Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80.273
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 25(1): 397, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773452

RESUMO

BACKGROUND: This study aimed to evaluate the biomechanical effects of reinserted or revised subaxial cervical vertebral screws. METHODS: The first part aimed to gauge the maximum insertional torque (MIT) of 30 subaxial cervical vertebrae outfitted with 4.0-mm titanium screws. A reinsertion group was created wherein a screw was wholly removed and replaced along the same trajectory to test its maximum pullout strength (MPOS). A control group was also implemented. The second part involved implanting 4.0-mm titanium screws into 20 subaxial cervical vertebrae, testing them to failure, and then reinserting 4.5-mm revision screws along the same path to determine and compare the MIT and MPOS between the test and revision groups. RESULTS: Part I findings: No significant difference was observed in the initial insertion's maximum insertion torque (MIT) and maximum pull-out strength (MPOS) between the control and reinsertion groups. However, the MIT of the reinsertion group was substantially decreased compared to the first insertion. Moderate to high correlations were observed between the MIT and MPOS in both groups, as well as between the MIT of the first and second screw in the reinsertion group. Part II, the MIT and MPOS of the screw in the test group showed a strong correlation, while a modest correlation was observed for the revision screw used in failed cervical vertebrae screw. Additionally, the MPOS of the screw in the test group was significantly higher than that of the revision screw group. CONCLUSION: This study suggests that reinsertion of subaxial cervical vertebrae screws along the same trajectory is a viable option that does not significantly affect fixation stability. However, the use of 4.5-mm revision screws is inadequate for failed fixation cases with 4.0-mm cervical vertebral screws.


Assuntos
Parafusos Ósseos , Vértebras Cervicais , Torque , Vértebras Cervicais/cirurgia , Vértebras Cervicais/diagnóstico por imagem , Humanos , Fenômenos Biomecânicos , Masculino , Feminino , Reoperação , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Pessoa de Meia-Idade , Adulto , Idoso , Titânio , Teste de Materiais
2.
BMC Oral Health ; 24(1): 586, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773502

RESUMO

BACKGROUND: Cement spacer is essential for compensating deformation of zirconia restoration after sintering shrinkage, allowing proper seating and better fracture resistance of the restoration. Studies assessing the effect of cement spacer on fit accuracy and fracture strength of zirconia frameworks are missing in the literature. Therefore, the aim of this study was to evaluate the effect of different cement spacer settings on fit accuracy and fracture strength of 3-unit and 4-unit zirconia frameworks. METHODS: Sixty standardized stainless-steel master dies were manufactured with 2 prepared abutments for fabricating 3-unit and 4-unit zirconia frameworks. The frameworks were assigned into 6 groups (n = 10) according to cement spacer setting (30 µm, 50 µm, and 80 µm) as follows: 3-unit frameworks; 3u-30, 3u-50, 3u-80, and 4-unit frameworks; 4u-30, 4u-50, and 4u-80. The frameworks were assessed for fit accuracy with the replica method. The specimens were cemented to their corresponding dies, and the fracture strength was measured in a universal testing machine. The Weibull parameters were calculated for the study groups and fractured specimens were inspected for failure mode. Two-Way ANOVA followed by Tukey test for pairwise comparison between study groups (α = 0.05). RESULTS: The cement spacer had a significant effect on both fit accuracy and fracture strength for 3-unit and 4-unit frameworks. The 50 µm spacer had significantly better fit accuracy followed by 80 µm, and 30 µm spacers. Both 50 µm and 80 µm spacers had similar fracture strength, and both had significantly better strength than 30 µm spacer. CONCLUSIONS: For both 3-unit and 4-unit zirconia frameworks, 50 µm cement spacer can be recommended over 30 µm and 80 µm spacers for significantly better fit accuracy and adequate fracture strength.


Assuntos
Análise do Estresse Dentário , Teste de Materiais , Zircônio , Zircônio/química , Cimentos Dentários/química , Falha de Restauração Dentária , Humanos , Cimentação/métodos
3.
J Biomed Mater Res B Appl Biomater ; 112(6): e35415, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38773744

RESUMO

This study reports the synthesis and characterization of hydroxyapatite (HA)-based bio-composites reinforced with varying amounts (by weight, 1-15 wt.%) of bio-medium entropy alloy (BioMEA) for load-bearing implant applications. BioMEA powders consisting of Ti, Nb, Zr, and Mo were mechanically alloyed for 100 h and subsequently added to HA using powder metallurgy techniques. To show the effect of BioMEA, the microstructure, density, and mechanical tests have been conducted and the synthesized BioMEA was characterized by scanning electron microscope (SEM), x-ray diffractometer (XRD), and Fourier-transform infrared spectroscopy (FTIR) analysis. In addition, in vitro degradation behavior and bioactivity analyses of bio-composites have been conducted. XRD analysis revealed the formation of BioMEA after 20 h of mechanical alloying. The highest density value of 2.47 g/cm3 was found in 15 wt.% BioMEA-reinforced bio-composite. The addition of BioMEA reinforcement led to a significant increase in hardness and tensile strength values, with the highest values observed at 15 wt.% reinforcement. Compression tests demonstrated a significant increase in compressive strength and deformation capability of the bio-composites with the highest values observed at 15 wt.% BioMEA addition. The highest toughness of 7.68 kJ/m2 was measured in 10 wt.% MEA-reinforced bio-composites. The produced bio-composite materials have an elastic modulus between 3.5-5.5 GPa, which may provide a solution to the stress shielding problems caused by the high elastic modulus of metallic implant materials. The most severe degradation occurred in 15 wt.% MEA-reinforced bio-composites, and the effect of degradation caused a decrease in Ca and an increase in Ti-Ni-Zr-Mo in all bio-composites. These findings suggest that HA/BioMEA bio-composites have the potential to be developed as advanced biomaterials with moderate mechanical and biological properties for load-bearing implant applications.


Assuntos
Ligas , Durapatita , Teste de Materiais , Titânio , Zircônio , Zircônio/química , Durapatita/química , Ligas/química , Titânio/química , Entropia , Nióbio/química , Materiais Biocompatíveis/química
4.
J Appl Oral Sci ; 32: e20230440, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38775557

RESUMO

This study aimed to compare the quality of root canal obturation (ratio of area occupied by gutta-percha (G), sealer (S), and presence of voids (V)) in different anatomical irregularities (intercanal communications, lateral irregularities, and accessory canals) located at different thirds of the root canal system of mandibular molar replicas. Sixty-seven 3D printed replicas of an accessed mandibular molar were prepared using ProGlider and ProTaper Gold rotatory systems. Three specimens were randomly selected to be used as controls and did not receive further treatment. The rest were randomly distributed in 4 experimental groups to be obturated using either cold lateral compaction (LC), continuous wave of condensation (CW), and core-carrier obturation (ThermafilPlus (TH) or GuttaCore (GC)) (n=16 per group). AHPlus® sealer was used in all groups. The three controls and a specimen from each experimental group were scanned using micro-computed tomography. The rest of the replicas were sectioned at the sites of anatomical irregularities and examined at 30× magnification. The G, S, and V ratios were calculated dividing the area occupied with each element by the total root canal area and then compared among groups using the Kruskal-Wallis test. Voids were present in all obturation techniques with ratios from 0.01 to 0.15. CW obtained a significantly higher G ratio in the irregularity located in the coronal third (0.882) than LC (0.681), TH (0.773), and GC (0.801) (p<0.05). TH and GC achieved significantly higher G ratios in those located in the apical third (p<0.05). The worst quality of obturation was observed in the loop accessory canal with all obturation techniques. Whitin the limitations of this study, it can be concluded that CW and core-carrier obturation are respectively the most effective techniques for obturating anatomical irregularities located in the coronal and the apical third.


Assuntos
Cavidade Pulpar , Guta-Percha , Teste de Materiais , Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular , Microtomografia por Raio-X , Obturação do Canal Radicular/métodos , Materiais Restauradores do Canal Radicular/química , Microtomografia por Raio-X/métodos , Guta-Percha/química , Cavidade Pulpar/anatomia & histologia , Cavidade Pulpar/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes , Valores de Referência , Dente Molar/anatomia & histologia , Resinas Epóxi/química , Impressão Tridimensional , Propriedades de Superfície , Estatísticas não Paramétricas , Distribuição Aleatória
5.
Braz Dent J ; 35: e245616, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38775592

RESUMO

The aim of this in vitro study was to evaluate the potential of different fluoridated varnishes to inhibit the progression of incipient caries lesions after cariogenic challenge. Seventy-five enamel specimens of bovine teeth were prepared and selected based on the initial surface microhardness (SMH). The specimens were first subjected to artificial demineralization (in buffer solution) after which SMH was re-analyzed (SM1). They were then randomly assigned to five experimental groups: 1- CONTROL (pH cycling), 2 - MI VAR (MI Varnish with RECALDENTTM - CPP-ACP), 3 - PROFL (Profluorid®), 4 - CLIN (ClinproTM White Varnish with TCP), and 5 - DUR (Duraphat®) (n=15). The varnishes were applied in a thin layer and the specimens were then subjected to pH cycling for eight days. The SMH and cross-sectional microhardness (CSMH) were then analyzed (SM2). The fluoride and calcium ion concentrations in the solution were analyzed by the indirect method and atomic absorption spectrophotometry, respectively. Data were statistically analyzed by Student's t-test, ANOVA/Tukey-Kramer, or Kruskall-Wallis/Dunn tests for individual comparisons (p˂0.05). All varnishes led to significantly higher surface and subsurface remineralization compared with the control group but did not differ from each other. The varnishes with the highest fluoride release were: PROFL and CLIN, followed by MI VAR and DUR. The varnishes with significantly higher release of calcium were: DUR, CLIN, and PROFL. In conclusion, all commercial fluoridated varnishes tested have good potential to inhibit the progression of demineralization, regardless of the ion release mechanisms.


Assuntos
Cariostáticos , Cárie Dentária , Esmalte Dentário , Progressão da Doença , Fluoretos Tópicos , Dureza , Desmineralização do Dente , Bovinos , Animais , Cárie Dentária/prevenção & controle , Cariostáticos/farmacologia , Esmalte Dentário/efeitos dos fármacos , Desmineralização do Dente/prevenção & controle , Concentração de Íons de Hidrogênio , Cálcio , Distribuição Aleatória , Remineralização Dentária/métodos , Caseínas , Teste de Materiais , Espectrofotometria Atômica , Fluoreto de Sódio
6.
Braz Dent J ; 35: e245720, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38775593

RESUMO

This study evaluated a new method of adhesive system application on the bond strength between fiber post and root dentin using two adhesive systems. The canals of sixty bovine incisors were prepared and obturated. The roots were divided into six groups (n=10) according to the adhesive system (Clearfil SE - CSE and Single Bond Universal - SBU) and the application strategy (microbrush - MB; rotary brush - RB; and ultrasonic tip - US). The glass fiber posts were cemented with resin cement (RelyX ARC). The roots were sectioned perpendicularly to their long axis, and three slices per root were obtained. Previously to the push-out test, confocal laser scanning microscopy (CLSM) was performed to illustrate the interfacial adaptation of the cement to the root canal walls. Failure patterns were analyzed with 40x magnification. Shapiro-Wilk indicated a normal distribution of the data. The bond strength values were compared using one-way ANOVA and Tukey's tests. Student's T test analyzed the differences between the adhesive systems within each third and protocol. A significance level of 5% was used. CSE with RB showed higher mean bond strength values compared to MB (conventional technique) (P < 0.05). US application resulted in intermediate bond strength values for CSE (P > 0.05). The application of SBU using RB generated higher mean bond strength values compared to MB and US (P < 0.05). Adhesive failures were predominant (65.5%). CSE and SBU application with the new rotary brush improved the bond strength of fiber posts to root dentin compared to the conventional strategy.


Assuntos
Dentina , Técnica para Retentor Intrarradicular , Cimentos de Resina , Bovinos , Animais , Cimentos de Resina/química , Colagem Dentária/métodos , Bis-Fenol A-Glicidil Metacrilato/química , Adesivos Dentinários/química , Microscopia Confocal , Ácidos Polimetacrílicos/química , Teste de Materiais , Vidro/química , Raiz Dentária , Polietilenoglicóis/química , Análise do Estresse Dentário
7.
Dental Press J Orthod ; 29(2): e2423282, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38775601

RESUMO

OBJECTIVE: This study aimed to compare the insertion torque (IT), flexural strength (FS) and surface alterations between stainless steel (SS-MIs) and titanium alloy (Ti-MIs) orthodontic mini-implants. METHODS: Twenty-four MIs (2 x 10 mm; SS-MIs, n = 12; Ti-MIs, n = 12) were inserted on artificial bone blocks of 20 lb/ft3 (20 PCF) and 40 lb/ft3 (40 PCF) density. The maximum IT was recorded using a digital torque meter. FS was evaluated at 2, 3 and 4 mm-deflection. Surface topography and chemical composition of MIs were assessed by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). General linear and mixed models were used to assess the effect of the MI type, bone density and deflection on the evaluated outcomes. RESULTS: The IT of Ti-MIs was 1.1 Ncm greater than that obtained for the SS-MIs (p= 0.018). The IT for MIs inserted in 40 PCF test blocks was 5.4 Ncm greater than that for those inserted in 20 PCF test blocks (p < 0.001). SS-MIs inserted in higher density bone (40 PCF) had significantly higher flexural strength than the other groups, at 2 mm (98.7 ± 5.1 Ncm), 3 mm (112.0 ± 3.9 Ncm) and 4 mm (120.0 ± 3.4 Ncm) of deflection (p< 0.001). SEM evidenced fractures in the Ti-MIs. EDS revealed incorporation of 18% of C and 2.06% of O in the loaded SS-MIs, and 3.91% of C in the loaded Ti-MIs. CONCLUSIONS: Based on the findings of this in vitro study, it seems that SS-MIs offer sufficient stability and exhibit greater mechanical strength, compared to Ti-MIs when inserted into higher density bone.


Assuntos
Ligas Dentárias , Implantes Dentários , Resistência à Flexão , Teste de Materiais , Microscopia Eletrônica de Varredura , Procedimentos de Ancoragem Ortodôntica , Aço Inoxidável , Propriedades de Superfície , Titânio , Torque , Titânio/química , Aço Inoxidável/química , Procedimentos de Ancoragem Ortodôntica/instrumentação , Procedimentos de Ancoragem Ortodôntica/métodos , Ligas Dentárias/química , Técnicas In Vitro , Espectrometria por Raios X , Análise do Estresse Dentário , Humanos , Estresse Mecânico , Densidade Óssea
8.
Transl Vis Sci Technol ; 13(5): 19, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38776107

RESUMO

Purpose: We sought to introduce the materials, design, and biocompatibility of a flexible and suturable artificial corneal device. Methods: Single-piece, fully synthetic, optic-skirt design devices were made from compact perfluoroalkoxy alkane. The skirt and the optic wall surfaces were lined with a porous tissue ingrowth material using expanded polytetrafluoroethylene. Full-thickness macroapertures around the skirt perimeter were placed to facilitate nutrition of the recipient cornea. Material properties including the skirt's modulus of elasticity and bending stiffness, optic light transmission, wetting behavior, topical drug penetrance, and degradation profile were evaluated. Results: The final prototype suitable for human use has a transparent optic with a diameter of 4.60 mm anteriorly, 4.28 mm posteriorly, and a skirt outer diameter of 6.8 mm. The biomechanical and optical properties of the device closely align with the native human cornea with an average normalized device skirt-bending stiffness of 4.7 kPa·mm4 and light transmission in the visible spectrum ranging between 92% and 96%. No optical damage was seen in the 36 devices tested in fouling experiments. No significant difference was observed in topical drug penetrance into the anterior chamber of the device implanted eye compared with the naïve rabbit eye. Conclusions: The flexibility and biocompatibility of our artificial cornea device may offer enhanced tissue integration and decreased inflammation, leading to improved retention compared with rigid keratoprosthesis designs. Translational Relevance: We have developed a fully synthetic, flexible, suturable, optic-skirt design prototype artificial cornea that is ready to be tested in early human feasibility studies.


Assuntos
Materiais Biocompatíveis , Córnea , Teste de Materiais , Desenho de Prótese , Animais , Coelhos , Materiais Biocompatíveis/química , Teste de Materiais/métodos , Humanos
9.
J Adhes Dent ; 26(1): 125-134, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38770704

RESUMO

PURPOSE: To investigate the effect of adhesive type and long-term aging on the shear bond strength (SBS) between silica-based ceramics and composite cement (CC). MATERIALS AND METHODS: Lithium-silicate (LS), feldspathic (FD) and polymer-infiltrated ceramic (PIC) blocks were sectioned (10 x 12 x 2 mm) and divided into 24 groups considering the factors: "ceramics" (LS, FD, and PIC), "adhesive" (Ctrl: without adhesive; 2SC: 2-step conventional; 3SC: 3-step conventional; 1SU: 1-step universal), and "aging" (non-aged or aged [A]). After the surface treatments, CC cylinders (n = 15, Ø = 2 mm; height = 2 mm) were made and half of the samples were subjected to thermocycling (10,000) and stored in water at 37°C for 18 months. The samples were submitted to SBS testing (100 kgf, 1 mm/min) and failure analysis. Extra samples were prepared for microscopic analysis of the adhesive interface. SBS (MPa) data was analyzed by 3-way ANOVA and Tukey's test (5%). Weibull analysis was performed on the SBS data. RESULTS: All factors and interactions were significant for SBS (p<0.05). Before aging, there was no significant difference between the tested groups and the respective control groups. After aging, the LS_1SU (22.18 ± 7.74) and LS_2SC (17.32 ± 5.86) groups exhibited significantly lower SBS than did the LS_Ctrl (30.30 ± 6.11). Only the LS_1SU group showed a significant decrease in SBS after aging vs without aging. The LS_1SU (12.20) group showed the highest Weibull modulus, which was significantly higher than LS_2SC_A (2.82) and LS_1SU_A (3.15) groups. CONCLUSION: No type of adhesive applied after silane benefitted the long-term adhesion of silica-based ceramics to CC in comparison to the groups without adhesive.


Assuntos
Cerâmica , Colagem Dentária , Teste de Materiais , Cimentos de Resina , Resistência ao Cisalhamento , Dióxido de Silício , Dióxido de Silício/química , Cerâmica/química , Fatores de Tempo , Cimentos de Resina/química , Desenho Assistido por Computador , Propriedades de Superfície , Análise do Estresse Dentário , Cimentação/métodos , Porcelana Dentária/química , Humanos , Resinas Compostas/química , Cimentos Dentários/química , Compostos de Potássio/química , Silicatos de Alumínio/química , Temperatura
10.
J Adhes Dent ; 26(1): 135-145, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38771025

RESUMO

PURPOSE: To measure zirconia-to-zirconia microtensile bond strength (µTBS) using composite cements with and without primer. MATERIALS AND METHODS: Two Initial Zirconia UHT (GC) sticks (1.8x1.8x5.0 mm) were bonded using four cements with and without their respective manufacturer's primer/adhesive (G-CEM ONE [GOne] and G-Multi Primer, GC; Panavia V5 [Pv5]), and Panavia SA Cement Universal [PSAu], and Clearfil Ceramic Plus, Kuraray Noritake; RelyX Universal (RXu) and Scotchbond Universal Plus [SBUp], 3M Oral Care). Specimens were trimmed to an hour-glass shaped specimen whose isthmus is circular in cross-section. After 1-week water storage, the specimens were either tested immediately (1-week µTBS) or first subjected to 50,000 thermocycles (50kTC-aged µTBS). The fracture mode was categorized as either adhesive interfacial failure, cohesive failure in composite cement, or mixed failure, followed by SEM fracture analysis of selected specimens. Data were analyzed using linear mixed-effects statistics (α = 0.05; variables: composite cement, primer/adhesive application, aging). RESULTS: The statistical analysis revealed no significant differences with aging (p = 0.3662). No significant difference in µTBS with/without primer and aging was recorded for GOne and PSAu. A significantly higher µTBS was recorded for Pv5 and RXu when applied with their respective primer/adhesive. Comparing the four composite cements when they were applied in the manner that resulted in their best performance, a significant difference in 50kTC-aged µTBS was found for PSAu compared to Pv5 and RXu. A significant decrease in µTBS upon 50kTC aging was only recorded for RXu in combination with SBUp. CONCLUSION: Adequate bonding to zirconia requires the functional monomer 10-MDP either contained in the composite cement, in which case a separate 10-MDP primer is no longer needed, or in the separately applied primer/adhesive.


Assuntos
Resinas Compostas , Colagem Dentária , Teste de Materiais , Metacrilatos , Cimentos de Resina , Resistência à Tração , Zircônio , Zircônio/química , Cimentos de Resina/química , Resinas Compostas/química , Metacrilatos/química , Cimentos Dentários/química , Cerâmica/química , Análise do Estresse Dentário , Humanos , Fatores de Tempo , Água/química , Temperatura , Porcelana Dentária/química , Propriedades de Superfície , Materiais Dentários/química , Cimentos de Ionômeros de Vidro
11.
ACS Appl Bio Mater ; 7(5): 3337-3345, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38700956

RESUMO

A stimuli-responsive drug delivery nanocarrier with a core-shell structure combining photothermal therapy and chemotherapy for killing cancer cells was constructed in this study. The multifunctional nanocarrier ReS2@mSiO2-RhB entails an ReS2 hierarchical nanosphere coated with a fluorescent mesoporous silica shell. The three-dimensional hierarchical ReS2 nanostructure is capable of effectively absorbing near-infrared (NIR) light and converting it into heat. These ReS2 nanospheres were generated by a hydrothermal synthesis process leading to the self-assembly of few-layered ReS2 nanosheets. The mesoporous silica shell was further coated on the surface of the ReS2 nanospheres through a surfactant-templating sol-gel approach to provide accessible mesopores for drug uploading. A fluorescent dye (Rhodamine B) was covalently attached to silica precursors and incorporated during synthesis in the mesoporous silica walls toward conferring imaging capability to the nanocarrier. Doxorubicin (DOX), a known cancer drug, was used in a proof-of-concept study to assess the material's ability to function as a drug delivery carrier. While the silica pores are not capped, the drug molecule loading and release take advantage of the pH-governed electrostatic interactions between the drug and silica wall. The ReS2@mSiO2-RhB enabled a drug loading content as high as 19.83 mg/g doxorubicin. The ReS2@mSiO2-RhB-DOX nanocarrier's cumulative drug release rate at pH values that simulate physiological conditions showed significant pH responsiveness, reaching 59.8% at pH 6.8 and 98.5% and pH 5.5. The in vitro testing using HeLa cervical cancer cells proved that ReS2@mSiO2-RhB-DOX has a strong cancer eradication ability upon irradiation with an NIR laser owing to the combined drug delivery and photothermal effect. The results highlight the potential of ReS2@mSiO2-RhB nanoparticles for combined cancer therapy in the future.


Assuntos
Doxorrubicina , Liberação Controlada de Fármacos , Ensaios de Seleção de Medicamentos Antitumorais , Teste de Materiais , Nanopartículas , Tamanho da Partícula , Terapia Fototérmica , Rênio , Dióxido de Silício , Dióxido de Silício/química , Humanos , Doxorrubicina/farmacologia , Doxorrubicina/química , Concentração de Íons de Hidrogênio , Nanopartículas/química , Rênio/química , Rênio/farmacologia , Dissulfetos/química , Porosidade , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Materiais Biocompatíveis/síntese química , Sobrevivência Celular/efeitos dos fármacos , Antineoplásicos/química , Antineoplásicos/farmacologia , Portadores de Fármacos/química , Células HeLa
12.
ACS Appl Bio Mater ; 7(5): 3238-3246, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38700999

RESUMO

As the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) continues its global spread, the exploration of novel therapeutic and diagnostic strategies is still needed. The virus enters host cells by binding the angiotensin-converting enzyme 2 (ACE2) receptor through the spike protein. Here, we develop an engineered, small, stable, and catalytically inactive version of ACE2, termed miniature ACE2 (mACE2), designed to bind the spike protein with high affinity. Employing a magnetic nanoparticle-based assay, we harnessed the strong binding affinity of mACE2 to develop a sensitive and specific platform for the detection or neutralization of SARS-CoV-2. Our findings highlight the potential of engineered mACE2 as a valuable tool in the fight against SARS-CoV-2. The success of developing such a small reagent based on a piecewise molecular design serves as a proof-of-concept approach for the rapid deployment of such agents to diagnose and fight other viral diseases.


Assuntos
Enzima de Conversão de Angiotensina 2 , COVID-19 , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus , Enzima de Conversão de Angiotensina 2/metabolismo , Enzima de Conversão de Angiotensina 2/química , SARS-CoV-2/genética , Humanos , Glicoproteína da Espícula de Coronavírus/metabolismo , Glicoproteína da Espícula de Coronavírus/genética , Glicoproteína da Espícula de Coronavírus/química , COVID-19/virologia , COVID-19/diagnóstico , Teste de Materiais , Engenharia de Proteínas , Ligação Proteica , Nanopartículas de Magnetita/química
13.
ACS Appl Bio Mater ; 7(5): 3330-3336, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38701398

RESUMO

The threat of bacterial infections, especially drug-resistant strains, to human health necessitates the development of high-efficient, broad-spectrum and nonantibiotic nanodisinfectant. However, the effect of interfacial charge on the antibacterial properties of nanodisinfectant remains a mystery, which greatly limits the development of highly antibacterial active nanodisinfectant. Herein, we developed three types of ultrasmall (d < 3 nm) gold-nanoparticles (AuNPs) modified with 5-carboxylic(C)/methoxy(M)amino(A)/-2-mercaptobenzimidazole (C/M/A MB) to investigate their interfacial charge on antibacterial performance. Our results showed that both the electropositive AMB-AuNPs and electronegative CMB-AuNPs exhibited no antibacterial activity against both Gram-positive (G+) and Gram-negative (G-) bacteria. However, the electroneutral MMB-AuNPs exhibited unique antibacterial performance against both G+ and G- bacteria, even against methicillin-resistant Staphylococcus aureus (MRSA). Mechanistic investigation revealed a multipathway synergistic bacteriostatic mechanism involving MMB-AuNPs inducing damage to bacterial cell membranes, disruption of membrane potential and downregulation of ATP levels, ultimately leading to bacterial demise. Furthermore, two additional electroneutral AuNPs modified with 5-methyl-2-mercaptobenzimidazole (mMB-AuNPs) and 5-ethoxy-2-mercaptobenzimidazole (EMB-AuNPs) also demonstrated commendable antibacterial efficacy against E. coli, S. aureus, and MRSA; however, their performance was comparatively inferior to that of MMB-AuNPs. This work provides valuable insights for the development of high-performance antibacterial nanomaterials.


Assuntos
Antibacterianos , Benzimidazóis , Ouro , Nanopartículas Metálicas , Testes de Sensibilidade Microbiana , Tamanho da Partícula , Ouro/química , Ouro/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Antibacterianos/síntese química , Nanopartículas Metálicas/química , Benzimidazóis/química , Benzimidazóis/farmacologia , Teste de Materiais , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Farmacorresistência Bacteriana/efeitos dos fármacos
14.
ACS Appl Bio Mater ; 7(5): 3295-3305, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38701399

RESUMO

Physicochemical properties of nanoparticles, such as particle size, surface charge, and particle shape, have a significant impact on cell activities. However, the effects of surface functionalization of nanoparticles with small chemical groups on stem cell behavior and function remain understudied. Herein, we incorporated different chemical functional groups (amino, DETA, hydroxyl, phosphate, and sulfonate with charges of +9.5, + 21.7, -14.1, -25.6, and -37.7, respectively) to the surface of inorganic silica nanoparticles. To trace their effects on mesenchymal stem cells (MSCs) of rat bone marrow, these functionalized silica nanoparticles were used to encapsulate Rhodamine B fluorophore dye. We found that surface functionalization with positively charged and short-chain chemical groups facilitates cell internalization and retention of nanoparticles in MSCs. The endocytic pathway differed among functionalized nanoparticles when tested with ion-channel inhibitors. Negatively charged nanoparticles mainly use lysosomal exocytosis to exit cells, while positively charged nanoparticles can undergo endosomal escape to avoid scavenging. The cytotoxic profiles of these functionalized silica nanoparticles are still within acceptable limits and tolerable. They exerted subtle effects on the actin cytoskeleton and migration ability. Last, phosphate-functionalized nanoparticles upregulate osteogenesis-related genes and induce osteoblast-like morphology, implying that it can direct MSCs lineage specification for bone tissue engineering. Our study provides insights into the rational design of biomaterials for effective drug delivery and regenerative medicine.


Assuntos
Materiais Biocompatíveis , Teste de Materiais , Células-Tronco Mesenquimais , Nanopartículas , Tamanho da Partícula , Dióxido de Silício , Propriedades de Superfície , Células-Tronco Mesenquimais/efeitos dos fármacos , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/metabolismo , Dióxido de Silício/química , Dióxido de Silício/farmacologia , Nanopartículas/química , Animais , Ratos , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Osteogênese/efeitos dos fármacos
15.
ACS Appl Bio Mater ; 7(5): 3460-3468, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38703374

RESUMO

Trimethylamine N-oxide (TMAO), a molecule produced by the microbiota, has been associated with human health and illness. Its early discovery in body fluids may affect our understanding of the pathophysiology and treatment of many illnesses. Therefore, our knowledge of the pathophysiology and diagnostics of disorders associated with TMAO might be enhanced by the creation of dependable and fast methods for TMAO detection. Therefore, we developed a fluorescent probe for detecting TMAO utilizing an on-off-on strategy. Bovine serum albumin (BSA)@AuNCs luminescence is effectively quenched by Mo4+ because BSA@AuNCs and Mo4+ have a strong binding relationship. Mo4+ ions can substantially decrease the emission intensity of gold nanoclusters by establishing a BSA@AuNCs-Mo system. Then, the luminescence of BSA@AuNCs was restored due to the interaction between Mo4+ and TMAO. A significant linear relationship was seen between the emission intensity and TMAO concentration within the 0-201 µM range, with a detection limit of 1.532 µM. Additionally, the method can measure TMAO in blood and urine samples.


Assuntos
Corantes Fluorescentes , Ouro , Teste de Materiais , Nanopartículas Metálicas , Metilaminas , Tamanho da Partícula , Soroalbumina Bovina , Metilaminas/química , Ouro/química , Soroalbumina Bovina/química , Nanopartículas Metálicas/química , Humanos , Corantes Fluorescentes/química , Materiais Biocompatíveis/química , Bovinos , Animais , Fluorescência , Espectrometria de Fluorescência , Estrutura Molecular
16.
ACS Appl Bio Mater ; 7(5): 2660-2676, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38723276

RESUMO

Wound healing, particularly for chronic wounds, presents a considerable difficulty due to differences in biochemical and cellular processes that occur in different types of wounds. Recent technological breakthroughs have notably advanced the understanding of diagnostic and therapeutic approaches to wound healing. The evolution in wound care has seen a transition from traditional textile dressings to a variety of advanced alternatives, including self-healing hydrogels, hydrofibers, foams, hydrocolloids, environment responsive dressings, growth factor-based therapy, bioengineered skin substitutes, and stem cell and gene therapy. Technological advancements, such as 3D printing and electronic skin (e-skin) therapy, contribute to the customization of wound healing. Despite these advancements, effectively managing chronic wounds remains challenging. This necessitates the development of treatments that consider performance, risk-benefit balance, and cost-effectiveness. This review discusses innovative strategies for the healing of chronic wounds. Incorporating biomarkers into advanced dressings, coupled with corresponding biosensors and drug delivery formulations, enables the theranostic approach to the treatment of chronic wounds. Furthermore, integrating advanced dressings with power sources and user interfaces like near-field communication, radio frequency identification, and Bluetooth enhances real-time monitoring and on-demand drug delivery. It also provides a thorough evaluation of the advantages, patient compliance, costs, and durability of advanced dressings, emphasizing smart formulations and their preparation methods.


Assuntos
Bandagens , Materiais Biocompatíveis , Cicatrização , Humanos , Cicatrização/efeitos dos fármacos , Materiais Biocompatíveis/química , Doença Crônica , Animais , Teste de Materiais
17.
Biomed Mater ; 19(4)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38729187

RESUMO

Bundles of engineered collagen microfibers are promising synthetic tendons as substitutes for autogenous grafts. The purpose of this study was to develop high-speed and continuous spinning of collagen microfibers that involves stretching of collagen stream. Our study revealed the 'critical fibrillogenesis concentration (CFC)' of neutralized collagen solutions, which is defined as the upper limit of the collagen concentration at which neutralized collagen molecules remain stable as long as they are cooled (⩽10 °C). Neutralized collagen solutions at collagen concentrations slightly below the CFC formed cord-like collagen gels comprising longitudinally aligned fibrils when extruded from nozzles into an ethanol bath. Dry collagen microfibers with a controlled diameter ranging from 122 ± 2-31.2 ± 1.7 µm can be spun from the cord-like gels using nozzles of various sizes. The spinning process was improved by including stretching of collagen stream to further reduce diameter and increase linear velocity. We extruded a collagen solution through a 182 µm diameter nozzle while simultaneously stretching it in an ethanol bath during gelation and fiber formation. This process resembles the stretching of a melted thermoplastic resin because it solidifies during melt spinning. The mechanical properties of the stretched collagen microfibers were comparable to the highest literature values obtained using microfluidic wet spinning, as they exhibited longitudinally aligned fibrils both on their surface and in their core. Previous wet spinning methods were unable to generate collagen microfibers with a consistent tendon-like fibrillar arrangement throughout the samples. Although the tangent modulus (137 ± 7 MPa) and stress at break of the swollen bundles of stretched microfibers (13.8 ± 1.9 MPa) were lower than those of human anterior cruciate ligament, they were within the same order of magnitude. We developed a spinning technique that produces narrow collagen microfibers with a tendon-like arrangement that can serve as artificial fiber units for collagen-based synthetic tendons.


Assuntos
Colágeno , Teste de Materiais , Tendões , Engenharia Tecidual , Colágeno/química , Engenharia Tecidual/métodos , Animais , Materiais Biocompatíveis/química , Humanos , Resistência à Tração , Estresse Mecânico , Alicerces Teciduais/química
18.
Int J Artif Organs ; 47(5): 321-328, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38738648

RESUMO

Performance evaluation of new dialysis membranes is primarily performed in vitro, which can lead to differences in clinical results. Currently, data on dialysis membrane performance and safety are available only for haemodialysis patients. Herein, we aimed to establish an in vivo animal model of dialysis that could be extrapolated to humans. We created a bilateral nephrectomy pig model of renal failure, which placed a double-lumen catheter with the hub exposed dorsally. Haemodialysis was performed in the same manner as in humans, during which clinically relevant physiologic data were evaluated. Next, to evaluate the utility of this model, the biocompatibility of two kinds of membranes coated with or without vitamin E used in haemodiafiltration therapy were compared. Haemodialysis treatment was successfully performed in nephrectomized pigs under the same dialysis conditions (4 h per session, every other day, for 2 weeks). In accordance with human clinical data, regular dialysis alleviated renal failure in pigs. The vitamin E-coated membrane showed a significant reduction rate of advanced oxidation protein products during dialysis than non-coated membrane. In conclusion, this model mimics the pathophysiology and dialysis condition of patients undergoing haemodialysis. This dialysis treatment model of renal failure will be useful for evaluating the performance and safety of dialysis membranes.


Assuntos
Modelos Animais de Doenças , Membranas Artificiais , Diálise Renal , Animais , Diálise Renal/instrumentação , Suínos , Vitamina E , Teste de Materiais , Materiais Revestidos Biocompatíveis , Nefrectomia , Hemodiafiltração/instrumentação , Hemodiafiltração/métodos
19.
Clin Oral Investig ; 28(6): 305, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38722356

RESUMO

OBJECTIVE: To evaluate the ability of the water glass treatment to penetrate zirconia and improve the bond strength of resin cement. MATERIAL AND METHODS: Water glass was applied to zirconia specimens, which were then sintered. The specimens were divided into water-glass-treated and untreated zirconia (control) groups. The surface properties of the water-glass-treated specimens were evaluated using surface roughness and electron probe micro-analyser (EPMA) analysis. A resin cement was used to evaluate the tensile bond strength, with2 and without a silane-containing primer. After 24 h in water storage at 37 °C and thermal cycling, the bond strengths were statistically evaluated with t-test, and the fracture surfaces were observed using SEM. RESULTS: The water glass treatment slightly increased the surface roughness of the zirconia specimens, and the EPMA analysis detected the water glass penetration to be 50 µm below the zirconia surface. The application of primer improved the tensile bond strength in all groups. After 24 h, the water-glass-treated zirconia exhibited a tensile strength of 24.8 ± 5.5 MPa, which was significantly higher than that of the control zirconia (17.6 ± 3.5 MPa) (p < 0.05). After thermal cycling, the water-glass-treated zirconia showed significantly higher tensile strength than the control zirconia. The fracture surface morphology was mainly an adhesive pattern, whereas resin cement residue was occasionally detected on the water-glass-treated zirconia surfaces. CONCLUSION: The water glass treatment resulted in the formation of a stable silica phase on the zirconia surface. This process enabled silane coupling to the zirconia and improved the adhesion of the resin cement.


Assuntos
Colagem Dentária , Vidro , Teste de Materiais , Cimentos de Resina , Silanos , Propriedades de Superfície , Resistência à Tração , Água , Zircônio , Zircônio/química , Cimentos de Resina/química , Silanos/química , Água/química , Colagem Dentária/métodos , Vidro/química , Microscopia Eletrônica de Varredura , Análise do Estresse Dentário
20.
Molecules ; 29(9)2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38731508

RESUMO

This study delves into the physicochemical properties of inorganic hydroxyapatite (HAp) and hybrid hydroxyapatite-chitosan (HAp-CTS) granules, also gold-enriched, which can be used as aggregates in biomicroconcrete-type materials. The impact of granules' surface modifications with citric acid (CA) or polyethylene glycol (PEG) was assessed. Citric acid modification induced increased specific surface area and porosity in inorganic granules, contrasting with reduced parameters in hybrid granules. PEG modification resulted in a slight increase in specific surface area for inorganic granules and a substantial rise for hybrid granules with gold nanoparticles. Varied effects on open porosity were observed based on granule type. Microstructural analysis revealed increased roughness for inorganic granules post CA modification, while hybrid granules exhibited smoother surfaces. Novel biomicroconcretes, based on α-tricalcium phosphate (α-TCP) calcium phosphate cement and developed granules as aggregates within, were evaluated for compressive strength. Compressive strength assessments showcased significant enhancement with PEG modification, emphasizing its positive impact. Citric acid modification demonstrated variable effects, depending on granule composition. The incorporation of gold nanoparticles further enriched the multifaceted approach to enhancing calcium phosphate-based biomaterials for potential biomedical applications. This study demonstrates the pivotal role of surface modifications in tailoring the physicochemical properties of granules, paving the way for advanced biomicroconcretes with improved compressive strength for diverse biomedical applications.


Assuntos
Ácido Cítrico , Durapatita , Polietilenoglicóis , Ácido Cítrico/química , Durapatita/química , Polietilenoglicóis/química , Ouro/química , Materiais Biocompatíveis/química , Teste de Materiais , Quitosana/química , Porosidade , Nanopartículas Metálicas/química , Fenômenos Químicos , Força Compressiva , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA