Anim Reprod Sci ; 267: 107515, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38908170

RESUMO

Several studies have demonstrated the correlation between Doppler velocimetric parameters of testicular artery and semen quality in domestic species, but in felines data are scarce. This study aimed to correlate the Doppler velocimetry of the testicular artery with sperm kinetics and sperm defects, in sedated and non-sedated cats. Forty tomcats were divided into two groups: sedated (SG; n=20) with dexmedetomidine (10 µm/kg) and ketamine (12 mg/kg), and non-sedated (NSG; n=20). The animals were subjected to ultrasound Doppler velocimetry of the distal supratesticular and marginal region of the testicular artery and subsequently orchiectomized. Epididymal tail spermatozoa were recovered and analyzed using a CASA system for motility, and morphology took place. Animals of SG presented a significantly higher velocity in the marginal region of the cat's testicular artery [peak systolic velocity (PSV) 11.51 cm/s; end-diastolic velocity (EDV) 7.72 cm/s] compared to NSG (PSV 7.72 cm/s, P < 0.001; EDV 4.93 cm/s, P < 0.001). Sedated cats presented higher pulsatility and resistivity indexes than non-sedated cats. The supratesticular PSV of NSG was moderately correlated with major (rs = 0621; P < 0.001) and total sperm defects (rs = 0614; P < 0001). Doppler velocimetry was fairly correlated with minor, major, and total sperm defects. In conclusion, Doppler velocimetric evaluation emerges as an important possibility in the reproductive evaluation of tomcats, once the testicular artery hemodynamics were associated with sperm defects. However, it is advisable to carry out this evaluation in non-sedated animals. If sedation is necessary, peripheral vasoconstriction should be considered.


Assuntos
Artérias , Testículo , Ultrassonografia Doppler , Animais , Masculino , Gatos , Testículo/irrigação sanguínea , Testículo/diagnóstico por imagem , Ultrassonografia Doppler/veterinária , Artérias/diagnóstico por imagem , Artérias/fisiologia , Espermatozoides/fisiologia , Análise do Sêmen/veterinária , Velocidade do Fluxo Sanguíneo , Dexmedetomidina/farmacologia , Motilidade dos Espermatozoides , Ketamina/farmacologia , Ketamina/administração & dosagem , Hipnóticos e Sedativos/farmacologia
2.
Res Vet Sci ; 176: 105337, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38875888

RESUMO

The pathogenesis and diagnosis of subclinical pregnancy toxemia (SCPT) remain elusive and need further investigation in pregnant does. Therefore, the aim of our study was to describe the typical properties of hepatic venous hemodynamics by Doppler ultrasonography. A total of 70 pregnant does were classified based on the blood serum concentrations of ß-hydroxybutyric acid (ßHBA), pregnant does were categorized into control group (ßHBA concentrations <0.8 mmol/L; n = 40) and SCPT group (ßHBA concentrations >0.8 mmol/L; n = 30). DRAMISKI 4vet slim diagnostic ultrasound scanner with B, M, and Doppler (color, power, pulsing wave) modes was used for diagnosis of SCPT. Total serum cortisol level was quantitative using chemiluminescent immunoassay. Serum glucose, triglycerides, cholesterol, HDL and LDL- cholesterol and LDH- cholesterol were measured by colorimetric and kinetic methods. Liver ultrasonography of does with SCPT had been shown mild fatty infiltration with rounded margin, which was characterized by hyperechoic area. There was a significant decrease in the values of portal vein diameter (PVD), portal vein area (PVA), portal mean velocity (PMV) and portal blood flow (PBF) in SCPT does compared to control pregnant does. PVD, PVA and PBF were negatively correlated with ßHBA concentrations in does with SCPT (P < 0.05). PVD was inversely associated with serum cholesterol and triglycerides concentrations (P < 0.05). In conclusions, Doppler ultrasonography examinations of pregnant does with SCPT indicate abnormal hepatic variation. Reduced PVD, PVA, PMV and PBF together with increased ßHBA concentrations could predict SCPT in does with fair sensitivity and specificity.


Assuntos
Hidrocortisona , Ultrassonografia Doppler , Feminino , Gravidez , Hidrocortisona/sangue , Ultrassonografia Doppler/veterinária , Animais , Pré-Eclâmpsia/sangue , Pré-Eclâmpsia/diagnóstico por imagem , Ácido 3-Hidroxibutírico/sangue
3.
Vet Radiol Ultrasound ; 65(3): 279-287, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38494832

RESUMO

Cardiovascular changes have been reported in late pregnancy in mares. However, there are no data on changes in peripheral blood flow. Doppler ultrasound represents a sensitive method for assessing the blood flow directed to the hoof. The aims of this study were to evaluate the blood flow parameters of the lateral palmar digital artery (LPDA) in pregnant mares and to assess intra- and interrater agreement between two observers with different levels of experience. The LPDAs of pregnant Italian Standardbred mares were examined. The vessels were located with B-mode ultrasound and analyzed with color and pulsed wave Doppler. The following parameters were recorded by the operators: heart rate (HR), peak systolic velocity (PSV), end-diastolic velocity (EDV), and resistive index (RI). Measurements were performed between 2 and 3 months of gestation (T1), in the last month of pregnancy (T2) and a week after delivery (T3). Seventeen mares aged 3-18 years met the inclusion criteria. Ultrasound examinations of the LPDA were subjectively easy to perform and well tolerated by the mares. Interrater and intrarater agreement were good and moderate, respectively. The HR was higher at T2 than at T1 and T3. The PSV and RI changed significantly during pregnancy, with higher values at T2 and T3, whereas the EDV remained unchanged throughout the examination. Doppler examination showed that peripheral flow changes were present in mares in late pregnancy. However, the persistence of higher values after delivery invites further investigation to assess the correlation between metabolic/endocrine changes related to pregnancy and Doppler parameters.


Assuntos
Prenhez , Animais , Cavalos , Feminino , Gravidez , Ultrassonografia Doppler/veterinária , Artérias/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/veterinária
4.
Am J Vet Res ; 85(6)2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38503051

RESUMO

OBJECTIVE: To compare the accuracy of doppler ultrasound (DOP) and pulse oximeter plethysmography (POP) in the measurement of systolic arterial pressure (SAP) to invasive blood pressure (IBP) in anesthetized dogs. ANIMALS: 40 client-owned healthy dogs > 10 kg. METHODS: Dogs were anesthetized for surgical procedures in dorsal recumbency. Invasive blood pressure was measured from a dorsal pedal artery. DOP and POP device probes were placed over the median caudal artery with a flow-occluding cuff for noninvasive blood pressure measurement. Systolic arterial pressure measured by DOP, loss of pulse oximeter plethysmograph (POPL), and return of pulse oximeter plethysmograph (POPR) were compared to SAP measured by IBP. A linear mixed model was used to determine correlation. Bland-Altman analyses were performed to determine bias, SD, and limits of agreement. The accuracy of DOP and POP was compared to IBP across different tensive states. RESULTS: Conditional R2 values for DOP, POPL, and POPR versus IBP were 0.92, 0.85, and 0.87, respectively (all P < .001). The biases for DOP, POPL, and POPR compared to IBP were +7.6 ± 13.1, +3.9 ± 14.4, and +8.6 ± 15.2 mm Hg (bias ± SD), respectively. Limits of agreement (lower, upper) were (-18.1, +33.3), (-24.3, +32.1), and (-21.2, +38.4) mm Hg for DOP, POPL, and POPR, respectively. DOP and POP overestimated SAP during hypotension (SAP < 90 mm Hg), DOP to a lesser magnitude. CLINICAL RELEVANCE: DOP measured from the median caudal artery may be acceptable for SAP measurement in dorsally recumbent, healthy anesthetized dogs > 10 kg. POP was determined an unacceptable method.


Assuntos
Anestesia , Determinação da Pressão Arterial , Oximetria , Pletismografia , Ultrassonografia Doppler , Animais , Cães , Oximetria/veterinária , Ultrassonografia Doppler/veterinária , Pletismografia/veterinária , Pletismografia/métodos , Masculino , Determinação da Pressão Arterial/veterinária , Determinação da Pressão Arterial/métodos , Anestesia/veterinária , Feminino , Pressão Arterial , Artérias
5.
J Feline Med Surg ; 26(2): 1098612X231216350, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38381465

RESUMO

OBJECTIVES: A comparative assessment of systolic blood pressure (BP) measurement agreement and precision in two commonly used non-invasive BP devices was carried out in conscious cats. METHODS: Systolic BP measurements were obtained from 50 conscious cats as part of their clinical investigations. All measurements were taken by the same operator and were performed according to the American College of Veterinary Internal Medicine (ACVIM) consensus guidelines. The same cuff location and cuff size were used for paired measurements. The order of device use was randomised, and an arousal score was assigned during each procedure. Precision was assessed using standard deviation and coefficient of variance comparisons. Agreement was assessed using graphical and statistical comparisons of derived 'delta mean' and 'mean of means' data. RESULTS: A total of 50 cats aged between 3 months and 15 years were enrolled (29 domestic shorthair, seven domestic longhair, three British Shorthair, two Ragdoll, two Sphynx, two Persian, one Siamese, one Burmese, one Russian Blue, one Maine Coon and one Oriental) with a body weight in the range of 1.2-6.2 kg. BP measurements were in the range of 95-179 mmHg. Oscillometric measurements were associated with lower arousal scores. The Doppler device demonstrated superior repeatability precision. Body weight, sex, cuff size, cuff location, arousal score and the order in which the devices were used had no significant effect on precision or agreement. Correlation between the two devices was 0.0837 and agreement was considered clinically acceptable (<10 mmHg) in 32/50 (64%) cats. Of the 18 cats with suboptimal agreement, the oscillometric mean BP was higher in 14 (78%) cats. CONCLUSIONS AND RELEVANCE: Based on this study sample, suboptimal agreement between paired CAT+ Doppler and SunTech Vet20 oscillometric BP measurements in 36% of conscious cats suggests that these devices should not be used interchangeably. Compared with Doppler, oscillometric measurements were consistently higher, particularly at higher blood pressures. Further studies are required to assess which device has superior accuracy in conscious cats.


Assuntos
Doenças do Gato , Hipertensão , Humanos , Gatos , Animais , Pressão Sanguínea , Ultrassonografia Doppler/veterinária , Hipertensão/veterinária , Peso Corporal , Estado de Consciência
6.
BMC Vet Res ; 19(1): 194, 2023 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-37803319

RESUMO

The objective of the present study was to demonstrate the blood flow velocities, blood flow rate (BFR; bpm) with the accurate ratio of both systolic and diastolic velocities points (S/D) in addition to Doppler indices (resistive and pulsatility index [RI and PI]) in both fetal [fetal heart (FH), fetal abdominal aorta (Ab. A), and umbilical artery (UM.A)] and maternal [Middle uterine artery (MU.A)] sides during the last month of gestation. Ten Zaraibi (Egyptian Nubian) goats weighing 40-50kg and aged from 5-7 years were examined twice per month till reached the last month of pregnancy. Then all females were examined every 5 days starting from day -35 till day -1 before kidding.The pregnant goats were examined by ultrasonic and Doppler indices were recorded with Doppler scanning (7.5 -12 MHz, with colored and spectral graph to form the perfect wave to assess Doppler measurements). The obtained data were analyzed using analysis of variance. Results indicated that on the fetal side; the maximum point of velocity (MSV; cm/sec) in the FH and BFRwere elevated from day -35 till day -10 with a slight decline at days -5 and -1 at the peripartum period (P < 0.05), while FH.PI and S/D ratio declined till day -1(P < 0.05). In addition, the fetal Ab. A, and UM.A PI, RI, and S/D ratio declined from day -35 till day -1 at the peripartum period with a significant increase in the peak systolic velocity (PSV) and BFR(P < 0.05). However, non-significant changes in the end diastolic velocity (EDV) were detected. On the maternal side, the MU.A PI and S/D declined from day -35 till day -1 with an elevation of both PSV and BFRat the same time points (P < 0.05). In conclusion, the Doppler evaluation of fetal and maternal blood flow vessels is important to give complete information that directly affects the health status of the mother and fetus.


Assuntos
Cabras , Período Periparto , Gravidez , Feminino , Animais , Hemodinâmica , Feto/diagnóstico por imagem , Artérias Umbilicais/diagnóstico por imagem , Artérias Umbilicais/fisiologia , Velocidade do Fluxo Sanguíneo/veterinária , Ultrassonografia Doppler/veterinária
7.
Anat Histol Embryol ; 52(6): 1003-1009, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37668174

RESUMO

Currently, the effect of prenatal ultrasound on foetal development is intensively discussed and the guidelines for prenatal diagnostics have been changed. However, data supporting these concerns are scarce. Therefore, we used an established in ovo model of the chicken embryo to investigate cell proliferation and apoptosis within the retina. A total of 21 chicken eggs were fenestrated on Day 5 and allocated to either the control (n = 8) or exposition group (n = 13). The exposition group was treated with pulsed-wave Doppler ultrasound (PWD) for 10 min while controls remained without treatment. After subsequent incubation (6-48 h), the eggs were sacrificed, and chicken embryos were examined morphologically (HE-staining) and immunohistochemically. Counting of apoptotic and proliferating cells per retina was performed using antibodies specific for phospho-histone-H3 and active caspase-3 in combination with a biotin-labelled secondary antibody and peroxidase conjugated avidin-biotin complex for chromogenic detection. Due to a rather low number of specimens at each time point after ultrasound exposition, we neglected the effects of incubation time and focused on treatment effects. This approach revealed that the median number of proliferating cells is reduced after 10 min of exposure to PWD (569 vs. 766), while the number of apoptotic cells is fairly comparable between groups (5 vs. 6). Our data contribute to a better understanding of prenatal US on foetal development by suggesting that PWD could have an impact on the number of proliferating cells in the developing chicken retina and therefore justify further investigations.


Assuntos
Biotina , Ultrassonografia Doppler , Embrião de Galinha , Animais , Feminino , Ultrassonografia , Ultrassonografia Doppler/veterinária , Angiografia , Apoptose , Galinhas , Retina/diagnóstico por imagem
8.
Am J Vet Res ; 84(11)2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37657735

RESUMO

OBJECTIVE: To investigate hemodynamics and morphology of hip joint vasculature in cats with the use of color and pulsed-wave Doppler ultrasonography. ANIMALS: 30 client-owned healthy skeletally immature cats presented for routine examinations between September 7, 2022, and March 25, 2023. METHODS: Cats between 3.5 to 18 months old with healthy hip joints and Hct within reference ranges (26% to 44.2%) were eligible for inclusion. Color and pulsed-wave Doppler ultrasonography was performed without sedation. Peak systolic velocity (PSV), mean diastolic velocity (MDV), resistance index (RI), and pulsatility index (PI) were measured for major arteries of the hip joints. RESULTS: Intermediate pulsatility, resistance to flow, and pandiastolic anterograde flow were evident for all arteries evaluated for each joint except for the ligamentum capitis ossis femoris artery (LCOFA). Spectral waveforms for the LCOFA showed a low-resistance pattern with continuous forward diastolic flow. No significant differences were found in the mean PI or MDV between the left and right sides for the ascending branch of the lateral circumflex femoral artery or in the mean PI of the ascending branch of the medial circumflex femoral artery. Mean PSV of the LCOFA was lower (but nonsignificantly) for left hip joints vs right hip joints, whereas other values were often higher on cats' left side vs their right. CLINICAL RELEVANCE: This study provided insight into the morphology and hemodynamics of the femoral head vasculature in skeletally immature cats and showed Doppler ultrasound values to study the clinically normal blood supply to hip joints in cats.


Assuntos
Hemodinâmica , Articulação do Quadril , Humanos , Gatos , Animais , Ultrassonografia , Articulação do Quadril/diagnóstico por imagem , Artérias , Ultrassonografia Doppler de Pulso , Velocidade do Fluxo Sanguíneo/veterinária , Ultrassonografia Doppler/veterinária , Ultrassonografia Doppler em Cores/veterinária
9.
Animal ; 17 Suppl 1: 100752, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37567660

RESUMO

A number of potentials uses of Doppler ultrasonography have been explored in the last decades, both as research tools in reproductive physiology investigations and for the reproductive management of farm animals. The objective of this review was to address some of the recent strategies developed in fixed-time reproductive programs and resynchronization of ovulation in cattle, based on the evaluation of corpus luteum function by color-Doppler ultrasound imaging. Recent studies in dairy and beef cattle pointed out to a high accuracy when Doppler ultrasonography is used to assess the functionality of the corpus luteum and identify non-pregnant females at 20-24 days after breeding. Therefore, super-early resynchronization programs starting in the second week after timed-artificial insemination or embryo transfer have been developed and are being implemented in commercial assisted reproduction programs; thus, anticipating conception with proven semen or genetically superior embryos. In addition, assessment of corpus luteum blood perfusion can be used for identifying high fertility embryo recipients in fixed-time embryo transfer programs.


Assuntos
Corpo Lúteo , Progesterona , Feminino , Bovinos , Animais , Corpo Lúteo/diagnóstico por imagem , Ovulação , Reprodução , Ultrassonografia/veterinária , Ultrassonografia Doppler/veterinária , Inseminação Artificial/veterinária , Sincronização do Estro
10.
J Feline Med Surg ; 25(8): 1098612X231183244, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37548534

RESUMO

OBJECTIVES: A questionnaire was designed to survey veterinarians and veterinary nurses/technicians on blood pressure (BP) assessment in cats, including ocular examination, encompassing current methodology, indications, uptake and barriers. METHODS: An online questionnaire was produced and promoted to more than 2000 veterinary professionals, of whom 545 answered all questions and 85 answered most questions. RESULTS: Of the participants, 572 (90.8%) were based in the UK and almost all (n = 613, 97.3%) had access to a BP monitor. Of those that had a monitor, most (n = 550, 88.4%) participants had access to a Doppler monitor; 367 (59.0%) participants had access to multiparameter monitors; fewer (n = 202, 32.5%) had access to oscillometric BP monitors. Where applicable, Doppler monitors were most commonly chosen for conscious cat measurements (n = 337, 72.2%) due to the greater 'trust' and 'reliability' of these compared with oscillometric machines. Conscious BP measurement typically involved two members of staff (n = 391, 62.9%). Only 156 (29.1%) participants recommended BP assessment at least several times a week in their interactions with cat owners. BP assessment was routinely recommended in cats with ocular target organ damage (n = 365, 87.7%), chronic kidney disease (n = 346, 78.6%), proteinuria (n = 255, 63.0%) and hyperthyroidism (n = 266, 60.9%). Common equipment-related barriers included 'cuff frustration' and difficulties hearing the pulse signal for Doppler users (72.2% and 71.6%, respectively), and oscillometric machines failing to give a reading at least some of the time (52.8%). Situational hypertension concerns affected many (n = 507, 92.0%), as did lack of time to do the procedure (n = 402, 73.0%). Significant owner barriers included difficulties persuading the owner to bring their cat in for BP checks (n = 475, 86.2%) and concerns over costs (n = 445, 80.8%). Most participants had access to a direct ophthalmoscope (n = 527, 96.5%); however, 399 (73.1%) reported that they struggled to interpret ocular findings. CONCLUSIONS AND RELEVANCE: Significant barriers exist to successful BP assessment in cats. Education and support of clinics should focus on improving confidence with equipment and eye examination.


Assuntos
Doenças do Gato , Hipertensão , Insuficiência Renal Crônica , Gatos , Animais , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/veterinária , Hipertensão/veterinária , Ultrassonografia Doppler/veterinária , Insuficiência Renal Crônica/veterinária , Monitores de Pressão Arterial/veterinária , Doenças do Gato/diagnóstico
11.
Tomography ; 9(4): 1408-1422, 2023 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-37489480

RESUMO

The objectives were (a) the study of haemodynamic parameters of blood flow within the testicular artery, (b) the assessment of differences in these parameters at different segments of the artery (i.e., sequentially, as the artery flows through different regions of the testis), and (c) the identification of potential associations with measures of testicular maturation. Eight healthy beagle-breed male dogs were monitored at fortnightly intervals from the 4th to the 40th week of life, by using clinical, seminological, and ultrasonographic (B-mode, pulsed-wave Doppler) examinations. Haemodynamic parameters were assessed at four different segments of the testicular artery: at the distal supra-testicular, the marginal testicular at the cranial pole of the testis, the marginal testicular at the caudal pole of the testis, and the intratesticular. The study period was divided into three time slots (pre-puberty, puberty, and post-puberty) depending on testicular maturation and sperm production. No clinically evident abnormalities were seen in any animal throughout the study. Semen ejaculates were first collected on the 28th week, and spermatozoa were first seen on the 30th week of life. The results of B-mode examination indicated that in all dogs, the echogenicity of the testicular parenchyma was homogeneous. The waveforms of the blood flow in the testicular artery were monophasic with systolic peaks, low diastolic flow, and low vascular resistance. Most cases of significant differences between the three age periods were noted for the comparison of the pre-pubertal to pubertal periods (n = 11); among the parameters studied, the blood volume (n = 9) showed most instances of significant differences; finally, most cases of significant differences were noted in the distal supra-testicular artery (n = 12). Correlations were mainly seen for the end diastolic velocity, the peak systolic velocity and the blood volume (each with two semen evaluation parameters). The distal supra-testicular and the marginal artery at the cranial pole of the testis are recommended as the most appropriate segments of the vessel for performing a Doppler examination in the testicular artery due to the adequate size and the clear spectral waveforms as early as the 12th week of age of the animals.


Assuntos
Análise do Sêmen , Sêmen , Masculino , Cães , Animais , Análise do Sêmen/veterinária , Maturidade Sexual , Ultrassonografia Doppler/métodos , Ultrassonografia Doppler/veterinária , Artérias/diagnóstico por imagem
12.
Vet Med Sci ; 9(4): 1456-1459, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37311923

RESUMO

BACKGROUND: No study has been performed regarding the effects of oral administration of propranolol on pulse-wave spectral Doppler indices of major abdominal vessels in healthy adult cats. OBJECTIVE: The objective of this study was to assess the pulse-wave spectral Doppler indices of abdominal aorta, caudal vena cava, and portal vein in clinically normal adult domestic short-haired (DSH) cats, before and after propranolol ingestion. METHODS: Twenty intact adult client-owned DSH cats were evaluated (10 males and 10 females). A duplex Doppler ultrasonography machine with a 10-MHz frequency linear transducer was used. Peak systolic velocity, end-diastolic velocity (EDV), resistive index (RI), pulsatility index (PI), and pressure gradient were measured. All the cats received 1 mg/kg of propranolol tablet, and after 2 h, ultrasonography measurements were repeated. RESULTS: The mean RI of the aorta and caudal vena cava significantly decreased in male cats following oral administration of propranolol after 2 h (p = 0.03, p = 0.02). In the caudal vena cava, the PI decreased from 2.98 ± 0.62 to 1.15 ± 0.19 post-propranolol ingestion (p = 0.01). The mean EDV in the caudal vena cava of males and portal veins of females significantly decreased after propranolol ingestion (p = 0.04, p = 0.02). CONCLUSIONS: This study showed that propranolol decreased the PI of the aorta and PI and RI of the caudal vena cava in healthy normal cats 2 h post-propranolol ingestion at the dosage of 1 mg/kg.


Assuntos
Aorta , Propranolol , Feminino , Masculino , Animais , Velocidade do Fluxo Sanguíneo/veterinária , Fluxo Pulsátil , Ultrassonografia Doppler/veterinária
13.
Res Vet Sci ; 160: 18-25, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37235922

RESUMO

Contrary to its widespread use in human cases, the use of Doppler ultrasonography is only recently becoming prevalent in farm animals. This study aimed to determine the effects of maternal metabolic and clinical changes on fetal hemodynamics during pregnancy toxemia with the doppler examination of umbilical cord. In the study twenty ewes with a single healthy fetus were included in the study. At the end of the 120th day of pregnancy, 20 single-bearing pregnant ewes were randomly categorized into two groups. Ewes in the control group were fed to meet all nutritional requirements. On the other contrary, the experimental ewes were fed to meet equivalent to 50 % of the daily needs and then fasted for 96 h. Doppler ultrasonographic examinations of umbilical cord were performed once every two days and once a day during fasting. Beta hydroxybutyric acid (BHBA) concentration was measured by taking blood from sheep on examination days. Pulse systolic velocity (PSV), end diastolic velocity (EDV), PSV/EDV, pulsatility index (PI), resistance index (RI), and fetal heart rate (FHR) as well as BHBA values and how those parameters has changed over time (time by treatment effect) due to energy deprivation during pregnancy were evaluated using repeated measure analysis of variance. No clinical signs were observed in both toxemia and control groups during restricted feeding. BHBA concentration increased and there was a significant time, time by treatment and main effect of treatment effect between groups. No significant main effect of treatment and time by treatment interaction was observed in the changes of PI, RI, FHR, and systolic/diastolic velocity values over time in both groups. FHR was reduced over time, and there was a significant time effect in FHR in both groups. Although doppler indices didn't increase, both PSV and EDV values increased significantly in the pregnancy toxemia group compared with the controls (Time P = 0.03, time by treatment interaction P < 0.05) and the main effect of treatment P < 0.05). The marked increase in blood velocities (PSV and EDV) in the umbilical cord is probably due to the compensatory functioning for excessive energy deprivation of the fetus. Therefore, PSV and EDV might be a valuable indicator for evaluating the fetus's health status during the management of the PT.


Assuntos
Pré-Eclâmpsia , Doenças dos Ovinos , Animais , Feminino , Gravidez , Velocidade do Fluxo Sanguíneo/fisiologia , Velocidade do Fluxo Sanguíneo/veterinária , Pré-Eclâmpsia/veterinária , Ovinos , Ultrassonografia , Ultrassonografia Doppler/veterinária , Cordão Umbilical/diagnóstico por imagem
14.
J Am Vet Med Assoc ; 261(7): 1-8, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-36853876

RESUMO

OBJECTIVE: Agreement of systolic blood pressure measurements (SBP) between noninvasive blood pressure devices in conscious dogs is poorly studied. Situational hypertension is expected in clinics, but studies are lacking. This study aimed to compare SBP measurements obtained with Doppler ultrasonic flow detector (Doppler) versus high-definition oscillometry (HDO) in clinics and at home and to estimate the prevalence of situational hypertension in conscious, apparently healthy elderly dogs. ANIMALS: 122 apparently healthy elderly or geriatric dogs were prospectively recruited. PROCEDURES: Systolic blood pressure was obtained consecutively with Doppler and HDO techniques in a randomized order per dog, following a standardized protocol. An at-home measurement was advised for in-clinic hypertensive dogs (SBP ≥ 160 mmHg), also using both devices. RESULTS: Dual measurements were available in 102 dogs. Median SBP was 147.3 mmHg (range, 105 to 239 mmHg) for Doppler and 152.3 mmHg (range, 113 to 221 mmHg) for HDO. Forty-six percent (56/122) were hypertensive, of which 9% (11/122) were hypertensive with both methods. No significant difference was found between the 2 devices in the global study population or within the group of hypertensive dogs. Repeated at-home measurements were performed in 20/56 (35.7%) hypertensive dogs, resulting in a 10 and 26 mmHg lower median SBP value for Doppler and HDO, respectively (P > .05). In-clinic situational hypertension was presumed in 8/20 (40%) dogs. CLINICAL RELEVANCE: The choice of the noninvasive blood pressure device did not significantly impact SBP results, but large interindividual differences in SBP between techniques occurred. Situational hypertension was frequently observed in clinic.


Assuntos
Doenças do Cão , Hipertensão , Animais , Cães , Pressão Sanguínea , Determinação da Pressão Arterial/veterinária , Determinação da Pressão Arterial/métodos , Doenças do Cão/diagnóstico , Hipertensão/diagnóstico , Hipertensão/veterinária , Individualidade , Oscilometria/veterinária , Oscilometria/métodos , Ultrassonografia Doppler/veterinária
15.
J Feline Med Surg ; 25(1): 1098612X221145477, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36649073

RESUMO

OBJECTIVES: Ultrasonography is used in the evaluation of urinary disorders, and the resistivity index (RI) and pulsatility index (PI) have been successfully used to detect early hemodynamic changes in the course of kidney diseases in humans and dogs. The aim of this study was to investigate RI and PI in cats with feline lower urinary tract disease (FLUTD). METHODS: Twenty-nine client-owned cats were selected and divided into a control group (CG; n = 10), a group of animals with obstructive FLUTD (OG; n = 11) and non-obstructive FLUTD (nOG; n = 8). Clinical, laboratory and ultrasound evaluations were performed in all cats. RESULTS: RI and PI values for cats in the CG were below the upper limit of normal suggested in other studies, while cats with FLUTD showed significantly higher values in the assessment of RI (P = 0.027 and P = 0.034, respectively) and PI (P = 0.044 and P = 0.048, respectively) of the right and left kidneys. CONCLUSIONS AND RELEVANCE: Alteration in renal blood flow was observed in cats with lower urinary tract disorders, even in the nOG group. To the best of our knowledge, this is the first report of renal blood flow changes related to non-obstructive FLUTD.


Assuntos
Doenças do Gato , Doenças Urológicas , Animais , Gatos , Doenças do Gato/diagnóstico , Rim/irrigação sanguínea , Ultrassonografia/veterinária , Ultrassonografia Doppler/veterinária , Doenças Urológicas/veterinária
16.
Vet Radiol Ultrasound ; 64(2): 337-344, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36447301

RESUMO

Renal impairment is concurrent with adverse outcomes such as heart disease in humans and dogs. Intrarenal Doppler ultrasonography (IRD) is used to assess intrarenal hemodynamics, and resistance index (RI) and venous impedance index (VII) are used to evaluate intrarenal hemodynamics in humans with heart failure. However, only a few studies have assessed the efficacy of IRD, especially VII, in dogs, and the methods differ between studies. Additionally, repeatability, reproducibility, and factors influencing IRD values have not been validated in dogs. This prospective, analytical study aimed to assess repeatability and reproducibility of IRD, and to clarify influencing factors of IRD in dogs without heart disease. We enrolled 78 dogs without heart disease. The RI and VII were highly reproducible, and the reference intervals for VII were 0.13-0.37. Differences in transducer (sector and convex) and posture (right lateral and supine decubitus position) had no effect on the IRD values. In contrast, RI and VII were higher in the renal vessels than in interlobar vessels. Age affected RI values (r = 0.39, P < 0.001), but there was no correlation between age, body weight, and VII. In conclusion, IRD is a repeatable and reproducible method to assess intrarenal hemodynamics in dogs. The findings also suggest that age should be considered while interpreting RI.


Assuntos
Doenças do Cão , Insuficiência Cardíaca , Humanos , Cães , Animais , Resistência Vascular , Ultrassonografia Doppler/veterinária , Estudos Prospectivos , Reprodutibilidade dos Testes , Insuficiência Cardíaca/veterinária , Rim/diagnóstico por imagem
17.
BMC Vet Res ; 18(1): 404, 2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36380376

RESUMO

This study aimed to correlate the pulsed wave spectral indices of the middle uterine artery at both sides with placental development in jenny within mid-late pregnancies, and establish umbilical Doppler values for different ages and different gestational months. Twenty Equus Asinus pregnant jennies 260-450 kg (average, 320 ± 10 kg) were examined from 5 to 9 months of pregnancy with different ages (4-14 years). Monthly B-mode ultrasound examination was performed on both the combined thickness of the uterus and placenta (CTUP; mm) and umbilical artery cross-sectional diameter, and Doppler mode examination was performed on both the middle uterine (MUA at right [R] and left [L] sides) and umbilical arteries to measure both Doppler indices that expressed by resistance (RI) and pulsatility indices (PI), and blood flow rate. CTUP was elevated within pregnancy time at different ages (P < 0.05). L. PI was significantly declined throughout different ages (P < 0.05), but this declining trend was not observed in L. RI. The L. blood flow rate (R; bpm) was elevated among different ages and different months (P < 0.05). Both RI and PI were significantly decreased from 5 to 9 month of gestation period in jennies (P < 0.05).. The umbilical arteries cross-sectional diameter (Umb A; mm), was elevated among different ages and different months, while both Doppler indices were declined. A positive correlation was found (between both Doppler indices of both umbilical and uterine arteries P < 0.001). There was elevated vascular perfusion in uterine and umbilical arteries associated with reduced both Doppler indices along the course of pregnancy at different ages.


Assuntos
Equidae , Artérias Umbilicais , Feminino , Gravidez , Animais , Artérias Umbilicais/diagnóstico por imagem , Artérias Umbilicais/fisiologia , Placenta/diagnóstico por imagem , Ultrassonografia Pré-Natal/veterinária , Velocidade do Fluxo Sanguíneo , Ultrassonografia Doppler/veterinária , Útero/diagnóstico por imagem , Hemodinâmica , Envelhecimento , Perfusão/veterinária
18.
Theriogenology ; 194: 162-170, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36265337

RESUMO

The aim of the present study was to evaluate the vascularization features of canine ovaries during the follicular phase and the formation of the corpora lutea by using Doppler ultrasonography and Contrast-Enhanced Ultrasound (CEUS). Eight healthy bitches were enrolled in the study and were evaluated at five different timepoints (T1 - T5) of the estrous cycle established by vaginal cytology and serum progesterone concentration. Ultrasonographic examinations were performed by a single operator using the ACUSON S2000/SIEMENS machine equipped with a linear multifrequency transducer (9.0 MHz). Color-coded Doppler evaluation of the ovarian parenchyma was performed to investigate the aspects of the signal detection throughout the different timepoints. Pulsed-wave Doppler of the intraovarian arteries was performed to evaluate spectral waveform and doppler velocimetric parameters of Systolic Peak Velocity (SPV cm/s), End Diastolic Velocity (EDV cm/s), Resistivity Index (RI) and Pulsatility Index (PI). CEUS evaluation of the ovaries was performed using a vascular contrast agent (SonoVue®, Bracco, Sao Paulo, Brazil) and the CADENCE™ Contrast Pulse Sequencing (CPS, Siemens) software, in order to perform both qualitative and quantitative analysis. Perfusion parameters of pixel number, peak intensity (PPI in %), time to peak intensity (TTP in s), mean transit time (MTT in s) and area under the curve (AUC in %). Colour-coded Doppler evaluation demonstrated an increase in signal detection as cycle progressed, with blood flow initially detected with few coloured pixels and mainly at the ventral surface of the ovaries. Further on, the number of coloured pixels increased and spreading to the central region, resulting in a circular-like pattern around the corpora hemorrhagica. The spectral waveform was consistent at all timepoints. SPV (cm/s) and EDV (cm/s) presented a numeric trend and a slight statistical difference at all timepoints, whereas no difference was found for RI and PI. CEUS evaluation demonstrated an increase in pixel intensity across all the timepoints. Quantitative CEUS analysis revealed a statistical difference in PPI (%), MTT (s) and AUC (%) at T5. CEUS evaluation of the ovaries was feasible and demonstrated a marked increase in perfusion parameters in the late postovulatory period, demonstrating its applicability in the assessment of canine corpora lutea development.


Assuntos
Ovário , Ultrassonografia Doppler , Feminino , Cães , Animais , Ovário/diagnóstico por imagem , Ovário/irrigação sanguínea , Brasil , Ultrassonografia/métodos , Ultrassonografia Doppler/veterinária , Corpo Lúteo/diagnóstico por imagem , Estro , Ultrassonografia Doppler em Cores
19.
Open Vet J ; 12(4): 562-566, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36118718

RESUMO

Background: The acquisition of systemic blood pressure (SBP) provides valuable information regarding cardiovascular function and tissue perfusion in human and veterinary species. Aim: To evaluate the agreement between Parks Medical Doppler (PMD) and Mano Médical Vet BP (MMVBP) Doppler for assessing SBP in conscious dogs. Methods: 40 client-owned dogs were prospectively enrolled; SBP measurements were acquired by a single operator using the PMD and then the MMVBP. The mean of five consecutive measurements for each device was classified according to target organ damage (TOD) risk scores (1: <140 mmHg; 2: 140-160 mmHg; 3: 160-180 mmHg; 4: ≥ 180 mmHg). Results: Total mean SBP for the devices was not statistically different (p = 0.77). However, the Bland-Altman analysis revealed wide limits of agreement (LoA), with MMVBP slightly underestimating SBP compared to PMD (bias = -0.6 mmHg, 95% LoA: -26.3 to 25.09). Both devices correlated well ( r = 0.8269; p < 0.0001) and had identically acceptable intra-observer repeatability (coefficients of variation = 4.09% for MMVBP and 3.86% for PMD). Four dogs (10%) had a TOD score of 3 by one device but scored <3 with the other. Conclusion: A good agreement and correlation was observed between the PMD and the MMVBP, suggesting that both devices can be used interchangeably for assessment of SBP in conscious dogs. The wide LoA observed between both devices was most likely associated with intraindividual variability in SBP over time.


Assuntos
Determinação da Pressão Arterial , Ultrassonografia Doppler , Animais , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/veterinária , Cães , Humanos , Oscilometria/veterinária , Ultrassonografia Doppler/veterinária
20.
BMC Vet Res ; 18(1): 326, 2022 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-36042514

RESUMO

BACKGROUND: Ultrasonography is one of the most important techniques that enable the detection and monitoring of pregnancy. One such study using this technique is the assessment of the hemodynamics of fetal and umbilical blood vessels. However, there is little data on blood flow in the placentomes, which is the basic structural unit of the sheep's placenta. Therefore, the aim of this study was to determine the Doppler parameters in the arterial vessels of the caruncles, cotyledons and the umbilical cord as well as measuring venous flow rates during the entire gestation period of the sheep. Additionally, the usefulness of various other ultrasound parameters in the early diagnosis of pregnancy in sheep was analyzed. RESULTS: Most of the Doppler parameters in umbilical, cotyledonary and caruncular arteries were significantly correlated with the day of pregnancy (p < 0.01). In the early stages of pregnancy, the peak systolic velocity (PSV), regardless of the location of the artery, was significantly lower than that in the later stages of pregnancy (p < 0.01). PSV was also found to be significantly higher in the umbilical artery than in the cotyledonary and caruncular arteries (p < 0.01). Until the 50th day of pregnancy, the end diastolic velocity (EDV) was not found in the umbilical and cotyledonary arteries. EDV was significantly higher in the caruncular arteries than in the cotyledonary and umbilical arteries (p < 0.01). The resistance index (RI) and pulsatility index (PI) in the early stages of pregnancy were found to be significantly higher than that in the later stages of pregnancy (p < 0.01). The RI and PI were significantly lower in the caruncular arteries than in the arteries of the cotyledons and umbilical cord (p < 0.01). In the umbilical vein, all Doppler parameters were observed to be significantly higher than those in the placentomal veins (p < 0.01 or p < 0.05). Using transrectal ultrasound, pregnancy was detected between 20 and 28 days after mating. The ovaries were observed to have corpora lutea, the diameter of which was fairly consistent from the 17th to the 56th day of pregnancy. CONCLUSIONS: It has been demonstrated that both the location of the arterial vessel in the placental-umbilical circulation and the gestational age have a significant impact on hemodynamic parameters. The results also provide new insights about the blood flow in caruncular and cotyledonary arteries, which could contribute to a more holistic understanding of hemodynamic changes in the placentas of sheep. Analyzing haemodynamic parameters in the umbilical and placental veins are preliminary studies in sheep, but it could inspire further research in this field. Furthermore, the research conducted confirms the practicality and convenience of transrectal ultrasonography in the early diagnosis of pregnancy in sheep and also indicates that the identification and imaging of the corpus luteum using B-mode ultrasonography can be a very early and simple method of confirming effective mating in sheep.


Assuntos
Placenta , Ultrassonografia Pré-Natal , Animais , Velocidade do Fluxo Sanguíneo/veterinária , Feminino , Placenta/diagnóstico por imagem , Gravidez , Ovinos , Ultrassonografia , Ultrassonografia Doppler/veterinária , Ultrassonografia Pré-Natal/veterinária , Artérias Umbilicais/irrigação sanguínea , Artérias Umbilicais/diagnóstico por imagem , Artérias Umbilicais/fisiologia
SELEÇÃO DE REFERÊNCIAS