Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.256
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
EuroIntervention ; 20(9): 579-590, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726714

RESUMO

BACKGROUND: Data on the performance of the latest-generation SAPIEN 3 Ultra RESILIA (S3UR) valve in patients who undergo transcatheter aortic valve replacement (TAVR) are scarce. AIMS: We aimed to assess the clinical outcomes, including valve performance, of the S3UR. METHODS: Registry data of 618 consecutive patients with S3UR and of a historical pooled cohort of 8,750 patients who had a SAPIEN 3 (S3) valve and underwent TAVR were collected. The clinical outcomes and haemodynamics, including patient-prosthesis mismatch (PPM), were compared between the 2 groups and in a propensity-matched cohort. RESULTS: The incidence of in-hospital death, vascular complications, and new pacemaker implantation was similar between the S3UR and the S3 groups (allp>0.05). However, both groups showed significant differences in the degrees of paravalvular leakage (PVL) (none-trivial: 87.0% vs 78.5%, mild: 12.5% vs 20.5%, ≥moderate: 0.5% vs 1.1%; p<0.001) and the incidence of PPM (none: 94.3% vs 85.1%, moderate: 5.2% vs 12.8%, severe: 0.5% vs 2.0%; p<0.001). The prevalence of a mean pressure gradient ≥20 mmHg was significantly lower in the S3UR group (1.6% vs 6.2%; p<0.001). Better haemodynamics were observed with the smaller 20 mm and 23 mm S3UR valves. The results were consistent in a matched cohort of patients with S3UR and with S3 (n=618 patients/group). CONCLUSIONS: The S3UR has equivalent procedural complications to the S3 but with lower rates of PVL and significantly better valve performance. The better valve performance of the S3UR, particularly in smaller valve sizes, overcomes the remaining issue of balloon-expandable valves after TAVR.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Feminino , Masculino , Idoso de 80 Anos ou mais , Idoso , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Desenho de Prótese , Hemodinâmica , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Mortalidade Hospitalar
2.
EuroIntervention ; 20(9): 536-550, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726720

RESUMO

The identification and management of patients at high bleeding risk (HBR) undergoing transcatheter aortic valve implantation (TAVI) are of major importance, but the lack of standardised definitions is challenging for trial design, data interpretation, and clinical decision-making. The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) is a collaboration among leading research organisations, regulatory authorities, and physician-scientists from Europe, the USA, and Asia, with a major focus on TAVI-related bleeding. VARC-HBR is an initiative of the CERC (Cardiovascular European Research Center), aiming to develop a consensus definition of TAVI patients at HBR, based on a systematic review of the available evidence, to provide consistency for future clinical trials, clinical decision-making, and regulatory review. This document represents the first pragmatic approach to a consistent definition of HBR evaluating the safety and effectiveness of procedures, devices and drug regimens for patients undergoing TAVI..


Assuntos
Consenso , Hemorragia , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Hemorragia/etiologia , Medição de Risco , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia
3.
EuroIntervention ; 20(9): 591-601, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726722

RESUMO

BACKGROUND: Little is known about the occurrence of subclinical new-onset atrial fibrillation (NOAF) after transcatheter aortic valve implantation (TAVI). AIMS: We aimed to evaluate the incidence, predictors, and clinical impact of subclinical NOAF after TAVI. METHODS: This was a multicentre study, including patients with aortic stenosis (AS) and no previous atrial fibrillation undergoing TAVI, with continuous ambulatory electrocardiogram (AECG) monitoring after TAVI. RESULTS: A total of 700 patients (79±8 years, 49% female, Society of Thoracic Surgeons score 2.9% [1.9-4.0]) undergoing transarterial TAVI were included (85% balloon-expandable valves). AECG was started 1 (0-1) day after TAVI (monitoring time: 14121314 days). NOAF was detected in 49 patients (7%), with a median duration of 185 (43-421) minutes (atrial fibrillation burden of 0.7% [0.3-2.8]). Anticoagulation was started in 25 NOAF patients (51%). No differences were found in baseline or procedural characteristics, except for a higher AS severity in the NOAF group (peak gradient: no NOAF: 71.9±23.5 mmHg vs NOAF: 85.2±23.8 mmHg; p=0.024; mean gradient: no NOAF: 44.4±14.7 mmHg vs NOAF: 53.8±16.8 mmHg; p=0.004). In the multivariable analysis, the baseline mean transaortic gradient was associated with a higher risk of NOAF after TAVI (odds ratio 1.04, 95% confidence interval: 1.01-1.06 for each mmHg; p=0.006). There were no differences between groups in all-cause mortality (no NOAF: 4.7% vs NOAF: 0%; p=0.122), stroke (no NOAF: 1.4% vs NOAF: 2.0%; p=0.723), or bleeding (no NOAF: 1.9% vs NOAF: 4.1%; p=0.288) from the 30-day to 1-year follow-up. CONCLUSIONS: NOAF detected with AECG occurred in 7% of TAVI recipients and was associated with a higher AS severity. NOAF detection determined the start of anticoagulation therapy in about half of the patients, and it was not associated with an increased risk of clinical events at 1-year follow-up.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Eletrocardiografia Ambulatorial , Substituição da Valva Aórtica Transcateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Estenose da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Eletrocardiografia Ambulatorial/métodos , Fatores de Risco , Resultado do Tratamento
4.
Port J Card Thorac Vasc Surg ; 31(1): 12-16, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38743522

RESUMO

There has been a worldwide rapid adoption of transcatheter aortic valve replacement (TAVR) as an alternative to surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis. Currently, more TAVR explants with SAVRs are performed than TAVR-in TAV. TAVR explantation is a technically hazardous procedure mainly due to significant aortic neo-endothelialization which incorporates the TAVR valve. Surgical techniques for TAVR explantation are not well established and surgeon experience at present is limited. In this manuscript, we describe our technique for surgical explantation of transcatheter aortic bioprosthesis. Familiarity with the procedure and its clinical implications is essential for all cardiac surgeons.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Remoção de Dispositivo , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Remoção de Dispositivo/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Valva Aórtica/cirurgia , Valva Aórtica/patologia
5.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38691562

RESUMO

AIMS: We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. METHODS AND RESULTS: Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (<4 mm at 2 mm below the MS) was a significant independent predictor of post-procedural conduction disturbance (adjOR 7.387, 95% CI: 2.003-27.244, P = 0.003). CONCLUSION: Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Septo Interventricular , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Septo Interventricular/diagnóstico por imagem , Idoso de 80 Anos ou mais , Fatores de Risco , Idoso , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/diagnóstico por imagem , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/diagnóstico por imagem , Resultado do Tratamento , Valor Preditivo dos Testes , Medição de Risco , Índice de Gravidade de Doença , Estudos Retrospectivos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Tomografia Computadorizada por Raios X , Potenciais de Ação
6.
Ann Biomed Eng ; 52(6): 1554-1567, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38589731

RESUMO

Catheter reaction forces during transcatheter valve replacement (TAVR) may result in injury to the vessel or plaque rupture, triggering distal embolization or thrombosis. In vitro test methods represent the arterial wall using synthetic proxies to determine catheter reaction forces during tracking, but whether they can account for reaction forces within the compliant aortic wall tissue in vivo is unknown. Moreover, the role of plaque inclusions is not well understood. Computational approaches have predicted the impact of TAVR positioning, migration, and leaflet distortion, but have not yet been applied to investigate aortic wall reaction forces and stresses during catheter tracking. In this study, we investigate the role that catheter design and aorta and plaque mechanical properties have on the risk of plaque rupture during TAVR catheter delivery. We report that, for trackability testing, a rigid test model provides a reasonable estimation of the peak reaction forces experienced during catheter tracking within compliant vessels. We investigated the risk of rupture of both the aortic tissue and calcified plaques. We report that there was no risk of diseased aortic tissue rupture based on an accepted aortic tissue stress threshold (4.2 MPa). However, we report that both the aortic and plaque tissue exceed a rupture stress threshold (300 kPa) with and without the presence of stiff and soft plaque inclusions. We also highlight the potential risks associated with shorter catheter tips during catheter tracking and demonstrate that increasing the contact surface will reduce peak contact pressures experienced in the tissue.


Assuntos
Modelos Cardiovasculares , Substituição da Valva Aórtica Transcateter , Substituição da Valva Aórtica Transcateter/efeitos adversos , Humanos , Aorta , Catéteres/efeitos adversos , Placa Aterosclerótica
7.
J Am Heart Assoc ; 13(9): e033846, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38639328

RESUMO

BACKGROUND: Next-day discharge (NDD) outcomes following uncomplicated self-expanding transcatheter aortic valve replacement have not been studied. Here, we compare readmission rates and clinical outcomes in NDD versus non-NDD transcatheter aortic valve replacement with Evolut. METHODS AND RESULTS: Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry patients (n=29 597) undergoing elective transcatheter aortic valve replacement with self-expanding supra-annular valves (Evolut R, PRO, and PRO+) from July 2019 to June 2021 were stratified by postprocedure length of stay: ≤1 day (NDD) versus >1 day (non-NDD). Propensity score matching was used to compare risk adjusted 30-day readmission rates and 1-year outcomes in NDD versus non-NDD, and multivariable regression to determine predictors of NDD and readmission. Between the first and last calendar quarter, the rate of NDD increased from 45.4% to 62.1% and median length of stay decreased from 2 days to 1. Propensity score matching produced relatively well-matched NDD and non-NDD cohorts (n=10 549 each). After matching, NDD was associated with lower 30-day readmission rates (6.3% versus 8.4%; P<0.001) and 1-year adverse outcomes (death, 7.0% versus 9.3%; life threatening/major bleeding, 1.6% versus 3.4%; new permanent pacemaker implantation/implantable cardioverter-defibrillator, 3.6 versus 11.0%; [all P<0.001]). Predictors of NDD included non-Hispanic ethnicity, preexisting permanent pacemaker implantation/implantable cardioverter-defibrillator, and previous surgical aortic valve replacement. CONCLUSIONS: Most patients undergoing uncomplicated self-expanding Evolut transcatheter aortic valve replacement are discharged the next day. This study found that NDD can be predicted from baseline patient characteristics and was associated with favorable 30-day and 1-year outcomes, including low rates of permanent pacemaker implantation and readmission.


Assuntos
Estenose da Valva Aórtica , Alta do Paciente , Readmissão do Paciente , Pontuação de Propensão , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/tendências , Readmissão do Paciente/estatística & dados numéricos , Readmissão do Paciente/tendências , Masculino , Feminino , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Idoso , Alta do Paciente/tendências , Sistema de Registros , Tempo de Internação/estatística & dados numéricos , Tempo de Internação/tendências , Fatores de Tempo , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento , Estados Unidos/epidemiologia , Fatores de Risco , Valva Aórtica/cirurgia , Estudos Retrospectivos , Desenho de Prótese , Medição de Risco
8.
J Am Heart Assoc ; 13(9): e032777, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38639357

RESUMO

BACKGROUND: A delayed and recurrent complete atrioventricular block (CAVB) is a life-threatening complication of transcatheter aortic valve replacement (TAVR). Post-TAVR evaluation may be important in predicting delayed and recurrent CAVB requiring permanent pacemaker implantation (PPI). The impact of new-onset right bundle-branch block (RBBB) after TAVR on PPI remains unknown. METHODS AND RESULTS: In total, 407 patients with aortic stenosis who underwent TAVR were included in this analysis. Intraprocedural CAVB was defined as CAVB that occurred during TAVR. A 12-lead ECG was evaluated at baseline, immediately after TAVR, on postoperative days 1 and 5, and according to the need to identify new-onset bundle-branch block (BBB) and CAVB after TAVR. Forty patients (9.8%) required PPI, 17 patients (4.2%) had persistent intraprocedural CAVB, and 23 (5.7%) had delayed or recurrent CAVB after TAVR. The rates of no new-onset BBB, new-onset left BBB, and new-onset RBBB were 65.1%, 26.8%, and 4.7%, respectively. Compared with patients without new-onset BBB and those with new-onset left BBB, the rate of PPI was higher in patients with new-onset RBBB (3.4% versus 5.6% versus 44.4%, P<0.0001). On post-TAVR evaluation in patients without persistent intraprocedural CAVB, the multivariate logistic regression analysis showed that new-onset RBBB was a statistically significant predictor of PPI compared with no new-onset BBB (odds ratio [OR], 18.0 [95% CI, 5.94-54.4]) in addition to the use of a self-expanding valve (OR, 2.97 [95% CI, 1.09-8.10]). CONCLUSIONS: Patients with new-onset RBBB after TAVR are at high risk for PPI.


Assuntos
Estenose da Valva Aórtica , Bloqueio de Ramo , Estimulação Cardíaca Artificial , Eletrocardiografia , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/diagnóstico , Estenose da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Idoso , Estimulação Cardíaca Artificial/efeitos adversos , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/fisiopatologia , Fatores de Risco , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Tempo , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Complicações Pós-Operatórias/diagnóstico , Recidiva
9.
J Cardiothorac Surg ; 19(1): 211, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38616249

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has become widely used in recent years, However, there is also an increasing need for removal of TAVR valves due to prosthetic valve dysfunction (PVD) and the development of infective endocarditis. Surgical aortic valve replacement (AVR) for these patients is risky due to the original patient background and anatomic conditions. Intuity rapid deployment aortic valve (Edwards Lifesciences, Irvine, CA) replacement would be useful for such high risk patients to prevent longer cardiac arrest time and obtain good hemodynamic results. However, there are few reports which present Intuity valve replacement after TAVR explantation. Herein, We report two cases in which we have achieved good hemodynamics with shorter cardiac arrest times by using a rapid deployment valve after TAVR explantation. CASE PRESENTATION: We present 2 cases of successful implantation of the Intuity rapid deployment valve after TAVR explantation. The 84- and 88-year-old female patients had previously received TAVR for severe aortic stenosis with SAPIEN XT (Edwards Lifesciences, Irvine, CA) and developed PVD during follow-up. The TAVR valve was removed carefully, then an Intuity valve was implanted with cardiac arrest times of 69 and 41 min. Both patients had good echocardiographic results with effective orifice area of 2.0 cm2 and 1.2 cm2 and mean trans-aortic plessure gradient of 9 mmHg and 15 mmHg respectively without aortic regurgitation. They were discharged without major complications. CONCLUSIONS: Surgical AVR using a rapid deployment valve is a useful alternative to sutured AVR after TAVR valve explantation. It allows for shorter cardiac arrest times and better postoperative hemodynamics without major complication.


Assuntos
Insuficiência da Valva Aórtica , Parada Cardíaca , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Remoção de Dispositivo
10.
JACC Cardiovasc Interv ; 17(8): 1007-1016, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38573257

RESUMO

BACKGROUND: Data on valve reintervention after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) are limited. OBJECTIVES: The authors compared the 5-year incidence of valve reintervention after self-expanding CoreValve/Evolut TAVR vs SAVR. METHODS: Pooled data from CoreValve and Evolut R/PRO (Medtronic) randomized trials and single-arm studies encompassed 5,925 TAVR (4,478 CoreValve and 1,447 Evolut R/PRO) and 1,832 SAVR patients. Reinterventions were categorized by indication, timing, and treatment. The cumulative incidence of reintervention was compared between TAVR vs SAVR, Evolut vs CoreValve, and Evolut vs SAVR. RESULTS: There were 99 reinterventions (80 TAVR and 19 SAVR). The cumulative incidence of reintervention through 5 years was higher with TAVR vs SAVR (2.2% vs 1.5%; P = 0.017), with differences observed early (≤1 year; adjusted subdistribution HR: 3.50; 95% CI: 1.53-8.02) but not from >1 to 5 years (adjusted subdistribution HR: 1.05; 95% CI: 0.48-2.28). The most common reason for reintervention was paravalvular regurgitation after TAVR and endocarditis after SAVR. Evolut had a significantly lower incidence of reintervention than CoreValve (0.9% vs 1.6%; P = 0.006) at 5 years with differences observed early (adjusted subdistribution HR: 0.30; 95% CI: 0.12-0.73) but not from >1 to 5 years (adjusted subdistribution HR: 0.61; 95% CI: 0.21-1.74). The 5-year incidence of reintervention was similar for Evolut vs SAVR (0.9% vs 1.5%; P = 0.41). CONCLUSIONS: A low incidence of reintervention was observed for CoreValve/Evolut R/PRO and SAVR through 5 years. Reintervention occurred most often at ≤1 year for TAVR and >1 year for SAVR. Most early reinterventions were with the first-generation CoreValve and managed percutaneously. Reinterventions were more common following CoreValve TAVR compared with Evolut TAVR or SAVR.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Complicações Pós-Operatórias , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Incidência , Retratamento
11.
Catheter Cardiovasc Interv ; 103(6): 1074-1077, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38577923

RESUMO

Transcatheter aortic valve implantation (TAVI) has traditionally been indicated for the treatment of aortic stenosis. However, in this case report, we describe a successful TAVI procedure in a 46-year-old male patient who had previously undergone David aortic valve-sparing aortic root replacement for type 1 aortic dissection. The patient presented with aortic valve insufficiency 4 years after the initial surgery and was subsequently treated with a 34 mm Medtronic CoreValve Evolut R prosthesis via TAVI. This case highlights the feasibility of TAVI as a viable treatment option for postoperative aortic valve insufficiency in patients with prior ascending aortic or aortic arch surgery.


Assuntos
Dissecção Aórtica , Insuficiência da Valva Aórtica , Valva Aórtica , Implante de Prótese Vascular , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Dissecção Aórtica/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/fisiopatologia , Pessoa de Meia-Idade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Desenho de Prótese , Prótese Vascular , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Aneurisma Aórtico/diagnóstico por imagem , Aortografia
12.
Catheter Cardiovasc Interv ; 103(6): 1004-1014, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38577939

RESUMO

INTRODUCTION: Bicuspid aortic valve (BAV) stenosis is a complex anatomical scenario for transcatheter aortic valve implantation (TAVI). Favorable short-term clinical outcomes have been reported with TAVI in this setting, but long-term data are scarce. METHODS: We retrospectively included, in a single-center registry, patients with BAV stenosis who underwent TAVI before 2020. We compared patients treated with self-expanding valves (SEV) versus balloon-expandable valves (BEV). The primary endpoint was a composite of all-cause mortality, stroke and need for aortic valve (AV) reintervention at 3 years. Secondary endpoints included each component of the primary endpoint, cardiovascular mortality, permanent pacemaker implantation (PPI) rate, mean gradient and ≥moderate paravalvular leak (PVL) rate. RESULTS: A total of 150 consecutive patients (SEV = 83, BEV = 67) were included. No significant differences were reported between SEV and BEV groups for the primary composite endpoint (SEV 35.9% vs. BEV 32%, p = 0.66), neither for clinical secondary endpoints (all-cause mortality SEV 28.1% vs. BEV 28%, p = 0.988; cardiovascular mortality SEV 14.1% vs. BEV 20%, p = 0.399; stroke SEV 12.5% vs. BEV 6%, p = 0.342; need for AV reintervention SEV 0% vs. BEV 0%; PPI SEV 28.1% vs. BEV 24%, p = 0.620). A lower mean gradient persisted up to 3 years in the SEV group (SEV 8.8 ± 3.8 mmHg vs. BEV 10.7 ± 3.2 mmHg, p = 0.063), while no significant difference was found in the rate of ≥ moderate PVL (SEV 3/30 vs. BEV 0/25, p = 0.242). CONCLUSIONS: In this single center registry, we observed favorable 3-year clinical outcomes in nonselected BAV patients treated with different generation devices, without significant differences between patients receiving SEV or BEV.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Doença da Válvula Aórtica Bicúspide , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Masculino , Feminino , Estudos Retrospectivos , Resultado do Tratamento , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Fatores de Tempo , Idoso , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Idoso de 80 Anos ou mais , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/anormalidades , Recuperação de Função Fisiológica , Hemodinâmica , Medição de Risco
13.
Catheter Cardiovasc Interv ; 103(6): 1069-1073, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38584521

RESUMO

An 86-year-old female with history of surgical aortic valve replacement presented with clinical signs of heart failure. Echocardiography revealed a reduction in left ventricular systolic function and severe bioprosthetic aortic valve dysfunction. This is the first reported case of valve-in-valve transcatheter aortic valve replacement with concomitant undermining iatrogenic coronary obstruction with radiofrequency needle procedure in a surgical bioprosthetic valve.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Doença Iatrogênica , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Ablação por Cateter/efeitos adversos , Falha de Prótese , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/terapia , Agulhas , Função Ventricular Esquerda , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Oclusão Coronária/terapia , Oclusão Coronária/fisiopatologia , Angiografia Coronária
14.
Catheter Cardiovasc Interv ; 103(6): 1015-1022, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38577931

RESUMO

BACKGROUND: Previous studies have documented a high rate of implantation success with the ACURATE neo2 valve, as well as a reduction in paravalvular leak (PVL) compared to its predecessor, the ACURATE neo. However, there are no studies that have reviewed and compared the long-term clinical and hemodynamic outcomes of these patients. AIMS: This study aimed to evaluate the results of the ACURATE neo transcatheter aortic valve in a real-world context, and to compare the results of the outcomes of both generations of this device (ACURATE neo and ACURATE neo2), with a specific focus on procedural success, safety, and long-term effectiveness. METHODS: A prospective study including all consecutive patients treated with the ACURATE neo device in seven hospitals was conducted (Clinical Trials Identification Number: NCT03846557). The primary endpoint consisted of a composite of adverse events, including mortality, aortic insufficiency, and other procedural complications. As the second-generation device (ACURATE neo2) replaced the ACURATE neo during the study period, hemodynamic and clinical results before admission, at 30 days, and at 1 year of follow-up were compared between the two generations. RESULTS: A total of 296 patients underwent transcatheter aortic valve implantation with the ACURATE device, with 178 patients receiving the ACURATE neo and 118 patients receiving the ACURATE neo2. In the overall population, the absence of device success occurred in 14.5%. The primary reason for the absence of device success was the presence of para-valvular regurgitation ≥ 2. There were no instances of coronary occlusions, valve embolization, annulus rupture, or procedural deaths. ACURATE neo2 was associated with a significantly higher device success rate (91.7% vs. 82%, p = 0.04), primarily due to a significantly lower rate of para-valvular regurgitation, which remained significant at 1 year. CONCLUSION: The use of ACURATE neo and neo2 transcatheter aortic valves is associated with satisfactory clinical results and an extremely low rate of complications. The ACURATE neo2 enables a significantly higher device success rate, primarily attributed to a significant reduction in the rate of PVL.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Complicações Pós-Operatórias , Estudos Prospectivos , Recuperação de Função Fisiológica , Fatores de Risco , Espanha , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
15.
JACC Cardiovasc Interv ; 17(8): 1020-1028, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38658116

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an effective and safe therapy for severe aortic stenosis. Rapid or fast pacing is required for implantation, which can be performed via a pre-existing cardiac implantable electric device (CIED). However, safety data on CIEDs for pacing in TAVR are missing. OBJECTIVES: The aim of this study was to elucidate procedural safety and feasibility of internal pacing with a CIED in TAVR. METHODS: Patients undergoing TAVR with a CIED were included in this analysis. Baseline characteristics, procedural details, and complications according to Valve Academic Research Consortium 3 (VARC-3) criteria after TAVR were compared between both groups. RESULTS: A total of 486 patients were included. Pacing was performed using a CIED in 150 patients and a transient pacemaker in 336 patients. No differences in technical success according to VARC-3 criteria or procedure duration occurred between the groups. The usage of transient pacers for pacing was associated with a significantly higher bleeding rate (bleeding type ≥2 according to VARC-3-criteria; 2.0% vs 13.1%; P < 0.01). Furthermore, impairment of the CIED appeared in 2.3% of patients after TAVR only in the group in which pacing was performed by a transient pacer, leading to surgical revision of the CIED in 1.3% of all patients when transient pacemakers were used. CONCLUSIONS: Internal pacing using a CIED is safe and feasible without differences of procedural time and technical success and might reduce bleeding rates. Furthermore, pacing using a CIED circumvents the risk of lead dislocation. Our data provide an urgent call for the use of a CIED for pacing during a TAVR procedure in general.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Estimulação Cardíaca Artificial , Estudos de Viabilidade , Hospitais com Alto Volume de Atendimentos , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Resultado do Tratamento , Fatores de Tempo , Idoso , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Estudos Retrospectivos , Índice de Gravidade de Doença , Medição de Risco
20.
J Cardiothorac Surg ; 19(1): 196, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600556

RESUMO

BACKGROUND: The transcarotid (TC) vascular access for transcatheter aortic valve implantation (TAVI) has emerged as the first-choice alternative to the transfemoral access, in patients unsuitable for the latter. The use of both the left and right common carotid arteries (CCAs) for TC-TAVI has been described, but the optimal side is subject to debate. We conducted this pilot study to compare the level of vessel tortuosity and plaque burden from either the left CCA to the aortic annulus, or the right CCA to the aortic annulus, considering them as surrogates for technical and procedural complexity. METHODS: Consecutive patients who underwent TC-TAVI between 2018 and 2021 in our institution were included. Using three-dimensional reconstruction, pre-TAVI neck and chest computed tomography angiography exams were reviewed to assess the tortuosity index (TI), sum of angles metric, as well as plaque burden, between each CCA and the aortic annulus. RESULTS: We included 46 patients who underwent TC-TAVI. No significant difference regarding the mean TIs between the left and right sides (respectively 1.20 and 1.19, p = 0.82), the mean sum of angles (left side: 396°, right side: 384°, p = 0.27), and arterial plaque burden (arterial plaque found in 30% of left CCAs and 45% of right CCAs, p = 0.19) was found. CONCLUSIONS: We found no convincing data favoring the use of one particular access side over the other one. The choice of the CCA side in TC-TAVI should to be made on a case-by-case basis, in a multidisciplinary fashion, and may also depend on the operators' experience.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Projetos Piloto , Artéria Carótida Primitiva/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA