miopia/veterinária
11.
Transl Vis Sci Technol ; 13(5): 9, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38743409

RESUMO

Purpose: To assess the diagnostic performance and structure-function association of retinal retardance (RR), a customized metric measured by a prototype polarization-sensitive optical coherence tomography (PS-OCT), across various stages of glaucoma. Methods: This cross-sectional pilot study analyzed 170 eyes from 49 healthy individuals and 68 patients with glaucoma. The patients underwent PS-OCT imaging and conventional spectral-domain optical coherence tomography (SD-OCT), as well as visual field (VF) tests. Parameters including RR and retinal nerve fiber layer thickness (RNFLT) were extracted from identical circumpapillary regions of the fundus. Glaucomatous eyes were categorized into early, moderate, or severe stages based on VF mean deviation (MD). The diagnostic performance of RR and RNFLT in discriminating glaucoma from controls was assessed using receiver operating characteristic (ROC) curves. Correlations among VF-MD, RR, and RNFLT were evaluated and compared within different groups of disease severity. Results: The diagnostic performance of both RR and RNFLT was comparable for glaucoma detection (RR AUC = 0.98, RNFLT AUC = 0.97; P = 0.553). RR showed better structure-function association with VF-MD than RNFLT (RR VF-MD = 0.68, RNFLT VF-MD = 0.58; z = 1.99; P = 0.047) in glaucoma cases, especially in severe glaucoma, where the correlation between VF-MD and RR (r = 0.73) was significantly stronger than with RNFLT (r = 0.43, z = 1.96, P = 0.050). In eyes with early and moderate glaucoma, the structure-function association was similar when using RNFLT and RR. Conclusions: RR and RNFLT have similar performance in glaucoma diagnosis. However, in patients with glaucoma especially severe glaucoma, RR showed a stronger correlation with VF test results. Further research is needed to validate RR as an indicator for severe glaucoma evaluation and to explore the benefits of using PS-OCT in clinical practice. Translational Relevance: We demonstrated that PS-OCT has the potential to evaluate the status of RNFL structural damage in eyes with severe glaucoma, which is currently challenging in clinics.


Assuntos
Glaucoma , Fibras Nervosas , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Campos Visuais , Humanos , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Masculino , Feminino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Projetos Piloto , Campos Visuais/fisiologia , Glaucoma/fisiopatologia , Glaucoma/diagnóstico por imagem , Idoso , Células Ganglionares da Retina/patologia , Curva ROC , Testes de Campo Visual/métodos , Adulto , Pressão Intraocular/fisiologia
12.
Invest Ophthalmol Vis Sci ; 65(5): 34, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38776117

RESUMO

Purpose: A thin cornea is a potent risk factor for glaucoma. The underlying mechanisms remain unexplained. It has been postulated that central corneal thickness (CCT) may be a surrogate for biomechanical parameters of the posterior eye. In this study, we aimed to explore correlations of biomechanical responses between the cornea and the optic nerve head (ONH) and the peripapillary sclera (PPS) to elevated intraocular pressure (IOP), the primary risk factor of glaucoma. Methods: Inflation tests were performed in nine pairs of human donor globes. One eye of each pair was randomly assigned for cornea or posterior eye inflation. IOP was raised from 5 to 30 millimeters of mercury (mmHg) at 0.5 mmHg steps in the whole globe and the cornea or the ONH/PPS was imaged using a 50 MHz ultrasound probe. Correlation-based ultrasound speckle tracking was used to calculate tissue displacements and strains. Associations of radial, tangential, and shear strains at 30 mmHg between the cornea and the ONH or PPS were evaluated. Results: Corneal shear strain was significantly correlated with ONH shear strain (R = 0.857, P = 0.003) and PPS shear strain (R = 0.724, P = 0.028). CCT was not correlated with any strains in the cornea, ONH, or PPS. Conclusions: Our results suggested that an eye that experiences a larger shear strain in the cornea would likely experience a larger shear strain in its ONH and PPS at IOP elevations. The strong correlation between the cornea's and the ONH's shear response to IOP provides new insights and suggests a plausible explanation of the cornea's connection to glaucoma risk.


Assuntos
Córnea , Pressão Intraocular , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagem , Córnea/diagnóstico por imagem , Córnea/fisiologia , Pressão Intraocular/fisiologia , Fenômenos Biomecânicos/fisiologia , Idoso , Pessoa de Meia-Idade , Esclera/fisiologia , Esclera/diagnóstico por imagem , Masculino , Feminino , Glaucoma/fisiopatologia , Idoso de 80 Anos ou mais , Doadores de Tecidos , Adulto
13.
Invest Ophthalmol Vis Sci ; 65(5): 33, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38771569

RESUMO

Purpose: This study explored early (contrast discrimination) and intermediate (global form perception) visual processing in primary subtypes of glaucoma: primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG). We aimed to understand early and intermediate visual processing in POAG and PACG, matched for similar visual field defect severity. Methods: Early visual processing was measured using a contrast discrimination task described by Porkorny and Smith (1997), and intermediate processing using a global form perception task using glass pattern coherence thresholds. Thresholds were determined centrally and at a single midperipheral location (12.5°) in a quadrant without visual field defects. Controls were tested in corresponding quadrants to individuals with glaucoma. Results: Sixty participants (20 POAG, 20 PACG, and 20 age-matched controls), aged 50 to 77 years, were included. Visual field defects were matched between POAG and PACG, with mean deviation values of -6.53 ± 4.46 (range: -1.5 to -16.85) dB and -6.2 ± 4.24 (range: -1.37 to -16.42) dB, respectively. Two-Way ANOVA revealed significant differences in thresholds between the glaucoma groups and the control group for both contrast discrimination and global form perception tasks, with higher thresholds in the glaucoma groups. Post hoc analyses showed no significant contrast discrimination difference between POAG and PACG, but POAG had significantly higher thresholds than PACG for form perception. Conclusions: In form perception, POAG showed slightly worse performance than PACG, suggesting that individuals with POAG may experience more severe functional damage than PACG of similar visual field severity.


Assuntos
Sensibilidades de Contraste , Percepção de Forma , Glaucoma de Ângulo Fechado , Glaucoma de Ângulo Aberto , Campos Visuais , Humanos , Glaucoma de Ângulo Aberto/fisiopatologia , Glaucoma de Ângulo Fechado/fisiopatologia , Pessoa de Meia-Idade , Idoso , Masculino , Feminino , Campos Visuais/fisiologia , Sensibilidades de Contraste/fisiologia , Percepção de Forma/fisiologia , Pressão Intraocular/fisiologia , Limiar Sensorial/fisiologia , Testes de Campo Visual
14.
Invest Ophthalmol Vis Sci ; 65(5): 32, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38771570

RESUMO

Purpose: To evaluate VEGF-C-induced lymphoproliferation in conjunction with 5-fluorouracil (5-FU) antimetabolite treatment in a rabbit glaucoma filtration surgery (GFS) model. Methods: Thirty-two rabbits underwent GFS and were assigned to four groups (n = 8 each) defined by subconjunctival drug treatment: (a) VEGF-C combined with 5-FU, (b) 5-FU, (c) VEGF-C, (d) and control. Bleb survival, bleb measurements, and IOP were evaluated over 30 days. At the end, histology and anterior segment OCT were performed on some eyes. mRNA was isolated from the remaining eyes for RT-PCR evaluation of vessel-specific markers (lymphatics, podoplanin and LYVE-1; and blood vessels, CD31). Results: Qualitatively and quantitatively, VEGF-C combined with 5-FU resulted in blebs which were posteriorly longer and wider than the other conditions: vs. 5-FU (P = 0.043 for longer, P = 0.046 for wider), vs. VEGF-C (P < 0.001, P < 0.001) and vs. control (P < 0.001, P < 0.001). After 30 days, the VEGF-C combined with 5-FU condition resulted in longer bleb survival compared with 5-FU (P = 0.025), VEGF-C (P < 0.001), and control (P < 0.001). Only the VEGF-C combined with 5-FU condition showed a negative correlation between IOP and time that was statistically significant (r = -0.533; P = 0.034). Anterior segment OCT and histology demonstrated larger blebs for the VEGF-C combined with 5-FU condition. Only conditions including VEGF-C led to increased expression of lymphatic markers (LYVE-1, P < 0.001-0.008 and podoplanin, P = 0.002-0.011). Expression of CD31 was not different between the groups (P = 0.978). Conclusions: Adding VEGF-C lymphoproliferation to standard antimetabolite treatment improved rabbit GFS success and may suggest a future strategy to improve human GFSs.


Assuntos
Modelos Animais de Doenças , Fluoruracila , Glaucoma , Pressão Intraocular , Trabeculectomia , Fator C de Crescimento do Endotélio Vascular , Animais , Coelhos , Fluoruracila/uso terapêutico , Fluoruracila/farmacologia , Glaucoma/cirurgia , Glaucoma/fisiopatologia , Glaucoma/tratamento farmacológico , Fator C de Crescimento do Endotélio Vascular/metabolismo , Trabeculectomia/métodos , Pressão Intraocular/fisiologia , Antimetabólitos/farmacologia , Antimetabólitos/uso terapêutico , Tomografia de Coerência Óptica , Túnica Conjuntiva , RNA Mensageiro/genética
15.
Int Ophthalmol ; 44(1): 226, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38758396

RESUMO

PURPOSE: Glaucoma and multiple sclerosis (MS) can cause optic disc pathology and, in this way, affect optical coherence tomography (OCT) data. In this context, the objective of this study is to investigate the changes in the mean, quadrant, and sector data measured by OCT in glaucoma and MS patients. METHODS: The sample of this prospective cohort study consisted of 42 MS patients (84 eyes), 34 Primary open-angle glaucomas patients (67 eyes), and 24 healthy control subjects (48 eyes). The MS group was divided into two groups according to the presence of a history of optic neuritis. Accordingly, those with a history of optic neuritis were included in the MS ON group, and those without a history of optic neuritis were included in the MS NON group. The differences between these groups in the mean, quadrant, and sector data related to the retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) were evaluated. RESULTS: Superior nasal (SN), superior temporal (ST), inferior nasal (IN), and superior quadrant (SUP) values were significantly lower in the glaucoma group than in the MS group (p < 0.05). The mean superior GCC (GCC SUP) value was significantly lower in the MS ON group than in the glaucoma group (p < 0.05). On the other hand, SN, ST, inferior temporal (IT), IN, average RNFL (AVE RNFL), semi-average superior RNFL (SUP AVE RNFL), semi-average inferior RNFL (INF AVE RNFL), SUP, and inferior quadrant RNFL (INF) values were significantly lower in the glaucoma group than in the MS NON group (p < 0.05). CONCLUSION: RNFL and GCC parameters get thinner in MS and glaucoma patients. While the inferior and superior RNFL quadrants are more frequently affected in glaucoma patients, the affected quadrants vary according to the presence of a history of optic neuritis in MS patients. It is noteworthy that the GCC superior quadrant was thin in MS ON patients. The findings of this study indicate that OCT data may be valuable in the differential diagnosis of glaucoma and MS.


Assuntos
Pressão Intraocular , Esclerose Múltipla , Fibras Nervosas , Disco Óptico , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Feminino , Masculino , Esclerose Múltipla/diagnóstico , Esclerose Múltipla/complicações , Estudos Prospectivos , Células Ganglionares da Retina/patologia , Fibras Nervosas/patologia , Disco Óptico/patologia , Disco Óptico/diagnóstico por imagem , Pessoa de Meia-Idade , Adulto , Pressão Intraocular/fisiologia , Glaucoma de Ângulo Aberto/diagnóstico , Campos Visuais/fisiologia , Neurite Óptica/diagnóstico
16.
PLoS One ; 19(5): e0302568, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38748752

RESUMO

PURPOSE: We developed a novel transpalpebral self-tonometer called the TapEye tonometer (TET) based on palpation of the upper eyelid. Our goal was to evaluate a method for improving the accuracy of measuring intraocular pressure (IOP) through the eyelid. METHODS: Participants underwent standardized training by technicians and were required to be able to use the TET for study inclusion. Subsequently, a noncontact tonometer and Goldmann applanation tonometer (GAT) were used. All participants were instructed to measure their IOPs using the three tonometers at baseline (visit 1) and at 1 month (visit 2). At visit 2, the corrected IOP value measured by the TET (c-TET) was calculated using the difference between the TET and GAT measurements obtained at visit 1. RESULTS: No significant correlations were found between the TET and GAT measurements at any visit, but the correlation between the c-TET and GAT measurements at visit 2 was significant. The mean difference between the c-TET and GAT measurements was 0.4 ± 3.7 mmHg in the right eye and 0.5 ± 3.4 mmHg in the left eye. CONCLUSIONS: After correcting the IOP based on the difference between the TET and GAT measurements at the initial visit, the corrected IOP value of the TET was correlated with that of the GAT at the second visit. The TET has the potential to address an unmet need by providing a tool for minimally invasive IOP measurements. TRIAL REGISTRATION: Clinical trial registration number: jRCTs032220268.


Assuntos
Pressão Intraocular , Tonometria Ocular , Humanos , Pressão Intraocular/fisiologia , Tonometria Ocular/instrumentação , Tonometria Ocular/métodos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Adulto Jovem
17.
J Refract Surg ; 40(5): e304-e312, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717085

RESUMO

PURPOSE: To compare intraoperative performance and early postoperative outcomes following phacoemulsification with two systems using active fluidics and one using gravity-based fluidics. METHODS: In this prospective randomized trial, 200 eyes were randomized to the traditional and Active Sentry groups (n = 80 eyes each) where the Centurion Vision System was used with traditional or Active Sentry (Alcon Laboratories, Inc) hand-pieces, respectively, or the Infinit group (n = 40 eyes) where the Infiniti Vision System (Alcon Laboratories, Inc) was used. Within the traditional and Active Sentry groups, there were two subgroups with low (30 mm Hg) or high (55 mm Hg) intraocular pressure (IOP) used. Outcome measures compared were: cumulative dissipated energy (CDE), percentage change in central corneal thickness (CCT) at 1 day, 1 week, and 1 month, anterior chamber cells at 1 day and 1 week, rate of rise and fall of IOP following occlusion break, corneal endothelial cell density (ECD), and macular thickness 6 months postoperatively. RESULTS: CDE was significantly lower in group II compared to the traditional group (2.96 ± 1.4 vs 4.14 ± 2.2, P = .001). With 30 mm Hg IOP, the Active Sentry group had significantly less percentage change in CCT at 1 week postoperatively compared to the traditional handpiece group (0.01% vs 0.02%, P = .008). Incidence of anterior chamber cells less than grade 2 on day 1 was significantly higher in the Active Sentry group (82.9% vs 52%, P = .03). Percentage change in ECD was significantly lower in the Active Sentry group (-0.957 vs -0.98%, P = .005). Significantly faster rise of IOP to baseline following occlusion break was seen in the Active Sentry group. CONCLUSIONS: The use of Active Sentry handpiece was associated with lower CDE, less postoperative increase in CCT, fewer anterior chamber cells, and faster rise of IOP following occlusion break. [J Refract Surg. 2024;40(5):e304-e312.].


Assuntos
Pressão Intraocular , Implante de Lente Intraocular , Facoemulsificação , Acuidade Visual , Humanos , Estudos Prospectivos , Pressão Intraocular/fisiologia , Masculino , Feminino , Idoso , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Endotélio Corneano/patologia , Contagem de Células , Período Pós-Operatório , Tomografia de Coerência Óptica , Hidrodinâmica , Câmara Anterior , Período Intraoperatório
18.
J Refract Surg ; 40(5): e344-e352, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717086

RESUMO

PURPOSE: To compare the effects of three common refractive surgeries on corneal biomechanics. METHODS: Two hundred seven patients who had refractive surgery were included in this study, of whom 65 received transepithelial photorefractive keratectomy (tPRK), 73 received femtosecond laser-assisted laser in situ keratomileusis (FSLASIK), and 69 received small incision lenticule extraction (SMILE). Each patient had biomechanical measurements using the Corvis ST (Oculus Optikgeräte GmbH) preoperatively and at 3 and 6 months postoperatively. The measurements included five parameters expected to be associated with corneal biomechanics: deformation amplitude ratio at 2 mm (DAR2), integrated inverse radius (IIR), stiffness parameter at first applanation (SP-A1), highest concavity time (HCT), and the updated stress-strain index (SSIv2). The variations in these parameters postoperatively among the three surgeries, and their relationship with corneal thickness (CCT) and intraocular pressure measured by the Dynamic Contour Tonometer (DCT-IOP) were analyzed. RESULTS: SP-A1 decreased significantly from preoperatively to 3 months postoperatively in all three groups, whereas DAR2 and IIR increased significantly, all indicating stiffness losses. Between 3 and 6 months postoperatively, the results were inconsistent, with DAR2 decreasing (indicating stiffness increases) and IIR increasing (denoting stiffness decreases) in the FS-LASIK and SMILE groups. The decrease in SSIv2 (the only measure of corneal material stiffness) postoperatively was comparatively less pronounced at both 3 and 6 months postoperatively. On the other hand, HCT remained generally stable after all three surgeries. Unlike DAR2, IIR, and SP-A1, the changes postoperatively in stiffness parameters HCT and SSIv2 were independent of the corresponding changes in both DCT-IOP and CCT. CONCLUSIONS: Among the stiffness parameters considered, SSIv2 was not correlated with CCT or DCT-IOP, and holds promise for representing the corneal material stiffness and how it remains largely unaffected by refractive surgeries. Overall, FS-LASIK had the most significant impact on corneal stiffness, followed by SMILE, and finally tPRK. [J Refract Surg. 2024;40(5):e344-e352.].


Assuntos
Córnea , Elasticidade , Pressão Intraocular , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Humanos , Córnea/fisiopatologia , Córnea/cirurgia , Adulto , Feminino , Masculino , Fenômenos Biomecânicos , Lasers de Excimer/uso terapêutico , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Adulto Jovem , Elasticidade/fisiologia , Miopia/cirurgia , Miopia/fisiopatologia , Pressão Intraocular/fisiologia , Ceratectomia Fotorrefrativa/métodos , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Estudos Prospectivos , Cirurgia da Córnea a Laser/métodos , Topografia da Córnea
19.
Nan Fang Yi Ke Da Xue Xue Bao ; 44(4): 660-665, 2024 Apr 20.
Artigo em Chinês | MEDLINE | ID: mdl-38708498

RESUMO

OBJECTIVE: To investigate the effects of different ventilation strategies on intraocular pressure (IOP) and intracranial pressure in patients undergoing spinal surgery in the prone position under general anesthesia. METHODS: Seventy-two patients undergoing prone spinal surgery under general anesthesia between November, 2022 and June, 2023 were equally randomized into two groups to receive routine ventilation (with Vt of 8mL/kg, Fr of 12-15/min, and etCO2 maintained at 35-40 mmHg) or small tidal volume hyperventilation (Vt of 6 mL/kg, Fr of18-20/min, and etCO2 maintained at 30-35 mmHg) during the surgery. IOP of both eyes (measured with a handheld tonometer), optic nerve sheath diameter (ONSD; measured at 3 mm behind the eyeball with bedside real-time ultrasound), circulatory and respiratory parameters of the patients were recorded before anesthesia (T0), immediately after anesthesia induction (T1), immediately after prone positioning (T2), at 2 h during operation (T3), immediately after supine positioning after surgery (T4) and 30 min after the operation (T5). RESULTS: Compared with those at T1, IOP and ONSD in both groups increased significantly at T3 and T4(P < 0.05). IOP was significantly lower in hyperventilation group than in routine ventilation group at T3 and T4(P < 0.05), and ONSD was significantly lower in hyperventilation group at T4(P < 0.05). IOP was positively correlated with the length of operative time (r=0.779, P < 0.001) and inversely with intraoperative etCO2 at T3(r=-0.248, P < 0.001) and T4(r=-0.251, P < 0.001).ONSD was correlated only with operation time (r=0.561, P < 0.05) and not with IOP (r=0.178, P>0.05 at T3; r=0.165, P>0.05 at T4). CONCLUSION: Small tidal volume hyperventilation can relieve the increase of IOP and ONSD during prone spinal surgery under general anesthesia.


Assuntos
Anestesia Geral , Hiperventilação , Pressão Intraocular , Volume de Ventilação Pulmonar , Humanos , Decúbito Ventral , Pressão Intraocular/fisiologia , Anestesia Geral/métodos , Pressão Intracraniana , Coluna Vertebral/cirurgia , Feminino , Masculino , Respiração Artificial/métodos , Hipertensão Intracraniana/cirurgia , Hipertensão Intracraniana/etiologia
20.
Am J Ophthalmol ; 259: 7-14, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38708401

RESUMO

Purpose: To evaluate the diagnostic accuracy of retinal nerve fiber layer thickness (RNFLT) by spectral-domain optical coherence tomography (OCT) in primary open-angle glaucoma (POAG) in eyes of African (AD) and European descent (ED). Design: Comparative diagnostic accuracy analysis by race. Participants: 379 healthy eyes (125 AD and 254 ED) and 442 glaucomatous eyes (226 AD and 216 ED) from the Diagnostic Innovations in Glaucoma Study and the African Descent and Glaucoma Evaluation Study. Methods: Spectralis (Heidelberg Engineering GmbH) and Cirrus (Carl Zeiss Meditec) OCT scans were taken within one year from each other. Main Outcome Measures: Diagnostic accuracy of RNFLT measurements. Results: Diagnostic accuracy for Spectralis-RNFLT was significantly lower in eyes of AD compared to those of ED (area under the receiver operating curve [AUROC]: 0.85 and 0.91, respectively, P=0.04). Results for Cirrus-RNFLT were similar but did not reach statistical significance (AUROC: 0.86 and 0.90 in AD and ED, respectively, P =0.33). Adjustments for age, central corneal thickness, axial length, disc area, visual field mean deviation, and intraocular pressure yielded similar results. Conclusions: OCT-RNFLT has lower diagnostic accuracy in eyes of AD compared to those of ED. This finding was generally robust across two OCT instruments and remained after adjustment for many potential confounders. Further studies are needed to explore the potential sources of this difference.


Assuntos
Glaucoma de Ângulo Aberto , Pressão Intraocular , Fibras Nervosas , Disco Óptico , Curva ROC , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Campos Visuais , População Branca , Humanos , Glaucoma de Ângulo Aberto/etnologia , Glaucoma de Ângulo Aberto/diagnóstico , Tomografia de Coerência Óptica/métodos , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Feminino , Masculino , Pessoa de Meia-Idade , Pressão Intraocular/fisiologia , Campos Visuais/fisiologia , População Branca/etnologia , Reprodutibilidade dos Testes , Idoso , Disco Óptico/patologia , Disco Óptico/diagnóstico por imagem , Doenças do Nervo Óptico/diagnóstico , Doenças do Nervo Óptico/etnologia , Negro ou Afro-Americano/etnologia , Área Sob a Curva , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA