Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.269
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38765504

RESUMO

Objective: To compare the medical image interpretation's time between the conventional and automated methods of breast ultrasound in patients with breast lesions. Secondarily, to evaluate the agreement between the two methods and interobservers. Methods: This is a cross-sectional study with prospective data collection. The agreement's degrees were established in relation to the breast lesions's ultrasound descriptors. To determine the accuracy of each method, a biopsy of suspicious lesions was performed, considering the histopathological result as the diagnostic gold standard. Results: We evaluated 27 women. Conventional ultrasound used an average medical time of 10.77 minutes (± 2.55) greater than the average of 7.38 minutes (± 2.06) for automated ultrasound (p<0.001). The degrees of agreement between the methods ranged from 0.75 to 0.95 for researcher 1 and from 0.71 to 0.98 for researcher 2. Among the researchers, the degrees of agreement were between 0.63 and 1 for automated ultrasound and between 0.68 and 1 for conventional ultrasound. The area of the ROC curve for the conventional method was 0.67 (p=0.003) for researcher 1 and 0.72 (p<0.001) for researcher 2. The area of the ROC curve for the automated method was 0. 69 (p=0.001) for researcher 1 and 0.78 (p<0.001) for researcher 2. Conclusion: We observed less time devoted by the physician to automated ultrasound compared to conventional ultrasound, maintaining accuracy. There was substantial or strong to perfect interobserver agreement and substantial or strong to almost perfect agreement between the methods.


Assuntos
Neoplasias da Mama , Ultrassonografia Mamária , Humanos , Feminino , Estudos Transversais , Ultrassonografia Mamária/métodos , Estudos Prospectivos , Adulto , Fatores de Tempo , Pessoa de Meia-Idade , Neoplasias da Mama/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador
2.
J Cancer Res Ther ; 20(2): 665-668, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38687938

RESUMO

AIMS: The aims of this study were to investigate the ultrasound features of non-mass-type ductal carcinoma in situ (DCIS) of the breast and conduct a pathological analysis. MATERIAL AND METHODS: Ultrasound images of 32 cases of non-mass-type DCIS of the breast, collected between September 2014 and June 2016, were analyzed. The characteristics of the lesions, including border, internal echogenicity, local glandular hyperplasia, micro-calcification, and intra-tumoral blood flow resistance index (RI), were analyzed, and a concurrent pathological analysis was conducted. RESULTS: Obvious local glandular hyperplasia was commonly observed in the 32 cases of non-mass-type DCIS of the breast. The internal echogenicity varied in intensity, exhibiting a "leopard pattern" or "zebra pattern." Color Doppler imaging revealed abundant blood flow signals within the lesion with an RI of >0.7. Isolated duct dilatation and micro-calcifications were occasionally observed within the lesions. High-grade DCIS was the predominant pathological type of non-mass-type DCIS. CONCLUSIONS: Non-mass-type DCIS of the breast often presents with obvious local glandular hyperplasia and varying internal echogenicity. High-grade DCIS is the frequent pathological type. Color Doppler imaging and RI measurement can assist in diagnosing non-mass-type DCIS of the breast.


Assuntos
Neoplasias da Mama , Carcinoma Intraductal não Infiltrante , Humanos , Feminino , Neoplasias da Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Pessoa de Meia-Idade , Carcinoma Intraductal não Infiltrante/patologia , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/diagnóstico , Idoso , Adulto , Hiperplasia/patologia , Hiperplasia/diagnóstico por imagem , Ultrassonografia Mamária/métodos , Mama/patologia , Mama/diagnóstico por imagem , Ultrassonografia Doppler em Cores/métodos , Gradação de Tumores
3.
Tomography ; 10(4): 554-573, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38668401

RESUMO

This review provides unique insights to the scientific scope and clinical visions of the inventors and pioneers of the SoftVue breast tomographic ultrasound (BTUS). Their >20-year collaboration produced extensive basic research and technology developments, culminating in SoftVue, which recently received the Food and Drug Administration's approval as an adjunct to breast cancer screening in women with dense breasts. SoftVue's multi-center trial confirmed the diagnostic goals of the tissue characterization and localization of quantitative acoustic tissue differences in 2D and 3D coronal image sequences. SoftVue mass characterizations are also reviewed within the standard cancer risk categories of the Breast Imaging Reporting and Data System. As a quantitative diagnostic modality, SoftVue can also function as a cost-effective platform for artificial intelligence-assisted breast cancer identification. Finally, SoftVue's quantitative acoustic maps facilitate noninvasive temperature monitoring and a unique form of time-reversed, focused US in a single theranostic device that actually focuses acoustic energy better within the highly scattering breast tissues, allowing for localized hyperthermia, drug delivery, and/or ablation. Women also prefer the comfort of SoftVue over mammograms and will continue to seek out less-invasive breast care, from diagnosis to treatment.


Assuntos
Neoplasias da Mama , Ultrassonografia Mamária , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/terapia , Feminino , Ultrassonografia Mamária/métodos , Detecção Precoce de Câncer/métodos , Nanomedicina Teranóstica/métodos , Mama/diagnóstico por imagem , Mama/patologia
4.
Radiology ; 311(1): e232133, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38687216

RESUMO

Background The performance of publicly available large language models (LLMs) remains unclear for complex clinical tasks. Purpose To evaluate the agreement between human readers and LLMs for Breast Imaging Reporting and Data System (BI-RADS) categories assigned based on breast imaging reports written in three languages and to assess the impact of discordant category assignments on clinical management. Materials and Methods This retrospective study included reports for women who underwent MRI, mammography, and/or US for breast cancer screening or diagnostic purposes at three referral centers. Reports with findings categorized as BI-RADS 1-5 and written in Italian, English, or Dutch were collected between January 2000 and October 2023. Board-certified breast radiologists and the LLMs GPT-3.5 and GPT-4 (OpenAI) and Bard, now called Gemini (Google), assigned BI-RADS categories using only the findings described by the original radiologists. Agreement between human readers and LLMs for BI-RADS categories was assessed using the Gwet agreement coefficient (AC1 value). Frequencies were calculated for changes in BI-RADS category assignments that would affect clinical management (ie, BI-RADS 0 vs BI-RADS 1 or 2 vs BI-RADS 3 vs BI-RADS 4 or 5) and compared using the McNemar test. Results Across 2400 reports, agreement between the original and reviewing radiologists was almost perfect (AC1 = 0.91), while agreement between the original radiologists and GPT-4, GPT-3.5, and Bard was moderate (AC1 = 0.52, 0.48, and 0.42, respectively). Across human readers and LLMs, differences were observed in the frequency of BI-RADS category upgrades or downgrades that would result in changed clinical management (118 of 2400 [4.9%] for human readers, 611 of 2400 [25.5%] for Bard, 573 of 2400 [23.9%] for GPT-3.5, and 435 of 2400 [18.1%] for GPT-4; P < .001) and that would negatively impact clinical management (37 of 2400 [1.5%] for human readers, 435 of 2400 [18.1%] for Bard, 344 of 2400 [14.3%] for GPT-3.5, and 255 of 2400 [10.6%] for GPT-4; P < .001). Conclusion LLMs achieved moderate agreement with human reader-assigned BI-RADS categories across reports written in three languages but also yielded a high percentage of discordant BI-RADS categories that would negatively impact clinical management. © RSNA, 2024 Supplemental material is available for this article.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Estudos Retrospectivos , Neoplasias da Mama/diagnóstico por imagem , Pessoa de Meia-Idade , Sistemas de Informação em Radiologia/estatística & dados numéricos , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Mama/diagnóstico por imagem , Idoso , Adulto , Idioma , Ultrassonografia Mamária/métodos
5.
Clin Imaging ; 110: 110094, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38599926

RESUMO

PURPOSE: In this study, we aimed to assess the new trends in characteristics, molecular subtypes, and imaging findings of breast cancer in very young women. METHODS: We retrospectively reviewed the database of a primary breast cancer referral center in southern Iran in 342 cases of 30-year-old or younger women from 2001 to 2020. Pathologic data, including nuclear subtype and grade, tumor stage, presence of in situ cancer, imaging data including lesion type in mammogram and ultrasound, and treatment data were recorded. Descriptive statistics were applied. Differences between categorical values between groups were compared using Pearson's Chi-square test. RESULTS: The mean age was 27.89 years. The tumor type was invasive ductal carcinoma in 82 % of cases. Fourteen patients (4.4 %) had only in situ cancer, and 170 patients had in situ components (49.7 %). Molecular subtypes were available in 278 patients, including 117 (42.1 %) Luminal A, 64 (23.0 %) Luminal B, 58 (20.9 %) triple negative, and 39 (14 %) HER2 Enriched. In those with mammograms available, 63 (30.1 %) had no findings, 53 (25.3 %) had mass, 27 (12.9 %) had asymmetry, whether focal or global, 21 (10 %) had microcalcifications solely, and 45 (21.5 %) had more than one finding. Microcalcifications were significantly more common in Luminal cancers than HER2 and triple-negative cancers (p = 0.041). CONCLUSION: Our study shows the most common subtype to be Luminal A cancer, with 74 % of the tumors being larger than 2 cm at the time of diagnosis. Irregular masses with non-circumscribed margins were the most common imaging findings.


Assuntos
Neoplasias da Mama , Mamografia , Ultrassonografia Mamária , Humanos , Feminino , Estudos Retrospectivos , Adulto , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Mamografia/métodos , Ultrassonografia Mamária/métodos , Irã (Geográfico)/epidemiologia , Adulto Jovem , Mama/diagnóstico por imagem , Mama/patologia , Estadiamento de Neoplasias
6.
Sci Rep ; 14(1): 7180, 2024 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-38531932

RESUMO

We aimed to investigate the correlation between shear-wave elastography (SWE) and apparent diffusion coefficient (ADC) values in breast cancer and to identify the associated characteristics. We included 91 breast cancer patients who underwent SWE and breast MRI prior to surgery between January 2016 and November 2017. We measured the lesion's mean (Emean) and maximum (Emax) elasticities of SWE and ADC values. We evaluated the correlation between SWE, ADC values and tumor size. The mean SWE and ADC values were compared for categorical variable of the pathological/imaging characteristics. ADC values showed negative correlation with Emean (r = - 0.315, p = 0.002) and Emax (r = - 0.326, p = 0.002). SWE was positively correlated with tumor size (r = 0.343-0.366, p < 0.001). A higher SWE value indicated a tendency towards a higher T stage (p < 0.001). Triple-negative breast cancer showed the highest SWE values (p = 0.02). SWE were significantly higher in breast cancers with posterior enhancement, vascularity, and washout kinetics (p < 0.02). SWE stiffness and ADC values were negatively correlated in breast cancer. SWE values correlated significantly with tumor size, and were higher in triple-negative subtype and aggressive imaging characteristics.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Neoplasias Mamárias Animais , Neoplasias de Mama Triplo Negativas , Humanos , Animais , Feminino , Neoplasias da Mama/patologia , Técnicas de Imagem por Elasticidade/métodos , Mama/patologia , Ultrassonografia Mamária/métodos
7.
Ultrasound Med Biol ; 50(6): 833-842, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38471999

RESUMO

OBJECTIVE: The study described here was aimed at assessing the capability of quantitative ultrasound (QUS) based on the backscatter coefficient (BSC) for classifying disease states, such as breast cancer response to neoadjuvant chemotherapy and quantification of fatty liver disease. We evaluated the effectiveness of an in situ titanium (Ti) bead as a reference target in calibrating the system and mitigating attenuation and transmission loss effects on BSC estimation. METHODS: Traditional BSC estimation methods require external references for calibration, which do not account for ultrasound attenuation or transmission losses through tissues. To address this issue, we used an in situ Ti bead as a reference target, because it can be used to calibrate the system and mitigate the attenuation and transmission loss effects on estimation of the BSC. The capabilities of the in situ calibration approach were assessed by quantifying consistency of BSC estimates from rabbit mammary tumors (N = 21). Specifically, mammary tumors were grown in rabbits and when a tumor reached ≥1 cm in size, a 2 mm Ti bead was implanted in the tumor as a radiological marker and a calibration source for ultrasound. Three days later, the tumors were scanned with an L-14/5 38 array transducer connected to a SonixOne scanner with and without a slab of pork belly placed on top of the tumors. The pork belly acted as an additional source of attenuation and transmission loss. QUS parameters, specifically effective scatterer diameter (ESD) and effective acoustic concentration (EAC), were calculated using calibration spectra from both an external reference phantom and the Ti bead. RESULTS: For ESD estimation, the 95% confidence interval between measurements with and without the pork belly layer was 6.0, 27.4 using the in situ bead and 114, 135.1 with the external reference phantom. For EAC estimation, the 95% confidence intervals were -8.1, 0.5 for the bead and -41.5, -32.2 for the phantom. These results indicate that the in situ bead method has reduced bias in QUS estimates because of intervening tissue losses. CONCLUSION: The use of an in situ Ti bead as a radiological marker not only serves its traditional role but also effectively acts as a calibration target for QUS methods. This approach accounts for attenuation and transmission losses in tissue, resulting in more accurate QUS estimates and offering a promising method for enhanced disease state classification in clinical settings.


Assuntos
Espalhamento de Radiação , Calibragem , Animais , Coelhos , Feminino , Ultrassonografia/métodos , Titânio , Reprodutibilidade dos Testes , Imagens de Fantasmas , Ultrassonografia Mamária/métodos
8.
Eur J Radiol ; 175: 111432, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38554672

RESUMO

PURPOSE: To investigate whether multiparametric parameters of pretreatment breast ultrasound (US) and clinicopathologic factors are associated with pathologic complete response (pCR) after neoadjuvant chemotherapy (NAC) for breast cancer. METHODS: Between November 2018 and September 2022, 88 patients who underwent NAC and subsequent surgery were included in this study (median age, 55 years; interquartile range [IQR], 45, 59.3). Multiparametric breast US including grayscale, shear wave elastography (SWE) and superb microvascular imaging (SMI) of pathologically proven invasive breast cancers were retrospectively reviewed. Clinicopathological and multiparametric parameters of breast US, including size, SWEmax, SWEratio and vascular index on SMI (SMIVI) were compared between the groups. Univariate and multivariate logistic regression analyses were performed to determine factors predicting pCR after NAC. AUROC curve analysis was performed to determine the predictors' optimal cut-off values and diagnostic performance. RESULTS: The pCR group (n = 24) showed a significantly smaller tumor size, lower SWEmax, higher Ki-67 index, higher hormone receptor negativity and negative axillary lymph node metastasis compared to the non-pCR group (n = 64). Multivariate regression analysis showed that SWEmax (adjusted odds ratio[aOR] = 0.956, 95 % confidence interval [CI] = 0.919-0.994, P = 0.025) and Ki-67 index (aOR = 1.083, 95 % CI = 1.012-1.159, P = 0.021) were independently associated with pathologically complete response. The optimal cut-off values for predicting pCR were 27.5 % for Ki-67 with an AUC of 0.743 and 134.8 kPa for SWEmax with an AUC of 0.779. A combination model including clinical factors and SWEmax showed the best diagnostic performance with an AUC of 0.876. CONCLUSION: A higher Ki-67 index and lower SWEmax measured on pretreatment breast US were independently associated with pCR in invasive breast cancer after NAC.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Terapia Neoadjuvante , Ultrassonografia Mamária , Humanos , Técnicas de Imagem por Elasticidade/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Pessoa de Meia-Idade , Feminino , Ultrassonografia Mamária/métodos , Estudos Retrospectivos , Resultado do Tratamento , Invasividade Neoplásica , Valor Preditivo dos Testes , Mama/diagnóstico por imagem , Microvasos/diagnóstico por imagem , Adulto , Quimioterapia Adjuvante
9.
Eur J Radiol ; 175: 111415, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38471320

RESUMO

OBJECTIVE: To investigate the independent risk variables associated with the potential invasiveness of ductal carcinoma in situ (DCIS) on multi-parametric ultrasonography, and further construct a nomogram for risk assessment. METHODS: Consecutive patients from January 2017 to December 2022 who were suspected of having ductal carcinoma in situ (DCIS) based on magnetic resonance imaging or mammography were prospectively enrolled. Histopathological findings after surgical resection served as the gold standard. Grayscale ultrasound, Doppler ultrasound, shear wave elastography (SWE), and contrast-enhanced ultrasound (CEUS) examinations were preoperative performed. Binary logistic regression was used for multifactorial analysis to identify independent risk factors from multi-parametric ultrasonography. The correlation between independent risk factors and pathological prognostic markers was analyzed. The predictive efficacy of DCIS associated with invasiveness was assessed by logistic analysis, and a nomogram was established. RESULTS: A total of 250 DCIS lesions were enrolled from 249 patients, comprising 85 pure DCIS and 165 DCIS with invasion (DCIS-IDC), of which 41 exhibited micro-invasion. The multivariate analysis identified independent risk factors for DCIS with invasion on multi-parametric ultrasonography, including image size (>2cm), Doppler ultrasound RI (≥0.72), SWE's Emax (≥66.4 kPa), hyper-enhancement, centripetal enhancement, increased surrounding vessel, and no contrast agent retention on CEUS. These factors correlated with histological grade, Ki-67, and human epidermal growth factor receptor 2 (HER2) (P < 0.1). The multi-parametric ultrasound approach demonstrated good predictive performance (sensitivity 89.7 %, specificity 73.8 %, AUC 0.903), surpassing single US modality or combinations with SWE or CEUS modalities. Utilizing these factors, a predictive nomogram achieved a respectable performance (AUC of 0.889) for predicting DCIS with invasion. Additionally, a separate nomogram for predicting DCIS with micro-invasion, incorporating independent risk factors such as RI (≥0.72), SWE's Emax (≥65.2 kPa), and centripetal enhancement, demonstrated an AUC of 0.867. CONCLUSION: Multi-parametric ultrasonography demonstrates good discriminatory ability in predicting both DCIS with invasion and micro-invasion through the analysis of lesion morphology, stiffness, neovascular architecture, and perfusion. The use of a nomogram based on ultrasonographic images offers an intuitive and effective method for assessing the risk of invasion in DCIS. Although the nomogram is not currently considered a clinically applicable diagnostic tool due to its AUC being below the threshold of 0.9, further research and development are anticipated to yield positive outcomes and enhance its viability for clinical utilization.


Assuntos
Neoplasias da Mama , Carcinoma Intraductal não Infiltrante , Técnicas de Imagem por Elasticidade , Invasividade Neoplásica , Nomogramas , Ultrassonografia Mamária , Humanos , Feminino , Pessoa de Meia-Idade , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Invasividade Neoplásica/diagnóstico por imagem , Ultrassonografia Mamária/métodos , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/patologia , Idoso , Técnicas de Imagem por Elasticidade/métodos , Adulto , Estudos Prospectivos , Meios de Contraste , Fatores de Risco , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Medição de Risco
10.
Biosensors (Basel) ; 14(2)2024 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-38392013

RESUMO

Breast cancer (BC) affects millions of women worldwide, causing over 500,000 deaths annually. It is the leading cause of cancer mortality in women, with 70% of deaths occurring in developing countries. Elastography, which evaluates tissue stiffness, is a promising real-time minimally invasive technique for BC diagnosis. This study assessed strain elastography (SE) and the fat-to-lesion (F/L) index for BC diagnosis. This prospective study included 216 women who underwent SE, ultrasound, mammography, and breast biopsy (108 malignant, 108 benign). Three expert radiologists performed imaging and biopsies. Mean F/L index was 3.70 ± 2.57 for benign biopsies and 18.10 ± 17.01 for malignant. We developed two predictive models: a logistic regression model with AUC 0.893, 79.63% sensitivity, 87.62% specificity, 86.9% positive predictive value (+PV), and 80.7% negative predictive value (-PV); and a neural network with AUC 0.902, 80.56% sensitivity, 88.57% specificity, 87.9% +PV, and 81.6% -PV. The optimal Youden F/L index cutoff was >5.76, with 84.26% sensitivity and specificity. The F/L index positively correlated with BI-RADS (Spearman's r = 0.073, p < 0.001) and differed among molecular subtypes (Kruskal-Wallis, p = 0.002). SE complements mammography for BC diagnosis. With adequate predictive capacity, SE is fast, minimally invasive, and useful when mammography is contraindicated.


Assuntos
Neoplasias Encefálicas , Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Técnicas de Imagem por Elasticidade/métodos , Estudos Prospectivos , Ultrassonografia Mamária/métodos , Mamografia , Biópsia , Sensibilidade e Especificidade
11.
Eur J Radiol ; 173: 111391, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38422608

RESUMO

PURPOSE: The objective of this study was to investigate the independent risk factors and associated predictive values of contrast-enhanced ultrasound (CEUS), shear wave elastography (SWE), and strain elastography (SE) for high-risk lesions (HRL) and malignant tumors (MT) among nonpalpable breast masses classified as BI-RADS category 4 on conventional ultrasound. METHODS: This prospective study involved consecutively admitted patients with breast tumors from January 2018, aiming to explore the management of BI-RADS category 4 breast tumors using CEUS and elastography. We conducted a retrospective review of patient data, focusing on those with a history of a nonpalpable mass as the primary complaint. Pathologic findings after surgical resection served as the gold standard. The CEUS arterial-phase indices were analyzed using contrast agent arrival-time parametric imaging processing mode, while quantitative and qualitative indices were examined on ES images. Independent risk factors were identified through binary logistic regression multifactorial analysis. The predictive efficacy of different modalities was compared using a receiver operating characteristics curve. Subsequently, a nomogram for predicting the risk of HRL/MT was established based on a multifactorial logistic regression model. RESULTS: A total of 146 breast masses from 146 patients were included, comprising 80 benign tumors, 12 HRLs, and 54 MTs based on the final pathology. There was no significant difference in pathologic size between the benign and HRL/MT groups [8.00(6.25,10.00) vs. 9.00(6.00,10.00), P = 0.506]. The diagnostic efficacy of US plus CEUS exceeded that of US plus SWE/SE for BI-RADS 4 nonpalpable masses, with an AUC of 0.954 compared to 0.798/0.741 (P ï¼œ 0.001). Further stratified analysis revealed a more pronounced improvement for reclassification of BI-RADS 4a masses (AUC: 0.943 vs. 0.762/0.675, P ï¼œ 0.001) than BI-RADS 4b (AUC:0.950 vs. 0.885/0.796, P>0.05) with the assistance of CEUS than SWE/SE. Employing downgrade CEUS strategies resulted in negative predictive values ranging from 95.2 % to 100.0 % for BI-RADS 4a and 4b masses. Conversely, using upgrade nomogram strategies, which included the independent predictive risk factors of irregular enhanced shape, poor defined enhanced margin, earlier enhanced time, increased surrounding vessels, and presence of contrast agent retention, the diagnostic performance achieved an AUC of 0.947 with good calibration. CONCLUSION: After investigating the potential of CEUS and ES in improving risk assessment and diagnostic accuracy for nonpalpable BI-RADS category 4 breast masses, it is evident that CEUS has a more significant impact on enhancing classification compared to ES, particularly for BI-RADS 4a subgroup masses. This finding suggests that CEUS may offer greater benefits in improving risk assessment and diagnostic accuracy for this specific subgroup of breast masses.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Feminino , Humanos , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Mamária/métodos , Estudos Prospectivos , Meios de Contraste , Sensibilidade e Especificidade , Reprodutibilidade dos Testes , Mama/diagnóstico por imagem , Ultrassonografia , Neoplasias da Mama/diagnóstico por imagem
12.
BMC Womens Health ; 24(1): 87, 2024 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-38310239

RESUMO

BACKGROUND: Approximately 50% of breast mucinous carcinomas (MCs) are oval and have the possibility of being misdiagnosed as fibroadenomas (FAs). We aimed to identify the key features that can help differentiate breast MC with an oval shape from FA on ultrasonography (US). METHODS: Seventy-six MCs from 71 consecutive patients and 50 FAs with an oval shape from 50 consecutive patients were included in our study. All lesions pathologically diagnosed. According to the Breast Imaging Reporting and Data System (BI-RADS), first, the ultrasonographic features of the MCs and FAs were recorded and a final category was assessed. Then, the differences in ultrasonographic characteristics between category 4 A (low-risk group) and category 4B-5 (medium-high- risk group) MCs were identified. Finally, other ultrasonographic features of MC and FA both with an oval shape were compared to determine the key factors for differential diagnosis. The Mann-Whitney test, χ2 test or Fisher's exact test was used to compare data between groups. RESULTS: MCs with an oval shape (81.2%) and a circumscribed margin (25%) on US were more commonly assessed in the low-risk group (BI-RADS 4 A) than in the medium-high-risk group (BI-RADS 4B-5) (20%, p < 0.001 and 0%, p = 0.001, respectively). Compared with those with FA, patients with MC were older, and tended to have masses with non-hypoechoic patterns, not circumscribed margins, and a posterior echo enhancement on US (p < 0.001, p < 0.001, and p = 0.003, respectively). CONCLUSION: The oval shape was the main reason for the underestimation of MCs. On US, an oval mass found in the breast of women of older age with non-hypoechoic patterns, not circumscribed margins, and a posterior echo enhancement was associated with an increased risk of being an MC, and should be subjected to active biopsy.


Assuntos
Adenocarcinoma Mucinoso , Neoplasias da Mama , Fibroadenoma , Feminino , Humanos , Diagnóstico Diferencial , Fibroadenoma/diagnóstico , Ultrassonografia Mamária/métodos , Neoplasias da Mama/diagnóstico , Adenocarcinoma Mucinoso/diagnóstico por imagem , Estudos Retrospectivos
13.
Zhonghua Wai Ke Za Zhi ; 62(2): 135-140, 2024 Feb 01.
Artigo em Chinês | MEDLINE | ID: mdl-38310381

RESUMO

Objectives: To examine the clinicopathological characteristics and the influencing factors of the residual tumor of patients with Breast Image Report and Data System (BI-RADS) grade 3 lesions diagnosed with malignancy after minimally invasive excision. Methods: In this retrospective case-control study, clinicopathological data of 69 cases, which had been evaluated as BI-RADS 3 lesions by ultrasound (4 151 cases) diagnosed with breast cancer by minimally invasive excision pathology, were analyzed between May 2012 and June 2016 at the Department of Breast Surgery of the Second Hospital of Shandong University and Linyi People's Hospital. All patients were female, aged (43.4±8.2) years (range: 22 to 70 years). Based on residual tumor after minimally invasive excision, patients were classified into two subgroups: tumor residual group (n=39) and non-tumor residual group (n=30). The clinicopathological features between the two groups were compared. The differences in clinicopathological characteristics were compared in different groups using the χ2 test and the t test. Potential variables identified in the univariate analysis and other relevant variables will be analyzed multivarially using Logistic regression models. The Kaplan-Meier method was applied for survival analysis and survival curves. Results: The breast cancer detection rate of ultrasound BI-RADS 3 lesions was 1.66% (69/4 151), and their maximum diameter of the masses was (1.27±0.45) cm (range: 0.5 to 2.3 cm). Among them, the maximum diameter were ≤1 cm in 28 cases and >1 cm in 41 cases. Histopathological results showed carcinoma in situ in 24 cases and invasive carcinoma in 41 cases, positive expression of the estrogen receptor in 47 cases, positive expression of the progesterone receptor in 43 cases, Ki-67 proliferation index elevated in 26 cases. Axillary metastasis positive rate was 10.1% (7/69). Residual tumor after minimally invasive surgery was found in 39 cases (56.5%). Univariate analysis showed that the tumour residual group showed a significantly increased rate of positive expression of the estrogen receptor (91.9%(34/37) vs. 61.9%(13/21), χ2=7.838, P=0.012). In multivariate analysis, the only variable found to significantly affect the residual tumor was the positive expression of the estrogen receptor (OR=16.852, 95%CI: 1.819 to 156.130, P=0.013). The 5-year disease-free survival rate of breast cancer patients with breast ultrasound BI-RADS 3 lesions was 97.1% and the overall survival rate was 98.6%. Conclusions: BI-RADS 3 lesions diagnosed by ultrasound undergoing ultrasound-guided minimally invasive excision have a certain risk of detected malignancy, approximately 1.66%. Patients with positive expression of the estrogen receptor are more likely to develop residual tumor. A secondary operation should be considered to ensure that no tumor residues remain in the cavity.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Masculino , Neoplasias da Mama/patologia , Estudos Retrospectivos , Estudos de Casos e Controles , Neoplasia Residual , Ultrassonografia Mamária/métodos , Receptores de Estrogênio
14.
Sci Rep ; 14(1): 4578, 2024 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-38403659

RESUMO

The aim of this study was to quantify the orientation of breast masses and determine whether it can enhance the utility of a not parallel orientation in predicting breast mass malignancy. A total of 15,746 subjects who underwent breast ultrasound examinations were initially enrolled in the study. Further evaluation was performed on subjects with solid breast masses (≤ 5 cm) intended for surgical resection and/or biopsy. The orientation angle, defined as the acute angle between the align of the maximal longitudinal diameter of the breast mass and the surface of the breast skin, was measured. Receiver operating characteristic (ROC) curve analysis was conducted, and various performance measures including sensitivity, specificity, positive and negative predictive values, accuracy, odds ratio, and the area under the ROC curve (AUC) were calculated. Multivariate analysis was performed to determine if the orientation angle was an independent predictor of breast malignancy. Decision curve analysis (DCA) was also conducted to assess the net benefit of adopting the orientation angle for predicting breast mass malignancy. The final analysis included 83 subjects with breast cancer and 135 subjects with benign masses. The intra-group correlation coefficient for the measurement of the orientation angle of breast masses was 0.986 (P = 0.001), indicating high reproducibility. The orientation angles of malignant and benign breast masses were 36.51 ± 14.90 (range: 10.7-88.6) degrees and 15.28 ± 8.40 (range: 0.0-58.7) degrees, respectively, and there was a significant difference between them (P < 0.001). The cutoff value for the orientation angle was determined to be 22.9°. The sensitivity, specificity, positive and negative predictive values, accuracy, odds ratio, and AUC for the prediction of breast malignancy using the orientation angle were 88.0%, 87.4%, 81.1%, 92.2%, 87.6%, 50.67%, and 0.925%, respectively. Multivariate analysis revealed that the orientation angle (> 22.9°), not circumscribed margin, and calcifications of the breast mass were independent factors predicting breast malignancy. The net benefit of adopting the orientation angle for predicting breast malignancy was 0.303. Based on these findings, it can be concluded that quantifying the orientation angle of breast masses is useful in predicting breast malignancy, as it demonstrates high sensitivity, specificity, AUC, and standardized net benefit. It optimizes the utility of the not parallel orientation in assessing breast mass malignancy.


Assuntos
Neoplasias da Mama , Mama , Feminino , Humanos , Reprodutibilidade dos Testes , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Ultrassonografia Mamária/métodos , Sensibilidade e Especificidade
15.
J Ultrasound Med ; 43(6): 1013-1024, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38323467

RESUMO

OBJECTIVES: The coronal plane is the unique display mode of automated breast (AB) ultrasound (US), which has valuable features of showing the entire breast anatomy and providing additional diagnostic value for breast lesions. However, whether adding the coronal plane could improve the diagnostic performance in screening breast cancer remains uncertain. This study aimed to evaluate the value of adding the coronal plane in interpretation for AB US screening. METHODS: In this retrospective study, AB US images from 644 women (396 in the no-finding group, 143 with benign lesions, and 105 with malignant lesions) aged 40-70 years were collected between January 2016 and October 2020. Four novice radiologists (with 1-5 years of experience with breast US) and four experienced radiologists (with >5 years of experience with breast US) were assigned to read all AB US images in the transverse plane plus coronal plane (T + C planes) and transverse plane (T plane) alone in separate reading sessions. Diagnostic performance, lesion conspicuity, and reading time were compared using analysis of variance. RESULTS: The mean reading time of all radiologists was significantly shorter in the T + C planes reading mode than in the T plane alone (115 ± 32 vs 128 ± 31 s, respectively; P < .05), and cancers had a higher conspicuity (odds ratio, 1.76; 95% confidence interval [CI], 1.00-3.08; P = .04). No significant differences were noted in the two reading modes (T + C planes vs T plane) in the sensitivity (82% [95% CI, 74-89%] vs 81% [95% CI, 74-88%], respectively; P = .68) and specificity (68% [95% CI, 62-75%] vs 70% [95% CI, 64-75%], respectively; P = .39) when Breast Imaging-Reporting and Data System (BI-RADS) 3 was set as the threshold. There were also no significant differences in the two reading modes (T + C planes vs T plane) in the sensitivity (70% [95% CI, 64-76%] vs 69% [95% CI, 63-75%], respectively; P = .39) and specificity (91% [95% CI, 87-96%] vs 91% [95% CI, 88-95%], respectively; P = .90) when BI-RADS 4 was set as the threshold. In addition, the mean areas under the receiver operating characteristic curves of all radiologists in the two reading modes (T + C planes vs T plane) were not significantly different (0.84 [95% CI, 0.79-0.89] vs 0.83 [95% CI, 0.78-0.89], respectively; P = .61). CONCLUSIONS: Adding a coronal plane in the AB US screening setting saved the reading time and improved the conspicuity of breast cancers but not the diagnostic performance.


Assuntos
Neoplasias da Mama , Mama , Sensibilidade e Especificidade , Ultrassonografia Mamária , Humanos , Feminino , Pessoa de Meia-Idade , Ultrassonografia Mamária/métodos , Estudos Retrospectivos , Neoplasias da Mama/diagnóstico por imagem , Idoso , Adulto , Mama/diagnóstico por imagem , Reprodutibilidade dos Testes
16.
J Womens Health (Larchmt) ; 33(4): 499-501, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38386779

RESUMO

Background: Owing to its high sensitivity, as concluded in the Breast UltraSound Trial (BUST), targeted ultrasound (US) now seems a promising accurate stand-alone modality for diagnostic evaluation of breast complaints. This approach implies omission of bilateral digital breast tomosynthesis (DBT) in women with clearly benign US findings. Within BUST, radiologists started with US followed by DBT. This side-study investigates women's experiences with DBT, their main motivation to undergo diagnostic imaging, and their view on US as a stand-alone modality. Methods: A subset of BUST participants completed a questionnaire on their DBT experiences, reason for undergoing diagnostic assessment, and view on US-only diagnostics. Responses were analyzed with descriptive statistics and logistic regression analyses. Results: In total, 778 of 838 women (response rate 92.8%) were included (M = 47, SD = 11.16). Of them, 16.8% reported no burden of DBT, 33.5% slight burden, 31.0% moderate, and 12.7% severe burden. Furthermore, 13% reported no pain, 35.3% slight pain, 33.2% moderate, and 11.3% severe pain. Moreover, 88.3% indicated that the most important reason for breast assessment was explanation of their complaint and to rule out breast cancer, whereas 3.2% wanted to "check" both breasts. And 82.4% reported satisfaction with US only in case of a nonmalignancy. Conclusions: Our study shows that most women in the diagnostic setting experience at least slight-to-moderate DBT-related burden and pain, and that explanation for their symptoms is their main interest. Also, the majority report satisfaction with US only in case of nonmalignant findings. However, exploration of women's perspectives outside this study is needed as our participants all underwent both examinations.


Assuntos
Neoplasias da Mama , Mamografia , Ultrassonografia Mamária , Humanos , Feminino , Pessoa de Meia-Idade , Adulto , Ultrassonografia Mamária/métodos , Inquéritos e Questionários , Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Satisfação do Paciente/estatística & dados numéricos , Idoso
18.
Ultrasound Med Biol ; 50(4): 474-483, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38195266

RESUMO

OBJECTIVE: Despite recent improvements in medical imaging, the final diagnosis and biopathologic characterization of breast cancers currently still requires biopsies. Ultrasound is commonly used for clinical examination of breast masses. B-Mode and shear wave elastography (SWE) are already widely used to detect suspicious masses and differentiate benign lesions from cancers. But additional ultrasound modalities such as backscatter tensor imaging (BTI) could provide relevant biomarkers related to tissue organization. Here we describe a 3-D multiparametric ultrasound approach applied to breast carcinomas in the aims of (i) validating the ability of BTI to reveal the underlying organization of collagen fibers and (ii) assessing the complementarity of SWE and BTI to reveal biopathologic features of diagnostic interest. METHODS: Three-dimensional SWE and BTI were performed ex vivo on 64 human breast carcinoma samples using a linear ultrasound probe moved by a set of motors. Here we describe a 3-D multiparametric representation of the breast masses and quantitative measurements combining B-mode, SWE and BTI. RESULTS: Our results reveal for the first time that BTI can capture the orientation of the collagen fibers around tumors. BTI was found to be a relevant marker for assessing cancer stages, revealing a more tangent tissue orientation for in situ carcinomas than for invasive cancers. In invasive cases, the combination of BTI and SWE parameters allowed for classification of invasive tumors with respect to their grade with an accuracy of 95.7%. CONCLUSION: Our results highlight the potential of 3-D multiparametric ultrasound imaging for biopathologic characterization of breast tumors.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Feminino , Humanos , Neoplasias da Mama/patologia , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Mamária/métodos , Abordagem GRADE , Mama/diagnóstico por imagem , Mama/patologia , Colágeno , Sensibilidade e Especificidade , Reprodutibilidade dos Testes , Diagnóstico Diferencial
19.
Postgrad Med J ; 100(1183): 309-318, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38275274

RESUMO

BACKGROUND: The application of photoacoustic imaging (PAI), utilizing laser-induced ultrasound, shows potential in assessing blood oxygenation in breast nodules. However, its effectiveness in distinguishing between malignant and benign nodules remains insufficiently explored. PURPOSE: This study aims to develop nomogram models for predicting the benign or malignant nature of breast nodules using PAI. METHOD: A prospective cohort study enrolled 369 breast nodules, subjecting them to PAI and ultrasound examination. The training and testing cohorts were randomly divided into two cohorts in a ratio of 3:1. Based on the source of the variables, three models were developed, Model 1: photoacoustic-BIRADS+BMI + blood oxygenation, Model 2: BIRADS+Shape+Intranodal blood (Doppler) + BMI, Model 3: photoacoustic-BIRADS+BIRADS+ Shape+Intranodal blood (Doppler) + BMI + blood oxygenation. Risk factors were identified through logistic regression, resulting in the creation of three predictive models. These models were evaluated using calibration curves, subject receiver operating characteristic (ROC), and decision curve analysis. RESULTS: The area under the ROC curve for the training cohort was 0.91 (95% confidence interval, 95% CI: 0.88-0.95), 0.92 (95% CI: 0.89-0.95), and 0.97 (95% CI: 0.96-0.99) for Models 1-3, and the ROC curve for the testing cohort was 0.95 (95% CI: 0.91-0.98), 0.89 (95% CI: 0.83-0.96), and 0.97 (95% CI: 0.95-0.99) for Models 1-3. CONCLUSIONS: The calibration curves demonstrate that the model's predictions agree with the actual values. Decision curve analysis suggests a good clinical application.


Assuntos
Neoplasias da Mama , Nomogramas , Técnicas Fotoacústicas , Humanos , Feminino , Técnicas Fotoacústicas/métodos , Neoplasias da Mama/diagnóstico por imagem , Estudos Prospectivos , Pessoa de Meia-Idade , Adulto , Ultrassonografia Mamária/métodos , Curva ROC , Idoso , Valor Preditivo dos Testes , Diagnóstico Diferencial
20.
J Epidemiol Glob Health ; 14(1): 63-71, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38206550

RESUMO

BACKGROUND AND AIM: Breast cancer is the most frequently occurring malignant disease in women and remains the leading cause of cancer-related deaths among females worldwide. The aim of this study is to evaluate the imaging findings of breast cancer in women under the age of 40 and analyze their pathological patterns. METHOD: A retrospective study was conducted from 2013 to 2019, involving 120 patients below 40 years of age with pathologically confirmed primary epithelial breast cancers. The data were collected from the electronic records of a tertiary hospital in Riyadh, Saudi Arabia. Mammograms were performed for 115 patients, ultrasounds were conducted for all patients, and MRI scans were carried out for 47 patients. RESULTS: All radiological findings and clinical characteristics of the 120 cases were retrieved from our digital-based system. The majority of breast cancer patients (83.4%) were between 30 and 40 years old, and the most common clinical presentation was a mass (45.8%). Out of the 73 patients who underwent genetic tests, 32.9% tested positive for gene mutations. No statistically significant correlation was found between specific age groups and breast composition (P = 0.216), specific mammogram abnormalities such as masses (P = 0.262), or microcalcifications (P = 0.421). Ultrasonography was performed for all patients, with abnormalities detected in only one patient who was diagnosed with Paget's disease of the nipple. Masses, with or without parenchymal changes, were the predominant feature in 88.3% of cases. CONCLUSION: The imaging findings in breast cancer cases typically involve masses with suspicious features, irregular shape, and spiculated margins on mammograms, and irregular shape with microlobulated or angular margins on ultrasound. MRI features commonly include masses with irregular shape and heterogeneous enhancement. The luminal B subtype was identified as the most prevalent pathological feature, characterized by a high proliferative index (Ki-67%).


Assuntos
Neoplasias da Mama , Imageamento por Ressonância Magnética , Mamografia , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/epidemiologia , Adulto , Estudos Retrospectivos , Arábia Saudita/epidemiologia , Mamografia/métodos , Imageamento por Ressonância Magnética/métodos , Ultrassonografia Mamária/métodos , Adulto Jovem , Estudos de Coortes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA