Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48.561
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Biomed Mater ; 19(4)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38740037

RESUMO

The purpose of this study was to construct a rutin-controlled release system on the surface of Ti substrates and investigate its effects on osteogenesis and osseointegration on the surface of implants. The base layer, polyethylenimine (PEI), was immobilised on a titanium substrate. Then, hyaluronic acid (HA)/chitosan (CS)-rutin (RT) multilayer films were assembled on the PEI using layer-by-layer (LBL) assembly technology. We used scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy and contact angle measurements to examine all Ti samples. The drug release test of rutin was also carried out to detect the slow-release performance. The osteogenic abilities of the samples were evaluated by experiments on an osteoporosis rat model and MC3T3-E1 cells. The results (SEM, FTIR and contact angle measurements) all confirmed that the PEI substrate layer and HA/CS-RT multilayer film were effectively immobilised on titanium. The drug release test revealed that a rutin controlled release mechanism had been successfully established. Furthermore, thein vitrodata revealed that osteoblasts on the coated titanium matrix had greater adhesion, proliferation, and differentiation capacity than the osteoblasts on the pure titanium surface. When MC3T3-E1 cells were exposed to H2O2-induced oxidative stressin vitro, cell-based tests revealed great tolerance and increased osteogenic potential on HA/CS-RT substrates. We also found that the HA/CS-RT coating significantly increased the new bone mass around the implant. The LBL-deposited HA/CS-RT multilayer coating on the titanium base surface established an excellent rutin-controlled release system, which significantly improved osseointegration and promoted osteogenesis under oxidative stress conditions, suggesting a new implant therapy strategy for patients with osteoporosis.


Assuntos
Materiais Revestidos Biocompatíveis , Ácido Hialurônico , Osseointegração , Osteoblastos , Osteogênese , Osteoporose , Próteses e Implantes , Rutina , Propriedades de Superfície , Titânio , Animais , Titânio/química , Rutina/química , Rutina/farmacologia , Osteogênese/efeitos dos fármacos , Ratos , Osteoporose/tratamento farmacológico , Camundongos , Osteoblastos/efeitos dos fármacos , Osteoblastos/citologia , Osteoblastos/metabolismo , Osseointegração/efeitos dos fármacos , Ácido Hialurônico/química , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Oxirredução , Quitosana/química , Feminino , Ratos Sprague-Dawley , Adesão Celular/efeitos dos fármacos , Espectroscopia de Infravermelho com Transformada de Fourier , Diferenciação Celular/efeitos dos fármacos , Microscopia Eletrônica de Varredura , Proliferação de Células/efeitos dos fármacos , Polietilenoimina/química , Células 3T3 , Estresse Oxidativo/efeitos dos fármacos , Nanopartículas em Multicamadas
2.
J Environ Manage ; 359: 120987, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38692029

RESUMO

The removal of organic pollutants in water environments and the resource utilization of solid waste are two pressing issues around the world. Facing the increasing pollution induced by discharge of mining effluents containing sodium isopropyl xanthate (SIPX), in this work, municipal solid waste incineration fly ash (MSWI FA) was pretreated by hydrothermal method to produce stabilized FA, which was then innovatively used as support for the construction of FA/TiO2/BiOCl nanocomposite (FTB) with promoted photocatalytic activity under visible light and natural sunlight. When the content of FA was 20 wt% and the mass ratio of TiO2 to BiOCl was 4:6, a remarkable performance for the optimal FTB (20-FTB-2) was achieved. Characterizations demonstrated that TiO2 and BiOCl uniformly dispersed on FA contributing to high surface area and broad light adsorption of FTB, which exhibits excellent adsorption capacity and light response ability. Build in electric field formed in the interface of TiO2/BiOCl heterojunction revealed by density functional theory calculations accelerated the separation of photoinduced e- and h+, leading to high efficiency for SIPX degradation. The synergetic effect combined with adsorption and photocatalytic degradation endowed 20-FTB-2 superior SIPX removal efficiency over 99% within 30 min under visible light and natural sunlight irradiation. The photocatalytic degradation pathways of SIPX were determined through theoretical calculations and characterizations, and the toxic byproduct CS2 was effectively eliminated through oxidation of •O2-. For 20-FTB-2, reusability of photocatalyst was showed by cycle tests, also the concentrations of main heavy metals (Pb, Zn, Cu, Cr, and Cd) in the liquid phases released during photocatalyst preparation process (< 1 mg/L) and photodegradation process (< 8.5 µg/L) proved the satisfactory stability with low toxicity. This work proposed a novel strategy to develop efficient and stable support-based photocatalysts by utilizing MSWI FA and realize its resource utilization.


Assuntos
Cinza de Carvão , Nanocompostos , Titânio , Nanocompostos/química , Titânio/química , Cinza de Carvão/química , Catálise , Adsorção , Resíduos Sólidos , Poluentes Químicos da Água/química
3.
Food Chem ; 451: 139515, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38703734

RESUMO

Imidacloprid (IMI) are widely used in modern tea industry for pest control, but IMI residues pose a great threat to human health. Herein, we propose a regeneration metal-semiconductor SERS substrate for IMI detection. We fabricated the SERS sensor through the in-situ growth of a nano-heterostructure incorporating a semiconductor (TiO2) and plasmonic metals (Au, Ag) on oxidized carbon cloth (OCC). Leveraging the high-density hot spots, the formed Ag/AuNPs-TiO2-OCC substrate exhibits higher enhancement factors (1.92 × 108) and uniformity (RSD = 7.68%). As for the detection of IMI on the substrate, the limit of detection was lowered to 4.1 × 10-6 µg/mL. With a hydrophobic structure, the Ag/AuNPs-TiO2-OCC possessed excellent self-cleaning performance addressing the limitation of single-use associated with traditional SERS substrates, as well as the degradation capability of the substrate under ultraviolet (UV) light. Accordingly, Ag/AuNPs-TiO2-OCC showcases outstanding SERS sensing and regenerating properties, making it poised for extensive application in the field of food safety assurance.


Assuntos
Carbono , Ouro , Nanopartículas Metálicas , Neonicotinoides , Nitrocompostos , Prata , Análise Espectral Raman , Titânio , Titânio/química , Ouro/química , Nanopartículas Metálicas/química , Prata/química , Análise Espectral Raman/métodos , Carbono/química , Neonicotinoides/química , Neonicotinoides/análise , Nitrocompostos/química , Contaminação de Alimentos/análise , Oxirredução , Inseticidas/química , Inseticidas/análise , Limite de Detecção , Têxteis/análise
4.
J Orthop Surg Res ; 19(1): 304, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38769535

RESUMO

BACKGROUND: Periprosthetic joint infection is a serious complication following joint replacement. The development of bacterial biofilms bestows antibiotic resistance and restricts treatment via implant retention surgery. Electromagnetic induction heating is a novel technique for antibacterial treatment of metallic surfaces that has demonstrated in-vitro efficacy. Previous studies have always employed stationary, non-portable devices. This study aims to assess the in-vitro efficacy of induction-heating disinfection of metallic surfaces using a new Portable Disinfection System based on Induction Heating. METHODS: Mature biofilms of three bacterial species: S. epidermidis ATCC 35,984, S. aureus ATCC 25,923, E. coli ATCC 25,922, were grown on 18 × 2 mm cylindrical coupons of Titanium-Aluminium-Vanadium (Ti6Al4V) or Cobalt-chromium-molybdenum (CoCrMo) alloys. Study intervention was induction-heating of the coupon surface up to 70ºC for 210s, performed using the Portable Disinfection System (PDSIH). Temperature was monitored using thermographic imaging. For each bacterial strain and each metallic alloy, experiments and controls were conducted in triplicate. Bacterial load was quantified through scraping and drop plate techniques. Data were evaluated using non-parametric Mann-Whitney U test for 2 group comparison. Statistical significance was fixed at p ≤ 0.05. RESULTS: All bacterial strains showed a statistically significant reduction of CFU per surface area in both materials. Bacterial load reduction amounted to 0.507 and 0.602 Log10 CFU/mL for S. aureus on Ti6Al4V and CoCrMo respectively, 5.937 and 3.500 Log10 CFU/mL for E. coli, and 1.222 and 0.372 Log10 CFU/mL for S. epidermidis. CONCLUSIONS: Electromagnetic induction heating using PDSIH is efficacious to reduce mature biofilms of S aureus, E coli and S epidermidis growing on metallic surfaces of Ti6Al4V and CoCrMo alloys.


Assuntos
Ligas , Biofilmes , Desinfecção , Escherichia coli , Infecções Relacionadas à Prótese , Staphylococcus aureus , Titânio , Biofilmes/efeitos dos fármacos , Desinfecção/métodos , Escherichia coli/crescimento & desenvolvimento , Staphylococcus aureus/efeitos dos fármacos , Infecções Relacionadas à Prótese/prevenção & controle , Infecções Relacionadas à Prótese/microbiologia , Staphylococcus epidermidis/efeitos dos fármacos , Prótese Articular/microbiologia , Artroplastia de Substituição/instrumentação , Artroplastia de Substituição/métodos , Calefação/instrumentação , Calefação/métodos , Humanos , Fenômenos Eletromagnéticos , Vitálio
5.
Clin Exp Dent Res ; 10(3): e893, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38770579

RESUMO

OBJECTIVES: The present study reviews the current literature regarding the utilization of the extended finite element method (XFEM) in clinical and experimental endodontic studies and the suitability of XFEM in the assessment of cyclic fatigue in rotary endodontic nickel-titanium (NiTi) instruments. MATERIAL AND METHODS: An electronic literature search was conducted using the appropriate search terms, and the titles and abstracts were screened for relevance. The search yielded 13 hits after duplicates were removed, and four studies met the inclusion criteria for review. RESULTS: No studies to date have utilized XFEM to study cyclic fatigue or crack propagation in rotary endodontic NiTi instruments. Challenges such as modelling material inputs and fatigue criteria could explain the lack of utilization of XFEM in the analysis of mechanical behavior in NiTi instruments. CONCLUSIONS: The review showed that XFEM was seldom employed in endodontic literature. Recent work suggests potential promise in using XFEM for modelling NiTi structures.


Assuntos
Endodontia , Análise de Elementos Finitos , Níquel , Titânio , Humanos , Ligas Dentárias/química , Instrumentos Odontológicos , Endodontia/instrumentação , Endodontia/métodos , Teste de Materiais , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Estresse Mecânico
6.
J Orthop Surg Res ; 19(1): 299, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38755635

RESUMO

BACKGROUND: This study aims to evaluate the optimal ratio of synthetic bone graft (SBG) material and platelet rich fibrin (PRF) mixed in a metal 3D-printed implant to enhance bone regeneration. METHODS: Specialized titanium hollow implants (5 mm in diameter and 6 mm in height for rabbit; 6 mm in diameter and 5 mm in height for pig) were designed and manufactured using 3D printing technology. The implants were divided into three groups and filled with different bone graft combinations, namely (1) SBG alone; (2) PRF to SBG in 1:1 ratio; (3) PRF to SBG in 2:1 ratio. These three groups were replicated tightly into each bone defect in distal femurs of rabbits (nine implants, n = 3) and femoral shafts of pigs (fifteen implants, n = 5). Animal tissue sections were obtained after euthanasia at the 8th postoperative week. The rabbit specimens were stained with analine blue, while the pig specimens were stained with Masson-Goldner's trichrome stain to perform histologically examination. All titanium hollow implants were well anchored, except in fracture specimens (three in the rabbit and one fracture in the pig). RESULT: Rabbit specimens under analine blue staining showed that collagen tissue increased by about 20% and 40% in the 1:1 ratio group and the 2:1 ratio group, respectively. Masson-Goldner's trichrome stain results showed that new bone growth increased by 32% in the 1:1 ratio PRF to SBG, while - 8% in the 2:1 ratio group. CONCLUSION: This study demonstrated that placing a 1:1 ratio combination of PRF and SBG in a stabilized titanium 3D printed implant resulted in an optimal increase in bone growth.


Assuntos
Regeneração Óssea , Fibrina Rica em Plaquetas , Impressão Tridimensional , Titânio , Animais , Coelhos , Regeneração Óssea/efeitos dos fármacos , Regeneração Óssea/fisiologia , Suínos , Fêmur/cirurgia , Substitutos Ósseos , Transplante Ósseo/métodos , Próteses e Implantes
7.
PeerJ ; 12: e17418, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38799069

RESUMO

Aim: Assess the effect of simulated clinical use and sterilization on the cyclic fatigue resistance of Race Evo and Tia Tornado Blue nickel titanium (NiTi) files. Materials and Methods: For this study, a total of sixty-four NiTi files were selected, with thirty-two files each from two different manufacturers. Files from each manufacturer were subdivided into four subgroups (n = 8) based on the test parameters. The control groups included files that were neither used nor sterilized. Files from the test groups were used to prepare the root canals of extracted mandibular premolars and then sterilized. This procedure was repeated once, twice, or thrice, depending on the test group. All files were then subjected to a cyclic fatigue test. Data was statistically analyzed using the Kruskal-Wallis and Mann-Whitney U tests. Results: No significant difference was observed in the number of cycles to failure (NCF) among the subgroups for both types of files (P = 0.869 for Tia Tornado Blue, P = 0.626 for Race Evo). Tia Tornado Blue files displayed significantly higher NCF values in the control (P = 0.021), once (P = 0.027), and thrice (P = 0.031) usage groups when compared to Race Evo files. Conclusions: Repeated clinical use and sterilization for up to three cycles did not affect the cyclic fatigue resistance of Race Evo and Tia Tornado Blue files.


Assuntos
Níquel , Esterilização , Titânio , Esterilização/métodos , Humanos , Falha de Equipamento , Teste de Materiais , Preparo de Canal Radicular/instrumentação
8.
Int J Nanomedicine ; 19: 4495-4513, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38799696

RESUMO

Background: Electrical stimulation (ES) can effectively promote skin wound healing; however, single-electrode-based ES strategies are difficult to cover the entire wound area, and the effectiveness of ES is often limited by the inconsistent mechanical properties of the electrode and wound tissue. The above factors may lead to ES treatment is not ideal. Methods: A multifunctional conductive hydrogel dressing containing methacrylated gelatin (GelMA), Ti3C2 and collagen binding antimicrobial peptides (V-Os) was developed to improve wound management. Ti3C2 was selected as the electrode component due to its excellent electrical conductivity, the modified antimicrobial peptide V-Os could replace traditional antibiotics to suppress bacterial infections, and GelMA hydrogel was used due to its clinical applicability in wound healing. Results: The results showed that this new hydrogel dressing (GelMA@Ti3C2/V-Os) not only has excellent electrical conductivity and biocompatibility but also has a durable and efficient bactericidal effect. The modified antimicrobial peptides V-Os used were able to bind more closely to GelMA hydrogel to exert long-lasting antibacterial effects. The results of cell experiment showed that the GelMA@Ti3C2/V-Os hydrogel dressing could enhance the effect of current stimulation and significantly improve the migration, proliferation and tissue repair related genes expression of fibroblasts. In vitro experiments results showed that under ES, GelMA@Ti3C2/V-Os hydrogel dressing could promote re-epithelialization, enhance angiogenesis, mediate immune response and prevent wound infection. Conclusion: This multifunctional nanocomposite hydrogel could provide new strategies for promoting infectious wound healing.


Assuntos
Antibacterianos , Condutividade Elétrica , Hidrogéis , Nanocompostos , Cicatrização , Cicatrização/efeitos dos fármacos , Antibacterianos/farmacologia , Antibacterianos/química , Nanocompostos/química , Animais , Hidrogéis/química , Hidrogéis/farmacologia , Camundongos , Estimulação Elétrica , Gelatina/química , Humanos , Peptídeos Catiônicos Antimicrobianos/química , Peptídeos Catiônicos Antimicrobianos/farmacologia , Fibroblastos/efeitos dos fármacos , Titânio/química , Titânio/farmacologia , Masculino , Proliferação de Células/efeitos dos fármacos , Terapia por Estimulação Elétrica/métodos
9.
J Environ Sci (China) ; 144: 212-224, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38802232

RESUMO

In this work, the perovskite LaZnO3 was synthesized via sol-gel method and applied for photocatalytic treatment of sulfamethizole (SMZ) antibiotics under visible light activation. SMZ was almost completely degraded (99.2% ± 0.3%) within 4 hr by photocatalyst LaZnO3 at the optimal dosage of 1.1 g/L, with a mineralization proportion of 58.7% ± 0.4%. The efficient performance of LaZnO3 can be attributed to its wide-range light absorption and the appropriate energy band edge levels, which facilitate the formation of active agents such as ·O2-, h+, and ·OH. The integration of RP-HPLC/Q-TOF-MS and DFT-based computational techniques revealed three degradation pathways of SMZ, which were initiated by the deamination reaction at the aniline ring, the breakdown of the sulfonamide moieties, and a process known as Smile-type rearrangement and SO2 intrusion. Corresponding toxicity of SMZ and the intermediates were analyzed by quantitative structure activity relationship (QSAR), indicating the effectiveness of LaZnO3-based photocatalysis in preventing secondary pollution of the intermediates to the ecosystem during the degradation process. The visible-light-activated photocatalyst LaZnO3 exhibited efficient performance in the occurrence of inorganic anions and maintained high durability across multiple recycling tests, making it a promising candidate for practical antibiotic treatment.


Assuntos
Antibacterianos , Luz , Óxidos , Sulfametizol , Titânio , Poluentes Químicos da Água , Antibacterianos/química , Titânio/química , Óxidos/química , Sulfametizol/química , Poluentes Químicos da Água/química , Compostos de Cálcio/química , Catálise , Fotólise , Modelos Químicos
10.
Int J Oral Implantol (Berl) ; 17(2): 203-220, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38801333

RESUMO

PURPOSE: Complex bone defects with a horizontal and vertical combined deficiency pose a clinical challenge in implant dentistry. This study reports the case of a young female patient who presented with a perforating bone defect in the aesthetic zone. MATERIALS AND METHODS: Based on prosthetically guided bone regeneration, virtual 3D bone augmentation was planned. A 3D printed customised titanium mesh and the autogenous bone ring technique were then utilised simultaneously to achieve a customised bone contour. After 6 months, the titanium mesh was removed and connective tissue grafting was performed. Finally, implants were placed and the provisional and definitive prostheses were delivered following a digital approach. Vertical and horizontal bone gain, new bone density, pseudo-periosteum type and marginal bone loss were measured. Planned bone volume, regenerated bone volume and regeneration rate were analysed. RESULTS: Staged tooth shortening led to a coronal increase in keratinised mucosa. The customised titanium mesh and bone ring technique yielded 14.27 mm vertical bone gain and 12.9 mm horizontal bone gain in the perforating area. When the titanium mesh was removed, the reopening surgery showed a Type 1 pseudo-periosteum (none or < 1 mm), and CBCT scans revealed a new bone density of ~550 HU. With a planned bone volume of 1063.55 mm3, the regenerated bone volume was 969.29 mm3, indicating a regeneration rate of 91.14%. The 1-year follow-up after definitive restoration revealed no complications except for 0.55 to 0.60 mm marginal bone loss. CONCLUSION: Combined application of customised titanium mesh and an autogenous bone ring block shows promising potential to achieve prosthetically guided bone regeneration for complex bone defects in the aesthetic zone.


Assuntos
Aumento do Rebordo Alveolar , Impressão Tridimensional , Telas Cirúrgicas , Titânio , Humanos , Feminino , Aumento do Rebordo Alveolar/métodos , Adulto , Transplante Ósseo/métodos , Regeneração Óssea , Estética Dentária , Implantação Dentária Endóssea/métodos
11.
Int J Oral Implantol (Berl) ; 17(2): 175-185, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38801331

RESUMO

PURPOSE: The reverse guided bone regeneration protocol is a digital workflow that has been introduced to reduce the complexity of guided bone regeneration and promote prosthetically guided bone reconstruction with a view to achieving optimal implant placement and prosthetic finalisation. The aim of the present study was to investigate the accuracy of this digital protocol. MATERIALS AND METHODS: Sixteen patients with partial edentulism in the maxilla or mandible and with vertical or horizontal bone defects were treated using the reverse guided bone regeneration protocol to achieve fixed implant rehabilitations. For each patient, a digital wax-up of the future rehabilitation was created and implant planning was carried out, then the necessary bone reconstruction was simulated virtually and the CAD/CAM titanium mesh was designed and used to perform guided bone regeneration. The computed tomography datasets from before and after guided bone regeneration were converted into 3D models and aligned digitally. The actual position of the mesh was compared to the virtual position to assess the accuracy of the digital project. Surgical and healing complications were also recorded. A descriptive analysis was conducted and a one-sample t test and Wilcoxon test were utilised to assess the statistical significance of the accuracy. The level of significance was set at 0.05. RESULTS: A total of 16 patients with 16 treated sites were enrolled. Comparing the virtually planned mesh position with the actual position, an overall mean discrepancy between the two of 0.487 ± 0.218 mm was achieved. No statistically significant difference was observed when comparing this to a predefined minimum tolerance (P = 0.06). No surgical complications occurred, but two healing complications were recorded (12.5%). CONCLUSION: Within the limitations of the present study, the reverse guided bone regeneration digital protocol seems to be able to achieve good accuracy in reproducing the content of the virtual plan. Nevertheless, further clinical comparative studies are required to confirm these results.


Assuntos
Regeneração Óssea , Desenho Assistido por Computador , Telas Cirúrgicas , Titânio , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Tomografia Computadorizada por Raios X/métodos , Arcada Parcialmente Edêntula/cirurgia , Arcada Parcialmente Edêntula/reabilitação , Implantação Dentária Endóssea/métodos , Resultado do Tratamento , Imageamento Tridimensional/métodos , Regeneração Tecidual Guiada Periodontal/métodos
12.
J Biomed Mater Res B Appl Biomater ; 112(6): e35415, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38773744

RESUMO

This study reports the synthesis and characterization of hydroxyapatite (HA)-based bio-composites reinforced with varying amounts (by weight, 1-15 wt.%) of bio-medium entropy alloy (BioMEA) for load-bearing implant applications. BioMEA powders consisting of Ti, Nb, Zr, and Mo were mechanically alloyed for 100 h and subsequently added to HA using powder metallurgy techniques. To show the effect of BioMEA, the microstructure, density, and mechanical tests have been conducted and the synthesized BioMEA was characterized by scanning electron microscope (SEM), x-ray diffractometer (XRD), and Fourier-transform infrared spectroscopy (FTIR) analysis. In addition, in vitro degradation behavior and bioactivity analyses of bio-composites have been conducted. XRD analysis revealed the formation of BioMEA after 20 h of mechanical alloying. The highest density value of 2.47 g/cm3 was found in 15 wt.% BioMEA-reinforced bio-composite. The addition of BioMEA reinforcement led to a significant increase in hardness and tensile strength values, with the highest values observed at 15 wt.% reinforcement. Compression tests demonstrated a significant increase in compressive strength and deformation capability of the bio-composites with the highest values observed at 15 wt.% BioMEA addition. The highest toughness of 7.68 kJ/m2 was measured in 10 wt.% MEA-reinforced bio-composites. The produced bio-composite materials have an elastic modulus between 3.5-5.5 GPa, which may provide a solution to the stress shielding problems caused by the high elastic modulus of metallic implant materials. The most severe degradation occurred in 15 wt.% MEA-reinforced bio-composites, and the effect of degradation caused a decrease in Ca and an increase in Ti-Ni-Zr-Mo in all bio-composites. These findings suggest that HA/BioMEA bio-composites have the potential to be developed as advanced biomaterials with moderate mechanical and biological properties for load-bearing implant applications.


Assuntos
Ligas , Durapatita , Teste de Materiais , Titânio , Zircônio , Zircônio/química , Durapatita/química , Ligas/química , Titânio/química , Entropia , Nióbio/química , Materiais Biocompatíveis/química
13.
BMC Surg ; 24(1): 169, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38811965

RESUMO

BACKGROUND: Whether polyetheretherketone (PEEK) rods have potential as an alternative to titanium alloy (Ti) rods in transforaminal lumbar interbody fusion (TLIF) remains unclear, especially in cases with insufficient anterior support due to the absence of a cage. The purpose of this study was to investigate biomechanical differences between PEEK rods and Ti rods in TLIF with and without a cage. METHODS: An intact L1-L5 lumbar finite element model was constructed and validated. Accordingly, four TLIF models were developed: (1) Ti rods with a cage; (2) PEEK rods with a cage; (3) Ti rods without a cage; and (4) PEEK rods without a cage. The biomechanical properties were then compared among the four TLIF constructs. RESULTS: With or without a cage, no obvious differences were found in the effect of PEEK rods and Ti rods on the range of motion, adjacent disc stress, and adjacent facet joint force. Compared to Ti rods, PEEK rods increase the average bone graft strain (270.8-6055.2 µE vs. 319.0-8751.6 µE). Moreover, PEEK rods reduced the stresses on the screw-rod system (23.1-96.0 MPa vs. 7.2-48.4 MPa) but increased the stresses on the cage (4.6-35.2 MPa vs. 5.6-40.9 MPa) and endplates (5.7-32.5 MPa vs. 6.6-37.6 MPa). CONCLUSIONS: Regardless of whether a cage was used for TLIF, PEEK rods theoretically have the potential to serve as an alternative to Ti rods because they may provide certain stability, increase the bone graft strain, and reduce the posterior instrumentation stress, which might promote bony fusion and decrease instrumentation failure.


Assuntos
Ligas , Benzofenonas , Análise de Elementos Finitos , Cetonas , Vértebras Lombares , Polietilenoglicóis , Polímeros , Fusão Vertebral , Titânio , Humanos , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Fenômenos Biomecânicos , Vértebras Lombares/cirurgia , Amplitude de Movimento Articular , Materiais Biocompatíveis
14.
Clin Oral Investig ; 28(6): 338, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38797781

RESUMO

OBJECTIVES: To clinically compare the effects of broader archwires to standard archwires, using conventional brackets in both cases, on the transverse and incisor changes in maxillary and mandibular arches during leveling and alignment. MATERIALS AND METHODS: Fifty-two patients presenting with crowding were allocated into two groups; one group received the broad Damon archwires while the other received standard 3M OrthoForm III Ovoid archwires. All participants were treated with conventional brackets using similar archwire sequences (0.014, 0.018, 0.016 × 0.022/0.016 × 0.025, 0.019 × 0.025 NiTi/CuNiTi archwires). Digital casts were obtained from alginate impressions before treatment (T0) and six weeks after inserting 0.019 × 0.025 NiTi archwires (T1). Pretreatment (T0) and post-alignment (T1) lateral cephalograms were obtained for each patient. The primary outcomes were the changes in the transverse arch dimensions and incisor inclination. The secondary outcomes were the horizontal and vertical linear changes in incisor position. RESULTS: Complete data were collected for 47 patients. There was a significant increase in arch width during treatment within each group, except for upper inter-molar width in 3M group (P = 0.071). Damon wire induced a statistically significant increase in maxillary inter-second premolar width (P = 0.042), and mandibular inter-first premolar (P = 0.043), inter-second premolar (P = 0.008) and inter-molar widths (P = 0.033) compared to 3M group. The increase in incisor proclination and the linear change in incisor position were significant within each group, with less mandibular incisor proclination (P = 0.004) and horizontal advancement (P = 0.038) in the Damon group. CONCLUSIONS: Damon archwires created a comparatively greater increase in the maxillary inter-second premolar width and the mandibular inter-first premolar, inter-second premolar, and inter-molar widths, and less proclination and horizontal advancement in mandibular incisors. The study provides invaluable evidence that using broad archwires with self-ligating brackets is the reason behind any greater expansion observed in this system rather than the unique mechanical and biological features exerted by the self-ligating system. CLINICAL RELEVANCE: Our results suggest that Damon archwire might be a better alternative compared to the narrower standard archwires that are usually used with conventional brackets, especially in the mandibular arch, in cases where mild to moderate crowding is planned to be resolved with a non-extraction approach. However, as arch expansion in the absence of posterior crossbites raises the question of long-term stability, the reported advantage of the use of wide wires should be interpreted with caution and should be considered in the retention phase, bearing in mind that achieving a good post-treatment occlusion is important for enhancing post-treatment stability.


Assuntos
Cefalometria , Incisivo , Má Oclusão , Desenho de Aparelho Ortodôntico , Braquetes Ortodônticos , Fios Ortodônticos , Humanos , Feminino , Masculino , Má Oclusão/terapia , Adolescente , Níquel/química , Arco Dental , Titânio/química , Resultado do Tratamento , Técnicas de Movimentação Dentária/instrumentação , Técnicas de Movimentação Dentária/métodos , Cobre
15.
Sci Rep ; 14(1): 12243, 2024 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-38806607

RESUMO

Stress shielding and aseptic loosening are complications of short stem total hip arthroplasty, which may lead to hardware failure. Stems with increased porosity toward the distal end were discovered to be effective in reducing stress shielding, however, there is a lack of research on optimized porous distribution in stem's coating. This study aimed to optimize the distribution of the coefficient of friction of a metaphyseal femoral stem, aiming for reducing stress shielding in the proximal area. A finite element analysis model of an implanted, titanium alloy short-tapered wedge stem featuring a porous coating made of titanium was designed to simulate a static structural analysis of the femoral stem's behavior under axial loading in Analysis System Mechanical Software. For computational feasibility, 500 combinations of coefficients of friction were randomly sampled. Increased strains in proximal femur were found in 8.4% of the models, which had decreased coefficients of friction in middle medial areas of porous coating and increased in lateral proximal and lateral and medial distal areas. This study reported the importance of the interface between bone and middle medial and distal lateral areas of the porous coating in influencing the biomechanical behavior of the proximal femur, and potentially reducing stress shielding.


Assuntos
Artroplastia de Quadril , Fêmur , Análise de Elementos Finitos , Fricção , Prótese de Quadril , Titânio , Humanos , Fêmur/fisiologia , Porosidade , Artroplastia de Quadril/métodos , Titânio/química , Estresse Mecânico , Desenho de Prótese , Materiais Revestidos Biocompatíveis/química , Fenômenos Biomecânicos , Ligas/química
16.
PLoS One ; 19(5): e0302551, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38696475

RESUMO

Recently developed Nickel-Titanium (NiTi) instruments with practical changes have resulted in safer instrumentation. In addition, topographical features on the file surface are a contributing factor to clinical durability. Therefore, this study aimed to investigate both the cyclic fatigue resistance and the roughness change of MTwo and Rotate instruments (VDW, Munich, Germany). Each instrument (n = 6/each group) was scanned with an atomic force microscopy prior to and after instrumentation. In addition, cyclic fatigue testing was conducted for each instrument (n = 11/each group) with stainless-steel blocks, including 45°-60°-90° degrees of curvature milled to the instruments' size. The roughness parameters increased for both systems after instrumentation (p<0.05). Both systems presented an increased roughness following instrumentation (p<0.05). The cyclic fatigue resistance was lowest at 90° for both systems (p<0.05), whereas the Rotate files presented a higher resistance than that of the Mtwo files (p<0.05). Compared to the Mtwo files, Rotate files presented better resistance, while the resistance decreased as the curvature increased.


Assuntos
Níquel , Propriedades de Superfície , Titânio , Titânio/química , Níquel/química , Microscopia de Força Atômica , Teste de Materiais , Preparo de Canal Radicular/instrumentação
17.
Sci Adv ; 10(19): eadm9561, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38718119

RESUMO

Lactic acid (LA) accumulation in the tumor microenvironment poses notable challenges to effective tumor immunotherapy. Here, an intelligent tumor treatment microrobot based on the unique physiological structure and metabolic characteristics of Veillonella atypica (VA) is proposed by loading Staphylococcus aureus cell membrane-coating BaTiO3 nanocubes (SAM@BTO) on the surface of VA cells (VA-SAM@BTO) via click chemical reaction. Following oral administration, VA-SAM@BTO accurately targeted orthotopic colorectal cancer through inflammatory targeting of SAM and hypoxic targeting of VA. Under in vitro ultrasonic stimulation, BTO catalyzed two reduction reactions (O2 → •O2- and CO2 → CO) and three oxidation reactions (H2O → •OH, GSH → GSSG, and LA → PA) simultaneously, effectively inducing immunogenic death of tumor cells. BTO catalyzed the oxidative coupling of VA cells metabolized LA, effectively disrupting the immunosuppressive microenvironment, improving dendritic cell maturation and macrophage M1 polarization, and increasing effector T cell proportions while decreasing regulatory T cell numbers, which facilitates synergetic catalysis and immunotherapy.


Assuntos
Neoplasias Colorretais , Imunoterapia , Microambiente Tumoral , Neoplasias Colorretais/terapia , Neoplasias Colorretais/imunologia , Neoplasias Colorretais/patologia , Imunoterapia/métodos , Animais , Camundongos , Humanos , Catálise , Linhagem Celular Tumoral , Nanoestruturas/química , Materiais Biomiméticos/química , Administração Oral , Titânio/química , Biomimética/métodos , Ácido Láctico/química , Células Dendríticas/imunologia , Células Dendríticas/metabolismo , Compostos de Bário
18.
Mikrochim Acta ; 191(5): 294, 2024 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-38698253

RESUMO

Early transition metal carbides (MXene) hybridized by precious metals open a door for innovative electrochemical biosensing device design. Herein, we present a facile one-pot synthesis of gold nanoparticles (AuNPs)-doped two-dimensional (2D) titanium carbide MXene nanoflakes (Ti3C2Tx/Au). Ti3C2Tx MXene exhibits high electrical conductivity and yields synergistic signal amplification in conjunction with AuNPs leading to excellent electrochemical performance. Thus Ti3C2Tx/Au hybrid nanostructure can be used as an electrode platform for the electrochemical analysis of various targets. We used screen-printed electrodes modified with the Ti3C2Tx/Au electrode and functionalized with different biorecognition elements to detect and quantify an antibiotic, ampicillin (AMP), and a mycotoxin, fumonisin B1 (FB1). The ultralow limits of detection of 2.284 pM and 1.617 pg.mL-1, which we achieved respectively for AMP and FB1 are far lower than their corresponding maximum residue limits of 2.8 nM in milk and 2 to 4 mg kg-1 in corn products for human consumption set by the United States Food and Drug Administration. Additionally, the linear range of detection and quantification of AMP and FB1 were, respectively, 10 pM to 500 nM and 10 pg mL-1 to 1 µg mL-1. The unique structure and excellent electrochemical performance of Ti3C2Tx/Au nanocomposite suggest that it is highly suitable for anchoring biorecognition entities such as antibodies and oligonucleotides for monitoring various deleterious contaminants in agri-food products.


Assuntos
Ampicilina , Técnicas Eletroquímicas , Fumonisinas , Ouro , Limite de Detecção , Nanopartículas Metálicas , Titânio , Fumonisinas/análise , Ouro/química , Ampicilina/análise , Ampicilina/química , Nanopartículas Metálicas/química , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Titânio/química , Técnicas Biossensoriais/métodos , Leite/química , Antibacterianos/análise , Eletrodos , Contaminação de Alimentos/análise , Animais
19.
J Biomed Mater Res B Appl Biomater ; 112(5): e35417, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38742468

RESUMO

Stress shielding is one of the major concerns for total ankle replacement implants nowadays, because it is responsible for implant-induced bone resorption. The bone resorption contributes to the aseptic loosening and failure of ankle implants in later stages. To reduce the stress shielding, improvements can be made in the implant material by decreasing the elastic mismatch between the implant and the tibia bone. This study proposes a new functionally graded material (FGM) based tibial implant for minimizing the problem of stress shielding. Three-dimensional finite element (FE) models of the intact tibia and the implanted tibiae were created to study the influence of material gradation law and volume fraction index on stress shielding and implant-bone micromotion. Different implant materials were considered that is, cobalt-chromium, titanium (Ti), and FGM with Ti at the bottom and hydroxyapatite (HA) at the top. The FE models of FGM implants were generated by using different volume fractions and the rule of mixtures. The rule of mixtures was used to calculate the FGM properties based on the local volume fraction. The volume fraction was defined by using exponential, power, and sigmoid laws. For the power and sigmoid law varying volume fraction indices (0.1, 0.2, 0.5, 1, 2, and 5) were considered. The geometry resembling STAR® ankle system tibial implant was considered for the present study. The results indicate that FGMs lower stress shielding but also marginally increase implant-bone micromotion; however, the values were within the acceptable limit for bone ingrowth. It is observed that the material gradation law and volume fraction index influence the performance of FGM tibial implants. The tibial implant composed of FGM using power law with a volume fraction index of 0.1 was the preferred option because it showed the least stress shielding.


Assuntos
Artroplastia de Substituição do Tornozelo , Análise de Elementos Finitos , Tíbia , Titânio , Titânio/química , Humanos , Durapatita/química , Desenho de Prótese , Estresse Mecânico , Teste de Materiais
20.
Mikrochim Acta ; 191(6): 316, 2024 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-38724679

RESUMO

An ultra-sensitive photoelectrochemical (PEC) sensor based on perovskite composite was developed for the determination of alkaline phosphatase (ALP) in human serum. In contrast to CsPbBr3 or Y6 that generated anodic current, the heterojunction of CsPbBr3/Y6 promoted photocarriers to separate and generated cathodic photocurrent. Ascorbic acid (AA) was produced by ALP hydrolyzing L-ascorbic acid 2-phosphate trisodium salt (AAP), which can combine with the holes on the photoelectrode surface, accelerating the transmission of photogenerated carriers, leading to enhanced photocurrent intensity. Thus, the enhancement of PEC current was linked to ALP activity. The PEC sensor exhibits good sensitivity for detection of ALP owing to the unique photoelectric properties of the CsPbBr3/Y6 heterojunction. The detection limit of the sensor was 0.012 U·L-1 with a linear dynamic range of 0.02-2000 U·L-1. Therefore, this PEC sensing platform shows great potential for the development of different PEC sensors.


Assuntos
Fosfatase Alcalina , Ácido Ascórbico , Técnicas Eletroquímicas , Eletrodos , Limite de Detecção , Óxidos , Processos Fotoquímicos , Titânio , Fosfatase Alcalina/química , Fosfatase Alcalina/sangue , Fosfatase Alcalina/metabolismo , Humanos , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Ácido Ascórbico/química , Ácido Ascórbico/sangue , Ácido Ascórbico/análogos & derivados , Titânio/química , Óxidos/química , Compostos de Cálcio/química , Técnicas Biossensoriais/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA