Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.910
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Pediatr Neurol ; 155: 171-176, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38669799

RESUMO

BACKGROUND: One of the most common causes of carpal tunnel syndrome (CTS) in childhood is mucopolysaccharidosis (MPS). While ultrasonography (US) can aid in the diagnosis of CTS in adult patients, there is limited experience of this in the pediatric group. We aimed to investigate the results of wrist ultrasonography, which may be a candidate alternative to electrophysiological examination. METHODS: The participants were evaluated for symptoms, physical examination findings, electrophysiological tests and grayscale US. CTS was diagnosed in accordance with the American Academy of Orthopedic Surgeons Management of Carpal Tunnel Syndrome: Evidence-Based Clinical Practice Guideline. RESULTS: Included in the study were 27 MPS patients aged 4.5-32 years and 30 healthy control subjects aged 4.3-26 years. Of the 54 wrists in the MPS group, 30 were diagnosed with CTS. The median cross-sectional area (CSA) at the proximal carpal tunnel, the CSA at the forearm, and the wrist-forearm ratio (WFR) were higher in the wrists of the MPS with CTS group than in those without CTS and the healthy control subjects. The WFR cutoff of ≥1.35, 56.6% (95% CI: 437.4-74.5) sensitivity, and 89.8% (95% CI: 81.0-95.5) specificity were consistent with a diagnosis of CTS (receiver operating characteristics analysis, area under the curve = 0.775, 95% CI: 0.673-0.877). CONCLUSION: Although the US provides results with unsatisfactory specificity and sensitivity, it is a candidate for further investigation for the diagnosis of CTS because it is an innovative, noninvasive, and more accessible method. WFR value may produce more meaningful results than wrist or forearm nerve area measurements.


Assuntos
Síndrome do Túnel Carpal , Mucopolissacaridoses , Ultrassonografia , Humanos , Síndrome do Túnel Carpal/diagnóstico por imagem , Masculino , Ultrassonografia/normas , Mucopolissacaridoses/complicações , Mucopolissacaridoses/diagnóstico por imagem , Feminino , Criança , Adolescente , Adulto Jovem , Adulto , Pré-Escolar , Punho/diagnóstico por imagem , Sensibilidade e Especificidade , Condução Nervosa/fisiologia
2.
Curr Opin Anaesthesiol ; 37(3): 259-265, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38573182

RESUMO

PURPOSE OF REVIEW: To discuss considerations surrounding the use of point-of-care ultrasound (POCUS) in pediatric anesthesiology. RECENT FINDINGS: POCUS is an indispensable tool in various medical specialties, including pediatric anesthesiology. Credentialing for POCUS should be considered to ensure that practitioners are able to acquire images, interpret them correctly, and use ultrasound to guide procedures safely and effectively. In the absence of formal guidelines for anesthesiology, current practice and oversight varies by institution. In this review, we will explore the significance of POCUS in pediatric anesthesiology, discuss credentialing, and compare the specific requirements and challenges currently associated with using POCUS in pediatric anesthesia. SUMMARY: Point-of-care ultrasound is being utilized by the pediatric anesthesiologist and has the potential to improve patient assessment, procedure guidance, and decision-making. Guidelines increase standardization and quality assurance procedures help maintain high-quality data. Credentialing standards for POCUS in pediatric anesthesiology are essential to ensure that practitioners have the necessary skills and knowledge to use this technology effectively and safely. Currently, there are no national pediatric POCUS guidelines to base credentialing processes on for pediatric anesthesia practices. Further work directed at establishing pediatric-specific curriculum goals and competency standards are needed to train current and future pediatric anesthesia providers and increase overall acceptance of POCUS use.


Assuntos
Anestesiologia , Competência Clínica , Credenciamento , Pediatria , Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia , Humanos , Anestesiologia/educação , Anestesiologia/normas , Credenciamento/normas , Sistemas Automatizados de Assistência Junto ao Leito/normas , Criança , Pediatria/educação , Pediatria/normas , Pediatria/métodos , Ultrassonografia/normas , Ultrassonografia/métodos , Competência Clínica/normas , Ultrassonografia de Intervenção/normas , Ultrassonografia de Intervenção/métodos
3.
J Neurooncol ; 167(3): 387-396, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38413458

RESUMO

PURPOSE: In an era characterized by rapid progression in neurosurgical technologies, traditional tools such as the non-navigated two-dimensional intraoperative ultrasound (nn-2D-IOUS) risk being overshadowed. Against this backdrop, this study endeavors to provide a comprehensive assessment of the clinical efficacy and surgical relevance of nn-2D-IOUS, specifically in the context of glioma resections. METHODS: This retrospective study undertaken at a single center evaluated 99 consecutive, non-selected patients diagnosed with both high-grade and low-grade gliomas. The primary objective was to assess the proficiency of nn-2D-IOUS in generating satisfactory image quality, identifying residual tumor tissue, and its influence on the extent of resection. To validate these results, early postoperative MRI data served as the reference standard. RESULTS: The nn-2D-IOUS exhibited a high level of effectiveness, successfully generating good quality images in 79% of the patients evaluated. With a sensitivity rate of 68% and a perfect specificity of 100%, nn-2D-IOUS unequivocally demonstrated its utility in intraoperative residual tumor detection. Notably, when total tumor removal was the surgical objective, a resection exceeding 95% of the initial tumor volume was achieved in 86% of patients. Additionally, patients in whom residual tumor was not detected by nn-2D-IOUS, the mean volume of undetected tumor tissue was remarkably minimal, averaging at 0.29 cm3. CONCLUSION: Our study supports nn-2D-IOUS's invaluable role in glioma surgery. The results highlight the utility of traditional technologies for enhanced surgical outcomes, even when compared to advanced alternatives. This is particularly relevant for resource-constrained settings and emphasizes optimizing existing tools for efficient patient care. NCT05873946 - 24/05/2023 - Retrospectively registered.


Assuntos
Neoplasias Encefálicas , Glioma , Padrão de Cuidado , Humanos , Glioma/cirurgia , Glioma/diagnóstico por imagem , Glioma/patologia , Estudos Retrospectivos , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Idoso , Procedimentos Neurocirúrgicos/métodos , Procedimentos Neurocirúrgicos/normas , Monitorização Intraoperatória/métodos , Monitorização Intraoperatória/normas , Ultrassonografia/métodos , Ultrassonografia/normas , Adulto Jovem , Neoplasia Residual/diagnóstico por imagem , Neoplasia Residual/cirurgia , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas
4.
Anesth Analg ; 138(6): 1174-1186, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38289868

RESUMO

BACKGROUND: A noninvasive and accurate method of determining fluid responsiveness in ventilated patients would help to mitigate unnecessary fluid administration. Although carotid ultrasound has been previously studied for this purpose, several studies have recently been published. We performed an updated systematic review and meta-analysis to evaluate the accuracy of carotid ultrasound as a tool to predict fluid responsiveness in ventilated patients. METHODS: Studies eligible for review investigated the accuracy of carotid ultrasound parameters in predicting fluid responsiveness in ventilated patients, using sensitivity and specificity as markers of diagnostic accuracy (International Prospective Register of Systematic Reviews [PROSPERO] CRD42022380284). All included studies had to use an independent method of determining cardiac output and exclude spontaneously ventilated patients. Six bibliographic databases and 2 trial registries were searched. Medline, Embase, Emcare, APA PsycInfo, CINAHL, and the Cochrane Library were searched on November 4, 2022. Clinicaltrials.gov and Australian New Zealand Clinical Trials Registry were searched on February 24, 2023. Results were pooled, meta-analysis was conducted where possible, and hierarchical summary receiver operating characteristic models were used to compare carotid ultrasound parameters. Bias and evidence quality were assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool and the Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) guidelines. RESULTS: Thirteen prospective clinical studies were included (n = 648 patients), representing 677 deliveries of volume expansion, with 378 episodes of fluid responsiveness (58.3%). A meta-analysis of change in carotid Doppler peak velocity (∆CDPV) yielded a sensitivity of 0.79 (95% confidence interval [CI], 0.74-0.84) and a specificity of 0.85 (95% CI, 0.76-0.90). Risk of bias relating to recruitment methodology, the independence of index testing to reference standards and exclusionary clinical criteria were evaluated. Overall quality of evidence was low. Study design heterogeneity, including a lack of clear parameter cutoffs, limited the generalizability of our results. CONCLUSIONS: In this meta-analysis, we found that existing literature supports the ability of carotid ultrasound to predict fluid responsiveness in mechanically ventilated adults. ∆CDPV may be an accurate carotid parameter in certain contexts. Further high-quality studies with more homogenous designs are needed to further validate this technology.


Assuntos
Artérias Carótidas , Hidratação , Valor Preditivo dos Testes , Respiração Artificial , Humanos , Artérias Carótidas/diagnóstico por imagem , Ultrassonografia/métodos , Ultrassonografia/normas , Reprodutibilidade dos Testes , Ultrassonografia das Artérias Carótidas
5.
Zhonghua Yi Xue Za Zhi ; 103(31): 2365-2388, 2023 Aug 22.
Artigo em Chinês | MEDLINE | ID: mdl-37599213

RESUMO

Liver transplantation is currently the only effective treatment for end-stage liver disease. Ultrasound examination has the advantages of non-invasive, convenient, and real-time display the intrahepatic vascular hemodynamic changes, and has become one of the preferred evaluation methods in the entire management process of liver transplantation. To further standardize the ultrasound examinations before and after liver transplantation, multiple-disciplinary experts in the field of liver transplantation, including specialists in ultrasound, liver surgery, and intervention medicine, were organized by the Chinese Medical Association Ultrasound Medicine Branch, the Chinese Medical Doctor Association Surgery Physician Branch, the Chinese Medical Doctor Association Interventional Physician Branch, and the Shanghai Medical Association Ultrasound Medicine Branch. Combined with the latest research practice in ultrasound diagnosis and treatment of liver transplantation, the ultrasound clinical practice guidelines for liver transplantation (2023 edition) was formulated. The contents of this guideline include ultrasound evaluation of liver transplantation donors and recipients, intraoperative and postoperative ultrasound examination of transplant livers, ultrasound applications in pediatric liver transplantation, and ultrasound-guided liver puncture biopsy and treatment, aiming to promote the standardized and high-quality development of liver transplantation ultrasound examination in China.


Assuntos
Transplante de Fígado , Fígado , Ultrassonografia , Humanos , Povo Asiático , China , Fígado/diagnóstico por imagem , Fígado/patologia , Fígado/cirurgia , Ultrassonografia/métodos , Ultrassonografia/normas , Doença Hepática Terminal/diagnóstico por imagem , Doença Hepática Terminal/cirurgia
6.
PeerJ ; 11: e15418, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37304881

RESUMO

Background: The use of sonography is a cost-effective and reliable method to evaluate upper extremity superficial tissue structural integrity and pathology. Establishing the measurement reliability of widely used diagnostic ultrasound evaluation for musculoskeletal assessment is paramount enhance accurate clinical evaluations. The objective of this study was to establish the inter-rater and intra-rater reliability of select ulnar collateral ligament (UCL) thickness measures at two distinct anatomical locations in intercollegiate baseball athletes using ultrasound imaging (USI). Methods: This was a prospective cohort study conducted in a university research laboratory and included a total of 17 NCAA Division I baseball athletes (age 20.4 ± 1.43, height = 183.63 cm ± 6.27 cm, mass = 89.28 kg ± 8.24 kg). Two trained clinicians measured UCL mid-substance and apex thickness in the throwing extremity, prospectively, on 5 occasions at 1-month intervals during rest. Intraclass correlation coefficients (ICCs) (model 3,3), associated standard error of measurement, and 95% minimal detectable change in thickness were derived. Results: Intrarater reliability estimates for operator 1 were 0.90-0.98 (mid-substance) and 0.91-0.99 (apex). Operator 2's values were 0.92-0.97 and 0.93-0.99, respectively. The standard error of measurement (SEM) ranged from 0.045-0.071 cm (mid-substance) and 0.023-0.067 cm (apex). The minimal detectable difference (MDD95) was 0.12-0.20 cm (mid-substance) and 0.07-0.19 cm (apex). Interrater reliability was 0.86-0.96 (mid-substance) and 0.79-0.98 (apex); most ICCs were >0.90. Measurement of UCL thickness at two locations demonstrated very good to excellent reliability with high precision. Using this protocol, two evaluators can obtain consistent UCL measurement at two positions. This finding has significant implications for the clinical evaluation of superficial tissue pathology of the same individual by two experienced practitioners.


Assuntos
Ligamento Colateral Ulnar , Ultrassonografia , Humanos , Adolescente , Adulto Jovem , Adulto , Ligamento Colateral Ulnar/diagnóstico por imagem , Ultrassonografia/normas , Reprodutibilidade dos Testes , Estudos Prospectivos , Estudos de Coortes
7.
Eur Radiol ; 33(9): 6482-6491, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37074423

RESUMO

OBJECTIVES: To develop a predictive model using conventional ultrasound combined with CEUS to identify thoracic wall recurrence after mastectomy. METHODS: A total of 162 women with pathologically confirmed thoracic wall lesions (benign 79, malignant 83; median size 1.9 cm, ranging 0.3-8.0 cm) underwent a mastectomy and were checked by both conventional ultrasound and CEUS and were retrospectively included. Logistic regression models of B-mode ultrasound (US) and color Doppler flow imaging (CDFI) with or without CEUS were established to assess the thoracic wall recurrence after mastectomy. The established models were validated by bootstrap resampling. The models were evaluated using calibration curve. The clinical benefit of models were assessed using decision curve analysis. RESULTS: The area under the receiver characteristic was 0.823 (95% CI: 0.76, 0.88) for model using US alone, 0.898 (95% CI: 0.84, 0.94) for model using US combined with CDFI, and 0.959 (95% CI: 0.92, 0.98) for model using US combined with both CDFI and CEUS. The diagnostic performance of the US combined with CDFI was significantly higher than that of the US alone (0.823 vs 0.898, p = 0.002) but significantly lower than that of the US combined with both CDFI and CEUS (0.959 vs 0.898, p < 0.001). Moreover, the unnecessary biopsy rate of the US combined with both CDFI and CEUS was significantly lower than that of the US combined with CDFI (p = 0.037). CONCLUSIONS: Compared to B-mode ultrasound and CDFI, CEUS improves the diagnostic performance to evaluate thoracic wall recurrence after mastectomy. KEY POINTS: • CUES is an effective supplementary method for US in the diagnosis of thoracic wall recurrence after mastectomy. • CEUS combined with both US and CDFI can significantly improve the accuracy of diagnosis of thoracic wall recurrence after mastectomy. • CEUS combined with both US and CDFI can reduce the rate of unnecessary biopsy of thoracic wall lesions after mastectomy.


Assuntos
Neoplasias da Mama , Meios de Contraste , Recidiva Local de Neoplasia , Parede Torácica , Ultrassonografia , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Diagnóstico Diferencial , Mastectomia , Estudos Retrospectivos , Sensibilidade e Especificidade , Parede Torácica/diagnóstico por imagem , Ultrassonografia/métodos , Ultrassonografia/normas , Recidiva Local de Neoplasia/diagnóstico por imagem , Adulto , Pessoa de Meia-Idade , Idoso , Modelos Logísticos
8.
J Clin Ultrasound ; 51(5): 876-878, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37025024

RESUMO

High-pressure injection injuries of the hand are uncommon accidents with potentially catastrophic complications. We present a case of a 49-years-old male with a high-pressure injection of motor oil in his left hand. Ultrasound accurately demonstrated soft tissue infiltration and late complications, playing a fundamental role in the treatment choice.


Assuntos
Traumatismos da Mão , Óleos Industriais , Ultrassonografia , Humanos , Masculino , Pessoa de Meia-Idade , Traumatismos da Mão/diagnóstico por imagem , Traumatismos da Mão/terapia , Pressão , Injeções , Ultrassonografia/normas , Imageamento por Ressonância Magnética , Raios X
9.
Med Ultrason ; 25(2): 139-144, 2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-36996386

RESUMO

AIM: To evaluate the effect of ultrasound (US) on learning curve and inter-subject performance variability of residents in radial artery cannulation. MATERIAL AND METHODS: Twenty non-anesthesiology residents who received standardized training in an anesthesiology department were selected and divided into two groups: anatomy group or US group. After training of relevant anatomy, US recognition and puncture skill, residents selected 10 patients either under US or anatomical localization performing radial artery catheterization. The number and time of successful cases of catheterization were recorded, success rate of first attempt and catheterization, as well as the total success rate of catheterization were calculated. The learning curve and inter-subject performance variability of residents were also calculated. Complications and the residents' satisfaction for teaching and self-confidence before puncture were also recorded. RESULTS: Compared to the anatomy group, total success rate and the success rate at first attempt were higher in US-guided group (88% vs. 57%, 94% vs. 81%). The average performance time in the US group was significantly less (2.9±0.8 min vs. 4.2±2.1 min) and the mean number of attempts was 1.6, while 2.6 for the anatomy group. With performing cases increasing, the average puncture time of residents in the US group decreased by 19s, while 14s in the anatomy group. More local hematoma occurred in the anatomy group. The satisfaction and confidence degree of residents were higher in US group ([98.5±6.5] vs [68.5±7.3], [90.2±8.6] vs [56.3±5.5]). CONCLUSION: US can significantly shorten the learning curve, reduce the inter-subject performance variability, improve the first attempt and total success rate of radial artery catheterization for non-anesthesiology residents.


Assuntos
Cateterismo Periférico , Internato e Residência , Curva de Aprendizado , Ultrassonografia , Humanos , Cateterismo Periférico/métodos , Cateterismo Periférico/normas , Artéria Radial/diagnóstico por imagem , Ultrassonografia/normas , Internato e Residência/métodos , Internato e Residência/normas , Desempenho Profissional
11.
Med Oral Patol Oral Cir Bucal ; 28(1): e56-e64, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36243993

RESUMO

BACKGROUND: Point-of-care-ultrasound can be applied to preview a difficult airway, detect the presence of fluid collection, and soft-tissue edema, and guide the drainage location, although is rarely used. The purpose of this study is to validate a protocol for the assessment of these clinical features on patients with severe odontogenic infections. MATERIAL AND METHODS: This was a single-group prospective cohort study (n=20) including patients with the diagnosis of deep-neck propagation of odontogenic infection. A transcervical linear high-frequency probe transducer (13-6 MHz) was used to scan the structures of the upper airway and the infectious collections. The drainage was guided by ultrasound and the patients were daily evaluated, according to the protocol. The data were extracted and the airway volume, midline deviation, and other important data such as length of hospital stay, dysphagia, voice alteration, raised floor of the mouth, dyspnea, and neck swelling were registered. RESULTS: The ultrasound examination was correlated with multiple clinical findings, such as dyslalia (p=0,069), dysphagia (p=0,028), dyspnea (p=0,001), among others. This protocol has an advantage as it can be used at bedside evaluation, allowing the assessment of severe and unstable patients, and predicting the increase of the hospitalization time (p=0,019). CONCLUSIONS: This protocol is reliable for the assessment of the upper airway, even in an emergency, predicting not only the severity of the clinical features but aids in the determination of the length of the hospitalization time.


Assuntos
Odontologia , Infecções , Testes Imediatos , Ultrassonografia , Humanos , Transtornos de Deglutição , Dispneia , Hospitalização , Pescoço/diagnóstico por imagem , Estudos Prospectivos , Controle de Infecções Dentárias , Testes Imediatos/normas , Ultrassonografia/normas , Boca/diagnóstico por imagem , Odontologia/métodos , Infecções/diagnóstico por imagem
12.
J Ultrasound Med ; 42(1): 201-210, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35603734

RESUMO

OBJECTIVES: Delayed graft function (DGF) is a common early complication after kidney transplantation. The aim of the present study was to evaluate the value of contrast-enhanced ultrasonography (CEUS) in the early prediction of DGF after kidney transplantation. METHODS: A total of 89 renal transplant recipients were retrospectively enrolled and divided into DGF group or normal graft function (NGF) group according to the allograft function. Conventional Doppler ultrasound and CEUS examination data on the first postoperative day were collected and analyzed. RESULTS: The resistive indices of segmental and interlobar artery in the DGF group were significantly higher than those in the NGF group (0.71 ± 0.17 versus 0.63 ± 0.08, P = .006; 0.70 ± 0.16 versus 0.62 ± 0.08, P = .004, respectively). The patients experiencing DGF had significantly lower PI-c (14.7 dB ± 6.1 dB versus 18.5 dB ± 3.3 dB, P = .001) and smaller AUC-c (779.8 ± 375.8 dB·seconds versus 991.0 ± 211.7 dB·seconds, P = .003), as well as significantly lower PI-m (12.6 dB ± 5.9 dB versus 15.9 dB ± 3.9 dB, P = .006), shorter MTT-m (30.7 ± 9.4 seconds versus 36.3 ± 7.1 seconds, P = .01), and smaller AUC-m (P = .007). Multivariate analysis demonstrated that PI-c, AUC-c, and MTT-m were independent risk factors for DGF. The area under the receiver operating characteristic curve values of the combined predicted value (PI-c + MTT-m, PI-c + AUC-c + MTT-m) of DGF incidence were bigger than that of PI-c, AUC-c, or MTT-m. CONCLUSIONS: CEUS parameters of the cortex and medulla have a good value for an early prediction of DGF after renal transplantation.


Assuntos
Transplante de Rim , Ultrassonografia , Humanos , Função Retardada do Enxerto/epidemiologia , Função Retardada do Enxerto/etiologia , Sobrevivência de Enxerto , Transplante de Rim/efeitos adversos , Fator de Crescimento Neural , Estudos Retrospectivos , Fatores de Risco , Ultrassonografia/normas
13.
Ultraschall Med ; 44(3): 280-289, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33757136

RESUMO

OBJECTIVE: To compare the diagnostic accuracy of transvaginal ultrasound (TVS) and magnetic resonance imaging (MRI) for detecting cervical infiltration by endometrial carcinoma using meta-analysis assessment. METHODS: An extensive search of papers comparing TVS and MRI for assessing cervical infiltration in endometrial cancer in the same set of patients was performed in Medline (Pubmed), Web of Science, and the Cochrane Database. Quality was assessed using QUADAS-2 tool (Quality Assessment of Diagnostic Accuracy Studies-2). Quantitative meta-analysis was performed. RESULTS: Our extended search identified 12 articles that used both techniques in the same set of patients and were included in the meta-analysis. The risk of bias for most studies was high for patient selection and index tests in QUADAS-2. Overall, the pooled estimated sensitivity and specificity for diagnosing cervical infiltration in women with endometrial cancer were identical for both techniques [69 % (95 % CI, 51 %-82 %) and 93 % (95 % CI, 90 %-95 %) for TVS, and 69 % (95 % CI, 57 %-79 %) and 91 % (95 % CI, 90 %-95 %) for MRI, respectively]. No statistical differences were found when comparing both methods. Heterogeneity was high for sensitivity and moderate for specificity when analyzing TVS and moderate for both sensitivity and specificity in the case of MRI. CONCLUSION: TVS and MRI showed very similar diagnostic performance for diagnosing cervical involvement in women with endometrial cancer.


Assuntos
Colo do Útero , Neoplasias do Endométrio , Imageamento por Ressonância Magnética , Ultrassonografia , Feminino , Humanos , Colo do Útero/diagnóstico por imagem , Colo do Útero/patologia , Neoplasias do Endométrio/diagnóstico por imagem , Neoplasias do Endométrio/patologia , Imageamento por Ressonância Magnética/normas , Sensibilidade e Especificidade , Ultrassonografia/normas , Período Pré-Operatório
14.
Med Ultrason ; 25(2): 175-188, 2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-36047427

RESUMO

Diagnostic ultrasound in obstetrics and gynaecology has experienced a fantastic evolution during the past seven decades. Initial steps with A-mode technology were followed by B-mode and B-mode real-time imaging, then by Doppler and colour Doppler ultrasound, and finally by 3D/4D ultrasound. Other evolutionary steps were the development of high-resolution transabdominal and transvaginal transducers providing high quality images in the first, second and third trimesters of pregancy, as well as in gynaecology and breast imaging.The progression from two-dimensional (2D) to three-dimensional ultrasound (3D) and 3D real-time imaging (4D) has brought new options in displaying anatomical structures. In comparison with CT or MRI, it is not a static but functional technique, cheap and safe, and applicable at any time.


Assuntos
Ginecologia , Obstetrícia , Ultrassonografia , Ultrassonografia/história , Ultrassonografia/normas , Obstetrícia/história , Obstetrícia/instrumentação , Ginecologia/história , Ginecologia/instrumentação , Humanos , Feminino , Gravidez , Imageamento Tridimensional , Segurança de Equipamentos , História do Século XX , História do Século XXI
15.
Curr Med Sci ; 42(1): 169-176, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35122612

RESUMO

OBJECTIVE: To investigate the value of routine intraoperative ultrasound (IU) and intraoperative contrast-enhanced ultrasound (ICEUS) in the surgical treatment of brain tumors, and to explore the utilization of ICEUS for the removal of the remnants surrounding the resection cavity. METHODS: In total, 51 patients who underwent operations from 2012 to 2018 due to different tumors in the brain were included in this study. The clinical data were evaluated retrospectively. IU was performed in all patients, among which 28 patients underwent ICEUS. The effects of IU and ICEUS on tumor resection and recurrence were evaluated. Semiquantitative analysis was performed to compare ICEUS parameters of the brain tumor with those of the surrounding tissue. RESULTS: In total, 36 male and 15 female patients were included in this study. The average age was 43 years (range: 14-68 years). The follow-up period was from 7 to 74 months (mean follow-up 32 months). IU was used in all patients, and no lesion was missed. Among them, 28 patients underwent ICEUS. The rate of total removal of the ICEUS group (23/28, 82%) was significantly higher than that of the IU group (11/23, 48%) (P<0.05). The recurrence rate of ICEUS and IU was 18% (5/23), and 22% (5/28), respectively, and the difference did not reach statistical significance (P>0.05). The semiquantitative analysis showed that the intensity and the transit time of microbubbles reaching the lesions were significantly different from the intensity and the transit time of microbubbles reaching the surrounding tissue (P<0.05) and reflected indirectly the volume and the speed of blood perfusion in the lesions was higher than those in the surrounding tissue. CONCLUSION: ICEUS is a useful tool in localizing and outlining brain lesions, especially for the resection of the hypervascular lesions in the brain. ICEUS could be more beneficial for identifying the remnants and improving the rate of total removal of these lesions than routine intraoperative ultrasound.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Meios de Contraste/farmacocinética , Monitorização Neurofisiológica Intraoperatória , Procedimentos Neurocirúrgicos , Avaliação de Processos e Resultados em Cuidados de Saúde , Ultrassonografia , Adolescente , Adulto , Idoso , Feminino , Seguimentos , Humanos , Monitorização Neurofisiológica Intraoperatória/métodos , Monitorização Neurofisiológica Intraoperatória/normas , Masculino , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos/métodos , Procedimentos Neurocirúrgicos/normas , Estudos Retrospectivos , Ultrassonografia/métodos , Ultrassonografia/normas , Adulto Jovem
16.
J Feline Med Surg ; 24(12): 1228-1237, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35166136

RESUMO

OBJECTIVES: The aim of this study was to determine whether ultrasonographic pancreatic echogenicity, especially hypoechogenicity, has an impact on the prognosis of cats with suspected pancreatitis. We hypothesised that cats with a hypoechoic pancreas have a longer duration of hospitalisation, higher treatment costs and a higher mortality rate. METHODS: This was a retrospective study, which included cats with clinical signs of pancreatitis, a SNAP fPL test result above the reference interval and ultrasonographic abnormalities consistent with pancreatitis. Medical records and follow-up information were retrieved from the local electronic database. Cases were assigned to one of three groups based on pancreatic echogenicity: hypoechoic, hyperechoic or mixed echogenicity. Statistical analysis aimed to assess differences in outcome, ultrasonographic abnormalities, historical features, physical examination findings, laboratory results, concurrent diseases or treatment costs. RESULTS: Thirty-six (64%) cats with a hypoechoic, seven (13%) with a hyperechoic and 13 (23%) cats with a mixed echoic pancreas were included. Cats with a hypoechoic pancreas had a significantly lower median body weight (P = 0.010) and lower median body condition score (P = 0.004) compared with the other cats. Furthermore, they were presented as being lethargic significantly more often (P = 0.014), were more likely to have a homogeneously enlarged pancreas (P <0.001) and were less likely to have concurrent abnormalities or diseases, such as ultrasonographic enteric abnormalities (P = 0.020), triaditis (P = 0.013) and diabetes mellitus (P = 0.041). However, there was no difference in treatment costs (P = 0.961), duration of hospitalisation (P = 0.898), survival of hospitalisation (P = 0.419) or survival time (P = 0.256) between groups. CONCLUSIONS AND RELEVANCE: In this study, echogenicity was of no prognostic value in cats with suspected pancreatitis. Cats with a hypoechoic pancreas were not associated with a poorer outcome than cats with a hyperechoic or mixed echoic pancreas.


Assuntos
Doenças do Gato , Pancreatite , Ultrassonografia , Animais , Gatos , Estudos Retrospectivos , Ultrassonografia/normas , Pancreatite/diagnóstico por imagem , Pancreatite/veterinária , Valor Preditivo dos Testes , Pâncreas/diagnóstico por imagem , Doenças do Gato/diagnóstico por imagem
18.
Clin Neurophysiol ; 135: 107-116, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35074720

RESUMO

Expert consensus was sought to guide clinicians on the use of electrodiagnostic tests (EDX) and neuromuscular ultrasound (NMUS) in the investigation of suspected carpal tunnel syndrome (CTS). Consensus was achieved using the Delphi method via three consecutive anonymised surveys of 15 experts and was defined as rating agreement ≥ 80%. The panel agreed that combining EDX and NMUS is more informative than using each modality alone. NMUS adds value in patients with clinically suspected CTS with non-localizing or normal EDX, atypical EDX, failed CTS surgery, polyneuropathy, and CTS suspected to be secondary to structural pathology. The median nerve cross-sectional area should be measured at the site of maximal nerve enlargement, and the nerve should be scanned from mid-forearm to the palm. The group also identified those situations where the wrist-to-forearm area ratio and longitudinal scans of the median nerve should also be obtained. EDX should always be performed to quantify CTS severity and in individuals over age 70. This document is an initial step to guide clinicians on the combined investigation of CTS using EDX and NMUS, to be updated regularly with the emergence of new research.


Assuntos
Síndrome do Túnel Carpal/diagnóstico , Eletrodiagnóstico/métodos , Ultrassonografia/métodos , Síndrome do Túnel Carpal/diagnóstico por imagem , Síndrome do Túnel Carpal/fisiopatologia , Consenso , Eletrodiagnóstico/normas , Humanos , Junção Neuromuscular/diagnóstico por imagem , Junção Neuromuscular/fisiologia , Guias de Prática Clínica como Assunto , Ultrassonografia/normas
19.
Am J Physiol Heart Circ Physiol ; 322(3): H359-H372, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34995167

RESUMO

Ischemic heart disease is the leading cause of death in the United States, Canada, and worldwide. Severe disease is characterized by coronary artery occlusion, loss of blood flow to the myocardium, and necrosis of tissue, with subsequent remodeling of the heart wall, including fibrotic scarring. The current study aims to demonstrate the efficacy of quantitating infarct size via two-dimensional (2-D) echocardiographic akinetic length and four-dimensional (4-D) echocardiographic infarct volume and surface area as in vivo analysis techniques. We further describe and evaluate a new surface area strain analysis technique for estimating myocardial infarction (MI) size after ischemic injury. Experimental MI was induced in mice via left coronary artery ligation. Ejection fraction and infarct size were measured through 2-D and 4-D echocardiography. Infarct size established via histology was compared with ultrasound-based metrics via linear regression analysis. Two-dimensional echocardiographic akinetic length (r = 0.76, P = 0.03), 4-D echocardiographic infarct volume (r = 0.85, P = 0.008), and surface area (r = 0.90, P = 0.002) correlate well with histology. Although both 2-D and 4-D echocardiography were reliable measurement techniques to assess infarct, 4-D analysis is superior in assessing asymmetry of the left ventricle and the infarct. Strain analysis performed on 4-D data also provides additional infarct sizing techniques, which correlate with histology (surface strain: r = 0.94, P < 0.001, transmural thickness: r = 0.76, P = 0.001). Two-dimensional echocardiographic akinetic length, 4-D echocardiography ultrasound, and strain provide effective in vivo methods for measuring fibrotic scarring after MI.NEW & NOTEWORTHY Our study supports that both 2-D and 4-D echocardiographic analysis techniques are reliable in quantifying infarct size though 4-D ultrasound provides a more holistic image of LV function and structure, especially after myocardial infarction. Furthermore, 4-D strain analysis correctly identifies infarct size and regional LV dysfunction after MI. Therefore, these techniques can improve functional insight into the impact of pharmacological interventions on the pathophysiology of cardiac disease.


Assuntos
Infarto do Miocárdio/diagnóstico por imagem , Ultrassonografia/métodos , Algoritmos , Animais , Débito Cardíaco , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Imageamento Tridimensional/métodos , Imageamento Tridimensional/normas , Masculino , Camundongos , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Sensibilidade e Especificidade , Ultrassonografia/normas
20.
Brain Res Bull ; 179: 68-73, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34871709

RESUMO

OBJECTIVE: The purpose of the present study was to assess whether optic nerve sheath diameter (ONSD) measured by ultrasound could predict brain injury in sepsis associated encephalopathy (SAE). METHODS: A total of 48 male New Zealand White rabbits were used to establish sepsis model. The levels of neuro-specific enolase (NSE), S100B, myeloperoxidase (MPO), and tumor necrosis factor-α (TNF-α) were detected by enzyme-linked immuno sorbent assay and ONSD were measured before modeling, 6 h, 12 h and 24 h after modeling. Sixteen rabbits were sacrificed for hematoxylin-eosin (HE) staining of brain tissue and the brain water content at above time points. Rabbits demonstrated brain injury by HE staining were included in the SAE group, the others were enrolled in the control group. The correlation between ONSD and MPO, NSE and S100B in the SAE group were analyzed. Receiver operator characteristic curves were generated to analyze the area under the curve (AUC), specificity and sensitivity of ONSD values for SAE. RESULTS: Twenty-nine of 48 rabbits had brain injury, while 19 cases were enrolled in the control group. The level of MPO, NSE, S100B, TNF-α at 6 h, 12 h and 24 h in SAE group were all higher than those of the control group with statistical significance. The ONSD in SAE group increased with time and significantly wider than those in the control group. Correlation analysis revealed that ONSD was positively correlated with MPO, NSE and S100B in the SAE group. The AUCs for the ONSD value in diagnosing SAE at 6 h, 12 h and 24 h were 0.864, 0.957, 0.877, respectively. CONCLUSIONS: Alterations in ONSD strongly correlated with MPO, NSE and S100B among SAE rabbits. Monitoring of ONSD exhibited a high predictive value for SAE.


Assuntos
Nervo Óptico/diagnóstico por imagem , Peroxidase/metabolismo , Fosfopiruvato Hidratase/metabolismo , Subunidade beta da Proteína Ligante de Cálcio S100/metabolismo , Encefalopatia Associada a Sepse/diagnóstico por imagem , Encefalopatia Associada a Sepse/metabolismo , Animais , Biomarcadores/metabolismo , Modelos Animais de Doenças , Humanos , Masculino , Valor Preditivo dos Testes , Coelhos , Ultrassonografia/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA