Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 526
Filtrar
1.
Clin Lab ; 70(5)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38747914

RESUMO

BACKGROUND: Nucleic acid amplification testing is the gold standard for SARS-CoV-2 diagnostics, although it may produce a certain number of false positive results. There has not been much published about the characteristics of false positive results. In this study, based on retesting, specimens that initially tested positive for SARS-CoV-2 were classified as true or false positive groups to characterize the distribution of cycle threshold (CT) values for N1 and N2 targets and number of targets detected for each group. METHODS: Specimens that were positive for N-gene on retesting and accompanied with S-gene were identified as true positives (true positive based on retesting, rTP), while specimens that retested negative were classified as false positives (false positive based on retesting, rFP). RESULTS: Of the specimens retested, 85/127 (66.9%) were rFP, 16/47 (34.0%) specimens with both N1 and N2 targets initially detected were rFP, and the CT values for each target was higher in rFP than in rTP. ROC curve analysis showed that optimal cutoff values of CT to differentiate between rTP and rFP were 34.8 for N1 and 33.0 for N2. With the optimal cutoff values of CT for each target, out of the 24 specimens that were positive for both N1 and N2 targets and classified as rTP, 23 (95.8%) were correctly identified as true positives. rFP specimens had a single N1 target in 52/61 (85.2%) and a single N2 target in 17/19 (89.5%). Notably, no true positive results were obtained from any specimens with only N2 target detected. CONCLUSIONS: These results suggest that retesting should be performed for positive results with a CT value greater than optimal cutoff value for each target or with a single N1 target amplified, considering the possibility of a false positive. This may provide guidance on indications to perform retesting to minimize the number of false positives.


Assuntos
Teste de Ácido Nucleico para COVID-19 , COVID-19 , SARS-CoV-2 , Humanos , Reações Falso-Positivas , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/virologia , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/normas , Curva ROC , Glicoproteína da Espícula de Coronavírus/genética , Sensibilidade e Especificidade , Proteínas do Nucleocapsídeo de Coronavírus/genética , RNA Viral/genética , RNA Viral/análise
2.
Medicine (Baltimore) ; 103(19): e38186, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38728447

RESUMO

The detection of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) nucleic acid detection provides a direct basis for diagnosing Coronavirus Disease 2019. However, nucleic acid test false-negative results are common in practice and may lead to missed diagnosis. Certain biomarkers, clinical symptoms, and imaging examinations are related to SARS-CoV-2 nucleic acid detection and potential predictors. We examined nucleic acid test results, biomarkers, clinical symptoms, and imaging examination data for 116 confirmed cases and asymptomatic infections in Zhuhai, China. Patients were divided into nucleic acid-positive and -false-negative groups. Predictive values of biomarkers, symptoms, and imaging for the nucleic acid-positive rate were calculated by Least Absolute Shrinkage and Selection Operators regression analysis and binary logistic regression analysis, and areas under the curve of these indicators were calculated. Hemoglobin (OR = 1.018, 95% CI: 1.006-1.030; P = .004) was higher in the respiratory tract-positive group than the nucleic acid-negative group, but platelets (OR = 0.996, 95% CI: 0.993-0.999; P = .021) and eosinophils (OR = 0.013, 95% CI: 0.001-0.253; P = .004) were lower; areas under the curve were 0.563, 0.614, and 0.642, respectively. Some biomarkers can predict SARS-CoV-2 viral nucleic acid detection rates in Coronavirus Disease 2019 and are potential auxiliary diagnostic tests.


Assuntos
Biomarcadores , Teste de Ácido Nucleico para COVID-19 , COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Masculino , Feminino , Pessoa de Meia-Idade , Biomarcadores/sangue , Adulto , Teste de Ácido Nucleico para COVID-19/métodos , China , Modelos Logísticos , Idoso , Valor Preditivo dos Testes
3.
BMC Infect Dis ; 24(1): 504, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38769524

RESUMO

BACKGROUND: While numerous studies have evaluated the real-world performance of rapid antigen tests (RATs), data on the effect of Omicron sublineages such as XBB and reinfections on RAT performance is limited. We assessed the performance of RATs and factors associated with RAT-negative results among individuals who tested SARS-CoV-2-positive by reverse transcription-polymerase chain reaction (RT-PCR). METHODS: We conducted a retrospective study among Singapore residents who underwent testing for SARS-CoV-2 with RAT (Acon Flowflex or SD Biosensor) and RT-PCR in the same clinical encounter between 9 May 2022 and 21 November 2022. RT-PCR served as a reference standard for RAT performance. Logistic regression was used to estimate the odds ratios (OR) of factors associated with negative RAT results among RT-PCR-positive cases. RESULTS: Of 8,620 clinical encounters analysed, 3,519 (40.8%) were SARS-CoV-2-positive on RT-PCR. Overall sensitivity and specificity of RAT was 84.6% (95% CI 83.3-85.7%) and 99.4% (95% CI 99.1-99.6%) respectively. Acon Flowflex consistently achieved higher sensitivity and specificity than SD Biosensor test kit. Among RT-PCR-positive cases, individuals who had a previous documented SARS-CoV-2 infection, coinfection with another respiratory pathogen or tested ≥ 6 days from symptom onset had higher odds of testing RAT-negative, but the associations were attenuated after adjustment for cycle threshold values (proxy for viral load). There was no significant difference in RAT performance between Omicron sublineages BA.2, BA.5 and XBB.1. CONCLUSION: Diagnostic performance of RAT was not affected by changes in predominant circulating Omicron sublineages. However, reinfection cases may be under ascertained by RAT. In individuals with a previous SARS-CoV-2 infection episode or symptom onset ≥ 6 days prior to testing, a confirmatory RT-PCR may be considered if there is high clinical suspicion.


Assuntos
Teste Sorológico para COVID-19 , COVID-19 , SARS-CoV-2 , Sensibilidade e Especificidade , COVID-19/diagnóstico , SARS-CoV-2/genética , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , Humanos , Masculino , Estudos Retrospectivos , Singapura , Adulto , Pessoa de Meia-Idade , Feminino , Teste Sorológico para COVID-19/métodos , Idoso , Adulto Jovem , Teste de Ácido Nucleico para COVID-19/métodos
4.
Sci Rep ; 14(1): 10612, 2024 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-38719936

RESUMO

Molecular diagnostics involving nucleic acids (DNA and RNA) are regarded as extremely functional tools. During the 2020 global health crisis, efforts intensified to optimize the production and delivery of molecular diagnostic kits for detecting SARS-CoV-2. During this period, RT-LAMP emerged as a significant focus. However, the thermolability of the reagents used in this technique necessitates special low-temperature infrastructure for transport, storage, and conservation. These requirements limit distribution capacity and necessitate cost-increasing adaptations. Consequently, this report details the development of a lyophilization protocol for reagents in a colorimetric RT-LAMP diagnostic kit to detect SARS-CoV-2, facilitating room-temperature transport and storage. We conducted tests to identify the ideal excipients that maintain the molecular integrity of the reagents and ensure their stability during room-temperature storage and transport. The optimal condition identified involved adding 5% PEG 8000 and 75 mM trehalose to the RT-LAMP reaction, which enabled stability at room temperature for up to 28 days and yielded an analytical and diagnostic sensitivity and specificity of 83.33% and 90%, respectively, for detecting SARS-CoV-2. This study presents the results of a lyophilized colorimetric RT-LAMP COVID-19 detection assay with diagnostic sensitivity and specificity comparable to RT-qPCR, particularly in samples with high viral load.


Assuntos
COVID-19 , Colorimetria , Liofilização , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , RNA Viral , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , COVID-19/virologia , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , Colorimetria/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Diagnóstico Molecular/métodos , RNA Viral/análise , RNA Viral/genética , Sensibilidade e Especificidade , Kit de Reagentes para Diagnóstico/normas , Teste de Ácido Nucleico para COVID-19/métodos
5.
Mikrochim Acta ; 191(6): 333, 2024 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-38753167

RESUMO

The COVID-19 pandemic has underscored the urgent need for rapid and reliable strategies for early detection of SARS-CoV-2. In this study, we propose a DNA nanosphere-based crosslinking catalytic hairpin assembly (CCHA) system for the rapid and sensitive SARS-CoV-2 RNA detection. The CCHA system employs two DNA nanospheres functionalized with catalytic hairpin assembly (CHA) hairpins. The presence of target SARS-CoV-2 RNA initiated the crosslinking of DNA nanospheres via CHA process, leading to the amplification of fluorescence signals. As a result, the speed of SARS-CoV-2 diagnosis was enhanced by significantly increasing the local concentration of the reagents in a crosslinked DNA product, leading to a detection limit of 363 fM within 5 min. The robustness of this system has been validated in complex environments, such as fetal bovine serum and saliva. Hence, the proposed CCHA system offers an efficient and simple approach for rapid detection of SARS-CoV-2 RNA, holding substantial promise for enhancing COVID-19 diagnosis.


Assuntos
COVID-19 , Limite de Detecção , RNA Viral , SARS-CoV-2 , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , RNA Viral/análise , RNA Viral/genética , Humanos , COVID-19/diagnóstico , COVID-19/virologia , Nanosferas/química , DNA/química , Sequências Repetidas Invertidas , Animais , Teste de Ácido Nucleico para COVID-19/métodos , Bovinos , Reagentes de Ligações Cruzadas/química , Saliva/virologia
6.
Methods Mol Biol ; 2804: 195-206, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753149

RESUMO

Clinical diagnostics of infectious diseases via nucleic acid amplification tests (NAATs) depend on a separate step of isolation of nucleic acids from cells/viruses embedded in complex biological matrices. The most recent example has been reverse transcription polymerase chain reaction (RT-PCR) for amplification and detection of SARS-CoV-2 RNA for COVID-19 diagnostics. Kits for RNA extraction and purification are commercially available; however, their integration with amplification systems is generally lacking, resulting in two separate steps, i.e., sample preparation and amplification. This makes NAATs more time-consuming, requiring skilled personnel, and can increase the likelihood of contamination. Here, we describe a setup and methodology to perform the quick extraction and detection of nucleic acids in an integrated manner. In particular, we focus on the use of an immiscible filtration device for capture, isolation, concentration, amplification, and colorimetric detection of SARS-CoV-2 RNA.


Assuntos
COVID-19 , Filtração , Técnicas de Amplificação de Ácido Nucleico , RNA Viral , SARS-CoV-2 , RNA Viral/isolamento & purificação , RNA Viral/análise , RNA Viral/genética , Humanos , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Amplificação de Ácido Nucleico/instrumentação , COVID-19/diagnóstico , COVID-19/virologia , Filtração/instrumentação , Filtração/métodos , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação , Colorimetria/métodos , Colorimetria/instrumentação
7.
PLoS One ; 19(5): e0301234, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38728290

RESUMO

Nucleic Acid Lateral Flow Assays (NALFAs) are a promising solution for the point-of-care detection of viruses like SARS-CoV-2. However, they show some drawbacks, such as the great dependency on the use of antibodies and the need for post-amplification protocols that enable the preparation of amplicons for effective readings, as well as low sensitivity. Here, we developed amplicons of a specific SARS-CoV-2 gene tailed with single-strand DNA (ssDNA) sequences to hybridize with DNA probes immobilized on the NALFA strips, thus overcoming the aforementioned problems. Results have shown that tailed primers have not compromised the amplification efficiency and allowed the correct detection of the amplicons in the lateral flow strip. This approach has presented a limit of detection (LOD) of 25 RNA copies /reaction mix (1 copy/µL) and the test of cross-reactivity with other related viruses has not shown any cross-reactivity. Twenty clinical samples were evaluated by NALFA and simultaneously compared with the gold standard RT-qPCR protocol, originating equal results. Although the number of clinical specimens tested being relatively small, this indicates a sensitivity and specificity both of 100%. In short, an alternative NALFA was successfully implemented, rendering an accurate route for SARS-CoV-2 diagnosis, compatible with low-resource settings.


Assuntos
COVID-19 , RNA Viral , SARS-CoV-2 , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Humanos , COVID-19/diagnóstico , COVID-19/virologia , RNA Viral/genética , Limite de Detecção , Técnicas de Amplificação de Ácido Nucleico/métodos , Sensibilidade e Especificidade , Teste de Ácido Nucleico para COVID-19/métodos , DNA de Cadeia Simples/genética , Primers do DNA/genética , Sondas de DNA
8.
Sci Rep ; 14(1): 10923, 2024 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-38740976

RESUMO

Though pooling samples for SARS-CoV-2 detection has effectively met the need for rapid diagnostic and screening tests, many factors can influence the sensitivity of a pooled test. In this study, we conducted a simulation experiment to evaluate modes of pooling specimens and aimed at formulating an optimal pooling strategy. We focussed on the type of swab, their solvent adsorption ability, pool size, pooling volume, and different factors affecting the quality of preserving RNA by different virus solutions. Both quantitative PCR and digital PCR were used to evaluate the sampling performance. In addition, we determined the detection limit by sampling which is simulated from the virus of different titers and evaluated the effect of sample-storage conditions by determining the viral load after storage. We found that flocked swabs were better than fibre swabs. The RNA-preserving ability of the non-inactivating virus solution was slightly better than that of the inactivating virus solution. The optimal pooling strategy was a pool size of 10 samples in a total volume of 9 mL. Storing the collected samples at 4 °C or 25 °C for up to 48 h had little effect on the detection sensitivity. Further, we observed that our optimal pooling strategy performed equally well as the single-tube test did. In clinical applications, we recommend adopting this pooling strategy for low-risk populations to improve screening efficiency and shape future strategies for detecting and managing other respiratory pathogens, thus contributing to preparedness for future public health challenges.


Assuntos
COVID-19 , RNA Viral , SARS-CoV-2 , Manejo de Espécimes , Humanos , COVID-19/diagnóstico , COVID-19/virologia , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , Manejo de Espécimes/métodos , RNA Viral/genética , Teste de Ácido Nucleico para COVID-19/métodos , Carga Viral/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sensibilidade e Especificidade , Teste para COVID-19/métodos
9.
Lancet Microbe ; 5(5): e468-e477, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38621394

RESUMO

BACKGROUND: Sequencing of SARS-CoV-2 from rapid diagnostic tests (RDTs) can bolster viral genomic surveillance efforts; however, approaches to maximise and standardise pathogen genome recovery from RDTs remain underdeveloped. We aimed to systematically optimise the elution of genetic material from RDT components and to evaluate the efficacy of RDT sequencing for outbreak investigation. METHODS: In this laboratory and cohort-based study we seeded RDTs with inactivated SARS-CoV-2 to optimise the elution of genomic material from RDT lateral flow strips. We measured the effect of changes in buffer type, time in buffer, and rotation on PCR cycle threshold (Ct) value. We recruited individuals older than 18 years residing in the greater Boston area, MA, USA, from July 18 to Nov 5, 2022, via email advertising to students and staff at Harvard University, MA, USA, and via broad social media advertising. All individuals recruited were within 5 days of a positive diagnostic test for SARS-CoV-2; no other relevant exclusion criteria were applied. Each individual completed two RDTs and one PCR swab. On Dec 29, 2022, we also collected RDTs from a convenience sample of individuals who were positive for SARS-CoV-2 and associated with an outbreak at a senior housing facility in MA, USA. We extracted all returned PCR swabs and RDT components (ie, swab, strip, or buffer); samples with a Ct of less than 40 were subject to amplicon sequencing. We compared the efficacy of elution and sequencing across RDT brands and components and used RDT-derived sequences to infer transmission links within the outbreak at the senior housing facility. We conducted metagenomic sequencing of negative RDTs from symptomatic individuals living in the senior housing facility. FINDINGS: Neither elution duration of greater than 10 min nor rotation during elution impacted viral titres. Elution in Buffer AVL (Ct=31·4) and Tris-EDTA Buffer (Ct=30·8) were equivalent (p=0·34); AVL outperformed elution in lysis buffer and 50% lysis buffer (Ct=40·0, p=0·0029 for both) as well as Universal Viral Transport Medium (Ct=36·7, p=0·079). Performance of RDT strips was poorer than that of matched PCR swabs (mean Ct difference 10·2 [SD 4·3], p<0·0001); however, RDT swabs performed similarly to PCR swabs (mean Ct difference 4·1 [5·2], p=0·055). No RDT brand significantly outperformed another. Across sample types, viral load predicted the viral genome assembly length. We assembled greater than 80% complete genomes from 12 of 17 RDT-derived swabs, three of 18 strips, and four of 11 residual buffers. We generated outbreak-associated SARS-CoV-2 genomes using both amplicon and metagenomic sequencing and identified multiple introductions of the virus that resulted in downstream transmission. INTERPRETATION: RDT-derived swabs are a reasonable alternative to PCR swabs for viral genomic surveillance and outbreak investigation. RDT-derived lateral flow strips yield accurate, but significantly fewer, viral reads than matched PCR swabs. Metagenomic sequencing of negative RDTs can identify viruses that might underlie patient symptoms. FUNDING: The National Science Foundation, the Hertz Foundation, the National Institute of General Medical Sciences, Harvard Medical School, the Howard Hughes Medical Institute, the US Centers for Disease Control and Prevention, the Broad Institute and the National Institute of Allergy and Infectious Diseases.


Assuntos
COVID-19 , Genoma Viral , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , COVID-19/virologia , COVID-19/epidemiologia , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Estudos de Coortes , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Genoma Viral/genética , Idoso , Teste para COVID-19/métodos , Testes Diagnósticos de Rotina/métodos , Teste de Ácido Nucleico para COVID-19/métodos , Adulto Jovem , Testes de Diagnóstico Rápido
10.
PLoS Pathog ; 20(4): e1012171, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38683864

RESUMO

Researchers and clinicians often rely on molecular assays like PCR to identify and monitor viral infections, instead of the resource-prohibitive gold standard of viral culture. However, it remains unclear when (if ever) PCR measurements of viral load are reliable indicators of replicating or infectious virus. The recent popularity of PCR protocols targeting subgenomic RNA for SARS-CoV-2 has caused further confusion, as the relationships between subgenomic RNA and standard total RNA assays are incompletely characterized and opinions differ on which RNA type better predicts culture outcomes. Here, we explore these issues by comparing total RNA, subgenomic RNA, and viral culture results from 24 studies of SARS-CoV-2 in non-human primates (including 2167 samples from 174 individuals) using custom-developed Bayesian statistical models. On out-of-sample data, our best models predict subgenomic RNA positivity from total RNA data with 91% accuracy, and they predict culture positivity with 85% accuracy. Further analyses of individual time series indicate that many apparent prediction errors may arise from issues with assay sensitivity or sample processing, suggesting true accuracy may be higher than these estimates. Total RNA and subgenomic RNA showed equivalent performance as predictors of culture positivity. Multiple cofactors (including exposure conditions, host traits, and assay protocols) influence culture predictions, yielding insights into biological and methodological sources of variation in assay outcomes-and indicating that no single threshold value applies across study designs. We also show that our model can accurately predict when an individual is no longer infectious, illustrating the potential for future models trained on human data to guide clinical decisions on case isolation. Our work shows that meta-analysis of in vivo data can overcome longstanding challenges arising from limited sample sizes and can yield robust insights beyond those attainable from individual studies. Our analytical pipeline offers a framework to develop similar predictive tools in other virus-host systems, including models trained on human data, which could support laboratory analyses, medical decisions, and public health guidelines.


Assuntos
COVID-19 , RNA Viral , SARS-CoV-2 , Carga Viral , Animais , SARS-CoV-2/genética , COVID-19/virologia , COVID-19/diagnóstico , RNA Viral/genética , Primatas/virologia , Teorema de Bayes , Humanos , Reação em Cadeia da Polimerase/métodos , Teste de Ácido Nucleico para COVID-19/métodos
11.
J Clin Virol ; 172: 105674, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38643722

RESUMO

BACKGROUND: Rapid and accurate detection of viral respiratory infections is important for infection control measures. This study compares the analytical and clinical performance of the Xpert® Xpress CoV-2/Flu/RSV plus test ("Xpert", Cepheid) and the STANDARD™ M10 Flu/RSV/SARS-CoV-2 test ("M10", SD Biosensor). Both tests are quadruplex RT-PCR assays for rapid diagnosis of SARS-CoV-2, influenza A/B and RSV. STUDY DESIGN: Analytical sensitivities were determined by limit of detection for SARS-CoV-2, influenza A, influenza B and RSV, respectively. Additionally, the clinical performance of the Xpert and the M10 tests was evaluated against standard-of-care RT-PCR by testing of 492 clinical specimens. RESULTS: The analytical sensitivities for Xpert versus M10 test was 10, 50, 50 and 300 versus 300, 200, 800 and 1500 copies/mL for SARS-CoV-2, influenza A, influenza B and RSV, respectively. Clinical sensitivity for the Xpert test was superior across all four pathogens compared to the M10 test. Xpert showed clinical sensitivity of 100 % in all Ct-ranges for all four pathogens whereas M10 showed clinical sensitivity of 100 % in the 25-30 Ct-range, 84-100 % in the 30-35 Ct-range and 47-67 % in the >35 Ct-range across the four pathogens. Translating into real-life clinical sensitivity, the Xpert would detect 100 % of all four pathogens, whereas M10 would detect 92.1, 92.4, 84.8 and 94.7 % for SARS-CoV-2, influenza A, influenza B and RSV. CONCLUSION: This study demonstrates improved analytical and clinical performance of Xpert Xpress CoV-2/Flu/RSV plus compared to STANDARD M10 Flu/RSV/SARS-CoV-2, which is important for ensuring accuracy of diagnosis at all stages of a respiratory infection.


Assuntos
COVID-19 , Vírus da Influenza A , Vírus da Influenza B , Influenza Humana , Infecções por Vírus Respiratório Sincicial , SARS-CoV-2 , Sensibilidade e Especificidade , Humanos , COVID-19/diagnóstico , COVID-19/virologia , Influenza Humana/diagnóstico , Influenza Humana/virologia , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Vírus da Influenza B/isolamento & purificação , Vírus da Influenza B/genética , Vírus da Influenza A/isolamento & purificação , Vírus da Influenza A/genética , Infecções por Vírus Respiratório Sincicial/diagnóstico , Infecções por Vírus Respiratório Sincicial/virologia , Testes Imediatos , Teste de Ácido Nucleico para COVID-19/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Vírus Sincicial Respiratório Humano/genética , Vírus Sincicial Respiratório Humano/isolamento & purificação
13.
Talanta ; 274: 126009, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38579420

RESUMO

Nucleic acid detection is conducive to preventing the spread of COVID-19 pandemic. In this work, we successfully designed a soft interface confined DNA walker by anchoring hairpin reporter probes on cell membranes for the detection of SARS-CoV-2 variants. In the presence of target RNA, the cyclic self-assembly reaction occurred between hairpin probes H1 and H2, and the continuous walking of target RNA on cell membranes led to the gradual amplification of fluorescence signal. The enrichment of H1 on membranes and the unique fluidity of membranes promoted the collision efficiency between DNA strands in the reaction process, endowing this method with high sensitivity. In addition, the double-blind test of synthetic RNA in 5% normal human serum demonstrated the good stability and anti-interference in complex environment of this method, which exhibited great potential in clinical diagnostics.


Assuntos
COVID-19 , SARS-CoV-2 , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Humanos , COVID-19/diagnóstico , COVID-19/virologia , RNA Viral/genética , RNA Viral/análise , DNA/química , DNA/análise , Limite de Detecção , Teste de Ácido Nucleico para COVID-19/métodos
14.
Biosens Bioelectron ; 257: 116292, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38653014

RESUMO

We report the development and initial validation of a paper-based nucleic acid testing platform that integrates Loop-mediated isothermal amplification (LAMP) with clustered regularly interspaced short palindromic repeats (CRISPR) technology, referred to as PLACID (Paper-based LAMP-CRISPR Integrated Diagnostics). LAMP eliminates the need for thermal cycling, resulting in simplified instrumentation, and the CRISPR-associated protein (Cas 12a) system eliminates false positive signals from LAMP products, resulting in highly selective and sensitive assays. We optimized the assay to perform both amplification and detection entirely on paper, eliminating the need for complex fluid handling steps and lateral flow assay transfers. Additionally, we engineered a smartphone-operated system that includes a low-powered, non-contact IR heating chamber to actuate paper-based LAMP and CRISPR reactions and enable the detection of fluorescent signals from the paper. The platform demonstrates high specificity and sensitivity in detecting nucleic acid targets with a limit of detection of 50 copies/µL. We integrate an equipment-free sample preparation separation technology designed to streamline the preparation of crude samples prior to nucleic acid testing. The practical utility of our platform is demonstrated by the successful detection of spiked SARS-CoV-2 RNA fragments in saliva, E. Coli in soil, and pathogenic E. Coli in clinically fecal samples of infected patients. Furthermore, we demonstrate that the paper-based LAMP CRISPR chips employed in our assays possess a shelf life of several weeks, establishing them as viable candidates for on-site diagnostics.


Assuntos
Técnicas Biossensoriais , COVID-19 , Sistemas CRISPR-Cas , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Papel , SARS-CoV-2 , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Humanos , Técnicas Biossensoriais/métodos , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , COVID-19/diagnóstico , COVID-19/virologia , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/instrumentação , Sistemas CRISPR-Cas/genética , Limite de Detecção , Repetições Palindrômicas Curtas Agrupadas e Regularmente Espaçadas/genética , Desenho de Equipamento , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação , Escherichia coli/genética , Escherichia coli/isolamento & purificação , Proteínas Associadas a CRISPR/genética , Smartphone
15.
Microbiol Spectr ; 12(5): e0407323, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38567975

RESUMO

Antigen-based rapid diagnostic tests (Ag-RDTs) were widely deployed to enhance SARS-CoV-2 testing capacity during the COVID-19 pandemic. Consistent with national guidance for low prevalence settings, positive Ag-RDTs were confirmed using nucleic acid amplification tests (NAATs) to avoid false positive results. However, increasing demands for positive Ag-RDT confirmation competed with other testing priorities in clinical laboratories. This work hypothesized that real-time RT-PCR without nucleic acid extraction (NAE) would be sufficiently sensitive to support positive Ag-RDT confirmation. Ag-RDT and NAAT results from community-based asymptomatic testing sites prior to the omicron variant wave were compared to calculate the weekly false positive rate (FPR) and false detection rate (FDR). Real-time RT-PCR was compared with and without NAE using 752 specimens previously tested positive for SARS-CoV-2 using commercial NAATs and 344 specimens from Ag-RDT-positive individuals. The impact of SARS-CoV-2 prevalence on laboratory resources required to sustain Ag-RDT confirmation was modeled for the RT-PCR with and without NAE. Overall, FPR was low [0.07% (222/330,763)] in asymptomatic testing sites, but FDR was high [30.7% (222/724)]. When RT-PCR was compared with and without NAE, 100% concordance was obtained with NAAT-positive specimens, including those from Ag-RDT-positive individuals. NAE-free RT-PCR significantly reduced time to results, human resources, and overall costs. A 30.7% FDR reaffirms the need for NAAT-based confirmation of positive Ag-RDT results during low SARS-CoV-2 prevalence. NAE-free RT-PCR was shown to be a simple and cost-sparing NAAT-based solution for positive Ag-RDT confirmation, and its implementation supported data-driven broader Ag-RDT deployment into communities, workplaces, and households. IMPORTANCE: Rapid antigen testing for SARS-CoV-2 was widely deployed during the COVID-19 pandemic. In settings of low prevalence, national guidance recommends that positive antigen test results be confirmed with molecular testing. Given the high testing burden on clinical laboratories during the COVID-19 pandemic, the high volume of positive antigen tests submitted for confirmatory testing posed challenges for laboratory workflow. This study demonstrated that a simple PCR method without prior nucleic acid purification is an accurate and cost-effective solution for positive rapid antigen test confirmation. Implementing this method allowed molecular confirmatory testing for positive antigen tests to be sustained as antigen testing was expanded into large populations such as workplaces, schools, and households.


Assuntos
Antígenos Virais , COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , COVID-19/epidemiologia , SARS-CoV-2/genética , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade , Prevalência , Reações Falso-Positivas , Teste Sorológico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos
16.
Diagn Microbiol Infect Dis ; 109(2): 116287, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38574444

RESUMO

BACKGROUND: The study aimed to construct a standardized quality control management procedure (QCMP) and access its accuracy in the quality control of COVID-19 reverse transcriptase-polymerase chain reaction (RT-PCR). METHODS: Considering the initial RT-PCR results without applying QCMP as the gold standard, a large-scale diagnostic accuracy study including 4,385,925 participants at three COVID-19 RT-PCR testing sites in China, Foshan (as a pilot test), Guangzhou and Shenyang (as validation sites), was conducted from May 21, 2021, to December 15, 2022. RESULTS: In the pilot test, the RT-PCR with QCMP had a high accuracy of 99.18% with 100% specificity, 100% positive predictive value (PPV), and 99.17% negative predictive value (NPV). The rate of retesting was reduced from 1.98% to 1.16%. Its accuracy was then consistently validated in Guangzhou and Shenyang. CONCLUSIONS: The RT-PCR with QCMP showed excellent accuracy in identifying true negative COVID-19 and relieved the labor and time spent on retesting.


Assuntos
COVID-19 , Controle de Qualidade , SARS-CoV-2 , Sensibilidade e Especificidade , Humanos , China , COVID-19/diagnóstico , COVID-19/prevenção & controle , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/normas , Reação em Cadeia da Polimerase Via Transcriptase Reversa/normas , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Projetos Piloto
17.
Viruses ; 16(4)2024 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-38675941

RESUMO

The BIOFIRE SPOTFIRE Respiratory (R) Panel is a novel, in vitro diagnostic PCR assay with 15 pathogen targets. The runtime is about 15 min which is the shortest among similar panels in the market. We evaluated the performance of the SPOTFIRE R Panel with 151 specimens, including 133 collected from the upper respiratory tract (URT), 13 from the lower respiratory tract (LRT) and 5 external quality assessment program (EQAP) samples. The respiratory specimens were enrolled throughout the first two post-COVID-19 influenza seasons in Hong Kong (March to December 2023). For URT specimens, full concordance was observed between the SPOTFIRE R Panel and the standard-of-care FilmArray Respiratory 2.1 plus Panel (RP2.1plus) for 109 specimens (109/133, 81.95%). After discrepant analysis, the SPOTFIRE R Panel identified more pathogens than the RP2.1plus in 15 specimens and vice versa in 3 specimens. The per-target negative and positive percentage agreement (NPA and PPA) were 92.86-100% except the PPA of adenovirus (88.24%). For LRT and EQAP samples, all results were fully concordant. To conclude, the performance of the SPOTFIRE R Panel was comparable to the RP2.1plus.


Assuntos
COVID-19 , Infecções Respiratórias , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , COVID-19/virologia , Infecções Respiratórias/virologia , Infecções Respiratórias/diagnóstico , Hong Kong , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade , Técnicas de Diagnóstico Molecular/métodos , Teste de Ácido Nucleico para COVID-19/métodos
18.
J AOAC Int ; 107(3): 519-528, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38310327

RESUMO

Since 2019 the world has been in a combat with the highly contagious disease COVID-19 which is caused by the rapid transmission of the SARS-CoV-2 virus (severe acute respiratory syndrome coronavirus 2). Detection of this disease in an early stage helps to control its spread and management. To combat this epidemic with one-time effective medication, improved quick analytical procedures must be developed and validated. The requirement for accurate and precise analytical methods for the diagnosis of the virus and antibodies in infected patients has been a matter of concern. The global impact of this virus has motivated scientists and researchers to investigate and develop various analytical diagnostic techniques. This review includes the study of standard methods which are reliable and accredited for the analytical recognition of the said virus. For early detection of SARS-CoV-2 RNA, RT-PCR (Real-time reverse transcriptase-polymerase chain reaction) is an accurate method among other methods and, thus, considered as the "gold standard" technique. Here, we outline the most extensively used analytical methods for diagnosing COVID-19, along with a brief description of each technique and its analytical aspects/perspective.


Assuntos
COVID-19 , RNA Viral , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , COVID-19/virologia , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , RNA Viral/análise , RNA Viral/genética , Teste para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/métodos
20.
Arq. ciências saúde UNIPAR ; 27(3): 1322-1333, 2023.
Artigo em Português | LILACS | ID: biblio-1426547

RESUMO

Introdução: Com a emergência do SARS-CoV-2 foi disponibilizado uma grande quantidade de ferramentas de diagnóstico. Neste contexto, a falta de vacina, de tratamento e o grande número de casos graves e morte, possibilitou a aprovação emergencial de diversos testes, que ainda necessitam de estudos populacionais para seu registro definitivo. Objetivo: Realizar uma revisão de literatura para avaliar as metodologias de diagnóstico disponíveis no Brasil, de acordo com a realidade local de saúde, explorando o momento epidemiológico a complexidade do teste e a finalidade da sua aplicação. Metodologia: Trata-se de um estudo bibliográfico, descritivo do tipo revisão de literatura. Foram utilizadas as seguintes bases de dados científicos para buscas: PUBMED, MEDLINE, LILACS E COCHRANE LIBRARY, através de descritores selecionados na plataforma DECS. Resultados: O cenário de diversos ensaios, baseados em diferentes metodologias, como os testes baseados em RNA viral, em detecção de antígenos virais ou de anticorpos, associados ao conhecimento da história natural do vírus, possibilita uma análise crítica do melhor diagnóstico de acordo com a clínica do paciente, os epidemiológicos, o objetivo do diagnóstico e a acurácia do ensaio. Atualmente, há mudança no padrão imunológico da população e a descrição de tipos e subtipos de SARS-CoV-2 com mudanças gênicas, que podem levar a mudanças na acurácia diagnóstica ou a re-emergência em surtos de doença grave. Conclusão: Ainda é incerto o caminho evolutivo da história natural da Covid-19 e os ensaios diagnósticos estão em diferentes estágios de desenvolvimento, validação e produção e cada tipo de teste tem suas próprias vantagens e desvantagens distintas inerentes a plataforma tecnológica de origem e uma combinação de tipos de testes usados em momentos diferentes pode ser útil para a condução clínica dos pacientes e no controle da pandemia por SARS-CoV-2.


Introduction: With the emergence of SARS-CoV-2, a large number of diagnostic tools were made available. In this context, the lack of vaccine, treatment and the large number of severe cases and death, allowed the emergency approval of several tests, which still require population studies for their definitive registration. Objective: To carry out a literature review to evaluate the diagnostic methodologies available in Brazil, according to the local health reality, exploring the epidemiological moment, the complexity of the test and the purpose of its application. Methodology: This is a bibliographic, descriptive study of the literature review type. The following scientific databases were used for searches: PUBMED, MEDLINE, LILACS AND COCHRANE LIBRARY, through selected descriptors on the DECS platform. Results: The scenario of several tests, based on different methodologies, such as tests based on viral RNA, on detection of viral antigens or antibodies, associated with knowledge of the natural history of the virus, allows a critical analysis of the best diagnosis according to the patient's clinical, epidemiological, diagnostic objective and assay accuracy. Currently, there is a change in the immune pattern of the population and the description of types and subtypes of SARS-CoV-2 with genetic changes, which can lead to changes in diagnostic accuracy or the re-emergence in outbreaks of severe disease. Conclusion: The evolutionary path of the natural history of Covid-19 is still uncertain and diagnostic assays are at different stages of development, validation and production and each type of test has its own distinct advantages and disadvantages inherent in the technology platform of origin and a combination of types of tests used at different times can be useful for the clinical management of patients and in the control of the SARS-CoV-2 pandemic.


Introducción: Con la aparición del SARS-CoV-2, se dispuso de un gran número de herramientas diagnósticas. En este contexto, la falta de vacuna, tratamiento y el gran número de casos graves y muerte, permitieron la aprobación de urgencia de varias pruebas, que aún requieren estudios poblacionales para su registro definitivo. Objetivo: Realizar una revisión bibliográfica para evaluar las metodologías diagnósticas disponibles en Brasil, de acuerdo con la realidad sanitaria local, explorando el momento epidemiológico, la complejidad de la prueba y la finalidad de su aplicación. Metodología: Se trata de un estudio bibliográfico, descriptivo, del tipo revisión de literatura. Para las búsquedas se utilizaron las siguientes bases de datos científicas PUBMED, MEDLINE, LILACS Y COCHRANE LIBRARY, a través de descriptores seleccionados en la plataforma DECS. Resultados: El escenario de varias pruebas, basadas en diferentes metodologías, como pruebas basadas en el ARN viral, en la detección de antígenos virales o anticuerpos, asociado al conocimiento de la historia natural del virus, permite un análisis crítico del mejor diagnóstico de acuerdo con la clínica del paciente, epidemiológica, objetivo diagnóstico y precisión de la prueba. Actualmente, hay un cambio en el patrón inmunológico de la población y la descripción de tipos y subtipos de SARS-CoV-2 con cambios genéticos, que pueden conducir a cambios en la precisión diagnóstica o la reaparición en brotes de enfermedad grave. Conclusiones: El camino evolutivo de la historia natural del Covid-19 es aún incierto y los ensayos de diagnóstico se encuentran en diferentes etapas de desarrollo, validación y producción y cada tipo de prueba tiene sus propias ventajas y desventajas distintas inherentes a la plataforma tecnológica de origen y una combinación de tipos de pruebas utilizadas en diferentes momentos puede ser útil para el manejo clínico de los pacientes y en el control de la pandemia de SARS- CoV-2.


Assuntos
Revisões Sistemáticas como Assunto , Teste Sorológico para COVID-19/métodos , Teste para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/métodos , Pesquisa sobre Serviços de Saúde , Anticorpos/análise , Antígenos/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA