Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
J Laryngol Otol ; 134(8): 735-738, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32718361

RESUMO

BACKGROUND: Coronavirus disease 2019 is an international pandemic. One of the cardinal features is acute respiratory distress syndrome, and proning has been identified as beneficial for a subset of patients. However, proning is associated with pressure-related side effects, including injury to the nose and face. METHOD: This paper describes a pressure-relieving technique using surgical scrub sponges. This technique was derived based on previous methods used in patients following rhinectomy. CONCLUSION: The increased use of prone ventilation has resulted in a number of referrals to the ENT team with concerns regarding nasal pressure damage. The described technique, which is straightforward and uses readily available materials, has proven effective in relieving pressure in a small number of patients.


Assuntos
Infecções por Coronavirus/prevenção & controle , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Pressão/efeitos adversos , Decúbito Ventral/fisiologia , Respiração Artificial/métodos , Tampões de Gaze Cirúrgicos/normas , Betacoronavirus/isolamento & purificação , COVID-19 , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/transmissão , Infecções por Coronavirus/virologia , Desenho de Equipamento/métodos , Traumatismos Faciais/prevenção & controle , Humanos , Nariz/lesões , Nariz/cirurgia , Posicionamento do Paciente/métodos , Pneumonia Viral/epidemiologia , Pneumonia Viral/transmissão , Pneumonia Viral/virologia , SARS-CoV-2
2.
Crit Care ; 24(1): 458, 2020 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-32703235

RESUMO

BACKGROUND: Chlorhexidine-gluconate (CHG) impregnated dressings may prevent catheter-related bloodstream infections (CRBSI). Chlorhexidine-impregnated sponge dressings (sponge-dress) and gel dressings (gel-dress) have never been directly compared. We used the data collected for two randomized-controlled trials to perform a comparison between sponge-dress and gel-dress. METHODS: Adult critically ill patients who required short-term central venous or arterial catheter insertion were recruited. Our main analysis included only patients with CHG-impregnated dressings. The effect of gel-dress (versus sponge-dress) on major catheter-related infections (MCRI) and CRBSI was estimated using multivariate marginal Cox models. The comparative risks of dressing disruption and contact dermatitis were evaluated using logistic mix models for clustered data. An explanatory analysis compared gel-dress with standard dressings using either CHG skin disinfection or povidone iodine skin disinfection. RESULTS: A total of 3483 patients and 7941 catheters were observed in 16 intensive care units. Sponge-dress and gel-dress were utilized for 1953 and 2108 catheters, respectively. After adjustment for confounders, gel-dress showed similar risk for MCRI compared to sponge-dress (HR 0.80, 95% CI 0.28-2.31, p = 0.68) and CRBSI (HR 1.13, 95% CI 0.34-3.70, p = 0.85), less dressing disruptions (OR 0.72, 95% CI 0.60-0.86, p < 0.001), and more contact dermatitis (OR 3.60, 95% CI 2.51-5.15, p < 0.01). However, gel-dress increased the risk of contact dermatitis only if CHG was used for skin antisepsis (OR 1.94, 95% CI 1.38-2.71, p < 0.01). CONCLUSIONS: We described a similar infection risk for gel-dress and sponge-dress. Gel-dress showed fewer dressing disruptions. Concomitant use of CHG for skin disinfection and CHG-impregnated dressing may significantly increase contact dermatitis. TRIALS REGISTRATION: These studies were registered within ClinicalTrials.gov (numbers NCT01189682 and NCT00417235 ).


Assuntos
Bandagens/normas , Clorexidina/farmacologia , Tampões de Gaze Cirúrgicos/normas , Fatores de Tempo , Adulto , Animais , Infecções Relacionadas a Cateter/prevenção & controle , Cateterismo Venoso Central/instrumentação , Cateterismo Venoso Central/métodos , Cateterismo Venoso Central/normas , Cateterismo Periférico/instrumentação , Cateterismo Periférico/métodos , Cateterismo Periférico/normas , Clorexidina/administração & dosagem , Clorexidina/uso terapêutico , Estado Terminal/enfermagem , Desinfecção/instrumentação , Desinfecção/normas , Desinfecção/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
3.
Rev. bras. cir. plást ; 31(4): 583-585, 2016. ilus
Artigo em Inglês, Português | LILACS | ID: biblio-827468

RESUMO

The retained surgical item in patients after closure of the wound is a situation that although rare is preventable and requires specific care such as institutional protocols for prevention. We report a case of removal of an already encapsulated pads by fibrin tissue (textiloma) from a patient six years after an abdominoplasty, which formed a palpable mass in her abdomen. The retained surgical items lead to variable symptoms such as palpable masses, compressions, non-absorptive loss and, sometimes, severe complications. The diversity of manifestations combined with their few frequency, most of the times, lead to underdiagnosis. Treatment should be individualized for each case, although in case of symptoms removal is indicated in most cases. Surgical removal is associated with complications as longer as objects remain in patient's body.


A permanência de corpos estranhos em pacientes após o fechamento da ferida operatória é uma situação que, embora rara, é evitável e demanda cuidados específicos como protocolos institucionais de prevenção. O caso relata a retirada de uma compressa já encapsulada por tecido de fibrina (textiloma) de uma paciente seis anos após abdominoplastia, formando uma massa palpável em seu abdômen. A permanência desses itens cirúrgicos leva a sintomas variáveis como massas palpáveis, compressões, síndromes disabsortivas e, algumas vezes, graves complicações. A diversidade de manifestações combinada a sua pouca frequência levam, muitas vezes, ao subdiagnóstico. O tratamento deve ser individualizado para cada caso, embora na presença de sintomas a retirada é indicada na grande maioria das vezes. A cirurgia de retirada está mais associada a complicações quanto maior tempo de permanência dos objetos no corpo do paciente.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , História do Século XXI , Pacientes , Complicações Pós-Operatórias , Instrumentos Cirúrgicos , Fibrina , Tampões de Gaze Cirúrgicos , Seroma , Abdome , Abdominoplastia , Corpos Estranhos , Pacientes/psicologia , Complicações Pós-Operatórias/cirurgia , Complicações Pós-Operatórias/patologia , Instrumentos Cirúrgicos/efeitos adversos , Instrumentos Cirúrgicos/normas , Fibrina/análise , Fibrina/efeitos adversos , Tampões de Gaze Cirúrgicos/efeitos adversos , Tampões de Gaze Cirúrgicos/normas , Seroma/cirurgia , Seroma/complicações , Abdominoplastia/métodos , Corpos Estranhos/cirurgia , Corpos Estranhos/complicações , Corpos Estranhos/patologia , Abdome/cirurgia
4.
World Neurosurg ; 73(4): 417-9, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20849804

RESUMO

BACKGROUND: Various treatment modalities are available for treatment of cystic lesions of the brainstem. However, cyst refilling and recurrences are very common. This article describes a young boy who presented with an intra-axial brainstem cyst following radiation for a pilocytic astrocytoma. METHODS: The cyst was decompressed surgically once but it soon refilled. The use of a novel customized synthetic sponge acting as a shunt for the treatment of a cystic brainstem lesion is discussed. The sponge was fashioned like a dumbbell and inserted across the fenestration in the cyst wall. RESULTS: The dumbbell design made it self-retaining. The characteristics of the sponge permitted continuous capillary drainage, with a low risk of occlusion. There was a dramatic decrease in the cyst size on follow-up scans, with resolution of clinical deficits. CONCLUSIONS: A customized sponge shunt can serve as an easily available and effective internal shunt for intra-axial craniospinal cysts.


Assuntos
Tronco Encefálico/cirurgia , Cistos do Sistema Nervoso Central/cirurgia , Derivações do Líquido Cefalorraquidiano/instrumentação , Procedimentos Neurocirúrgicos/instrumentação , Tampões de Gaze Cirúrgicos/tendências , Adolescente , Materiais Biocompatíveis/uso terapêutico , Tronco Encefálico/patologia , Tronco Encefálico/fisiopatologia , Cistos do Sistema Nervoso Central/patologia , Cistos do Sistema Nervoso Central/fisiopatologia , Derivações do Líquido Cefalorraquidiano/métodos , Humanos , Masculino , Procedimentos Neurocirúrgicos/métodos , Poliuretanos/uso terapêutico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/prevenção & controle , Prevenção Secundária , Tampões de Gaze Cirúrgicos/normas , Resultado do Tratamento
5.
Oral Microbiol Immunol ; 24(3): 231-5, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19416453

RESUMO

INTRODUCTION: To facilitate diagnoses, this study determined the efficacy of commercial oral fluid collection devices for their ability to recover three human immunoglobulin isotypes; immunoglobulin A (IgA), IgG, and IgM. METHODS: The sandwich enzyme-linked immunosorbent assay was used to determine antibody recovery from the following devices: (i) OraSure oral specimen collection device, (ii) saliva*sampler, (iii) ORALscreen collector, (iv) Dri-Angle, (v) no. 2 cotton roll, (vi) all-gauze sponges device, and (vii) DentaSwabs. For each isotype tested, the recovered eluate was compared with the concentration applied to the device. The performance of each device was determined at various antibody concentrations. RESULTS: Recovery of IgA from the saliva*sampler, ORALscreen collector, Dri-Angle and cotton roll was comparable to that seeded onto the device. When compared with the seeded IgG concentration, the mean concentration of antibody recovered by each product differed by approximately +/- 9 ng/ml. The average amount of IgM recovered by the cotton roll and all-gauze sponges device was approximately 29 and 39 ng/ml, respectively, less (P < 0.0001) than that seeded on the device. For all isotypes tested, the amount of antibody recovered from the device was dependent on the initial seeding concentration. CONCLUSION: Collectively, these data suggest that the product used for specimen collection can affect retrieval of antibodies and potentially confound patient diagnosis.


Assuntos
Anticorpos/análise , Isotipos de Imunoglobulinas/análise , Saliva/imunologia , Manejo de Espécimes/instrumentação , Celulose/química , Ensaio de Imunoadsorção Enzimática , Desenho de Equipamento , Humanos , Imunoglobulina A Secretora/análise , Imunoglobulina G/análise , Imunoglobulina M/análise , Poliestirenos/química , Manejo de Espécimes/normas , Tampões de Gaze Cirúrgicos/normas , Tampões Cirúrgicos/normas
6.
J Biomed Mater Res A ; 85(3): 699-706, 2008 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-17876777

RESUMO

The relationship between tissue reactions to a subcutaneously implanted glucose sensor and the function of the sensor was evaluated over a period of 4-weeks using tubular, porous polyvinyl alcohol (PVA) sponges implanted subcutaneously in rats. The PVA sponges were used as scaffolds in which the foreign body response could develop. Coil-type glucose sensors were then placed in the center of the PVA sponges and tested on day 3, and weekly thereafter. In the first approach, the sensors were placed in the sponges still implanted in the rats and tested. In vivo glucose sensor sensitivity peaked at day 7 and steadily decreased until day 35. In the second approach, the sensors were placed in the explanted sponges and then tested. This test showed no sensor function after day 7, indicating that functional blood vessels are critical in maintaining any function whatsoever. In both cases the sensors themselves were never implanted to eliminate any potential in vivo degradation of the sensors that could have affected the outcome of this study. Sensors were then tested in absence of sponges and found to be working properly with no change from preimplantation sensitivity. Once sensor testing was concluded, the PVA sponge/tissue samples were prepared for quantitative histological analysis. It was determined that the increase in collagen deposition within the sponge correlated with the decrease in sensor sensitivity. It was also observed that natural angiogenesis (peak at day 14) did not overcome the barrier to glucose diffusion created by the fibrous capsule.


Assuntos
Automonitorização da Glicemia/instrumentação , Implantes Experimentais/normas , Animais , Glicemia , Automonitorização da Glicemia/normas , Colágeno/metabolismo , Teste de Materiais , Monitorização Ambulatorial , Neovascularização Fisiológica , Álcool de Polivinil , Ratos , Tampões de Gaze Cirúrgicos/normas
7.
Surg Neurol ; 67(5): 493-5, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17445614

RESUMO

BACKGROUND: Different retractors including high-technology products were proposed for neurosurgical interventions. The sponge, having characteristics of deformability and resistance to compression, might be an alternative retractor for the neurosurgical era. METHODS: Sponge obtainable from the ordinary market was broken into pieces and sterilized by ethylene oxide. During intervention, the appropriate sponge pieces were applied inside the dissected sulci for the purpose of retraction. RESULTS: The sponge pieces were easily applied and supplied optimal retraction during operations. Proximal application to the dissected sylvian fissure enabled the exposure of the inner distal part including the insular surface, whereas application between the frontobasal surface and the orbital roof provided satisfactory exposure of the suprachiasmatic area. The retraction capacity of the sponge was less than that of self-retaining Leyla retractors, but the postoperative appearance of cortical surfaces was fine without any bruising or hyperemia. CONCLUSION: The sponge material, with its inner mechanical characteristics and ease of application like cotton pads, seems to be an alternative retractor in neurosurgical interventions, and these characteristic may inspire development of new high-technology retractors.


Assuntos
Lesões Encefálicas/prevenção & controle , Procedimentos Neurocirúrgicos/instrumentação , Procedimentos Neurocirúrgicos/métodos , Instrumentos Cirúrgicos , Tampões de Gaze Cirúrgicos , Encéfalo/anatomia & histologia , Encéfalo/cirurgia , Fossa Craniana Anterior/anatomia & histologia , Fossa Craniana Anterior/cirurgia , Humanos , Complicações Intraoperatórias/prevenção & controle , Complicações Pós-Operatórias/prevenção & controle , Instrumentos Cirúrgicos/normas , Tampões de Gaze Cirúrgicos/normas , Resultado do Tratamento
8.
Ann R Coll Surg Engl ; 89(2): 166-7, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17346414

RESUMO

INTRODUCTION: Postoperative wound infections are common. Antibiotics are often prescribed empirically, usually in the absence of any microbiological sensitivity data. This study demonstrates the role of fine-needle aspiration microbiology (FNAM) in determining the causative organisms in these wounds compared to wound swabs taken from the same patients. PATIENTS AND METHODS: A total of 20 patients with clinical signs of soft tissue infection were tested using wound swabs and fine-needle aspiration. RESULTS: Six of the wound swabs yielded a single organism but 16 out 20 of the FNAM group yielded a single organism (P = 0.002). CONCLUSIONS: The FNAM approach allows antibiotic sensitivities to be obtained enabling specific antimicrobial therapy to be implemented early. FNAM also has a higher yield of cultures than wound swabs. Cellulitic areas can be sampled even when use of wound swabs is not possible.


Assuntos
Infecções Bacterianas/diagnóstico , Biópsia por Agulha Fina/normas , Tampões de Gaze Cirúrgicos/normas , Infecção da Ferida Cirúrgica/diagnóstico , Adulto , Idoso , Humanos , Pessoa de Meia-Idade , Sensibilidade e Especificidade
9.
Surg Neurol ; 63(6): 569-70, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15936392

RESUMO

BACKGROUND: Measurement of dural sinus or drainage vein pressure is useful for determining the appropriate treatment for some patients. We report a novel measurement procedure that reduces bleeding from the needle puncture site as well as further tearing of the wall. METHODS: The vessel is punctured through the patch by gelatin sponge with fibrin sealant and a siliconized elastic needle is introduced. After obtaining the desired measurements, the needle is withdrawn through the fibrin sealant-bearing patch whose presence facilitates sealing of the puncture site. To further decrease the incidence of complications due to incomplete hemostasis, an additional identically prepared path is placed over the site. RESULTS: We have used this method in several operations and have encountered no complications. Our method also makes it possible to safely approach the drainers of pial arteriovenous malformations. CONCLUSIONS: Our method is easy and convenient and prevents the leakage of blood from the puncture site and further tearing of the venous wall.


Assuntos
Veias Cerebrais/fisiologia , Veias Cerebrais/cirurgia , Cavidades Cranianas/fisiologia , Cavidades Cranianas/cirurgia , Monitorização Intraoperatória/métodos , Procedimentos Neurocirúrgicos/métodos , Procedimentos Cirúrgicos Vasculares/métodos , Pressão Venosa/fisiologia , Veias Cerebrais/fisiopatologia , Cavidades Cranianas/fisiopatologia , Fibrina/uso terapêutico , Humanos , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/fisiopatologia , Complicações Intraoperatórias/prevenção & controle , Manometria/instrumentação , Manometria/métodos , Monitorização Intraoperatória/instrumentação , Agulhas/normas , Procedimentos Neurocirúrgicos/instrumentação , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/fisiopatologia , Hemorragia Pós-Operatória/prevenção & controle , Tampões de Gaze Cirúrgicos/normas , Tampões de Gaze Cirúrgicos/tendências , Procedimentos Cirúrgicos Vasculares/instrumentação
10.
Rhinology ; 41(4): 241-3, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14750352

RESUMO

INTRODUCTION: Nasal packing after routine nasal surgery is commonly practiced in the UK. The most popular pack appears to be Merocel, however this can be associated with significant pain on its removal. AIM: To test the efficacy of a relatively new nasal pack--the Rapid Rhino Goodman pack--introduced to our department, which claims to reduce pain and bleeding after nasal surgery. METHODS: Fourteen patients undergoing routine nasal surgery were recruited into a randomised controlled trial. One nasal cavity was packed with a Merocel pack and the other with a Rapid Rhino Goodman pack. Patients were asked to record pain levels on each side using a visual analogue scale. RESULTS: We found no difference between packs whilst in-situ, with all patients recording low to moderate pain scores. There were significantly higher pain levels associated with Merocel pack removal than with Rapid Rhino pack removal (average pain scores 5.64 vs 1.64, p < 0.001) and less bleeding overall. CONCLUSIONS: Rapid Rhino (Goodman pack) is associated with significantly less pain on removal than Merocel pack, causes less bleeding and is not more painful whilst in-situ. We therefore recommend its use in routine nasal surgery.


Assuntos
Formaldeído/uso terapêutico , Hemostáticos/uso terapêutico , Cavidade Nasal/cirurgia , Dor Pós-Operatória/tratamento farmacológico , Álcool de Polivinil/uso terapêutico , Hemorragia Pós-Operatória/tratamento farmacológico , Adolescente , Adulto , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mucosa Nasal/efeitos dos fármacos , Medição da Dor , Tampões de Gaze Cirúrgicos/efeitos adversos , Tampões de Gaze Cirúrgicos/classificação , Tampões de Gaze Cirúrgicos/normas , Resultado do Tratamento , Reino Unido
12.
J Ocul Pharmacol Ther ; 14(6): 491-6, 1998 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9867332

RESUMO

The use of a sponge impregnated with mitomycin-C is an increasingly common practice in glaucoma surgery. The appropriate antibiotic concentration and exposure time have been considered in the literature, but not the exact amount to be used or the size of the sponge. The purpose of this study was to estimate the quantity of mitomycin-C contained in sponges prepared by different surgeons as compared to that in applicators of the type used in Schirmer's test graduation (5 x 5 mm). Four surgeons each cut and prepared 10 sponges for intraoperative use according to their usual method. The same procedure was performed with 10 Schirmer's test graduations. Each sponge and each graduation was immersed in a solution of mitomycin-C 0.2 mg/ml, and the quantity of antibiotic (microg) in each was calculated as the difference between wet and dry weight. The mean quantity (+/- SEM) of mitomycin-C contained in cut sponges was 9.6 +/- 4.4 microg (range 1.9-17.3), and the differences between surgeons were statistically significant (p<0.0001). The mean quantity of antibiotic in Schirmer's test graduation was 1.7 +/- 0.3 microg (range 1.1-2.5), and the differences between surgeons were not statistically significant (p=0.79). The quantities of mitomycin-C contained in sponges prepared for glaucoma surgery differed for a given surgeon and between surgeons. Thus, variations in the doses applied to the sclera could account for certain complications due to mitomycin-C. The use of a Schirmer's test graduation improves predictability for the quantity of mitomycin-C applied to the sclera.


Assuntos
Antibióticos Antineoplásicos/administração & dosagem , Cirurgia Filtrante , Glaucoma/tratamento farmacológico , Mitomicina/administração & dosagem , Tampões de Gaze Cirúrgicos , Glaucoma/cirurgia , Humanos , Tampões de Gaze Cirúrgicos/normas
13.
J Biomater Sci Polym Ed ; 7(3): 221-9, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-7577825

RESUMO

In order to increase the cartilage synthesis of the perichondrium, we combined auricular perichondrium with a collagen sponge as a template (perichondrium-sandwiched collagen sponge) and implanted the assembly as an autograft into the back of rabbits. Microscopic examination revealed that cartilaginous tissue was produced in the collagen sponge and chondrosynthesis was accelerated in the collagen sponge implants in comparison with that in materials containing perichondrium alone.


Assuntos
Cartilagem/fisiologia , Colágeno , Próteses e Implantes/normas , Tampões de Gaze Cirúrgicos/normas , Animais , Materiais Biocompatíveis , Cartilagem/citologia , Cartilagem/metabolismo , Divisão Celular/fisiologia , Orelha Externa , Porosidade , Coelhos , Moldes Genéticos
14.
J Biomater Sci Polym Ed ; 6(8): 715-28, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-7703188

RESUMO

Collagen-based materials can be designed for use as scaffolds for connective tissue reconstruction. The goal of the present study was to evaluate the behavior of collagen materials as well as cell and tissue reactions after the conjugation of activated polyethylene glycols (PEGs) with collagen. It is known that proteins conjugated with PEGs exhibit a decrease in their biodegradation rate and their immunogenicity. Different concentrations and molecular weights of activated PEGs (PEG-750 and PEG-5000) were conjugated to collagen materials (films or sponges) which were then investigated by collagenase assay, fibroblast cell culture, and subcutaneous implantation. PEG-conjugated collagen sponge degradation by collagenase was delayed in comparison to untreated sponges. In culture, fibroblasts with a normal morphology reached confluency on PEG-conjugated collagen films. In vivo, the porous structure of non-modified sponges collapsed by day 15 with a few observable fibroblasts between the collagen fibers. In PEG-modified collagen sponges, the porous structure remained stable for 30 days. Cell infiltration was particularly enhanced in PEG-750-conjugated collagen sponges. In conclusion, PEGs conjugated onto collagen sponges stabilize the porous structure without deactivating the biological properties of collagen. These porous composite materials could function as a scaffold to organize tissue ingrowth.


Assuntos
Colágeno/química , Polietilenoglicóis/química , Animais , Materiais Biocompatíveis , Biodegradação Ambiental , Bovinos , Células Cultivadas , Colágeno/metabolismo , Colagenases/análise , Portadores de Fármacos , Fibroblastos/citologia , Fibroblastos/efeitos dos fármacos , Microscopia Eletrônica de Varredura , Polietilenoglicóis/metabolismo , Porosidade , Próteses e Implantes/normas , Espectroscopia de Infravermelho com Transformada de Fourier , Tampões de Gaze Cirúrgicos/normas
15.
J R Coll Surg Edinb ; 37(3): 191-3, 1992 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-1404047

RESUMO

A new non-woven theatre swab was compared with traditional gauze in laboratory and clinical studies. Results of both clinical and laboratory-based studies showed the non-woven swab to be as effective as traditional gauze in terms of softness, conformability, ability to pad or pack, resistance to snagging and shredding, and ease of counting when wet. The non-woven swabs were also superior to gauze with regard to their ability to retain fluid. Manufactured from polyester and hemisynthetic viscose, the non-woven swabs can be produced to a uniform standard and are less expensive. It is concluded that the new non-woven material has practical and economic advantages over traditional gauze.


Assuntos
Tampões de Gaze Cirúrgicos/normas , Têxteis , Celulose , Estudos de Avaliação como Assunto , Gossypium , Humanos , Poliésteres
18.
Br J Theatre Nurs ; 1(5): 4, 1991 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-1799716

RESUMO

Swabs are items used every day in every operating room where invasive procedures are performed. How often do scrub nurses hand surgeons swabs, and how often is thought given to their shape, size and composition and their suitability for use inside our patients?


Assuntos
Tampões de Gaze Cirúrgicos/normas , Estudos de Avaliação como Assunto , Humanos , Tampões de Gaze Cirúrgicos/estatística & dados numéricos
19.
Br J Surg ; 77(5): 568-70, 1990 May.
Artigo em Inglês | MEDLINE | ID: mdl-2191753

RESUMO

The influence of a new haemostatic material on surgical bleeding was evaluated in 100 patients who were prospectively randomized to either normal surgical gauze or calcium alginate swabs used throughout cholecystectomy (n = 40), simple mastectomy (n = 18) or inguinal hernia repair (n = 42). Overall, median (range) blood loss was 91 (3-329) ml for gauze and was significantly reduced by calcium alginate swabs to 72 (2-181) ml (P less than 0.05). Unexpectedly, operation times were also shortened from 45 (17-95) min for gauze to 35 (13-70) min with calcium alginate swabs (P less than 0.02). This reduction in blood loss and operating time was greatest for mastectomy, was still statistically significant for cholecystectomy, but was unimportant in inguinal hernia repair. Calcium alginate haemostatic swabs may become routine in major surgery, particularly where blood loss leads to the need for transfusion.


Assuntos
Alginatos/uso terapêutico , Hemostasia Cirúrgica/instrumentação , Hemostáticos/uso terapêutico , Tampões de Gaze Cirúrgicos/normas , Colecistectomia , Drenagem , Feminino , Ácido Glucurônico , Herniorrafia , Ácidos Hexurônicos , Humanos , Período Intraoperatório , Masculino , Mastectomia , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA