Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 819
Filtrar
1.
Biomaterials ; 309: 122605, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38754291

RESUMO

Multidisciplinary therapy centered on radical surgery for resectable pancreatic cancer is expected to prolong prognosis, but relies on CA19-9 biomarker levels to determine treatment strategy. Boron neutron capture therapy (BNCT) is a chemoradiotherapy using tumor hyperaccumulator boron drugs and neutron irradiation. The purpose of this study is to investigate novel boron drug agents for BNCT for pancreatic cancer. Bioinformatics was used to evaluate the uptake of current boron amino acid (BPA) drugs for BNCT into pancreatic cancer. The expression of the amino acid transporter LAT1, a BPA uptake transporter, was low in pancreatic cancer and even lower in high CA19-9 pancreatic cancer. In contrast, the glucose transporter was high in high CA19-9 pancreatic cancers and inversely correlated with LAT1 expression. Considering the low EPR effect in pancreatic cancer, we synthesized a small molecule Glucose-BSH, which is boron BSH bound to glucose, and confirmed its specific uptake in pancreatic cancer. uptake of Glucose-BSH was confirmed in an environment compatible with the tumor microenvironment. The therapeutic efficacy and safety of Glucose-BSH by therapeutic neutron irradiation were confirmed with BNCT. We report Glucose-BSH boron drug discovery study of a Precision Medicine BNCT with application to high CA19-9 pancreatic cancer.


Assuntos
Terapia por Captura de Nêutron de Boro , Glucose , Neoplasias Pancreáticas , Terapia por Captura de Nêutron de Boro/métodos , Neoplasias Pancreáticas/terapia , Neoplasias Pancreáticas/patologia , Humanos , Glucose/metabolismo , Linhagem Celular Tumoral , Animais , Compostos de Boro/química , Compostos de Boro/uso terapêutico , Boro/química , Feminino , Camundongos Nus
2.
Biomed Phys Eng Express ; 10(4)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38744248

RESUMO

Evaluating neutron output is important to ensure proper dose delivery for patients in boron neutron capture therapy (BNCT). It requires efficient quality assurance (QA) and quality control (QC) while maintaining measurement accuracy. This study investigated the optimal measurement conditions for QA/QC of activation measurements using a high-purity germanium (HP-Ge) detector in an accelerator-based boron neutron capture therapy (AB-BNCT) system employing a lithium target. The QA/QC uncertainty of the activation measurement was evaluated based on counts, reproducibility, and standard radiation source uncertainties. Measurements in a polymethyl methacrylate (PMMA) cylindrical phantom using aluminum-manganese (Al-Mn) foils and aluminum-gold (Al-Au) foils and measurements in a water phantom using gold wire with and without cadmium cover were performed to determine the optimal measurement conditions. The QA/QC uncertainties of the activation measurements were 4.5% for Au and 4.6% for Mn. The optimum irradiation proton charge and measurement time were determined to be 36 C and 900 s for measurements in a PMMA cylindrical phantom, 7.0 C and 900 s for gold wire measurements in a water phantom, and 54 C and 900 s at 0-2.2 cm depth and 3,600 s at deeper depths for gold wire measurements with cadmium cover. Our results serve as a reference for determining measurement conditions when performing QA/QC of activation measurements using HP-Ge detectors at an AB-BNCT employing a lithium target.


Assuntos
Terapia por Captura de Nêutron de Boro , Lítio , Aceleradores de Partículas , Imagens de Fantasmas , Controle de Qualidade , Lítio/química , Terapia por Captura de Nêutron de Boro/métodos , Humanos , Aceleradores de Partículas/instrumentação , Reprodutibilidade dos Testes , Polimetil Metacrilato/química , Nêutrons , Ouro/química , Alumínio/química , Água/química , Radiometria/métodos , Radiometria/instrumentação , Dosagem Radioterapêutica
3.
Cells ; 13(10)2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38786022

RESUMO

Given the renewed interest in boron neutron capture therapy (BNCT) and the intensified search for improved boron carriers, as well as the difficulties of coherently comparing the carriers described so far, it seems necessary to define a basic set of assays and standardized methods to be used in the early stages of boron carrier development in vitro. The selection of assays and corresponding methods is based on the practical experience of the authors and is certainly not exhaustive, but open to discussion. The proposed tests/characteristics: Solubility, lipophilicity, stability, cytotoxicity, and cellular uptake apply to both low molecular weight (up to 500 Da) and high molecular weight (5000 Da and more) boron carriers. However, the specific methods have been selected primarily for low molecular weight boron carriers; in the case of high molecular weight compounds, some of the methods may need to be adapted.


Assuntos
Compostos de Boro , Terapia por Captura de Nêutron de Boro , Peso Molecular , Terapia por Captura de Nêutron de Boro/métodos , Compostos de Boro/química , Humanos
4.
Sci Rep ; 14(1): 11253, 2024 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-38755333

RESUMO

Accelerator-based boron neutron capture therapy (BNCT) systems employing a solid-state lithium target indicated the reduction of neutron flux over the lifetime of a target, and its reduction could represent the neutron flux model. This study proposes a novel compensatory approach for delivering the required neutron fluence and validates its clinical applicability. The proposed approach relies on the neutron flux model and the cumulative sum of real-time measurements of proton charges. The accuracy of delivering the required neutron fluence for BNCT using the proposed approach was examined in five Li targets. With the proposed approach, the required neutron fluence could be delivered within 3.0%, and within 1.0% in most cases. However, those without using the proposed approach exceeded 3.0% in some cases. The proposed approach can consider the neutron flux reduction adequately and decrease the effect of uncertainty in neutron measurements. Therefore, the proposed approach can improve the accuracy of delivering the required fluence for BNCT even if a neutron flux reduction is expected during treatment and over the lifetime of the Li target. Additionally, by adequately revising the approach, it may apply to other type of BNCT systems employing a Li target, furthering research in this direction.


Assuntos
Terapia por Captura de Nêutron de Boro , Lítio , Nêutrons , Terapia por Captura de Nêutron de Boro/métodos , Lítio/química , Humanos , Aceleradores de Partículas , Dosagem Radioterapêutica
6.
Appl Radiat Isot ; 209: 111330, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38657372

RESUMO

Boron neutron capture therapy (BNCT) has received extensive attention as an advanced binary radiotherapy method. However, BNCT still faces poor selectivity of boron agent and is insufficient boron content in tumor tissues. To improve the tumor-targeted ability and boron content, this research aims to design, synthesize and preliminary evaluate a new borane agent Carborane-FAPI, which coupling the o-carborane to the compound skeleton of a mature fibroblast activating protein (FAP) inhibitor (FAPI). FAP is a tumor-associated antigen. FAP expressed lowly in normal organs and highly expressed in tumors, so it is a potential target for diagnosis and treatment. Boronophenylalanine (BPA) is the most widely investigated BNCT drug in present. Compared with BPA, the boron content of a single molecule is increased and drug targeting is enhanced. The results show that Carboaren-FAPI has low toxicity to normal cells, and selective enrichment in tumor tissues. It is a promising boron drug that has the potential to be used in BNCT.


Assuntos
Boranos , Terapia por Captura de Nêutron de Boro , Boro , Terapia por Captura de Nêutron de Boro/métodos , Humanos , Animais , Camundongos , Proteínas de Membrana/metabolismo , Endopeptidases , Serina Endopeptidases/metabolismo , Gelatinases/metabolismo , Compostos de Boro/uso terapêutico , Compostos de Boro/farmacocinética , Linhagem Celular Tumoral
7.
J Neurooncol ; 168(1): 91-97, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38598087

RESUMO

PURPOSE: Boron neutron capture therapy (BNCT) is a tumor cell-selective particle-radiation therapy. In BNCT, administered p-boronophenylalanine (BPA) is selectively taken up by tumor cells, and the tumor is irradiated with thermal neutrons. High-LET α-particles and recoil 7Li, which have a path length of 5-9 µm, are generated by the capture reaction between 10B and thermal neutrons and selectively kill tumor cells that have uptaken 10B. Although BNCT has prolonged the survival time of malignant glioma patients, recurrences are still to be resolved. miRNAs, that are encapsulated in small extracellular vesicles (sEVs) in body fluids and exist stably may serve critical role in recurrence. In this study, we comprehensively investigated microRNAs (miRNAs) in sEVs released from post-BNCT glioblastoma cells. METHOD: Glioblastoma U87 MG cells were treated with 25 ppm of BPA in the culture media and irradiated with thermal neutrons. After irradiation, they were plated into dishes and cultured for 3 days in the 5% CO2 incubator. Then, sEVs released into the medium were collected by column chromatography, and miRNAs in sEVs were comprehensively investigated using microarrays. RESULT: An increase in 20 individual miRNAs (ratio > 2) and a decrease in 2 individual miRNAs (ratio < 0.5) were detected in BNCT cells compared with non-irradiated cells. Among detected miRNAs, 20 miRNAs were associated with worse prognosis of glioma in Kaplan Meier Survival Analysis of overall survival in TCGA. CONCLUSION: These miRNA after BNCT may proceed tumors, modulate radiation resistance, or inhibit invasion and affect the prognosis of glioma.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias Encefálicas , Vesículas Extracelulares , Glioblastoma , MicroRNAs , Terapia por Captura de Nêutron de Boro/métodos , Humanos , Vesículas Extracelulares/metabolismo , Vesículas Extracelulares/efeitos da radiação , MicroRNAs/metabolismo , MicroRNAs/genética , Glioblastoma/radioterapia , Glioblastoma/metabolismo , Glioblastoma/patologia , Glioblastoma/genética , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/genética , Neoplasias Encefálicas/metabolismo , Linhagem Celular Tumoral , Regulação Neoplásica da Expressão Gênica/efeitos da radiação
8.
Appl Radiat Isot ; 207: 111249, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38428203

RESUMO

The 71Ga(n,γ)72Ga reaction-based epithermal neutron flux detectors are novel instruments developed to measure the epithermal neutron flux of boron neutron capture therapy (BNCT) treatment beams. In this study, a spherical epithermal neutron flux detector using 71Ga(n,γ)72Ga reaction was prototyped. The performance of the detector was experimentally evaluated at an accelerator-based BNCT (AB-BNCT) device developed by Lanzhou University, China. Based on the experimental results and related analysis, we demonstrated that the detector is a reliable tool for the quality assurance of BNCT treatment beams.


Assuntos
Terapia por Captura de Nêutron de Boro , Humanos , Terapia por Captura de Nêutron de Boro/métodos , Nêutrons , Dosagem Radioterapêutica , Raios gama , Método de Monte Carlo
9.
Appl Radiat Isot ; 208: 111303, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38531243

RESUMO

Boron neutron capture therapy (BNCT) is an effective binary radiation therapy that depends on nuclear capture reactions. In recent years, BNCT can be performed without a reactor owing to the development of accelerator-based neutron sources. A new BNCT irradiation facility is proposed, which is based on a 15 mA 2.5 MeV proton accelerator with a 100 µm thickness natural lithium target as a neutron converter. A great quantity of studies has shown that neutron beams with different spectra have unique therapeutic effects on tumors. An appropriate neutron beam for BNCT is obtained by Beam Shaping Assembly (BSA) and the moderator plays a main role in determining the BSA outlet beam spectrum. To figure out the dose distribution in phantom with various kinds of neutron spectrum modes during BNCT, a series of cases are calculated by MCNPX code. The results give a database for treatment of brain tumors with BNCT by using different moderators.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias Encefálicas , Humanos , Terapia por Captura de Nêutron de Boro/métodos , Neoplasias Encefálicas/radioterapia , Lítio , Dosagem Radioterapêutica , Prótons , Nêutrons , Método de Monte Carlo
10.
Radiat Prot Dosimetry ; 200(7): 623-628, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38527175

RESUMO

Although boron neutron capture therapy (BNCT) causes minor damage to normal cells owing to the nuclear reactions induced by neutrons with major elements of tissues such as hydrogen and nitrogen, it is useful to estimate the accurate exposure dose for radiation protection. This study aims to estimate the contribution of internal exposure in radiation exposure dose for BNCT. The study was performed by referring to clinical studies at a reactor-based BNCT facility on the basis of computational dosimetry. Five irradiation regions of head and neck were selected for the estimation. The results suggest that external exposure occurred primarily in and around the irradiation field. Furthermore, during the exposure dose estimation in BNCT, internal exposure was found to be not negligible, implying that the irradiation regions in treatment planning must be considered for avoiding damage to certain critical organs that are susceptible to internal exposure.


Assuntos
Terapia por Captura de Nêutron de Boro , Terapia por Captura de Nêutron de Boro/métodos , Humanos , Dosagem Radioterapêutica , Nêutrons , Doses de Radiação , Radiometria/métodos , Proteção Radiológica/métodos , Exposição à Radiação/análise , Planejamento da Radioterapia Assistida por Computador/métodos , Método de Monte Carlo , Neoplasias de Cabeça e Pescoço/radioterapia , Imagens de Fantasmas , Simulação por Computador
11.
Chem Rev ; 124(5): 2441-2511, 2024 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-38382032

RESUMO

Boron-containing compounds (BCC) have emerged as important pharmacophores. To date, five BCC drugs (including boronic acids and boroles) have been approved by the FDA for the treatment of cancer, infections, and atopic dermatitis, while some natural BCC are included in dietary supplements. Boron's Lewis acidity facilitates a mechanism of action via formation of reversible covalent bonds within the active site of target proteins. Boron has also been employed in the development of fluorophores, such as BODIPY for imaging, and in carboranes that are potential neutron capture therapy agents as well as novel agents in diagnostics and therapy. The utility of natural and synthetic BCC has become multifaceted, and the breadth of their applications continues to expand. This review covers the many uses and targets of boron in medicinal chemistry.


Assuntos
Boranos , Terapia por Captura de Nêutron de Boro , Neoplasias , Humanos , Boro/química , Química Farmacêutica , Compostos de Boro/química , Neoplasias/tratamento farmacológico , Ácidos Borônicos , Terapia por Captura de Nêutron de Boro/métodos
12.
Appl Radiat Isot ; 205: 111184, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38215645

RESUMO

Boron neutron capture therapy (BNCT) combines neutron irradiation with boron compounds that are selectively uptaken by tumor cells. Boronophenylalanine (BPA) is a boron compound used to treat malignant brain tumors. The determination of boron concentration in cells is of great relevance to the field of BNCT. This study was designed to develop a novel method for simultaneously measuring the uptake of BPA by U87 and U251 cells (two brain tumor cell lines) and number of cells using inductively coupled plasma atomic emission spectroscopy (ICP-AES). The results revealed a linear correlation between phosphorus intensity and the numbers of U87 and U251 cells, with correlation coefficients (R2) of 0.9995 and 0.9994, respectively. High accuracy and reliability of phosphorus concentration standard curve were also found. Using this new method, we found that BPA had no significant effect on phosphorus concentration in either U87 or U251 cells. However, BPA increased the boron concentration in U87 and U251 cells in a concentration-dependent manner, with the boron concentration in U87 cells being higher than that in U251 cells. In both U87 and U251 cells, boron was mainly distributed in the cytoplasm and nucleus, accounting for 85% and 13% of the total boron uptake by U87 cells and 86% and 11% of the total boron uptake by U251 cells, respectively. In the U87 and U251 cell-derived xenograft (CDX) animal model, tumor exhibited higher boron concentration values than blood, heart, liver, lung, and brain, with a tumor/blood ratio of 2.87 for U87 cells and 3.11 for U251 cells, respectively. These results suggest that the phosphorus concentration in U87 and U251 cells can represent the number of cells and BPA is easily uptaken by tumor cells as well as in tumor tissue.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias Encefálicas , Animais , Humanos , Espectrofotometria Atômica , Boro , Reprodutibilidade dos Testes , Neoplasias Encefálicas/radioterapia , Encéfalo , Compostos de Boro , Fósforo , Terapia por Captura de Nêutron de Boro/métodos
13.
ACS Appl Mater Interfaces ; 16(3): 3232-3242, 2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38221726

RESUMO

Accurate prediction of the relative biological effectiveness (RBE) of boron neutron capture therapy (BNCT) is challenging. The therapy is different from other radiotherapy; the dynamic distribution of boron-containing compounds in tumor cells affects the therapeutic outcome considerably and hampers accurate measurement of the neutron-absorbed dose. Herein, we used boron-containing metal-organic framework nanoparticles (BMOFs) with high boron content to target U87-MG cells and maintain the concentration of the 10B isotope in cells. The content of boron in the cells could maintain 90% (60 ppm) within 20 min compared with that at the beginning; therefore, the accurate RBE of BNCT can be acquired. The effects of BNCT upon cells after neutron irradiation were observed, and the neutron-absorbed dose was obtained by Monte Carlo simulations. The RBE of BMOFs was 6.78, which was 4.1-fold higher than that of a small-molecule boron-containing agent (boric acid). The energy spectrum of various particles was analyzed by Monte Carlo simulations, and the RBE was verified theoretically. Our results suggested that the use of nanoparticle-based boron carriers in BNCT may have many advantages and that maintaining a stable boron distribution within cells may significantly improve the efficiency of BNCT.


Assuntos
Terapia por Captura de Nêutron de Boro , Boro , Terapia por Captura de Nêutron de Boro/métodos , Eficiência Biológica Relativa , Nêutrons
14.
Sci Rep ; 14(1): 418, 2024 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172585

RESUMO

Boron Neutron Capture Therapy (BNCT) is a radiotherapy technique based on the enrichment of tumour cells with suitable 10-boron concentration and on subsequent neutron irradiation. Low-energy neutron irradiation produces a localized deposition of radiation dose caused by boron neutron capture reactions. Boron is vehiculated into tumour cells via proper borated formulations, able to accumulate in the malignancy more than in normal tissues. The neutron capture releases two high-LET charged particles (i.e., an alpha particle and a lithium ion), losing their energy in a distance comparable to the average dimension of one cell. Thus BNCT is selective at the cell level and characterized by high biological effectiveness. As the radiation field is due to the interaction of neutrons with the components of biological tissues and with boron, the dosimetry requires a formalism to express the absorbed dose into photon-equivalent units. This work analyzes a clinical case of an adenoid cystic carcinoma treated with carbon-ion radiotherapy (CIRT), located close to optic nerve and deep-seated as a practical example of how to apply the formalism of BNCT photon isoeffective dose and how to evaluate the BNCT dose distribution against CIRT. The example allows presenting different dosimetrical and radiobiological quantities and drawing conclusions on the potential of BNCT stemming on the clinical result of the CIRT. The patient received CIRT with a dose constraint on the optic nerve, affecting the peripheral part of the Planning Target Volume (PTV). After the treatment, the tumour recurred in this low-dose region. BNCT was simulated for the primary tumour, with the goal to calculate the dose distribution in isoeffective units and a Tumour Control Probability (TCP) to be compared with the one of the original treatment. BNCT was then evaluated for the recurrence in the underdosed region which was not optimally covered by charged particles due to the proximity of the optic nerve. Finally, a combined treatment consisting in BNCT and carbon ion therapy was considered to show the consistency and the potential of the model. For the primary tumour, the photon isoeffective dose distribution due to BNCT was evaluated and the resulted TCP was higher than that obtained for the CIRT. The formalism produced values that are consistent with those of carbon-ion. For the recurrence, BNCT dosimetry produces a similar TCP than that of primary tumour. A combined treatment was finally simulated, showing a TCP comparable to the BNCT-alone with overall dosimetric advantage in the most peripheral parts of the treatment volume. Isoeffective dose formalism is a robust tool to analyze BNCT dosimetry and to compare it with the photon-equivalent dose calculated for carbon-ion treatment. This study introduces for the first time the possibility to combine the dosimetry obtained by two different treatment modalities, showing the potential of exploiting the cellular targeting of BNCT combined with the precision of charged particles in delivering an homogeneous dose distribution in deep-seated tumours.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias de Cabeça e Pescoço , Radioterapia com Íons Pesados , Humanos , Terapia por Captura de Nêutron de Boro/métodos , Boro , Carbono , Nêutrons
15.
Int J Radiat Biol ; 100(4): 609-618, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38190436

RESUMO

PURPOSE: The current study aimed to investigate boron carbide and boric acid nanoparticles (NPs) as absorbents for thermal neutrons and high-density polyethylene (HDPE) as a substrate and neutron moderator for fast neutrons. The goal was to assess the performance of boron carbide and boric acid NPs based on HDPE as a nanoshield of photoneutrons from medical linear accelerators. MATERIALS AND METHODS: This study was conducted in two parts of simulation and practice. The Monte Carlo (MC) simulation involved modeling and verification of the single-layer, double-layer, and combined nanoshields by selecting nanomaterials and substrates and, finally, calculating the macroscopic cross-sections. The practical part involved manufacturing nanoshields based on the simulation results and evaluating the manufactured nanocomposites via experimental measurements. RESULTS: MC simulation results with an uncertainty of less than 1% showed that for the monolayer samples, the best result belonged to boron carbide at a concentration of 10% and a macroscopic cross-section of 0.933 cm-1. At a concentration of 20%, the highest value among the double-layer samples was 0.936 cm-1 and for the combined samples, this value was 0.928 cm-1. Boron carbide single-layer nanocomposites at a 10% concentration, as well as the bilayer nanoshield of 10% boron carbide and 20% boric acid performed well; however, the best performance belonged to the nanoshield with a macroscopic cross-section of 0.960 and the combination containing 5% boron carbide and 10% boric acid. CONCLUSIONS: The research suggests that utilizing boron carbide and boric acid nanoshields in combination with HDPE holds promise as a viable approach to protecting from the photoneutrons. Further exploration of these nanocomposite shields and their practical applications is warranted, with the potential to yield significant advancements in radiation therapy safety and efficacy.


Assuntos
Ácidos Bóricos , Terapia por Captura de Nêutron de Boro , Nanopartículas , Polietileno , Boro , Compostos de Boro , Nêutrons , Aceleradores de Partículas , Método de Monte Carlo , Terapia por Captura de Nêutron de Boro/métodos
16.
Med Phys ; 51(5): 3711-3724, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38205862

RESUMO

BACKGROUND: In Japan, the clinical treatment of boron neutron capture therapy (BNCT) has been applied to unresectable, locally advanced, and recurrent head and neck carcinomas using an accelerator-based neutron source since June of 2020. Considering the increase in the number of patients receiving BNCT, efficiency of the treatment planning procedure is becoming increasingly important. Therefore, novel and rapid dose calculation algorithms must be developed. We developed a novel algorithm for calculating neutron flux, which comprises of a combination of a Monte Carlo (MC) method and a method based on the removal-diffusion (RD) theory (RD calculation method) for the purpose of dose calculation of BNCT. PURPOSE: We present the details of our novel algorithm and the verification results of the calculation accuracy based on the MC calculation result. METHODS: In this study, the "MC-RD" calculation method was developed, wherein the RD calculation method was used to calculate the thermalization process of neutrons and the MC method was used to calculate the moderation process. The RD parameters were determined by MC calculations in advance. The MC-RD calculation accuracy was verified by comparing the results of the MC-RD and MC calculations with respect to the neutron flux distributions in each of the cubic and head phantoms filled with water. RESULTS: Comparing the MC-RD calculation results with those of MC calculations, it was found that the MC-RD calculation accurately reproduced the thermal neutron flux distribution inside the phantom, with the exception of the region near the surface of the phantom. CONCLUSIONS: The MC-RD calculation method is useful for the evaluation of the neutron flux distribution for the purpose of BNCT dose calculation, except for the region near the surface.


Assuntos
Algoritmos , Terapia por Captura de Nêutron de Boro , Método de Monte Carlo , Nêutrons , Planejamento da Radioterapia Assistida por Computador , Terapia por Captura de Nêutron de Boro/métodos , Nêutrons/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos , Difusão , Dosagem Radioterapêutica , Imagens de Fantasmas , Humanos
17.
Med Phys ; 51(1): 439-446, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37956252

RESUMO

BACKGROUND: Boron-containing compounds, such as 4-borono-phenylalanine (BPA) are used as drugs for cancer treatment in the framework of Boron Neutron Capture Therapy (BNCT). Neutron irradiation of boron-rich compounds delivered to cancer cells triggers nuclear reactions that destroy cancer cells. PURPOSE: We provide a modeling of the thermal neutron cross section of BPA, a drug used in Boron Neutron Capture Therapy (BNCT), to quantify the competing contributions of boron absorption against hydrogen scattering, for optimizing BNCT by minimizing the latter. METHODS: We perform the experimental determination of the total neutron scattering cross section of BPA at thermal and epithermal neutron energies using neutron transmission measurements. We isolate the contribution related to the incoherent scattering by hydrogen atoms as a function of the neutron energy by means of the Average Functional Group Approximation, and we calculate the probability for a neutron of being absorbed as a function of the neutron energy both for BPA and for its variants where either one or all four aromatic hydrogen atoms are substituted by 19 F, and both for the samples with natural occurrence or enriched concentration of 10 B. RESULTS: While referring to the already available literature for in vivo use of fluorinated BPA, we show that fluorine-rich variants of BPA increase the probability of neutrons being captured by the molecule. As the higher absorption efficiency of fluorinated BPA does not depend on whether the molecule is used in vivo or not, our results are promising for the higher efficiency of the boron neutron capture treatment. CONCLUSIONS: Our results suggest a new advantage using fluorinated compounds for BNCT, in their optimized interaction with neutrons, in addition to their already known capability to be used for monitoring and pharmacokinetics studies using 19 F-Nuclear Magnetic Resonance or in 18 F-Positron Emission Tomography.


Assuntos
Terapia por Captura de Nêutron de Boro , Boro , Terapia por Captura de Nêutron de Boro/métodos , Fenilalanina/farmacocinética , Fenilalanina/uso terapêutico , Tomografia Computadorizada por Raios X , Nêutrons , Compostos de Boro/uso terapêutico , Compostos de Boro/farmacocinética
18.
Med Phys ; 51(1): 509-521, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37672219

RESUMO

BACKGROUND: Evaluation of the boron dose is essential for boron neutron capture therapy (BNCT). Nevertheless, a direct evaluation method for the boron-dose distribution has not yet been established in the clinical BNCT field. To date, even in quality assurance (QA) measurements, the boron dose has been indirectly evaluated from the thermal neutron flux measured using the activation method with gold foil or wire and an assumed boron concentration in the QA procedure. Recently, we successfully conducted optical imaging of the boron-dose distribution using a cooled charge-coupled device (CCD) camera and a boron-added liquid scintillator at the E-3 port facility of the Kyoto University Research Reactor (KUR), which supplies an almost pure thermal neutron beam with very low gamma-ray contamination. However, in a clinical accelerator-based BNCT facility, there is a concern that the boron-dose distribution may not be accurately extracted because the unwanted luminescence intensity, which is irrelevant to the boron dose is expected to increase owing to the contamination of fast neutrons and gamma rays. PURPOSE: The purpose of this research was to study the validity of a newly proposed method using a boron-added liquid scintillator and a cooled CCD camera to directly observe the boron-dose distribution in a clinical accelerator-based BNCT field. METHOD: A liquid scintillator phantom with 10 B was prepared by filling a small quartz glass container with a commercial liquid scintillator and boron-containing material (trimethyl borate); its natural boron concentration was 1 wt%. Luminescence images of the boron-neutron capture reaction were obtained in a water tank at several different depths using a CCD camera. The contribution of background luminescence, mainly due to gamma rays, was removed by subtracting the luminescence images obtained using another sole liquid scintillator phantom (natural boron concentration of 0 wt%) at each corresponding depth, and a depth profile of the boron dose with several discrete points was obtained. The obtained depth profile was compared with that of calculated boron dose, and those of thermal neutron flux which were experimentally measured or calculated using a Monte Carlo code. RESULTS: The depth profile evaluated from the subtracted images indicated reasonable agreement with the calculated boron-dose profile and thermal neutron flux profiles, except for the shallow region. This discrepancy is thought to be due to the contribution of light reflected from the tank wall. The simulation results also demonstrated that the thermal neutron flux would be severely perturbed by the 10 B-containing phantom if a relatively larger container was used to evaluate a wide range of boron-dose distributions in a single shot. This indicates a trade-off between the luminescence intensity of the 10 B-added phantom and its perturbation effect on the thermal neutron flux. CONCLUSIONS: Although a partial discrepancy was observed, the validity of the newly proposed boron-dose evaluation method using liquid-scintillator phantoms with and without 10 B was experimentally confirmed in the neutron field of an accelerator-based clinical BNCT facility. However, this study has some limitations, including the trade-off problem stated above. Therefore, further studies are required to address these limitations.


Assuntos
Terapia por Captura de Nêutron de Boro , Boro , Humanos , Terapia por Captura de Nêutron de Boro/métodos , Estudos de Viabilidade , Nêutrons , Imagens de Fantasmas , Método de Monte Carlo , Imagem Óptica , Dosagem Radioterapêutica
19.
Med Phys ; 51(2): 1351-1363, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38153111

RESUMO

BACKGROUND: The out-of-field radiation dose for boron neutron capture therapy (BNCT), which results from both neutrons and γ-rays, has not been extensively evaluated. To safely perform BNCT, the neutron and γ-ray distributions inside the treatment room and the whole-body dose should be evaluated during commissioning. Although, certain previous studies have evaluated the whole-body dose in the clinical research phase, no institution providing BNCT covered by health insurance has yet validated the neutron distribution inside the room and the whole-body dose. PURPOSE: To validate the Monte Carlo model of the BNCT irradiation room extended for the whole-body region and evaluate organ-at-risk (OAR) doses using the validated model with a human-body phantom. METHODS: First, thermal neutron distribution inside the entire treatment room was measured by placing Au samples on the walls of the treatment room. Second, neutron and gamma-ray dose-rate distributions inside a human-body water phantom were measured. Both lying and sitting positions were considered. Bare Au, Au covered by Cd (Au+Cd), In, Al, and thermoluminescent dosimeters were arranged at 11 points corresponding to locations of the OARs inside the phantom. After the irradiation, γ-ray peaks emitted from the samples were measured by a high-purity germanium detector. The measured counts were converted to the reaction rate per unit charge of the sample. These measurements were compared with results of simulations performed with the Particle and Heavy Ion Transport code System (PHITS). A male adult mesh-type reference computational phantom was used to evaluate OAR doses in the whole-body region. The relative biological effectiveness (RBE)-weighted doses and dose-volume histograms (DVHs) for each OAR were evaluated. The median dose (D50% ) and near-maximum dose (D2% ) were evaluated for 14 OARs in a 1-h-irradiation process. The evaluated RBE-weighted doses were converted to equivalent doses in 2 Gy fractions. RESULTS: Experimental results within 60 cm from the irradiation center agreed with simulation results within the error bars except at ±20, 30 cm, and those over 70 cm corresponded within one digit. The experimental results of reaction rates or γ-ray dose rate for lying and sitting positions agreed well with the simulation results within the error bars at 8, 4, 11, 7 and 7, 4, 7, 6, 5, 6 out of 11 points, respectively, for Au, Au+Cd, In, Al, and TLD. Among the detectors, the discrepancies in reaction rates between experiment and simulation were most common for Au+Cd, but were observed randomly for measurement points (brain, lung, etc.). The experimental results of γ-ray dose rates were systematically lower than simulation results at abdomen and waist regions for both positions. Extending the PHITS model to the whole-body region resulted in higher doses for all OARs, especially 0.13 Gy-eq increase for D50% of the left salivary gland. CONCLUSION: The PHITS model for clinical BNCT for the whole-body region was validated, and the OAR doses were then evaluated. Clinicians and medical physicists should know that the out-of-field radiation increases the OAR dose in the whole-body region.


Assuntos
Terapia por Captura de Nêutron de Boro , Humanos , Terapia por Captura de Nêutron de Boro/métodos , Cádmio , Simulação por Computador , Método de Monte Carlo , Nêutrons , Radiometria/métodos , Dosagem Radioterapêutica
20.
Bioorg Chem ; 142: 106940, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37939508

RESUMO

A [10B]boron agent and a nuclear imaging probe for pharmacokinetic estimation form the fundamental pair in successful boron neutron capture therapy (BNCT). However, 4-[10B]borono-l-phenylalanine (BPA), used in clinical BNCT, has undesirable water solubility and tumor selectivity. Therefore, we synthesized fluorinated and α-methylated 3-borono-l-phenylalanine (3BPA) derivatives to realize improved water solubility, tumor targetability, and biodistribution. All 3BPA derivatives exhibited over 10 times higher water solubility than BPA. Treatment with α-methylated 3BPA derivatives resulted in decreased cell uptake via l-type amino acid transporter (LAT) 2 while maintaining LAT1 recognition, thereby significantly improving LAT1/LAT2 selectivity. Biodistribution studies showed that fluorinated α-methyl 3BPA derivatives exhibited reduced boron accumulation in nontarget tissues, including muscle, skin, and plasma. Consequently, these derivatives demonstrated significantly improved tumor-to-normal tissue ratios compared to 3BPA and BPA. Overall, fluorinated α-methyl 3BPA derivatives with the corresponding radiofluorinated compounds hold potential as promising agents for future BNCT/PET theranostics.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias , Humanos , Boro/metabolismo , Terapia por Captura de Nêutron de Boro/métodos , Distribuição Tecidual , Neoplasias/radioterapia , Neoplasias/tratamento farmacológico , Fenilalanina/química , Água , Compostos de Boro/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA