Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Rapid Commun Mass Spectrom ; 34(20): e8888, 2020 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-32656937

RESUMO

RATIONALE: Succinylcholine has been increasingly used in the theft of animals. Because of the presence of residual levels of succinylcholine in poisoned animals, it is harmful for people to eat foods derived from these animals. Therefore, a method should be immediately established to determine succinylcholine and its metabolite in animal-derived foods. METHODS: A fast, highly sensitive method, combining solid-phase extraction (SPE) with ultra-performance liquid chromatography/electrospray ionization tandem mass spectrometry (UPLC/ESI-MS/MS), was developed for the determination of succinylcholine and its metabolite in animal-derived foods. The sample was initially extracted with heptafluorobutyric acid and then further cleaned up using an SPE cartridge. Succinylcholine and its metabolite were separated using acetonitrile: 0.1% formic acid in 5 mmol L-1 ammonium acetate as the mobile phase. Quantitative results were based on positive ion ESI multiple reaction monitoring mode. RESULTS: The results show good linearity over a wide range with correlation coefficients of determination of more than 0.998. Both the limits of detection of succinylcholine and succinylmonocholine are 0.2 µg kg-1 . The intra- and inter-day accuracies of the method are in the range 91.4%-104.6%, and the intra- and inter-day precisions are in the range 2.5%-6.6%. CONCLUSIONS: This method can be used for the determination of succinylcholine as an illicit drug in animal-derived foods. It was successfully applied to the identification and quantification of succinylcholine and succinylmonocholine in animal-derived foods collected from a local farmers market in Jilin Province of China.


Assuntos
Cromatografia Líquida/métodos , Contaminação de Alimentos/análise , Extração em Fase Sólida/métodos , Succinilcolina/análise , Espectrometria de Massas em Tandem/métodos , Animais , Calibragem , Galinhas , China , Cães , Análise de Alimentos/métodos , Limite de Detecção , Produtos da Carne/análise , Reprodutibilidade dos Testes , Succinilcolina/análogos & derivados , Succinilcolina/metabolismo
2.
Soft Matter ; 15(41): 8197-8200, 2019 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-31613305

RESUMO

A series of supramolecular assemblies based on multi-charged calixarene (SC4A), bis(p-calixarene) (BSC4A) and pillararene (CP5A) modified gold nanoparticles (AuNP) was constructed to realize colorimetric sensing of both succinylcholine (SuCh) and butyrylcholinesterase (BChE). With the high binding affinity of BSC4A and CP5A towards SuCh, BSC4A-AuNPs and CP5A-AuNPs could assemble with micromolar level SuCh as SuCh-BSC4A/CP5A-AuNPs. More interestingly, the enzymatic hydrolysis of SuCh by BChE could lead to the disassembly of SuCh-BSC4A/CP5A-AuNPs and provide a sensitive time-dependent color change from blue to red which could be observed by the naked eye and used to monitor BChE activity. As BChE activity is an important biomarker for diseases and poor health conditions, this novel supramolecular tandem colorimetric sensing strategy may have potential use for early diagnosis of diseases.


Assuntos
Butirilcolinesterase/análise , Calixarenos/química , Corantes/química , Ouro/química , Nanopartículas Metálicas/química , Técnicas Biossensoriais/métodos , Colorimetria , Concentração de Íons de Hidrogênio , Cinética , Succinilcolina/análise , Propriedades de Superfície
3.
Luminescence ; 33(2): 376-381, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29115039

RESUMO

Two simple and sensitive analytical assay methods using spectrophotometry and spectrofluorimetry techniques were developed for the estimation of succinylcholine chloride (SUC) in pharmaceutical preparations. The suggested methods are based on the formation of an ion pair complex formed between the drug and eosin Y spectrophotometrically (Method I), or the suppressive effect of succinylcholine on the native fluorescence property of eosin Y (Method II). The spectrophotometric method (Method I) involves measuring the absorbance of the complex between succinylcholine and eosin Y at 550 nm in Britton Robinson buffer of pH 3. However, the spectrofluorimetric method (Method II) involves measuring the quenching effect of the studied drug on the native fluorescence property of eosin Y at the same pH at 550 nm after excitation at 480 nm. The absorbance versus concentration of the drug is rectilinear over the range of 0.5 to 15 µg/ml. The formation constant was 3.5 × 104 and the Gibb's free energy change was -2.5 × 104  J/mol. In Method II, the relative fluorescence intensity was directly proportional to SUC concentration over the range of 0.05 to 1 µg/ml. The proposed methods allowed a successful application to the estimation of succinylcholine ampoules. An explanation of the reaction pathway was postulated.


Assuntos
Amarelo de Eosina-(YS)/química , Fármacos Neuromusculares Despolarizantes/análise , Espectrometria de Fluorescência/métodos , Espectrofotometria/métodos , Succinilcolina/análise , Formas de Dosagem , Fluorescência
4.
J Clin Anesth ; 35: 551-559, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27871592

RESUMO

STUDY OBJECTIVE: To assess the stability of pharmaceutical suxamethonium (succinylcholine) solution for injection by validated stability-indicating chromatographic method in vials stored at room temperature. METHODS: The chromatographic assay was achieved by using a detector wavelength set at 218 nm, a C18 column, and an isocratic mobile phase (100% of water) at a flow rate of 0.6 mL/min for 5 minutes. The method was validated according to the International Conference on Harmonization guidelines with respect to the stability-indicating capacity of the method including linearity, limits of detection and quantitation, precision, accuracy, system suitability, robustness, and forced degradations. RESULTS: Linearity was achieved in the concentration range of 5 to 40 mg/mL with a correlation coefficient higher than 0.999. The limits of detection and quantification were 0.8 and 0.9 mg/mL, respectively. The percentage relative standard deviation for intraday (1.3-1.7) and interday (0.1-2.0) precision was found to be less than 2.1%. Accuracy was assessed by the recovery test of suxamethonium from solution for injection (99.5%-101.2%). CONCLUSION: Storage of suxamethonium solution for injection vials at ambient temperature (22°C-26°C) for 17 days demonstrated that at least 95% of original suxamethonium concentration remained stable.


Assuntos
Cromatografia Líquida de Alta Pressão , Fármacos Neuromusculares Despolarizantes/análise , Succinilcolina/análise , Estabilidade de Medicamentos , Fármacos Neuromusculares Despolarizantes/química , Soluções Farmacêuticas , Reprodutibilidade dos Testes , Succinilcolina/química
5.
J Anal Toxicol ; 40(8): 608-616, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27474362

RESUMO

In healthcare settings drug diversion and impairment of physicians are major concerns requiring a rapid and efficient method for surveillance and detection. A Direct Analysis in Real Time ion source coupled to a JEOL AccuTOFTM time-of-flight mass spectrometer (DART-MS) method was developed to screen parenteral pharmaceutical formulations for potential drug diversion. Parenteral pharmaceutical formulations are also known as injectable formulations and are used with intravenous, subcutaneous, intramuscular and intra-articular administration. A library was created using the mass spectra data collected by a DART-MS operated in switching mode at 20, 60 and 90 V settings. This library contained 17 commonly encountered drugs in parenteral pharmaceutical formulations that included the surgical analgesic: fentanyl, hydromorphone and morphine; anesthetic: baclofen, bupivacaine, ketamine, midazolam, ropivacaine and succinylcholine; and a mixture of other drug classes: caffeine, clonidine, dexamethasone, ephedrine, heparin, methadone, oxytocin and phenylephrine. Randomly selected 200 de-identified parenteral pharmaceutical formulations containing one or more drugs were submitted for analysis to the FIRM Toxicology Laboratory at Virginia Commonwealth University Health and were screened using the DART-MS. The drug contents of the de-identified formulations were previously confirmed by a published high performance liquid chromatography (HPLC) method. The drugs in the formulations were rapidly and successfully identified using the generated library. The DART-MS and HPLC results were in complete agreement for all 200 parenteral pharmaceutical formulations.


Assuntos
Analgésicos/análise , Espectrometria de Massas/métodos , Soluções de Nutrição Parenteral/análise , Amidas/análise , Anestésicos/análise , Baclofeno/análise , Bupivacaína/análise , Cafeína/análise , Cromatografia Líquida de Alta Pressão , Clonidina/análise , Dexametasona/análise , Efedrina/análise , Fentanila/análise , Heparina/análise , Hidromorfona/análise , Ketamina/análise , Metadona/análise , Midazolam/análise , Morfina/análise , Ocitocina/análise , Fenilefrina/análise , Ropivacaina , Succinilcolina/análise
6.
Int J Legal Med ; 130(6): 1541-1545, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27179645

RESUMO

In emergency departments, intoxication with the muscle relaxant succinylcholine (SUX) often leads to a potentially lethal respiratory paralysis or other deleterious side effects. However, homicide cases with SUX poisoning are very rare because the toxic or lethal concentration ranges of SUX have not yet been determined. We described three uncommon homicide cases due to acute poisoning by darts contaminated with SUX. All the victims died quickly (less than 30 min) after being shot by an especially designed dart gun. Succinylmonocholine (SMC), a metabolite of SUX, was used as a marker to detect the latter. HPLC-MS/MS analysis demonstrated the presence of SUX in the droplet residues of the darts and SMC in the blood and urine in all cases. SMC concentrations of 0.45, 14.0, and 17.9 ng/ml were detected in the victims' blood and 259.0 ng/ml in the urine from the third case. The main pathological changes consisted of hemorrhage of the injured soft tissues, visceral congestion, severe pulmonary edema, and multifocal petechial hemorrhage of the heart and lungs. Taken together, the findings supported a diagnosis of fatal SUX poisoning. Futhermore, our study provided a reference for the lethal concentrations of SUX poisoning.


Assuntos
Homicídio , Fármacos Neuromusculares Despolarizantes/intoxicação , Succinilcolina/intoxicação , Adulto , Biomarcadores/sangue , Biomarcadores/urina , Cromatografia Líquida de Alta Pressão , Humanos , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Fármacos Neuromusculares Despolarizantes/análise , Succinilcolina/análogos & derivados , Succinilcolina/análise , Succinilcolina/sangue , Succinilcolina/urina , Ferimentos Perfurantes
7.
Ann Emerg Med ; 62(4): 380-387.e1, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23711878

RESUMO

STUDY OBJECTIVE: The aim of this study is to determine the content of 5 important emergency medical services (EMS) drugs after being stored at the recommended refrigerated temperature, room temperature, or in an emergency physician transport vehicle operating under real-world working conditions. METHODS: Adrenaline hydrochloride, cisatracurium besylate, lorazepam, methylergonovine maleate, and succinylcholine chloride were stored for 1 year under the 3 conditions. For each storage condition, samples of the drugs were taken after 1, 2, 3, and 4 weeks and after 2, 4, 6, 8, 10, and 12 months. For adrenaline hydrochloride, however, the samples were taken after 1, 2, 4, 6, 8, 10, and 12 months. The samples were analyzed with a validated high-performance liquid chromatography assay. A drug was considered stable if its content was above 90%. RESULTS: Adrenaline hydrochloride and methylergonovine maleate remained stable for 1 year at room temperature and in the emergency physician transport vehicle. At room temperature and in the emergency physician transport vehicle, lorazepam became unstable within 4 weeks. Succinylcholine chloride was stable for 2 months at room temperature and for 1 month in the emergency physician transport vehicle. Cisatracurium besylate became unstable within 4 months at room temperature. However, it remained stable for 4 months in the emergency physician transport vehicle. CONCLUSION: When stored at room temperature or in the emergency physician transport vehicle, lorazepam became unstable within weeks, whereas succinylcholine chloride and cisatracurium besylate became unstable within months. Adrenaline hydrochloride and methylergonovine maleate remained stable for several months, even under room temperature and emergency physician transport vehicle conditions. Thus, real-world EMS working conditions pose challenges for maintaining optimal efficacy of these important EMS drugs.


Assuntos
Estabilidade de Medicamentos , Temperatura , Ambulâncias , Atracúrio/análogos & derivados , Atracúrio/análise , Atracúrio/normas , Cromatografia Líquida de Alta Pressão , Armazenamento de Medicamentos/métodos , Armazenamento de Medicamentos/normas , Serviços Médicos de Emergência , Epinefrina/análise , Epinefrina/normas , Metilergonovina/análise , Metilergonovina/normas , Succinilcolina/análise , Succinilcolina/normas , Fatores de Tempo
8.
Fa Yi Xue Za Zhi ; 29(6): 451-3, 2013 Dec.
Artigo em Chinês | MEDLINE | ID: mdl-24665619

RESUMO

Abstract: Suxamethonium chloride is a depolarizing muscle relaxant used in general anesthesia. In overdose, it causes adverse reactions such as bradycardia, arrhythmia, cardiac arrest, and death. The article reviews the progress on testing methods of suxamethonium chloride such as infrared spectroscopy, chemical color reaction, chemical titration, enzyme electrode, chromatography and mass spectrometry.


Assuntos
Anestesia Geral , Arritmias Cardíacas/induzido quimicamente , Bradicardia/induzido quimicamente , Parada Cardíaca/induzido quimicamente , Fármacos Neuromusculares Despolarizantes/efeitos adversos , Succinilcolina/efeitos adversos , Técnicas Biossensoriais , Cromatografia , Overdose de Drogas , Humanos , Espectrometria de Massas , Fármacos Neuromusculares Despolarizantes/análise , Espectrofotometria Infravermelho , Succinilcolina/análise
9.
Forensic Sci Int ; 207(1-3): 84-90, 2011 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-20934283

RESUMO

Doubts concerning the applicability of succinylmonocholine (SMC) as a succinylcholine (SUX) marker have been issued. A comparative analysis of previously discussed tissues, i.e. brain, liver and kidney, was conducted to further elucidate this question by searching for diagnostically useful differences in analyte content in samples of SUX- versus non-SUX-associated fatalities. Furthermore, possible advantages of vitreous humor as a novel and promising target matrix for SUX analytics were assessed. Sample material of SUX-negative controls as well as the fatal SUX-intoxication was derived from frozen archive material and current autopsies. Samples were analyzed according to a modified protocol of a previously published and validated method employing ion-pairing solid-phase extraction and subsequent HPLC-MS/MS analysis. Standard addition was employed for quantification as well as an estimation of the analytical limits of the method. In all tested matrices, the method was proven to be sufficiently sensitive for the intended application. No indication of native SMC was found in controls of fresh tissues, nor in fresh or frozen vitreous humor. However, most of the samples were found to be positive for a previously reported interference with SMC's main ion transition, thereby falsely suggesting an SMC content of up to 139 ng/g, 126 ng/g, 165 ng/g and 93 ng/ml in brain, liver, kidney and vitreous humor, respectively. Contrasting the results for fresh sample material, SMC was detectable in some of the initially non-putrefied liver samples after long-term storage, as well as in massively decomposed SUX-negative control bodies. In this context, a microbial origin of the analyte may be assumed. All tissues as well as the vitreous humor of the fatal SUX-intoxication were negative for SUX and SMC. Just like serum, tissue and vitreous humor samples therefore do not allow a reliable diagnosis of a SUX-intoxication: in tissues this is due to the pronounced instability of both target analytes in these esterase-containing matrices, for vitreous humor an additional reason could be their insufficient incorporation into this medium.


Assuntos
Fármacos Neuromusculares Despolarizantes/intoxicação , Succinilcolina/análogos & derivados , Succinilcolina/intoxicação , Biomarcadores/análise , Química Encefálica , Estudos de Casos e Controles , Toxicologia Forense , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Rim/química , Fígado/química , Fármacos Neuromusculares Despolarizantes/análise , Intoxicação/diagnóstico , Succinilcolina/análise , Corpo Vítreo/química
10.
J Pharm Biomed Anal ; 49(2): 333-7, 2009 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-19121913

RESUMO

A simple method based on capillary electrophoresis with a capacitively coupled contactless conductivity detector (CE-C(4)D) was developed for the determination of suxamethonium (SUX) in a pharmaceutical formulation. A hydro-organic mixture, consisting of 100mM Tris-acetate buffer at pH 4.2 and acetonitrile (90:10, v/v), was selected as background electrolyte (BGE). The applied voltage was 30kV, and the sample injection was performed in the hydrodynamic mode. All analyses were carried out in a fused silica capillary with an internal diameter of 50 microm and a total length of 64.5cm. Under these conditions, a complete separation between SUX, sodium ions and the main degradation products (choline) was achieved in less than 4min. The presence of acetonitrile in the BGE allowed a reduction of SUX adsorption on the capillary wall. The CE-C(4)D method was validated, and trueness values between 98.8% and 101.1% were obtained with repeatability and intermediate precision values of 0.7-1.3% and 1.2-1.6%, respectively. Therefore, this method was found appropriate for controlling pharmaceutical formulations containing suxamethonium and degradation products.


Assuntos
Condutividade Elétrica , Fármacos Neuromusculares Despolarizantes/química , Fármacos Neuromusculares Despolarizantes/farmacocinética , Succinilcolina/química , Succinilcolina/farmacocinética , Ácido Acético/química , Acetonitrilas/química , Adsorção , Soluções Tampão , Química Farmacêutica/métodos , Colina/isolamento & purificação , Eletricidade , Eletrólitos/química , Eletroforese Capilar/instrumentação , Eletroforese Capilar/métodos , Concentração de Íons de Hidrogênio , Íons/isolamento & purificação , Estrutura Molecular , Fármacos Neuromusculares Despolarizantes/análise , Padrões de Referência , Reprodutibilidade dos Testes , Succinilcolina/análise , Temperatura , Fatores de Tempo , Trometamina/química
11.
Acta Pol Pharm ; 65(3): 295-301, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18646548

RESUMO

Cross-polarization (CP) magic angle spinning (MAS) 13C NMR spectroscopy has become a routine tool in pharmacy, employed to identify and characterize drugs in the solid phase. 13C CPMAS NMR spectra were recorded for solid hydrocortisone 21-hemisuccinate and suxamethonium chloride. White crystalline substances, such as these two drugs, can be easily distinguished; and solid-state 13NMR spectra of remarkably good quality are obtained in less than half an hour. 13C CPMAS chemical shifts for solid suxamethonium chloride and hydrocortisone sodium hemisuccinate are given, as well as cross-polarization kinetic parameters for suxamethonium chloride.


Assuntos
Hidrocortisona/análogos & derivados , Espectroscopia de Ressonância Magnética/métodos , Succinilcolina/análise , Anti-Inflamatórios/análise , Isótopos de Carbono , Hidrocortisona/análise , Fármacos Neuromusculares Despolarizantes/análise
14.
J Anal Toxicol ; 26(1): 29-34, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-11890177

RESUMO

Quaternary nitrogen muscle relaxants pancuronium, rocuronium, vecuronium, gallamine, suxamethonium, mivacurium, and atracurium and its metabolites were extracted from whole blood and other biological fluids and tissues by using a solid-phase extraction procedure. The extracts were examined by using high-performance liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS). The drugs were separated on a ODS column in a gradient of ammonium acetate buffer (pH 5.0) and acetonitrile. Full-scan mass spectra of the compounds showed molecular ions, and MS-MS spectra showed fragments typical of the particular compounds. LC-ESI-MS allowed an unequivocal differentiation of all muscle relaxants involved. The method was applied in a case of rocuronium and suxamethonium administration in a Caesarian section and in a case of intoxication by pancuronium injection. In both cases, the administered drugs could be detected and identified in the supplied samples.


Assuntos
Relaxantes Musculares Centrais/análise , Compostos de Nitrogênio/análise , Adulto , Androstanóis/análise , Androstanóis/intoxicação , Bile/química , Líquidos Corporais/química , Soluções Tampão , Feminino , Medicina Legal , Humanos , Indicadores e Reagentes , Fígado/química , Masculino , Espectrometria de Massas , Relaxantes Musculares Centrais/sangue , Relaxantes Musculares Centrais/urina , Fármacos Neuromusculares Despolarizantes/análise , Fármacos Neuromusculares não Despolarizantes/análise , Fármacos Neuromusculares não Despolarizantes/intoxicação , Compostos de Nitrogênio/sangue , Compostos de Nitrogênio/urina , Pancurônio/análise , Pancurônio/intoxicação , Intoxicação/diagnóstico , Gravidez , Padrões de Referência , Rocurônio , Espectrometria de Massas por Ionização por Electrospray , Succinilcolina/análise , Succinilcolina/intoxicação
15.
Analyst ; 121(11): 1695-8, 1996 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8952457

RESUMO

The neuromuscular blocking agent, succinylcholine, and the neurotransmitter, acetylcholine, have been determined in pharmaceutical preparations utilizing a sensing unit comprised of a rotating bioreactor and an amperometric detector. The bioreactor consisted of a rotating disk made of Teflon (1 cm id) with cholinesterase (EC 3.1.1.8) and choline oxidase (EC 1.1.3.17) co-immobilized on the top surface of the disk. Amperometric detection of H2O2 and initial rate measurements were employed for quantification.


Assuntos
Acetilcolina/análise , Succinilcolina/análise , Oxirredutases do Álcool , Reatores Biológicos , Colinesterases , Enzimas Imobilizadas , Preparações Farmacêuticas/análise
16.
J Chromatogr A ; 739(1-2): 351-7, 1996 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-8765854

RESUMO

Choline is a primary degradation product of succinylcholine chloride. Determination of low concentration choline in succinylcholine chloride bulk drug and formulation is a challenge, due to the lack of sensitive detection methods. A reversed-phase separation method with postcolumn suppression conductivity detection is described for the determination of choline. Hexanesulfonic acid is employed as an ion-pair reagent in the mobile phase, which allows the accomplishment of both reversed-phase separation and a sensitive conductivity detection. Detection sensitivity is significantly enhanced by passing the mobile phase through a postcolumn cation suppressor, where hexanesulfonic acid is removed and the background conductance is reduced. This method is simple and sensitive. No sample derivatization procedure is required. The detection limit for choline is about 10 pmol.


Assuntos
Colina/análise , Cromatografia Líquida de Alta Pressão/métodos , Preparações Farmacêuticas/análise , Succinilcolina/análise , Colina/química , Cromatografia Líquida de Alta Pressão/estatística & dados numéricos , Estabilidade de Medicamentos , Condutividade Elétrica , Sensibilidade e Especificidade , Succinilcolina/química , Tecnologia Farmacêutica
17.
Rev. cuba. farm ; 29(2): 94-100, jul.-dic. 1995. tab, ilus
Artigo em Espanhol | LILACS | ID: lil-168821

RESUMO

La succinilcolina es un agente de bloqueo neuromuscular de tipo despolarizante, ampliamente utilizada en cirugia como relajente muscular. Se expone el desarrollo tecnologico, el estudio de estabilidad y microbiologico del inyectable, asi como las condiciones de almacenamiento y caducidad del producto


Assuntos
Cromatografia Líquida de Alta Pressão , Vias de Administração de Medicamentos , Avaliação de Medicamentos , Injeções , Succinilcolina/análise
18.
J Pharm Biomed Anal ; 12(9): 1083-90, 1994 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-7803556

RESUMO

A simple and reliable method of assaying succinylcholine chloride, oxtriphylline (choline theophyllinate) and acetycholine chloride in pharmaceutical preparations, based on conversion to choline, is provided by combination of chemiluminometry of choline and dot-blot technique. Recoveries of 102 and 97% for choline chloride in Quelicin injection and Choledyl 200 tablets matrices, respectively, and of 99% for acetylcholine chloride in Miochol solution matrix could be achieved using simple choline chloride standards in phosphate buffer pH 8.6. Accordingly, matrix-matched standards were found redundant. Favourable results obtained in preparations-matched media including limits of detection of 37-39 pmol microliters-1 of choline chloride, together with accuracies of 0-2% and RSDs ranging from 4 to 7% are the further evidence of the suitability of the method.


Assuntos
Acetilcolina/análise , Broncodilatadores/análise , Colina , Colina/análogos & derivados , Preparações Farmacêuticas/análise , Succinilcolina/análise , Teofilina/análogos & derivados , Colina/análise , Immunoblotting , Medições Luminescentes , Preparações Farmacêuticas/normas , Comprimidos , Teofilina/análise
19.
Voen Med Zh ; (7): 62-4, 1992 Jul.
Artigo em Russo | MEDLINE | ID: mdl-1455786

RESUMO

In aqueous solutions dithylinum decomposes with formation iodine, choline, succinic acid and its monoether. The rate of decomposition depends on the conditions of storage, and also upon the concentration and ion force of solution, existence of ion metals and some other factors. The article proposes methods for identification and quantitative analysis of dithylinum and the products of its hydrolysis. The requirements imposed for storage or transportation of dithylinum solutions: not frost and temperature level not higher than 5 degrees C.


Assuntos
Succinilcolina/química , Química Farmacêutica , Estabilidade de Medicamentos , Armazenamento de Medicamentos , Controle de Qualidade , Soluções , Succinilcolina/análise
20.
Anaesth Intensive Care ; 20(2): 143-6, 1992 May.
Artigo em Inglês | MEDLINE | ID: mdl-1595846

RESUMO

Intradermal testing and RIA testing for specific IgE antibodies to neuromuscular blocking drugs (NMBDs) were performed in patients referred to an Anaesthetic Allergy Clinic. Six patients were initially investigated four to 29 years after clinical anaphylaxis during anaesthesia and two of these patients and sixteen others were investigated by intradermal testing on two occasions at least four years apart. Seven patients had RIA tests for NMBD-specific IgE antibodies on two occasions at the time of skin testing. In all but two patients the evidence for drug-specific antibodies persisted 4-29 years after the reactions. In one patient all tests became negative and in another the skin test became negative but the positive RIA persisted. Evidence of antibodies to NMBDs persisted in 21 of 22 patients who had had anaphylactic reactions to these drugs during anaesthesia. In the absence of evidence of allergy diminishing with time in the majority of patients it would seem wise to avoid drugs responsible for reactions for the rest of the patient's life.


Assuntos
Hipersensibilidade a Drogas/diagnóstico , Bloqueadores Neuromusculares/efeitos adversos , Alcurônio/efeitos adversos , Alcurônio/análise , Anafilaxia/diagnóstico , Anafilaxia/metabolismo , Anticorpos/análise , Compostos de Decametônio/efeitos adversos , Compostos de Decametônio/análise , Hipersensibilidade a Drogas/metabolismo , Trietiodeto de Galamina/efeitos adversos , Trietiodeto de Galamina/análise , Humanos , Imunoglobulina E/análise , Bloqueadores Neuromusculares/análise , Radioimunoensaio , Testes Cutâneos , Succinilcolina/efeitos adversos , Succinilcolina/análise , Fatores de Tempo , Tubocurarina/efeitos adversos , Tubocurarina/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA