Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 28(22): 32239-32248, 2020 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-33114915

RESUMO

Resonant biosensors are attractive for diagnostics because they can detect clinically relevant biomarkers with high sensitivity and in a label-free fashion. Most of the current solutions determine their detection limits in a highly stabilised laboratory environment, which does, however, not apply to real point-of-care applications. Here, we consider the more realistic scenario of low-cost components and an unstabilised environment and consider the related design implications. We find that sensors with lower quality-factor resonances are more fault tolerant, that a filtered LED lightsource is advantageous compared to a diode laser, and that a CMOS camera is preferable to a CCD camera for detection. We exemplify these findings with a guided mode resonance sensor and experimentally determine a limit of detection of 5.8 ± 1.7×10-5 refractive index units (RIU), which is backed up by a model identifying the various noise sources. Our findings will inform the design of high performance, low cost biosensors capable of operating in a real-world environment.


Assuntos
Técnicas Biossensoriais/economia , Refratometria/economia , Ressonância de Plasmônio de Superfície/instrumentação , Técnicas Biossensoriais/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Limite de Detecção , Refratometria/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Transdutores
2.
Sci Rep ; 7(1): 13990, 2017 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-29070904

RESUMO

Using a phoropter to measure the refractive error is one of the most commonly used methods by ophthalmologists and optometrists. Here, we demonstrate design and fabrication of a portable automatic phoropter with no need for patient's feedback. The system is based on three tunable-focus fluidic lenses and thin-film holographic optical elements to perform automatic refractive error measurement and provide a diagnostic prescription without supervision. Three separate lenses are deployed to correct the defocus and astigmatism. The refractive error is measured using a Shack-Hartmann wavefront sensor that calculates the Zernike values of an infrared wavefront emerging from the eye. Holographic optical elements steer the emerging wavefront into the wavefront sensor, while simultaneously providing an unobstructed view for the subject. The power of each lens is controlled by pumping a liquid in and out of the lens chamber using servo motor actuated diaphragm pumps. Spherical and cylindrical correction range of -10 to +10 diopters with 0.1 diopter increments is achieved in less than 15 seconds using wavefront sensor feedback to the pumps. This system can be used in rapid screening of large patient populations especially in the developing countries that lack sufficient facilities and specialist doctors.


Assuntos
Cristalino , Refração Ocular/fisiologia , Erros de Refração/diagnóstico , Refratometria/economia , Refratometria/instrumentação , Testes Visuais/instrumentação , Acuidade Visual/fisiologia , Países em Desenvolvimento , Desenho de Equipamento , Humanos , Erros de Refração/terapia
3.
Appl Opt ; 54(6): 1350-3, 2015 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-25968198

RESUMO

In this paper an alternative low-cost, easy-to-use, and fully automated profilometry setup is proposed. The setup is based on a phase-shifting fringe projection technique with four projected fringe parameters. It uses the well-known triangulation arrangement and low-cost electronic and image acquisition components such as a data acquisition board, a motor controller board, a printer rail, a CMOS webcam, and an LCD projector. The position of the camera, the generation of the fringe pattern, the acquisition of the images, and the calculation of the wrapped and unwrapped phase are all performed in LabVIEW. The setup is portable and can be perfectly adapted to be used in other profilometry techniques such as electronic speckle pattern interferometry and laser scanning profilometry.


Assuntos
Diagnóstico por Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional/instrumentação , Fenômenos Ópticos , Refratometria/economia , Algoritmos , Automação , Calibragem , Sistemas Computacionais , Desenho de Equipamento , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Reconhecimento Automatizado de Padrão/métodos , Refratometria/métodos
4.
Biosens Bioelectron ; 46: 15-21, 2013 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-23500471

RESUMO

We present a novel biosensor based on an electrical tracing-assisted silicon dual-microring resonator sensor system. The dual-microring system comprises one microring resonator as a sensing element and the other microring resonator integrated with an electrical controller as a tracing element. The resonance wavelength shift of the sensing microring induced by the refractive index change due to antigen-ligand bindings is traced and determined by direct voltage applied to the electrical tunable tracing microring. The sensor system enables the use of a low-cost broadband light source instead of a bulky and expensive tunable laser, which allows the development of cost-effective point-of-care diagnostic devices by significantly reducing the device cost and increasing its portability. The sensing capability of the developed dual-microring sensor was investigated using biotin-streptavidin binding as a model system. We have demonstrated the quantitative detection of streptavidin over a broad range of concentrations down to 190 pM by monitoring the electrical power applied to the tracing ring. We have also validated the sensing principle of the dual-microring system by a direct comparison between the calculated and measured values for the resonance wavelength shift of the sensing microring. Furthermore, we have shown the quantitative and specific detection of a well-known breast cancer biomarker, human epidermal growth factor receptor 2 (HER2), in a bovine serum albumin solution using the antibody-modified dual-microring sensor system.


Assuntos
Técnicas Biossensoriais/instrumentação , Receptor ErbB-2/análise , Silício/química , Estreptavidina/análise , Animais , Anticorpos Imobilizados/química , Técnicas Biossensoriais/economia , Desenho de Equipamento , Humanos , Luz , Refratometria/economia , Refratometria/instrumentação , Sensibilidade e Especificidade
5.
Opt Express ; 19(24): 24210-8, 2011 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-22109447

RESUMO

We design and demonstrate a birefringent Michelson interferometer based interleaver with ultra-low dispersion and low cost. The interleaver consists of polarizing beam splitters (PBS's) and quarter-wave plates and half-wave plates. The PBS's based Michelson interferometers provide the optical path difference for interference between the two orthogonal polarization components and the half-wave plates provide the birefringent needed to minimize ripple of output. The designed interleaver with two-stage interferometer in a 50 GHz channel spacing application exhibits a 0.5 dB passband and a 25 dB stopband both 27 GHz; a channel isolation higher than 35 dB and chromatic dispersion less than ±5 ps/nm within 0.5 dB passband; 1.3 dB insertion loss and 0.3 dB PDL; 0.04 GHz/°C thermal stability. Since all of the optical components can be optically bonded together, the device is robust and easy to be aligned, which reduces labor cost.


Assuntos
Interferometria/instrumentação , Refratometria/instrumentação , China , Desenho de Equipamento , Análise de Falha de Equipamento , Interferometria/economia , Refratometria/economia
6.
Pediatr Nurs ; 24(5): 480-2, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-9832909

RESUMO

Pediatric nurses in acute care settings routinely test urine for specific gravity, pH, glucose, protein, and other substances. In one tertiary care facility, nurses used the refractometer to test urine specific gravity and the reagent strip to test for other substances. This study was designed to provide data to determine if the reagent strip and the refractometer were interchangeable for measuring urine specific gravity in pediatric clients. Nurses obtained urine for specific gravity testing in 157 pediatric patients ranging in age from 1 day to 16 years. Each urine specimen was tested twice, once using the refractometer and once with the reagent strip. A Bland-Altman plot was used to determine the extent of agreement between the two measurement methods. The plot showed strong agreement between the two methods across a wide range of values for urine specific gravity. As a result of this study, staff nurses decided to use the reagent strip for urine specific gravity when other urine tests are needed and to use the refractometer when only a specific gravity is needed. This decision has resulted in a time savings for nurses who now do not have to repeat a reagent strip measurement. The decision also resulted in a savings of approximately $1200 in purchase of new refractometers for a newly constructed unit.


Assuntos
Fitas Reagentes/normas , Refratometria/instrumentação , Gravidade Específica , Urinálise/instrumentação , Adolescente , Criança , Pré-Escolar , Redução de Custos , Hospitalização , Humanos , Lactente , Recém-Nascido , Modelos Lineares , Enfermagem Pediátrica/métodos , Fitas Reagentes/economia , Refratometria/economia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
7.
Boll Soc Ital Biol Sper ; 74(3-4): 19-28, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-10965360

RESUMO

The amount of sclerotic root dentine increases with age, proceeding from the apex towards the crown. There are obvious optical changes in the tissue, which becomes translucent (dentine is normally opaque). Therefore, the sclerosis of root dentine could be a reliable indicator of age in anthropological studies of human remains. We studied the histological aspects of sclerotic dentine in longitudinal thin sections (70-140 microns) of undecalcified premolars, cut in the bucco-lingual plane. To quantify the sclerosis and to construct a reference standard, we sectioned 85 premolars from subjects of known age (70 from odontological extractions and 15 from a university collection). Another 10 teeth from medieval subjects were studied to assess the applicability of the method to ancient skeletal collections. The technique consists of embedding the tooth in a polyester resin (cold method), sectioning it with a diamond blade microtome. Qualitative analysis was performed with polarized light microscopy and measurements were made with a quote 2D x,y viewer and on digital images. The sclerotic root dentine was quantified with both linear and surface area parameters in order to assess the correlation with age. The quality of the sections was sufficient for the clear discernment and quantification of the sclerotic dentine. Indeed, the technique allowed us to obtain good results with a considerable saving of time and money compared with other dental histological techniques. The best correlation with age was obtained from the surface area parameter, particularly after exclusion of the cementum and pulp chamber. To produce comparable data from similar studies, we advise the use of cold resins, as used here, and digital computerized analyzers because of their accuracy, precision and quickness. The qualitative analysis of the ancient teeth indications that this dental aging techniques can be applied to both recent and ancient dental tissues.


Assuntos
Determinação da Idade pelos Dentes , Dente Pré-Molar/crescimento & desenvolvimento , Cementogênese , Dentina/crescimento & desenvolvimento , Microscopia de Polarização/métodos , Refratometria , Raiz Dentária/crescimento & desenvolvimento , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Dente Pré-Molar/microbiologia , Dente Pré-Molar/patologia , Criança , Análise Custo-Benefício , Cemento Dentário/microbiologia , Cemento Dentário/patologia , Dentina/microbiologia , Dentina/patologia , Fungos/isolamento & purificação , Humanos , Processamento de Imagem Assistida por Computador , Microscopia de Polarização/economia , Microtomia/métodos , Pessoa de Meia-Idade , Valores de Referência , Refratometria/economia , Refratometria/métodos , Esclerose , Inclusão do Tecido/métodos , Raiz Dentária/microbiologia , Raiz Dentária/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA