Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.681
Filtrar
1.
BMC Nephrol ; 25(1): 313, 2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39300387

RESUMO

BACKGROUND: The utilization of ultrapure dialysate has been shown to decrease dialysate contamination and mitigate inflammatory responses. The central dialysate delivery system (CDDS) has the potential to attain a level of purity similar to ultrapure dialysate. Nevertheless, there is limited research examining the impact of CDDS on inflammation in comparison to single-patient dialysis fluid delivery system(SPDDS). This study aims to investigate the effects of CDDS utilizing ultrapure dialysate on ameliorating the microinflammatory state in hemodialysis patients. METHOD: A retrospective cohort clinical study enrolled a total of 125 hemodialysis patients, with 58 patients from the CDDS unit and 67 patients from the SPDDS unit. Each participant was monitored for a period of 6 months, and the repeated measurement data was analyzed using a generalized linear mixed models (GLMM). RESULTS: The average age of the studty cohort was 56.22 ± 12.64 years. The GLMM analysis showed a significant time*group interaction effect on hs-CRP changes over the follow-up period (ß = -1.966, FTime* CDDS group = 13.389, P < 0.001). A linear mixed model analysis with random slope showed that a different slope was observed between CDDS group and SPDDS group (ßCDDS =-0.793; ßSPDDS = 0.791), indicating a decreased hs-CRP levels in CDDS group, while increased in the SPDDS group over the follow-up period. However, no significant time*group interaction effect were observed on albumin and ß2-microglobulin levels during follow-up period(ß2-microglobulin: ß = -0.658, FTime* CDDS group = 1.228, P = 0.269; albumin: ß = 0.012, FTime* CDDS group = 1.429, P = 0.233). CONCLUSION: Using ultrapure dialysate in the CDDS is associated with an improvement in hs-CRP levels compared to standard dialysate, which might confer long-term clinical advantages.


Assuntos
Biomarcadores , Inflamação , Diálise Renal , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Inflamação/sangue , Biomarcadores/sangue , Idoso , Proteína C-Reativa/análise , Proteína C-Reativa/metabolismo , Microglobulina beta-2/sangue , Estudos de Coortes , Adulto , Falência Renal Crônica/terapia , Falência Renal Crônica/sangue , Soluções para Diálise , Soluções para Hemodiálise
2.
G Ital Nefrol ; 41(4)2024 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-39243417

RESUMO

Cool dialysate has variable impact on hemodynamic stability and dialysis adequacy. Hemodynamic stability and dialysis adequacy are crucial indicators for better life expectancy and cardiovascular mortality. This research aims to evaluate the impact of cool dialysate temperature (35.5°C) compared to standard dialysate temperature (37°C) on blood pressures, pulse rate, and dialysis adequacy (Urea reduction ratio and online Kt/V) in a cross over design. Material and Methods. Consenting ESRD patients on maintenance haemodialysis (HD) with minimum 3 months dialysis vintage and functioning permanent vascular access are included for the study. Each participant had two sessions of HD at 37°C followed by two sessions at 35.5° C on a Fresenius 4008S HD machine. Systolic blood pressure (SBP), diastolic blood pressure (DBP) and Pulse rate are measured pre-HD, every hourly and post dialysis. Pre-HD Blood urea nitrogen (BUN) and post-HD BUN are measured, and Urea reduction rate was calculated for each HD session. Kt/V was calculated by ionic conductance by HD machine for each session. Results. 25 patients (5 females and 20 males) were enrolled. The mean age was 54 ± 9.58 years. Dialysis vintage was 21.48 ± 6.9 months for study participants 10 patients (40%) were diabetic nephropathy, 9 patients (36%) were presumed chronic glomerulonephritis, 2 patients (8%) were lupus nephritis and 4 patients (16%) were chronic interstitial nephritis. There was statistically no difference between pre-HD BUN (p = 0.330), post-HD BUN (p = 0.776), URR (p = 0.718) and Kt/V (p = 0.534) among the dialysis sessions done at 37°C and 35.5°C. SBP variability in the low temperature (35.5°C) group at 4th hour and post dialysis assumed statistical significance with p = 0.05 and p = 0.025 respectively. DBP variability in the low temperature (35.5°C) group at 3rd hour, 4th hour and post-dialysis demonstrated statistical significance with p = 0.027, p = 0.36 and p = 0.016 respectively. Pulse rate variability was more in the low temperature (35.5°C) group at 3rd hour and 4th hour which showed statistical significance with p = 0.037 and p = 0.05 respectively. Conclusion. Cool dialysate is non inferior to standard dialysate temperature in terms of dialysis adequacy and is associated with less variability in diastolic blood pressure, systolic blood pressure and more pulse rate variability thereby contributing to better hemodynamic stability.


Assuntos
Estudos Cross-Over , Hemodinâmica , Falência Renal Crônica , Diálise Renal , Humanos , Feminino , Masculino , Diálise Renal/métodos , Pessoa de Meia-Idade , Falência Renal Crônica/terapia , Falência Renal Crônica/fisiopatologia , Pressão Sanguínea , Soluções para Diálise/química , Soluções para Hemodiálise/química , Temperatura , Frequência Cardíaca , Idoso , Temperatura Baixa , Nitrogênio da Ureia Sanguínea
4.
Artif Organs ; 48(8): 812-820, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38837801

RESUMO

BACKGROUND: Debate continues as to the optimum hemodialysis (HD) dialysate calcium concentration. Although current guidelines advocate 1.25-1.5 mmol/L, some investigators have suggested these may cause calcium gains. As such we investigated whether using dialysate calcium of 1.25 mmol/L risked calcium gains, and whether there were differences between hemodiafiltration and high flux HD. METHODS: We continuously collect an aliquot of effluent dialysate during dialysis sessions, and calculated dialysis calcium mass balance by the difference between the amount of calcium delivered as fresh dialysate and that lost in effluent dialysate. RESULTS: We studied 106 stable outpatients, 64% male, mean age 64.4 ± 16.2 years, median dialysis vintage 32 (22-60) months. Most sessions (69%) used a 1.0 mmol/L calcium dialysate, with a median sessional loss of 13.7 (11.5-17.1) mmol, whereas using 1.25 mmol/L the median loss was 7.4 (4.9-10.1) mmol, but with 6.9% had a positive balance (p = 0.031 vs dialysate calcium 1.0 mmol/L). Most patients (85.8%) were treated by hemodiafiltration, but there was no difference in sessional losses (11.7 (8.4-15.8) vs 13.5 (8.1-16.8)) with high flux HD. Dialysis sessional calcium balance was associated with the use of lower dialysate calcium concentration (ß -19.5, 95% confidence limits (95%CL) -27.7 to -11.3, p < 0.001), and sessional duration (ß 0.07 (95% CL) 0.03-012, p = 0.002). CONCLUSION: Ideally, the choice of dialysate calcium should be individualized, but clinicians should be aware, that even when using a dialysate calcium of 1.25 mmol/L, some patients are at risk of a calcium gain during hemodiafiltration and high-flux hemodialysis.


Assuntos
Cálcio , Soluções para Diálise , Hemodiafiltração , Diálise Renal , Humanos , Masculino , Pessoa de Meia-Idade , Hemodiafiltração/métodos , Feminino , Cálcio/análise , Idoso , Diálise Renal/métodos , Diálise Renal/efeitos adversos , Soluções para Diálise/química , Idoso de 80 Anos ou mais , Falência Renal Crônica/terapia , Soluções para Hemodiálise/química
5.
G Ital Nefrol ; 41(3)2024 06 28.
Artigo em Italiano | MEDLINE | ID: mdl-38943331

RESUMO

Introduction and aim of the study. The centralized preparation and distribution system of acidic concentrate represents a true innovation in hemodialysis, when compared to acid bags, in terms of convenience and eco-sustainability. The aim of this study is to compare the use of traditional acid bags with the centralized distribution system of acidic concentrate, with particular attention to differences in terms of eco-sustainability and convenience. Methods. At the Nephrology Dialysis and Renal Transplantation Unit of the University Hospital of Modena was installed the Granumix system® (Fresenius Medical Care, Bad Homburg, Germany). Data collected before the introduction of the Granumix® system (including the used acid bags, boxes and pallets used for their packaging, liters of acid solution used and kilograms of waste generated from wood, plastic, cardboard and residual acid solution) were compared with those collected after the implementation of the Granumix® system. Factors such as material consumption, volume of waste generated, unused and wasted products, time required for dialysis session preparation and nurses' satisfaction were analyzed to document which system was more environmentally sustainable. Results. Data collected in 2019 at our Dialysis Center showed a consumption of 30,000 acid bags, which generated over 20,000 kg of waste from wood, plastic and cardboard, and approximately 12,000 liters of residual acid solution to be disposed of, with a handling weight by operators reaching nearly 160,000 kg. The use of the centralized distribution system of acidic concentrate resulted in a significant reduction in waste generated (2,642 kg vs 13,617 kg), residual acid solution to be disposed of (2,351 liters vs 12,100 liters) and weights handled by operators (71,522 kg vs 158,117 kg). Conclusions. The acidic concentrate appears to be better suited to the sustainability challenge that dialysis must faces today, particularly due to the significant increase in the number of patients, which leads to a higher number of treatments and, therefore, a growing demand for eco-sustainable products.


Assuntos
Diálise Renal , Humanos , Itália , Ácidos , Soluções para Hemodiálise , Conservação dos Recursos Naturais
6.
Artif Organs ; 48(7): 704-712, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38716639

RESUMO

BACKGROUND: Regional anticoagulation in hemodialysis avoids the use of heparin, which is responsible for both hemorrhagic and non-hemorrhagic complications. Typically, blood is decalcified by injecting citrate into the arterial line of the extracorporeal circuit. Calcium-free dialysate improves anticoagulation efficacy but requires injection of a calcium-containing solution into the venous line and strict monitoring of blood calcium levels. Recent improvements have made regional anticoagulation with calcium-free dialysate safer and easier. OBSERVATIONS: (1) Adjusting the calcium injection rate to ionic dialysance avoids the risk of dyscalcemia, thus making unnecessary the monitoring of blood calcium levels. This adjustment could be carried out automatically by the hemodialysis monitor. (2) As calcium-free dialysate reduces the amount of citrate required, this can be supplied by dialysate obtained from currently available concentrates containing citric acid. This avoids the need for citrate injection and the risk of citrate overload. (3) Calcium-free dialysate no longer needs the dialysate acidification required for avoiding calcium carbonate precipitation in bicarbonate-containing dialysate. CONCLUSIONS: Regional anticoagulation with calcium-free dialysate enables an acid- and heparin-free procedure that is more biocompatible and environmentally friendly than conventional bicarbonate hemodialysis. The availability of specific acid-free concentrates and adapted hemodialysis monitors is required to extend this procedure to maintenance hemodialysis.


Assuntos
Anticoagulantes , Cálcio , Diálise Renal , Humanos , Diálise Renal/métodos , Diálise Renal/instrumentação , Anticoagulantes/administração & dosagem , Soluções para Diálise/química , Ácido Cítrico/administração & dosagem , Ácido Cítrico/química , Coagulação Sanguínea/efeitos dos fármacos , Soluções para Hemodiálise/química
7.
Int Urol Nephrol ; 56(7): 2313-2323, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38446246

RESUMO

PURPOSE: The present systematic review and meta-analysis aimed at evaluating the effect of low dialysate sodium concentration on interdialytic weight gain (IDWG) in chronic hemodialysis patients. METHODS: Studies were eligible for inclusion if they were English language papers published in a peer-reviewed journal and met the following inclusion criteria: (1) studies in adult patients (over 18 years of age), (2) included patients on chronic hemodialysis since at least 6 months; (3) compared standard (138-140 mmol/l) or high (> 140 mmol/l) dialysate sodium concentration with low (< 138 mmol/l) dialysate sodium concentration; (4) Included one outcome of interest: interdialytic weight gain. Medline, PubMed, Web of Science, and the Cochrane Library were searched for the quality of reporting for each study was performed using the Quality Assessment Tool of Controlled Intervention Studies of the National Institutes of Health. The quality of reporting of each cross-over study was performed using the Revised Cochrane Risk of Bias (RoB) tool for cross-over trials as proposed by Ding et al. RESULTS: Nineteen studies (710 patients) were included in the analysis: 15 were cross-over and 4 parallel randomized controlled studies. In cross-over studies, pooled analysis revealed that dialysate sodium concentration reduced IDWG with a pooled MD of - 0.40 kg (95% CI - 0.50 to - 0.30; p < 0.001). The systematic review of four parallel, randomized, studies revealed that the use of a low dialysate sodium concentration was associated with a significant reduction of the IDWG in two studies, sustained and almost significant (p = 0.05) reduction in one study, and not significant reduction in one study. CONCLUSION: Low dialysate sodium concentration reduces the IDWG in prevalent patients on chronic hemodialysis.


Assuntos
Soluções para Diálise , Diálise Renal , Sódio , Aumento de Peso , Humanos , Sódio/análise , Falência Renal Crônica/terapia , Soluções para Hemodiálise/química
8.
Clin Exp Nephrol ; 28(6): 557-570, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38396314

RESUMO

BACKGROUND: The optimal dialysate calcium (Ca) concentration for patients undergoing hemodialysis remains inconclusive, particularly concerning cardiovascular protection. METHODS: We conducted a systematic review of 19 randomized controlled trials (RCTs) and a meta-analysis of eight RCTs to determine the optimal dialysate Ca concentration for cardiovascular protection. We compared outcomes in patients receiving maintenance hemodialysis treated with either a low-Ca dialysate (LCD) (1.125 or 1.25 mmol/L) or a high-Ca dialysate (HCD) (1.5 or 1.75 mmol/L). The outcomes were coronary artery calcification score (CACS), all-cause and cardiovascular death, cardiovascular function and structure, and serum biochemical parameters. RESULTS: There was no significant difference between LCD and HCD concerning CACS (standardized mean difference [SMD] = -0.16, 95% confidence interval [CI]: [-0.38, 0.07]), the risk of all-cause death, and cardiovascular death in patients treated with chronic maintenance hemodialysis. Conversely, LCD was associated with a significantly lower intima-media thickness (SMD = -0.49, 95% CI [-0.94, -0.05]) and pulse wave velocity than HCD (SMD = -0.86, 95% CI [-1.21, -0.51]). Furthermore, LCD significantly decreased serum Ca levels (mean difference [MD] = 0.52 mg/dL, 95% CI [0.19, 0.85]) and increased serum parathyroid hormone levels (MD = 44.8 pg/mL, 95% CI [16.2, 73.3]) compared with HCD. Notably, most RCTs examined in our analysis did not include patients receiving calcimimetics. CONCLUSIONS: Our meta-analysis showed no significant differences in cardiovascular calcification and death between LCD and HCD and revealed a paucity of RCTs on dialysate Ca concentrations, including those involving patients on calcimimetics, indicating the urgent need for further studies.


Assuntos
Cálcio , Doenças Cardiovasculares , Soluções para Hemodiálise , Diálise Renal , Humanos , Diálise Renal/efeitos adversos , Cálcio/sangue , Doenças Cardiovasculares/mortalidade , Doenças Cardiovasculares/prevenção & controle , Soluções para Hemodiálise/efeitos adversos , Soluções para Hemodiálise/química , Ensaios Clínicos Controlados Aleatórios como Assunto , Hormônio Paratireóideo/sangue , Pessoa de Meia-Idade , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/prevenção & controle , Resultado do Tratamento
10.
Rev. baiana enferm ; 38: e53348, 2024. tab, graf
Artigo em Português | LILACS, BDENF - Enfermagem | ID: biblio-1559305

RESUMO

Objetivo: mapear os Diagnósticos de Enfermagem da taxonomia NANDA-I validados para pacientes renais crônicos submetidos a hemodiálise. Método: revisão de escopo registrada no Open Science Framework, guiada pelo método JBI e norteada pelo Preferred Reporting Items for Systematic reviews and Meta-Analyses extension for Scoping Reviews. As buscas foram realizadas nas bases Medical Literature Analysis and Retrievel System, Cummulative Index to Nursing and Allied Health Literature, entre outras, além da literatura cinzenta. Dados analisados descritivamente. Não houve recorte temporal ou idiomático. Resultados: identificados 12 estudos com 6 Diagnósticos de Enfermagem validados para pacientes renais crônicos submetidos a hemodiálise: volume de líquidos excessivo, proteção ineficaz, autogestão ineficaz da saúde, espiritualidade prejudicada, disposição para melhora da esperança e hipotermia. Conclusão: o mapeamento dos Diagnósticos de Enfermagem da taxonomia NANDA-I mostrou que a qualidade do processo de enfermagem tende a melhorar, quando diagnósticos de enfermagem são validados, conferindo maior confiabilidade e segurança à prática clínica.


Objetivo: mapear los Diagnósticos de Enfermería de la taxonomía NANDA-I validados para pacientes renales crónicos sometidos a hemodiálisis. Método: Revisión de ámbito registrada en el Open Science Framework, guiada por el método JBI y guiada por el Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews. Las búsquedas fueron realizadas en las bases Medical Literature Analysis and Retrieval System, Cumulative Index to Nursing and Allied Health Literature, entre otras, además de la literatura gris. Datos analizados descriptivamente. No hubo recorte temporal o idiomático. Resultados: identificados 12 estudios con 6 Diagnósticos de Enfermería validados para pacientes renales crónicos sometidos a hemodiálisis: volumen de líquidos excesivo, protección ineficaz, autogestión ineficaz de la salud, espiritualidad perjudicada, disposición para mejorar la esperanza y la hipotermia. Conclusión: el mapeo de los Diagnósticos de Enfermería de la taxonomía NANDA-I mostró que la calidad del proceso de enfermería tiende a mejorar, cuando diagnósticos de enfermería son validados, confiriendo mayor confiabilidad y seguridad a la práctica clínica.


Objective: to map the Nursing Diagnoses of the NANDA-I taxonomy validated for chronic kidney disease patients undergoing hemodialysis. Method: scope review recorded in the Open Science Framework, guided by the JBI method and guided by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews. The searches were performed in the Medical Literature Analysis and Retrieval System, Cumulative Index to Nursing and Allied Health Literature, among others, besides the gray literature. Data analyzed descriptively. There was no temporal or idiomatic cut. Results: 12 studies were identified with 6 validated Nursing Diagnoses for chronic kidney disease patients undergoing hemodialysis: excessive volume of fluids, ineffective protection, ineffective health self-management, impaired spirituality, willingness to improve hope and hypothermia. Conclusion: the mapping of Nursing Diagnoses of the NANDA-I taxonomy showed that the quality of the nursing process tends to improve when nursing diagnoses are validated, giving greater reliability and safety to clinical practice.


Assuntos
Humanos , Diálise Renal/enfermagem , Soluções para Hemodiálise/análise
11.
Ther Apher Dial ; 27(6): 1053-1063, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37381091

RESUMO

Hemodialysis is considered a treatment of choice for patients with renal failure worldwide, allowing the replacement of some kidney functions by diffusion and ultrafiltration processes. Over 4 million people require some form of renal replacement therapy, with hemodialysis being the most common. During the procedure, contaminants in the water and the resulting dialysate may pass into the patient's blood and lead to toxicity. Thus, the quality of the associated dialysis solutions is a critical issue. Accordingly, the discussion of the importance of a dialysis water delivery system controlled by current standards and recommendations, with efficient monitoring methods, disinfection systems, and chemical and microbiological analysis, is crucial for improving the health outcomes of these patients. The importance of treatment, monitoring, and regulation is emphasized by presenting several case studies concerning the contamination of hemodialysis water and the adverse effects on the respective patients.


Assuntos
Terapia de Substituição Renal Contínua , Qualidade da Água , Humanos , Diálise Renal/efeitos adversos , Soluções para Diálise/efeitos adversos , Ultrafiltração , Soluções para Hemodiálise/efeitos adversos
12.
ACS Appl Mater Interfaces ; 15(24): 28907-28921, 2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37285144

RESUMO

In an attempt to address the significant morbidity, mortality, and economic cost associated with tunneled dialysis catheter (TDC) dysfunction, we report the development of nitric oxide-releasing dialysis catheter lock solutions. Catheter lock solutions with a range of NO payloads and release kinetics were prepared using low-molecular-weight N-diazeniumdiolate nitric oxide donors. Nitric oxide released through the catheter surface as a dissolved gas was maintained at therapeutically relevant levels for at least 72 h, supporting clinical translatability (interdialytic period). Slow, sustained NO release from the catheter surface prevented bacterial adhesion in vitro by 88.9 and 99.7% for Pseudomonas aeruginosa and Staphylococcus epidermidis, respectively, outperforming a burst NO-release profile. Furthermore, bacteria adhered to the catheter surface in vitro prior to lock solution use was reduced by 98.7 and 99.2% for P. aeruginosa and S. epidermidis, respectively, when using a slow releasing NO donor, demonstrating both preventative and treatment potential. The adhesion of proteins to the catheter surface, a process often preceding biofilm formation and thrombosis, was also lessened by 60-65% by sustained NO release. In vitro cytotoxicity of catheter extract solutions to mammalian cells was minimal, supporting the non-toxic nature of the NO-releasing lock solutions. The use of the NO-releasing lock solution in an in vivo TDC porcine model demonstrated decreased infection and thrombosis, enhanced catheter functionality, and improved outcome (i.e., likelihood of survival) as a result of catheter use.


Assuntos
Infecções Relacionadas a Cateter , Cateteres Venosos Centrais , Trombose , Animais , Antibacterianos/uso terapêutico , Infecções Relacionadas a Cateter/microbiologia , Soluções para Hemodiálise , Mamíferos , Óxido Nítrico , Diálise Renal , Suínos , Trombose/tratamento farmacológico
13.
Blood Purif ; 52(5): 401-406, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-33684920

RESUMO

Dialysis therapy is the predominant choice for renal failure in Japan, and almost 30% of the patients with renal failure have been treated for 10 years or more. Dialysis became the standard procedure to treat renal failure nationwide in the 1980s. However, at that time, managing the increased number of patients on maintenance hemodialysis as well as operating and maintaining the newly developed advanced medical technologies at extensive numbers of clinical sites proved problematic. To help address this, the clinical engineer system was established in 1987 and certain aspects of the clinical engineers' role remain unique to Japan today. For the last 30 years, clinical engineers have worked as frontline medical personnel not only operating dialysis-related devices but also placing their hands directly on patients when providing care, routinely performing puncture, and administering drugs through the blood circuit under physicians' instructions. As part of their work, they crucially maintain the use of central dialysis fluid delivery systems (CDDSs) - also unique to Japan - which prepare and deliver a large quantity of dialysis fluid through a central circuit to individual dialysis consoles. CDDSs are widely used because they effectively alleviated the early confusion at clinical sites caused by the rapidly increasing hemodialysis population and the serious shortage in medical personnel. Moreover, clinical engineers alone have the technical ability to provide safe dialysis fluids adjusted to strict standards at clinical sites. In this review article, we focus on the crucial roles that clinical engineers have in maintaining the safety of dialysis-related medical devices and the preparation and delivery of dialysis fluid at many dialysis facilities across the country.


Assuntos
Diálise Renal , Insuficiência Renal , Humanos , Soluções para Hemodiálise , Japão , Soluções para Diálise , Gestão da Segurança
14.
Semin Dial ; 36(1): 24-28, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35384078

RESUMO

BACKGROUND: Hemodialysis solutions typically contain a high alkali concentration designed to counter interdialytic acidosis, but this could result in persistent alkalosis in some patients. The prevalence and significance of persistent alkalosis were therefore examined at four outpatient centers over a 10-year period. METHODS: Alkalosis was defined as a pre-dialysis serum [HCO3 ] ≥ 26 meq/L in >6 months of a 12-month period and was persistent if present in a majority of months thereafter. Control patients had a serum [HCO3 ] of 19-23 meq/L > 6 of every 12 months. Standard, citrate-containing dialysate was used in all patients without adjustment of bicarbonate concentration. RESULTS: 444 of 1271 patients had alkalosis that persisted in 73. Compared to control patients, persistently alkalotic patients were older, but gender, race, starting weight, comorbidities, and mortality did not differ. Dialysis dose was 7% greater, protein catabolic rate was 11% lower, and interdialytic weight gain was 29% lower, all p < 0.001. Persistently alkalotic patients had double the incidence of cardiac arrhythmias (p = 0.07) and a 20% greater intradialytic blood pressure decrease (p < 0.001). CONCLUSIONS: Alkalosis is common in hemodialysis patients and can be persistent, likely due to decreased protein catabolic rate and increased dialysis dose, and may have detrimental cardiovascular effects.


Assuntos
Alcalose , Diálise Renal , Humanos , Diálise Renal/efeitos adversos , Estudos Prospectivos , Soluções para Diálise , Soluções para Hemodiálise , Alcalose/epidemiologia , Alcalose/etiologia , Bicarbonatos/metabolismo
15.
Perfusion ; 38(1): 178-185, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-34541941

RESUMO

OBJECTIVE: To investigate the effects of glucose-free and glucose-containing dialysates during dialysis in maintenance hemodialysis (MHD) patients by the prospective cross-over study, and detect glucose control methods in MHD patients. METHODS: A total of 66 MHD 18-75 years old patients in our hospital from Nov. 2019 to Mar. 2020 were recruited. All patients underwent HD with 4 hours per time, three times per week. Glucose-free dialysate (glucose-free group) and then 5.55 mmol/L glucose-containing dialysate (glucose-5.55 group) were used alternately in dialysis. The demographics and parameters of pre- and post-dialysis were recorded. RESULTS: A total of 60 patients were analyzed, and 28 patients among them had type 2 diabetes. Serum glucose pre and post dialysis were 8.64 ± 4.18 mmol/L versus 5.74 ± 1.82 mmol/L (p < 0.01) in glucose-free dialysate, and 9.31 ± 4.89 mmol/L versus 7.80 ± 2.59 mmol/L (p < 0.01) in glucose-5.55 dialysate. The post-dialysis blood glucose of glucose-free group was lower than glucose-5.55 group (5.74 ± 1.82 vs 7.80 ± 2.59, p < 0.01). About 18 (30.00%) patients in glucose-free group and 1 patient (1.67%) in glucose-5.55 group whose blood glucose was lower than 4.44 mmol/L (p < 0.01). About 29 patients (48.33%) in glucose-free group and 17 patients (28.33%; p = 0.02) in glucose-5.55 group have hunger feeling. Serum sodium level in the glucose-free group was higher than that in Glucose-5.55 group (137.92 ± 1.64 vs 136.70 ± 1.64, p < 0.01). Post-dialysis blood glucose had no significant differences between patients not using diabetes-related medication (13 patients) and patients using diabetes-related medication (15 patients) in glucose-free group (7.13 ± 1.78 mmol/L vs 6.08 ± 2.84 mmol/L, p = 0.23) and glucose-5.55 group (9.22 ± 2.59 mmol/L vs 9.35 ± 2.88 mmol/L, p = 0.90). CONCLUSIONS: Glucose-free and glucose-5.55 dialysate both decrease the blood glucose post-dialysis. Dialysates containing 5.55 mmol/L glucose can reduce the incidence of hypoglycemia and lower serum sodium, but have no effect on blood pressure during dialysis. Stopping insulin and oral anti-diabetic drugs once before dialysis may not affect the control of blood glucose.


Assuntos
Diabetes Mellitus Tipo 2 , Falência Renal Crônica , Adolescente , Adulto , Idoso , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Glicemia , Estudos Cross-Over , Diabetes Mellitus Tipo 2/tratamento farmacológico , Soluções para Diálise/farmacologia , Soluções para Diálise/uso terapêutico , Glucose/farmacologia , Glucose/uso terapêutico , Soluções para Hemodiálise , Falência Renal Crônica/terapia , Estudos Prospectivos , Diálise Renal/métodos , Sódio
16.
Cambios rev med ; 21(2): 837, 30 Diciembre 2022. ilus, tabs.
Artigo em Espanhol | LILACS | ID: biblio-1416043

RESUMO

INTRODUCCIÓN. La falla hepática ya sea aguda o crónica reagudizada representa un reto para el clínico ya que sus complicaciones conllevan una gran mortalidad, esto se ve aún más complicado ya que las opciones terapéuticas son limitadas, incluso muchas veces no se puede acceder a un programa de trasplante hepático oportuno que mejore la sobrevida de estos pacientes, es así que se ha desarrollado un sistema de "diálisis" hepática conocido como sistema de recirculación de adsorbentes moleculares el cual hace un efecto de detoxificación para eliminar sustancias que generan una noxa en el cuerpo humano. OBJETIVO. Entender la utilidad del sistema recirculante molecular adsorbente en la falla hepática, conocer sus indicaciones y complicaciones. METODOLOGÍA. Se realizó una revisión de la literatura con un enfoque descriptivo, retrospectivo cualitativo no experimental, de documentos que tratan sobre la utilización del sistema MARS para tratar la falla hepática, con evidencia desde el año 2004 hasta el 2021. La revisión bibliográfica se llevó a cabo en bases de datos como Pubmed, Embase, BVS, Google Scholar y Elsevier. RESULTADOS. Se identificaron 30 artículos que cumplieron criterios de inclusión de un grupo original de 343 artículos revisados. Se ha determinado que la evidencia sobre este sistema está compuesta sobre todo por reportes de caso y son pocos los ensayos controlados aleatorizados que empleen su uso, sin embargo, se ha podido determinar que este sistema es un puente al trasplante renal mientras se estabiliza al paciente en la Unidad de Cuidados Intensivos, disminuye los marcadores de falla hepática. CONCLUSIÓN. En Latinoamérica su uso es casi nulo de ahí la necesidad de entender el mecanismo de este novedoso sistema.


INTRODUCTION. Hepatic failure, whether acute or chronic, represents a challenge for the clinician since its complications entail a great mortality, this is even more complicated since the therapeutic options are limited, even many times it is not possible to access a timely liver transplant program to improve the survival of these patients, Thus, a hepatic "dialysis" system known as molecular adsorbent recirculation system has been developed, which has a detoxification effect to eliminate substances that generate a noxa in the human body. OBJECTIVE. To understand the usefulness of the molecular adsorbent recirculating system in liver failure, to know its indications and complications. METHODOLOGY. A literature review was performed with a descriptive, retrospective qualitative non-experimental qualitative approach, of papers dealing with the use of the MARS system to treat liver failure, with evidence from 2004 to 2021. The literature review was conducted in databases such as Pubmed, Embase, BVS, Google Scholar and Elsevier. RESULTS. Thirty articles were identified that met inclusion criteria from an original group of 343 articles reviewed. It has been determined that the evidence on this system is mainly composed of case reports and there are few randomized controlled trials that employ its use, however, it has been determined that this system is a bridge to renal transplantation while the patient is stabilized in the Intensive Care Unit, decreasing the markers of liver failure. CONCLUSIONS. In Latin America its use is almost null, hence the need to understand the mechanism of this novel system.


Assuntos
Humanos , Masculino , Feminino , Soluções para Hemodiálise/química , Encefalopatia Hepática , Falência Hepática/terapia , Adsorção , Albuminas/uso terapêutico , Unidades de Terapia Intensiva , Falência Hepática Aguda , Falência Hepática , Diálise , Albuminas , Equador , Hepatopatias
17.
Bioanalysis ; 14(19): 1257-1270, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36416749

RESUMO

Aim: To develop and validate a bioanalytical method for the quantification of INCB000928 in hemodialysate. Materials & methods: Blank dialysate and phosphate-buffered saline were compared with hemodialysate for surrogate matrix selection. Direct addition of internal standard without analyte extraction and a high-performance LC-MS/MS were used for analysis. Results & conclusion: INCB000928 in hemodialysate exhibited strong nonspecific binding to polypropylene containers. In the presence of 10% isopropyl alcohol, the loss of INCB000928 was fully recovered, regardless of pre- or post-addition of the solvent. Blank dialysate and phosphate-buffered saline were determined to be appropriate surrogate matrices by using a three-way cross-comparison and were subsequently validated in the quantitative analysis of INCB000928 in hemodialysate.


Fibrodysplasia ossificans progressiva (FOP) is a very rare disease characterized by congenital malformation of the great toes and progressive heterotopic ossification. The genetic cause of FOP is mutation in the gene ALK2. INCB000928 is a novel and orally available drug that inhibits ALK2 protein activity and has been shown to prevent ossification in a laboratory mouse model of FOP. Patients with end-stage renal disease who undergo hemodialysis may require a different dose of INCB000928. This study showed that INCB000928 was heavily adsorbed by the container wall, resulting in underestimated drug levels in hemodialysate. We present a method to accurately measure INCB000928 levels in hemodialysate by using isopropyl alcohol as an antiadsorption agent and cost-effective surrogate matrix.


Assuntos
Miosite Ossificante , Humanos , Soluções para Hemodiálise , Cromatografia Líquida , Receptores de Ativinas Tipo I/metabolismo , Espectrometria de Massas em Tandem , Inibidores de Proteínas Quinases , Fosfatos
18.
PLoS One ; 17(6): e0268751, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35666735

RESUMO

BACKGROUND: Mass spectrometry (MS) analysis using direct infusion of biological fluids is often problematic due to high salts/buffers. Iodinated contrast media (ICM) are frequently used for diagnostic imaging purposes, sometimes inducing acute kidney injury (AKI) in patients with reduced kidney function. Therefore, detection of ICM in spent hemodialysates is important for AKI patients who require urgent continuous hemodiafiltration (CHDF) because it allows noninvasive assessment of the patient's treatment. In this study, we used a novel desalination tube before MS to inject the sample directly and detect ICM. METHODS: Firstly, spent hemodialysates of one patient were injected directly into the electrospray ionization (ESI) source equipped with a quadrupole time-of-flight mass spectrometer (Q-TOF MS) coupled to an online desalination tube for the detection of ICM and other metabolites. Thereafter, spent hemodialysates of two patients were injected directly into the ESI source equipped with a triple quadrupole mass spectrometer (TQ-MS) connected to that online desalination tube to confirm the detection of ICM. RESULTS: We detected iohexol (an ICM) from untreated spent hemodialysates of the patient-administered iohexol for computed tomography using Q-TOF MS. Using MRM profile analysis, we have confirmed the detection of ICM in the untreated spent hemodialysates of the patients administered for coronary angiography before starting CHDF. Using the desalination tube, we observed approximately 178 times higher signal intensity and 8 times improved signal-to-noise ratio for ioversol (an ICM) compared to data obtained without the desalination tube. This system was capable of tracking the changes of ioversol in spent hemodialysates of AKI patients by measuring spent hemodialysates. CONCLUSION: The online desalination tube coupled with MS showed the capability of detecting iohexol and ioversol in spent hemodialysates without additional sample preparation or chromatographic separation. This approach also demonstrated the capacity to monitor the ioversol changes in patients' spent hemodialysates.


Assuntos
Injúria Renal Aguda , Compostos de Iodo , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/diagnóstico , Meios de Contraste/efeitos adversos , Soluções para Hemodiálise , Humanos , Iohexol , Espectrometria de Massas , Espectrometria de Massas por Ionização por Electrospray
19.
In Vivo ; 36(4): 1769-1776, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35738602

RESUMO

BACKGROUND/AIM: Supra hemodiafiltration with reinfusion of the endogenous ultrafiltrate (Supra-HFR) is a dialysis technique used to improve uremic toxin removal in the range of the middle molecular weight molecules. Supra-HFR does not require the preparation and online infusion of high-purity dialysis water because it allows the production of an endogenous ultrafiltrate that undergoes detoxification through an adsorbing resin. PATIENTS AND METHODS: We investigated the ability of Supra-HFR to remove fibroblast growth factor 23 (FGF23), interleukin 6 (IL-6), tumor necrosis factor alpha (TNF-alpha), interleukin 8 (IL-8), and transforming growth factor alpha (TGF-alpha) after a single session dialysis in nine patients affected by end stage renal disease (ESRD). The same patients underwent a single session of online hemodiafiltration (OL-HDF) to evaluate possible differences in FGF23 and IL-6 levels. RESULTS: A significant reduction in FGF23 was observed with both Supra-HFR (p=0.001) and OL-HDF. As for TNF-alpha and TGF-alpha, which were measured using Supra-HFR only, their percentage values were significantly lower at the end of dialysis than at the start (p=0.0028 and p=0.03, respectively). This did not change with post-dialysis rebound. Supra-HFR was found to have no effect on IL-6 and IL-8. Interestingly, the removal rate for FGF23 and IL-6 was similar to that observed with OL-HDF. CONCLUSION: Supra-HFR was not superior to OL-HDF, with suboptimal convective volume in the removal of the molecules tested, especially FGF23, which is considered a large middle molecular weight uremic toxin.


Assuntos
Hemodiafiltração , Soluções para Hemodiálise , Citocinas , Fatores de Crescimento de Fibroblastos , Hemodiafiltração/métodos , Humanos , Interleucina-6 , Interleucina-8 , Fator de Crescimento Transformador alfa , Fator de Necrose Tumoral alfa , Toxinas Urêmicas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA