RESUMO
As most HIV rapid tests (HRT) detect only HIV-1/2 antibodies, their performance during primary HIV infection is poor. Determine HIV Early detect (Abbott) (Determine) is the only HRT with an HIV-1 p24-antigen detection, but the impact of this addition in shortening the diagnostic window remains unclear. A total of 183 HIV-1 primary infection samples were tested using the HRTs Determine and ONE STEP anti-HIV (1&2) Test (InTec Products) (One-Step). The pre-seroconversion subgroup was defined as p24-antigen positivity without Western blot nor Liaison XL (fouth generation enzyme immunoassay with distinct signal for p24-antigen and HIV-1 antibody) HIV-1 antibodies. Global sensitivity (95% CI) was 95% (91-97) for Determine versus 80% (74%-85%) for One-Step (difference p = 1.38e-06). Pre-seroconversion subgroup sensitivity was lower, at 71.9 (54.6%-84.4%) for Determine and 9.7% (3.3%-24.9%) for One-Step. Among the 45 samples with an HIV-1 infection date, no HRT was reactive up to 2 weeks. Between 2 and 3 weeks, Determine sensitivity was 78% (45%-95%) versus 56% (27%-81%) for One-Step. From 3 weeks to 1 month Determine sensitivity was 90% (62%-98%) and One-Step 45% (21%-72%). The last negative sample occurred at 3 weeks for Determine versus 70-90 days for One-Step. HRT with p24-antigen detection significantly shortens the diagnostic window from approximatively 3 months to 1 month. HRTs should be used with caution in the first month after HIV infection.
Assuntos
Proteína do Núcleo p24 do HIV , Infecções por HIV , HIV-1 , Sensibilidade e Especificidade , Humanos , Infecções por HIV/diagnóstico , HIV-1/imunologia , HIV-1/isolamento & purificação , Proteína do Núcleo p24 do HIV/sangue , Proteína do Núcleo p24 do HIV/imunologia , Anticorpos Anti-HIV/sangue , Feminino , Masculino , Adulto , Programas de Rastreamento/métodos , Teste de HIV/métodos , Kit de Reagentes para Diagnóstico/normas , Pessoa de Meia-Idade , Fatores de TempoRESUMO
Fourth-generation HIV immunoassays have been developed to reduce the window period of detection during seroconversion period, allowing for the detection of early and established infections. The aim of this work was to evaluate a newly developed assay, Access HIV Ag/Ab combo on the novel high throughput DxI 9000 Access Immunoassay Analyzer (Beckman Coulter, Inc.). The assay allows for simultaneous qualitative detection and differentiation of HIV-1 p24 antigen and HIV-1/2 antibodies. Assay performance was compared to two gold standard assays, the Abbott Architect HIV Ag/Ab Combo and Roche Elecsys HIV Duo, and assessed in a multicenter study, using a wide panel of samples (n > 9000, clinical samples and viral lysates) representative of genetic diversity for both antibodies and antigens, early phases of infection, negative, and cross-reacting samples. The clinical sensitivity was 100 % for clinical samples as well as for viral lysates. Data on viral lysates and early detection on seroconversion panels showed a better result with the Access assay. Analytical sensitivity showed a limit of p24 detection determined around 0.2 IU/mL. The overall specificity was 99.91 %, and no interference was found using the potentially cross-reactive samples. In conclusion, the Access HIV Ag/Ab combo assay demonstrated its ability for accurate diagnosis of chronic as well as primary HIV infections on the DxI 9000 Analyzer, despite the high level of genetic diversity of these viruses.
Assuntos
Anticorpos Anti-HIV , Proteína do Núcleo p24 do HIV , Infecções por HIV , HIV-1 , Sensibilidade e Especificidade , Humanos , Infecções por HIV/diagnóstico , Anticorpos Anti-HIV/sangue , Imunoensaio/métodos , HIV-1/imunologia , HIV-1/genética , Proteína do Núcleo p24 do HIV/sangue , Proteína do Núcleo p24 do HIV/imunologia , Antígenos HIV/sangue , Antígenos HIV/imunologia , HIV-2/imunologia , HIV-2/genética , Kit de Reagentes para Diagnóstico/normasRESUMO
Although previous studies have suggested that subtype B HIV-1 proviruses in the brain are associated with physiological changes and immune activation accompanied with microgliosis and astrogliosis, and indicated that both HIV-1 subtype variation and geographical location might influence the neuropathogenicity of HIV-1 in the brain. The natural course of neuropathogenesis of the most widespread subtype C HIV-1 has not been adequately investigated, especially for people living with HIV (PLWH) in sub-Saharan Africa. To characterize the natural neuropathology of subtype C HIV-1, postmortem frontal lobe and basal ganglia tissues were collected from nine ART-naïve individuals who died of late-stage AIDS with subtype C HIV-1 infection, and eight uninfected deceased individuals as controls. Histological staining was performed on all brain tissues to assess brain pathologies. Immunohistochemistry (IHC) against CD4, p24, Iba-1, GFAP, and CD8 in all brain tissues was conducted to evaluate potential viral production and immune activation. Histological results showed mild perivascular cuffs of lymphocytes only in a minority of the infected individuals. Viral capsid p24 protein was only detected in circulating immune cells of one infected individual, suggesting a lack of productive HIV-1 infection of the brain even at the late-stage of AIDS. Notably, similar levels of Iba-1 or GFAP between HIV + and HIV- brain tissues indicated a lack of microgliosis and astrogliosis, respectively. Similar levels of CD8 + cytotoxic T lymphocyte (CTL) infiltration between HIV + and HIV- brain tissues indicated CTL were not likely to be involved within subtype C HIV-1 infected participants of this cohort. Results from this subtype C HIV-1 study suggest that there is a lack of productive infection and limited neuropathogenesis by subtype C HIV-1 even at late-stage disease, which is in contrast to what was reported for subtype B HIV-1 by other investigators.
Assuntos
Proteína Glial Fibrilar Ácida , HIV-1 , Humanos , HIV-1/imunologia , HIV-1/patogenicidade , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , África Subsaariana , Proteína Glial Fibrilar Ácida/imunologia , Infecções por HIV/imunologia , Infecções por HIV/virologia , Infecções por HIV/patologia , Gânglios da Base/imunologia , Gânglios da Base/patologia , Gânglios da Base/virologia , Proteínas de Ligação ao Cálcio/imunologia , Proteínas de Ligação ao Cálcio/genética , Lobo Frontal/imunologia , Lobo Frontal/patologia , Lobo Frontal/virologia , Proteína do Núcleo p24 do HIV/imunologia , Complexo AIDS Demência/imunologia , Complexo AIDS Demência/patologia , Complexo AIDS Demência/virologia , Antígenos CD4/imunologia , Linfócitos T CD8-Positivos/imunologia , Gliose/imunologia , Gliose/patologia , Gliose/virologia , Astrócitos/imunologia , Astrócitos/patologia , Astrócitos/virologia , Encéfalo/patologia , Encéfalo/imunologia , Encéfalo/virologia , Proteínas dos MicrofilamentosRESUMO
Assays to study HIV persistence are crucial to evaluate therapeutic strategies aimed toward an HIV cure. Several assays have been developed to date that rely on the measurement of nucleic acids. In recent years, the advancement of ultrasensitive technologies for the detection of proteins has improved our understanding of the role of translation-competent reservoirs in HIV persistence. In this chapter, we describe the development of an ultrasensitive p24 ELISA that uses planar array technology. This assay allows for the detection of HIV-1 p24 in the low fg/ml range in different biological matrixes, including cell lysates. This assay can be used to investigate the efficacy of latency reversing agents to reactivate HIV or to evaluate the persistence of translation-competent reservoirs in people living with HIV (PWH) in cells or diverse biological fluids.
Assuntos
Ensaio de Imunoadsorção Enzimática , Proteína do Núcleo p24 do HIV , Infecções por HIV , HIV-1 , Humanos , Ensaio de Imunoadsorção Enzimática/métodos , Proteína do Núcleo p24 do HIV/metabolismo , Proteína do Núcleo p24 do HIV/análise , Infecções por HIV/virologia , Latência ViralRESUMO
Recent evidence has shown that uncoating and reverse transcription precede nuclear import. These recent breakthroughs have been made possible through the development of innovative biochemical and imaging techniques. This method outlines the biochemical assay used for detecting the presence of the HIV-1 core in the nuclear compartment. In this procedure, human cells are infected with HIV-1NL4-3, with or without the inclusion of PF74, a small molecule that inhibits core entry into the nuclear compartment. Subsequently, cells are separated into cytosolic and nuclear fractions. To assess whether the capsid protein has reached the nuclear compartment, cytosolic and nuclear fractions are subjected to Western blot analysis, utilizing antibodies specific to the HIV-1 capsid protein p24. To validate the true origin of these fractions, Western blot analysis employing antibodies against cytosolic and nuclear markers are also performed. In summary, this assay provides a reliable and efficient means to detect the presence of the HIV-1 capsid protein in the nucleus during infection under various conditions.
Assuntos
Capsídeo , Infecções por HIV , HIV-1 , Humanos , Western Blotting/métodos , Capsídeo/metabolismo , Proteínas do Capsídeo/metabolismo , Linhagem Celular , Núcleo Celular/metabolismo , Proteína do Núcleo p24 do HIV/metabolismo , Proteína do Núcleo p24 do HIV/análise , Infecções por HIV/virologia , Infecções por HIV/metabolismo , Fenilalanina/metabolismo , Fenilalanina/análogos & derivadosRESUMO
Diagnosing of human immunodeficiency virus (HIV) types 1 and 2 requires a screening with a highly sensitive and specific enzyme immunoassay and a low detection limit for the HIV-1 p24 antigen to minimize the diagnostic window. The objective of the study was to determine the sensitivity, specificity, and p24 limit of detection of the Access HIV combo V2 assay. Retrospective part of sensitivity: 452 HIV-1 positive samples from 403 chronic (9 different HIV-1 group M subtypes, 22 different HIV-1 group M CRFs, and 3 HIV-1 group O), 49 primary HIV-1 infections, 103 HIV-2 positive samples assessed at Pitié-Salpêtrière Hospital, 600 untyped HIV-1, 10 subtype-D, and 159 untyped HIV-2 samples assessed in Bio-Rad Laboratories. Prospective part of clinical specificity: all consecutive samples in two blood donor facilities and Pitié-Salpêtrière (6,570 patients) tested with Access HIV combo V2 and respectively Prism HIV O Plus (Abbott) or Architect HIV Ag/Ab Combo (Abbott) for Ag/Ab screening, and Procleix Ultrio (Gen Probe) for HIV RNA screening. Limit of detection for p24 antigen was assessed on recombinant virus-like particles (10 HIV-1 group M subtypes/CRFs, HIV-1 group O). Sensitivity [95% confidence interval (CI)] of Access HIV combo V2 was 100% (99.63-100) for HIV-1 chronic infection, 100% (98.55-100) for HIV-2 chronic infection, and 100% (93.00-100) for HIV-1 primary infection. Specificity (95% CI) was 99.98 (99.91-100). Limit of detection for p24 antigen was around 0.43 IU/mL [interquartile range (0.38-0.56)], and consistent across the 11 analyzed subtypes/CRFs. Hence, with both high sensitivity and specificity, Access HIV combo V2 is a suitable screening assay for HIV-1/2 infection. IMPORTANCE: Bio-Rad is one of the leading human immunodeficiency virus (HIV) screening test manufacturers. This laboratory released in 2021 their new version of the Access combo HIV test. However, to date, there have been no studies regarding its performance, especially its limit of detection of the diverse p24 antigen. We present the sensitivity (chronic and primary HIV-1 infection and HIV-2 chronic infection), specificity (blood donors and hospitalized patients), and raw data for the p24/seroconversion panels the manufacturer gave to the European agencies.
Assuntos
Proteína do Núcleo p24 do HIV , Infecções por HIV , HIV-1 , HIV-2 , Programas de Rastreamento , Sensibilidade e Especificidade , Humanos , Infecções por HIV/diagnóstico , HIV-1/genética , HIV-1/classificação , HIV-1/isolamento & purificação , HIV-1/imunologia , Estudos Retrospectivos , Proteína do Núcleo p24 do HIV/sangue , HIV-2/imunologia , HIV-2/classificação , HIV-2/genética , HIV-2/isolamento & purificação , Programas de Rastreamento/métodos , Estudos Prospectivos , Teste de HIV/métodos , MasculinoRESUMO
BACKGROUND: Mozambique is a high-prevalence country for HIV and early detection of new HIV infections is crucial for control of the epidemic. We aimed to evaluate the accuracy of the 4th-generation rapid diagnostic test (RDT) AlereTM HIV Combo in detecting acute and seroconverted HIV-infection, among sexually-active women attending three clinical health centers in Maputo, Mozambique. METHODS: Women aged 14-55 years (n = 920) seeking care at the Mavalane Health Area, Maputo (February 2018-January 2019) were included, and blood specimens sampled. Sociodemographic and sexual behavior data were collected. Point-of-care HIV testing was performed using Alere DetermineTM HIV-1/2 and Uni-GoldTM HIV-1/2. All samples were also tested using Enzygnost® HIV Integral 4 and Innotest® HIV Antigen mAb in laboratory. The 4th-generation RDT AlereTM HIV Combo was evaluated on serum samples in the laboratory. Finally, Innotest® HIV Antigen mAb, Enzygnost® HIV Integral 4 (Ag/Ab), and HIV RNA quantification acted as gold standard assays in the evaluation of AlereTM HIV Combo test for HIV antigen detection (in clinical samples and in three HIV-1 seroconversion panels). RESULTS: The antibody component of the 4th generation AlereTM HIV Combo RDT demonstrated a sensitivity and specificity of 100% examining clinical samples. However, the test did not detect HIV p24 antigen in any clinical samples, while Innotest® HIV Antigen mAb, verified by Enzygnost® HIV Integral 4 (Ag/Ab) and/or HIV RNA quantification, detected HIV antigen in six clinical samples. Furthermore, the AlereTM HIV Combo RDT had a low sensitivity in the detection of HIV p24 antigen in seroconversion panels. The HIV prevalence among the examined women was 17.8%. CONCLUSIONS: The 4th-generation RDT AlereTM HIV Combo showed similar sensitivity to the 3rd-generation RDTs to detect seroconverted HIV-infections. However, the sensitivity for detection of HIV p24 antigen and diagnosing acute HIV infections, before seroconversion, was low. There is an urgent need to develop and evaluate simple and affordable POC tests with high sensitivity and specificity for diagnosing individuals with acute HIV infection in resource-limited settings with high HIV prevalence.
Assuntos
Infecções por HIV , Soropositividade para HIV , HIV-1 , Feminino , Humanos , Infecções por HIV/diagnóstico , Infecções por HIV/epidemiologia , Anticorpos Anti-HIV , Proteína do Núcleo p24 do HIV , Testes Imediatos , Antígenos HIV , Sensibilidade e Especificidade , HIV-1/genética , RNA , HIV-2RESUMO
HIV is an ongoing global epidemic with estimates of more than a million new infections occurring annually. To combat viral spread, continuous innovations in areas including testing and treatment are necessary. In the United States, the Centers for Disease Control and Prevention recommend that laboratories follow an HIV testing algorithm that first uses a US Food and Drug Administration approved immunoassay to detect antibodies to HIV-1 or HIV-2 as well as HIV-1 p24 antigen in serum or plasma samples. An initially reactive specimen is tested by a supplemental assay for confirmation and to differentiate antibodies to HIV-1 or HIV-2. There are few Food and Drug Administration (FDA)-approved supplemental differentiation tests currently available. A multicenter investigation was conducted to determine the clinical performance for two independent versions of the Avioq VioOne HIV Profile Supplemental Assay (Avioq, Inc., Research Triangle Park, NC). The performance of both assay versions compared favorably with the performance parameters for the Geenius HIV 1/2 Supplemental Assay as published in that assay package insert (Bio-Rad Laboratories, Hercules, CA), the current gold standard for HIV supplemental testing. When comparing the two VioOne assays, version 2 (lacking HIV-2 p27 antibody detection) demonstrated improved reproducibility, specificity, and sensitivity as compared to its predecessor. IMPORTANCE We evaluated the reproducibility, sensitivity, and specificity data for two versions of the VioOne HIV Profile Supplemental Assay and compared these results back to similar results for the Geenius HIV 1/2 Supplemental Assay that are publicly available. Our study concluded that the VioOne HIV Profile Supplemental Assay compared favorably with the Geenius HIV 1/2 Supplemental Assay, thus providing an additional option for clinical laboratories to improve and expand their HIV testing capabilities.
Assuntos
Infecções por HIV , Soropositividade para HIV , HIV-1 , Humanos , Estados Unidos , Reprodutibilidade dos Testes , Anticorpos Anti-HIV , Algoritmos , HIV-2 , Proteína do Núcleo p24 do HIV , Sensibilidade e EspecificidadeRESUMO
The development of latency reversing agents that potently reactivate HIV without inducing global T cell activation would benefit the field of HIV reservoir research and could pave the way to a functional cure. Here, we explore the reactivation capacity of a lipid nanoparticle containing Tat mRNA (Tat-LNP) in CD4 T cells from people living with HIV undergoing antiretroviral therapy (ART). When combined with panobinostat, Tat-LNP induces latency reversal in a significantly higher proportion of latently infected cells compared to PMA/ionomycin (≈ 4-fold higher). We demonstrate that Tat-LNP does not alter the transcriptome of CD4 T cells, enabling the characterization of latently infected cells in their near-native state. Upon latency reversal, we identify transcriptomic differences between infected cells carrying an inducible provirus and non-infected cells (e.g. LINC02964, GZMA, CCL5). We confirm the transcriptomic differences at the protein level and provide evidence that the long non-coding RNA LINC02964 plays a role in active HIV infection. Furthermore, p24+ cells exhibit heightened PI3K/Akt signaling, along with downregulation of protein translation, suggesting that HIV-infected cells display distinct signatures facilitating their long-term persistence. Tat-LNP represents a valuable research tool for in vitro reservoir studies as it greatly facilitates the in-depth characterization of HIV reservoir cells' transcriptome and proteome profiles.
Assuntos
Produtos do Gene tat , HIV-1 , Nanopartículas , RNA Viral , Latência Viral , Latência Viral/efeitos dos fármacos , Latência Viral/genética , Produtos do Gene tat/genética , Produtos do Gene tat/metabolismo , RNA Viral/administração & dosagem , RNA Viral/genética , RNA Viral/metabolismo , Nanopartículas/administração & dosagem , Nanopartículas/química , Infecções por HIV/tratamento farmacológico , Infecções por HIV/genética , Infecções por HIV/virologia , Panobinostat/farmacologia , Terapia Antirretroviral de Alta Atividade , Linfócitos T CD4-Positivos/efeitos dos fármacos , Linfócitos T CD4-Positivos/virologia , Antígenos CD4/genética , Antígenos CD4/metabolismo , HIV-1/efeitos dos fármacos , HIV-1/genética , Provírus/efeitos dos fármacos , Provírus/genética , Análise da Expressão Gênica de Célula Única , Proteína do Núcleo p24 do HIV/genética , Proteína do Núcleo p24 do HIV/metabolismo , RNA Longo não Codificante/metabolismo , Células Cultivadas , Humanos , Ionomicina/farmacologiaRESUMO
BACKGROUND: The capsid p24 (CA-p24) antigen is a component of the viral capsid of human immunodeficiency virus (HIV) that has been commonly used for clinical diagnosis and monitoring of HIV infections in Enzyme-linked Immunosorbent Assays (ELISAs). Commercial CA-p24 ELISAs are widely used in research settings, but these kits are costly and have limited breadth for detecting diverse HIV isolates. METHODS: Commercial CA-p24 antibodies were used as capture and detection antibodies. Specific CA-p24 ELISAs were established with these antibodies and tested for the detection of HIV-1 isolates with the aim of developing in-house protocols to recognize HIV-1 infections in vitro for research purposes. RESULTS: Here we present four protocols for in-house ELISAs to detect HIV CA-p24 using commercial antibodies. The assays were able to detect the CA-p24 antigen of different HIV-1 isolates tested. Comparison between the protocols showed that these in-house ELISAs exhibit high specificity, sensitivity, and reproducibility for CA-p24 quantitation but their reactivity varied per HIV-1 isolate and subtype. CONCLUSIONS: These optimized ELISA protocols represent valuable tools to investigate HIV-1 infections in research facilities at a lower price than commercial CA-p24 kits.
Assuntos
Infecções por HIV , HIV-1 , Humanos , Capsídeo/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ensaio de Imunoadsorção Enzimática/métodos , Proteína do Núcleo p24 do HIV/análise , Proteínas do CapsídeoRESUMO
The advent of combined antiretroviral therapy (cART) has been instrumental in controlling HIV-1 replication and transmission and decreasing associated morbidity and mortality. However, cART alone is not able to cure HIV-1 due to the presence of long-lived, latently infected immune cells, which re-seed plasma viremia when cART is interrupted. Assessment of HIV-cure strategies using ex vivo culture methods for further understanding of the diversity of reactivated HIV, viral outgrowth, and replication dynamics are enhanced using ultrasensitive digital ELISA based on single-molecule array (Simoa) technology to increase the sensitivity of endpoint detection. In viral outgrowth assays (VOA), exponential HIV-1 outgrowth has been shown to be dependent upon initial virus burst size surpassing a critical growth threshold of 5100 HIV-1 RNA copies. Here, we show an association between ultrasensitive HIV-1 Gag p24 concentrations and HIV-1 RNA copy number that characterize viral dynamics below the exponential replication threshold. Single-genome sequencing (SGS) revealed the presence of multiple identical HIV-1 sequences, indicative of low-level replication occurring below the threshold of exponential outgrowth early during a VOA. However, SGS further revealed diverse related HIV variants detectable by ultrasensitive methods that failed to establish exponential outgrowth. Overall, our data suggest that viral outgrowth occurring below the threshold necessary for establishing exponential growth in culture does not preclude replication competence of reactivated HIV, and ultrasensitive detection of HIV-1 p24 may provide a method to detect previously unquantifiable variants. These data strongly support the use of the Simoa platform in a multi-prong approach to measuring latent viral burden and efficacy of therapeutic interventions aimed at an HIV-1 cure.
Assuntos
Infecções por HIV , Soropositividade para HIV , HIV-1 , Humanos , HIV-1/genética , Cinética , Ensaio de Imunoadsorção Enzimática , Proteína do Núcleo p24 do HIV , RNA , Carga Viral , Linfócitos T CD4-Positivos , Latência ViralRESUMO
Despite major advances in HIV testing, ultrasensitive detection of early infection remains challenging, especially for the viral capsid protein p24, which is an early virological biomarker of HIV-1 infection. Here, To improve p24 detection in patients missed by immunological tests that dominate the diagnostics market, we show a click chemistry amplified nanopore (CAN) assay for ultrasensitive quantitative detection. This strategy achieves a 20.8 fM (0.5 pg/ml) limit of detection for HIV-1 p24 antigen in human serum, demonstrating 20~100-fold higher analytical sensitivity than nanocluster-based immunoassays and clinically used enzyme-linked immunosorbent assay, respectively. Clinical validation of the CAN assay in a pilot cohort shows p24 quantification at ultra-low concentration range and correlation with CD4 count and viral load. We believe that this strategy can improve the utility of p24 antigen in detecting early infection and monitoring HIV progression and treatment efficacy, and also can be readily modified to detect other infectious diseases.
Assuntos
Infecções por HIV , HIV-1 , Nanoporos , Humanos , Química Click , Proteína do Núcleo p24 do HIV , Teste de HIV , Ensaio de Imunoadsorção Enzimática , Sensibilidade e EspecificidadeRESUMO
Since its discovery in the 1990s, the DNA vaccine has been of great interest because of its ability to elicit both humoral and cellular immune responses while showing relative advantages regarding producibility, stability and storage. However, when applied to human subjects, inadequate immunogenicity remains as the greatest challenge for the practical use of DNA vaccines. In this study, we generated a DNA vaccine Δ42PD1-P24 encoding a fusion protein comprised of the HIV-1 Gag p24 antigen and the extracellular domain of murine Δ42PD1, a novel endogenous Toll-like receptor 4 (TLR4) agonist. Using a mouse model, we found that Δ42PD1-P24 DNA vaccine elicited a higher antibody response and an increased number of IFN-γ-producing CD4 and CD8 T cells. Moreover, mice with Δ42PD1-P24 DNA vaccination were protected from a subcutaneous challenge with murine mesothelioma cells expressing the HIV-1 p24 antigen. Importantly, the Δ42PD1-mediated enhancement of immune responses was not observed in TLR4 knockout mice. Collectively, these data demonstrate that the immunogenicity and efficacy of DNA vaccines could be improved by the fusion of the extracellular domain of Δ42PD1 to target the immunogen to dendritic cells.
Assuntos
Vacinas contra a AIDS , Infecções por HIV , HIV-1 , Vacinas de DNA , Animais , Camundongos , Humanos , HIV-1/genética , Receptor 4 Toll-Like , Linfócitos T CD8-Positivos , Imunidade Celular , Proteína do Núcleo p24 do HIVRESUMO
Multipurpose prevention technologies (MPTs), which prevent sexually transmitted infection(s) and unintended pregnancy, are highly desirable to women. In this randomized, placebo-controlled, phase I study, women used a placebo or tenofovir (TFV) and levonorgestrel (LNG) intravaginal ring (IVR), either continuously or cyclically (three, 28-day cycles with a 3 day interruption in between each cycle), for 90 days. Sixty-eight women were screened; 47 were randomized to 4 arms: TFV/LNG or placebo IVRs used continuously or cyclically (4:4:1:1). Safety was assessed by adverse events and changes from baseline in mucosal histology and immune mediators. TFV concentrations were evaluated in multiple compartments. LNG concentration was determined in serum. Modeled TFV pharmacodynamic antiviral activity was evaluated in vaginal and rectal fluids and cervicovaginal tissue ex vivo. LNG pharmacodynamics was assessed with cervical mucus quality and anovulation. All IVRs were safe with no serious adverse events nor significant changes in genital tract histology, immune cell density or secreted soluble proteins from baseline. Median vaginal fluid TFV concentrations were >500 ng/mg throughout 90d. TFV-diphosphate tissue concentrations exceeded 1,000 fmol/mg within 72hrs of IVR insertion. Mean serum LNG concentrations exceeded 200 pg/mL within 2h of TFV/LNG use, decreasing quickly after IVR removal. Vaginal fluid of women using TFV-containing IVRs had significantly greater inhibitory activity (87-98% versus 10% at baseline; p<0.01) against HIV replication in vitro. There was a >10-fold reduction in HIV p24 antigen production from ectocervical tissues after TFV/LNG exposure. TFV/LNG IVR users had significantly higher rates of anovulation, lower Insler scores and poorer/abnormal cervical mucus sperm penetration. Most TFV/LNG IVR users reported no change in menstrual cycles or fewer days of and/or lighter bleeding. All IVRs were safe. Active rings delivered high TFV concentrations locally. LNG caused changes in cervical mucus, sperm penetration, and ovulation compatible with contraceptive efficacy. Trial registration: ClinicalTrials.gov #NCT03279120.
Assuntos
Anovulação , Anticoncepcionais , Dispositivos Anticoncepcionais Femininos , Levanogestrel , Tenofovir , Anovulação/induzido quimicamente , Antivirais , Anticoncepcionais/uso terapêutico , Difosfatos , Feminino , Proteína do Núcleo p24 do HIV , Infecções por HIV , Humanos , Levanogestrel/uso terapêutico , Masculino , Sêmen , Tenofovir/uso terapêuticoRESUMO
Anti-retroviral therapy (ART) generally suppresses HIV replication to undetectable levels in peripheral blood, but immune activation associated with increased morbidity and mortality is sustained during ART, and infection rebounds when treatment is interrupted. To identify drivers of immune activation and potential sources of viral rebound, we modified RNAscope in situ hybridization to visualize HIV-producing cells as a standard against which to compare the following assays of potential sources of immune activation and virus rebound following treatment interruption: (i) envelope detection by induced transcription-based sequencing (EDITS) assay; (ii) HIV-Flow; (iii) Flow-FISH assays that can scan tissues and cell suspensions to detect rare cells expressing env mRNA, gag mRNA/Gag protein and p24; and (iv) an ultrasensitive immunoassay that detects p24 in cell/tissue lysates at subfemtomolar levels. We show that the sensitivities of these assays are sufficient to detect one rare HIV-producing/env mRNA+/p24+ cell in one million uninfected cells. These high-throughput technologies provide contemporary tools to detect and characterize rare cells producing virus and viral antigens as potential sources of immune activation and viral rebound. IMPORTANCE Anti-retroviral therapy (ART) has greatly improved the quality and length of life for people living with HIV, but immune activation does not normalize during ART, and persistent immune activation has been linked to increased morbidity and mortality. We report a comparison of assays of two potential sources of immune activation during ART: rare cells producing HIV and the virus' major viral protein, p24, benchmarked on a cell model of active and latent infections and a method to visualize HIV-producing cells. We show that assays of HIV envelope mRNA (EDITS assay), gag mRNA, and p24 (Flow-FISH, HIV-Flow. and ultrasensitive p24 immunoassay) detect HIV-producing cells and p24 at sensitivities of one infected cell in a million uninfected cells, thereby providing validated tools to explore sources of immune activation during ART in the lymphoid and other tissue reservoirs.
Assuntos
Infecções por HIV , HIV-1 , RNA Viral , Tropismo Viral , Ativação Viral , Fármacos Anti-HIV/administração & dosagem , Fármacos Anti-HIV/uso terapêutico , Antígenos Virais/análise , Antígenos Virais/genética , Antígenos Virais/metabolismo , Linfócitos T CD4-Positivos , Proteína do Núcleo p24 do HIV/genética , Infecções por HIV/imunologia , Infecções por HIV/virologia , HIV-1/genética , HIV-1/crescimento & desenvolvimento , HIV-1/imunologia , Humanos , Imunoensaio , Hibridização in Situ Fluorescente , RNA Mensageiro/análise , RNA Viral/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Produtos do Gene env do Vírus da Imunodeficiência Humana/genéticaRESUMO
Background: HIV/AIDS continues to be a serious health concern of morbidity and mortality globally, and novel HIV testing is still an important component of diagnosing HIV earlier and reducing the spread of HIV. The Elecsys® HIV Duo assay is a 4th generation assay that can detect both HIV-1 p24 antigen (Ag) and HIV-1/2 antibody (Ab) in parallel and show the subresults for the Ab and Ab units. Objectives: To evaluate the clinical performance of the Elecsys® HIV Duo assay on the new cobas E 801 analyzer using a large number of clinical samples from a population in southwest China. Methods: We collected testing results and information from all patients in a large general hospital. All eligible clinical specimens were first analyzed using the Elecsys® HIV Duo assay. The test results are given either as reactive or nonreactive as well as in the form of a cutoff index (COI). All initially reactive specimens were retested in duplicate with a 3rd-generation kit. Supplementary tests were divided into Ab confirmation tests and HIV-1 nucleic acid tests. GraphPad Prism and Python were used for plotting, and SPSS 21.0 software was used for statistical analysis. Results: A total of 186391 specimens were received, and 436 patients were confirmed to be positive for HIV. Among the 86 cases with contact history available, there were more males than females, and heterosexual transmission was the most common route of HIV infection. The Elecsys® HIV Duo assay displayed 99.94%, 99.93% and 99.98% specificity for inpatient, outpatient and physical examination patients, respectively. The median COI ratios of the false-positive group were significantly lower than those of the true-positive group. Conclusions: The Elecsys® HIV Duo test (Cobase801 analyzer) differentiates the detection of HIV-1 p24 Ag and HIV-1/2 Ab with high specificity and facilitates the diagnosis of patients with early HIV infection. Therefore, the Elecsys®HIV Duo test is used for differentiation of antigen and antibody reactivity, making it suitable for routine clinical diagnosis.
Assuntos
Infecções por HIV , HIV-1 , Feminino , Proteína do Núcleo p24 do HIV , Infecções por HIV/diagnóstico , Humanos , Imunoensaio/métodos , Masculino , Sensibilidade e EspecificidadeRESUMO
Semen is a known vector for both human immunodeficiency virus (HIV) infection and transmission. However, the distribution and characteristics of HIV-infected cells in semen remain unclear. Investigating the possibility of transmission through the spermatozoon in semen is of great clinical significance to improve the strategies for exposure prevention and assisted reproduction for HIV-infected partners. Twenty-six HIV-infected patients, including twelve treatment-naïve (TN) patients and fourteen antiretroviral treated (ART) patients, were enrolled in this study. HIV p24 protein in spermatozoa was detected using imaging flow cytometry and immunohistochemistry, and HIV RNA was identified using next-generation RNAscope in situ hybridization. Additionally, we described the rates of HIV-positive spermatozoon and CD4+ T lymphocytes in semen, and found that p24+ spermatozoon were mainly CD4 negative regardless of whether the patients received ART. Of note, p24-positive cells in semen are predominantly spermatozoa, and we confirmed that motile spermatozoa carried HIV into peripheral blood mononuclear cells of healthy men in vitro. Our findings provide evidence regarding the risk of HIV-infected spermatozoa.
Assuntos
Infecções por HIV , Leucócitos Mononucleares , Proteína do Núcleo p24 do HIV/uso terapêutico , Humanos , Masculino , EspermatozoidesRESUMO
New strategies to increase the immune response to HIV-1 vaccine using immunological adjuvants such as Toll-like receptor agonists are needed. In this study, HIV-1 p24-Nef and conjugated form of the vaccine candidate to type-A flagellin (FLA) were injected in the BALB/c mice in different routes. Two weeks after the last immunization, lymphocyte proliferation was measured by the BrdU method. The IL-4 and IFN-γ levels, as well as the total IgG antibody and its isotypes titer, were evaluated by the enzyme-linked immunosorbent assay method. The IFN-γ ELISPOT was also performed. Our data showed that the HIV-1 p24-Nef alone and conjugated to type-A flagellin (FLA) significantly increased lymphocyte proliferation responses as well as higher levels of cytokines and IFN-γ producing lymphocytes and the level of humoral immune responses compared with the control groups. The cell-mediated immune responses through the subcutaneous route and humoral immune responses through the intramuscular route were significantly higher in the conjugated form than in the mere vaccine candidate. In conclusion, when the FLA as an adjuvant is constructed in the HIV-1 vaccine candidate, it could effectively improve both humoral and cellular immune responses. Furthermore, modification in the vaccine formulation could change the optimal route of vaccine inoculation.
Assuntos
Vacinas contra a AIDS , HIV-1 , Adjuvantes Imunológicos , Animais , Flagelina , Proteína do Núcleo p24 do HIV , Imunização , Camundongos , Camundongos Endogâmicos BALB C , Pseudomonas aeruginosaRESUMO
While combination antiretroviral therapy maintains undetectable viremia in people living with HIV (PLWH), a lifelong treatment is necessary to prevent viremic rebound after therapy cessation. This rebound seemed mainly caused by long-lived HIV-1 latently infected cells reverting to a viral productive status. Reversing latency and elimination of these cells by the so-called shock-and-kill strategy is one of the main investigated leads to achieve an HIV-1 cure. Small molecules referred to as latency reversal agents (LRAs) proved to efficiently reactivate latent CD4+ T cells. However, the LRA impact on de novo infection or HIV-1 production in productively infected macrophages remains elusive. Nontoxic doses of bryostatin-1, JQ1, and romidepsin were investigated in human monocyte-derived macrophages (MDMs). Treatment with bryostatin-1 or romidepsin resulted in a downregulation of CD4 and CCR5 receptors, respectively, accompanied by a reduction of R5 tropic virus infection. HIV-1 replication was mainly regulated by receptor modulation for bryostatin-1, while romidepsin effects rely on upregulation of SAMHD1 activity. LRA stimulation of chronically infected cells did not enhance HIV-1 production or gene expression. Surprisingly, bryostatin-1 caused a major decrease in viral production. This effect was not viral strain specific but appears to occur only in myeloid cells. Bryostatin-1 treatment of infected MDMs led to decreased amounts of capsid and matrix mature proteins with little to no modulation of precursors. Our observations revealed that bryostatin-1-treated myeloid and CD4+ T cells respond differently upon HIV-1 infection. Therefore, additional studies are warranted to more fully assess the efficiency of HIV-1 eradicating strategies. IMPORTANCE HIV-1 persists in a cellular latent form despite therapy that quickly propagates infection upon treatment interruption. Reversing latency would contribute to eradicate these cells, closing the gap to a cure. Macrophages are an acknowledged HIV-1 reservoir during therapy and are suspected to harbor latency establishment in vivo. However, the impact of latency reversal agents (LRAs) on HIV-1 infection and viral production in human macrophages is poorly known but nonetheless crucial to probe the safety of this strategy. In this in vitro study, we discovered encouraging antireplicative features of distinct LRAs in human macrophages. We also described a new viral production inhibition mechanism by protein kinase C agonists that is specific to myeloid cells. This study provides new insights into HIV-1 propagation restriction potentials by LRAs in human macrophages and underline the importance of assessing latency reversal strategy on all HIV-1-targeted cells.
Assuntos
Fármacos Anti-HIV/farmacologia , Briostatinas/farmacologia , HIV-1/efeitos dos fármacos , Macrófagos/efeitos dos fármacos , Antígenos CD4/metabolismo , Linfócitos T CD4-Positivos/efeitos dos fármacos , Linfócitos T CD4-Positivos/virologia , Depsipeptídeos/farmacologia , Diterpenos/farmacologia , Proteína do Núcleo p24 do HIV/metabolismo , Humanos , Macrófagos/metabolismo , Macrófagos/virologia , Receptores CCR5/metabolismo , Proteína 1 com Domínio SAM e Domínio HD/metabolismo , Ativação Viral/efeitos dos fármacos , Latência Viral/efeitos dos fármacos , Replicação Viral/efeitos dos fármacosRESUMO
Effective function of CD8+ T cells and enhanced innate activation of DCs in response to HIV-1 is linked to protective antiviral immunity in controllers. Manipulation of DC targeting the master regulator TANK-binding Kinase 1 (TBK1) might be useful to acquire controller-like properties. Here, we evaluated the impact of the combination of 2´3´-c´diAM(PS)2 and Poly I:C as potential adjuvants capable of potentiating DC´s abilities to induce polyfunctional HIV-1 specific CD8+ T-cell responses in vitro and in vivo using a humanized BLT mouse model. Adjuvant combination enhanced TBK-1 phosphorylation and IL-12 and IFN-ß expression on DC and increased their ability to activate polyfunctional HIV-1-specific CD8+ T cells in vitro. Moreover, higher proportions of hBLT mice vaccinated with ADJ-DC exhibited less severe CD4+ T-cell depletion following HIV-1 infection compared to control groups. This was associated with infiltration of CD8+ T cells in the white pulp from the spleen, reduced spread of infected p24+ cells to LN, and with preserved abilities of CD8+ T cells from the spleen and blood of vaccinated animals to induce specific polyfunctional responses upon antigen stimulation. Therefore, priming of DC with PolyI:C and STING agonists might be useful for future HIV-1 vaccine studies.