Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.090
Filtrar
1.
Early Hum Dev ; 193: 106021, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38701668

RESUMO

OBJECTIVE: Fetal face measurements in prenatal ultrasound can aid in identifying craniofacial abnormalities in the developing fetus. However, the accuracy and reliability of ultrasound measurements can be affected by factors such as fetal position, image quality, and the sonographer's expertise. This study assesses the accuracy and reliability of fetal facial measurements in prenatal ultrasound. Additionally, the temporal evolution of measurements is studied, comparing prenatal and postnatal measurements. METHODS: Three different experts located up to 23 facial landmarks in 49 prenatal 3D ultrasound scans from normal Caucasian fetuses at weeks 20, 26, and 35 of gestation. Intra- and inter-observer variability was obtained. Postnatal facial measurements were also obtained at 15 days and 1 month postpartum. RESULTS: Most facial landmarks exhibited low errors, with overall intra- and inter-observer errors of 1.01 mm and 1.60 mm, respectively. Landmarks on the nose were found to be the most reliable, while the most challenging ones were those located on the ears and eyes. Overall, scans obtained at 26 weeks of gestation presented the best trade-off between observer variability and landmark visibility. The temporal evolution of the measurements revealed that the lower face area had the highest rate of growth throughout the latest stages of pregnancy. CONCLUSIONS: Craniofacial landmarks can be evaluated using 3D fetal ultrasound, especially those located on the nose, mouth, and chin. Despite its limitations, this study provides valuable insights into prenatal and postnatal biometric changes over time, which could aid in developing predictive models for postnatal measurements based on prenatal data.


Assuntos
Face , Ultrassonografia Pré-Natal , Humanos , Feminino , Ultrassonografia Pré-Natal/métodos , Ultrassonografia Pré-Natal/normas , Face/diagnóstico por imagem , Face/embriologia , Face/anatomia & histologia , Gravidez , Imageamento Tridimensional/métodos , Estudos Longitudinais , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Adulto
3.
Int J Gynaecol Obstet ; 165(3): 1013-1021, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38189177

RESUMO

OBJECTIVE: Low-cost devices have made obstetric sonography possible in settings where it was previously unfeasible, but ensuring quality and consistency at scale remains a challenge. In the present study, we sought to create a tool to reduce substandard fetal biometry measurement while minimizing care disruption. METHODS: We developed a deep learning artificial intelligence (AI) model to estimate gestational age (GA) in the second and third trimester from fly-to cineloops-brief videos acquired during routine ultrasound biometry-and evaluated its performance in comparison to expert sonographer measurement. We then introduced random error into fetal biometry measurements and analyzed the ability of the AI model to flag grossly inaccurate measurements such as those that might be obtained by a novice. RESULTS: The mean absolute error (MAE) of our model (±standard error) was 3.87 ± 0.07 days, compared to 4.80 ± 0.10 days for expert biometry (difference -0.92 days; 95% CI: -1.10 to -0.76). Based on simulated novice biometry with average absolute error of 7.5%, our model reliably detected cases where novice biometry differed from expert biometry by 10 days or more, with an area under the receiver operating characteristics curve of 0.93 (95% CI: 0.92, 0.95), sensitivity of 81.0% (95% CI: 77.9, 83.8), and specificity of 89.9% (95% CI: 88.1, 91.5). These results held across a range of sensitivity analyses, including where the model was provided suboptimal truncated fly-to cineloops. CONCLUSIONS: Our AI model estimated GA more accurately than expert biometry. Because fly-to cineloop videos can be obtained without any change to sonographer workflow, the model represents a no-cost guardrail that could be incorporated into both low-cost and commercial ultrasound devices to prevent reporting of most gross GA estimation errors.


Assuntos
Aprendizado Profundo , Idade Gestacional , Ultrassonografia Pré-Natal , Humanos , Ultrassonografia Pré-Natal/normas , Ultrassonografia Pré-Natal/métodos , Gravidez , Feminino , Controle de Qualidade , Gravação em Vídeo , Biometria/métodos , Terceiro Trimestre da Gravidez , Segundo Trimestre da Gravidez
4.
Rev. chil. obstet. ginecol. (En línea) ; 88(3): 183-190, jun. 2023. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1515208

RESUMO

La Sociedad Chilena de Obstetricia y Ginecología (SOCHOG) y la Sociedad Chilena de Ultrasonido en Medicina y Biología (SOCHUMB) convocaron a un comité de expertos en el tema de ultrasonido y crecimiento fetal con el fin de proponer utilizar la curva fetal que mejor se adapte a la población chilena. Luego de la discusión, al no contar con curvas chilenas de crecimiento fetal, se concluye proponer que la curva estándar de la Organización Mundial de la Salud (OMS) sería la indicada dada la calidad de su metodología y por ser multicéntrica.


The Chilean Society of Obstetrics and Gynecology (SOCHOG) and the Chilean Society of Ultrasound in Medicine and Biology (SOCHUMB) have convened a committee of experts on the subject of ultrasound and fetal growth in order to propose using the fetal curve that best adapts to the Chilean population. After the discussion, since there are no Chilean fetal growth curves, it is concluded that the World Health Organization (WHO) standard curve would be the one to use given the quality of its methodology and the fact that it is multicentric.


Assuntos
Humanos , Feminino , Gravidez , Organização Mundial da Saúde , Ultrassonografia Pré-Natal/normas , Padrões de Referência , Chile , Peso Fetal , Consenso
6.
Prenat Diagn ; 42(1): 49-59, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34648206

RESUMO

OBJECTIVE: Advances in artificial intelligence (AI) have demonstrated potential to improve medical diagnosis. We piloted the end-to-end automation of the mid-trimester screening ultrasound scan using AI-enabled tools. METHODS: A prospective method comparison study was conducted. Participants had both standard and AI-assisted US scans performed. The AI tools automated image acquisition, biometric measurement, and report production. A feedback survey captured the sonographers' perceptions of scanning. RESULTS: Twenty-three subjects were studied. The average time saving per scan was 7.62 min (34.7%) with the AI-assisted method (p < 0.0001). There was no difference in reporting time. There were no clinically significant differences in biometric measurements between the two methods. The AI tools saved a satisfactory view in 93% of the cases (four core views only), and 73% for the full 13 views, compared to 98% for both using the manual scan. Survey responses suggest that the AI tools helped sonographers to concentrate on image interpretation by removing disruptive tasks. CONCLUSION: Separating freehand scanning from image capture and measurement resulted in a faster scan and altered workflow. Removing repetitive tasks may allow more attention to be directed identifying fetal malformation. Further work is required to improve the image plane detection algorithm for use in real time.


Assuntos
Inteligência Artificial/normas , Anormalidades Congênitas/diagnóstico , Ultrassonografia Pré-Natal/instrumentação , Adulto , Inteligência Artificial/tendências , Anormalidades Congênitas/diagnóstico por imagem , Feminino , Idade Gestacional , Humanos , Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia Pré-Natal/métodos , Ultrassonografia Pré-Natal/normas
7.
Am J Perinatol ; 39(2): 113-119, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34808687

RESUMO

OBJECTIVE: To determine the accuracy and reliability of remotely directed and interpreted ultrasound (teleultrasound) as compared with standard in-person ultrasound for the detection of fetal anomalies, and to determine participants' satisfaction with teleultrasound. STUDY DESIGN: This was a single-center, randomized (1:1) noninferiority study. Individuals referred to the maternal-fetal medicine (MFM) ultrasound clinic were randomized to standard in-person ultrasound and counseling or teleultrasound and telemedicine counseling. The primary outcome was major fetal anomaly detection rate (sensitivity). All ultrasounds were performed by registered diagnostic medical sonographers and interpretations were done by a group of five MFM physicians. After teleultrasound was completed, the teleultrasound patients filled out a satisfaction survey using a Likert scale. Newborn data were obtained from the newborn record and statewide birth defect databases. RESULTS: Of 300 individuals randomized in each group, 294 were analyzed in the remotely interpreted teleultrasound group and 291 were analyzed in the in-person ultrasound group. The sensitivity of sonographic detection of 28 anomalies was 82.14% in the control group and of 20 anomalies in the telemedicine group, it was 85.0%. The observed difference in sensitivity was 0.0286, much smaller than the proposed noninferiority limit of 0.05. Specificity, negative predictive value, positive predictive value, and accuracy were more than 94% for both groups. Patient satisfaction was more than 95% on all measures, and there were no significant differences in patient satisfaction based on maternal characteristics. CONCLUSION: Teleultrasound is not inferior to standard in-person ultrasound for the detection of fetal anomalies. Teleultrasound was uniformly well received by patients, regardless of demographics. These key findings support the continued expansion of telemedicine services. KEY POINTS: · For detection of major anomalies, teleultrasound is comparable to standard ultrasound.. · Teleultrasound was well accepted by patients.. · Teleultrasound use should be expanded..


Assuntos
Anormalidades Congênitas/diagnóstico por imagem , Anormalidades Congênitas/embriologia , Telemedicina/métodos , Ultrassonografia Pré-Natal/métodos , Adulto , Feminino , Humanos , Gravidez , Diagnóstico Pré-Natal , Reprodutibilidade dos Testes , Telemedicina/normas , Ultrassonografia Pré-Natal/normas , Adulto Jovem
8.
Pan Afr Med J ; 40: 35, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34795816

RESUMO

INTRODUCTION: the use of ultrasound is one of the most vital tools in the management of pregnancies and contributes significantly in improving maternal and child health. Certain indications in pregnancy, guide the obstetrician as to which obstetric scan deems appropriate. The full realization of the benefits of ultrasound depends on whether it is being used appropriately or not, and hence this study aimed at auditing for the appropriate indications for obstetric ultrasound. METHODS: a review of all request forms for obstetric scan between June 2019 and July 2020 was performed to assess the appropriateness of requests for obstetric ultrasound at the Cape Coast Teaching Hospital. The data obtained was analyzed using SPSS (SPSS Inc. Chicago, IL version 20.0). A Chi-squared test of independence was used to check for statistically significant differences between variables at p ≤ 0.05. RESULTS: three hundred and fourteen (314) out of the 527 request forms had clinical indications stated. 174 (81.7%) of requests from Cape Coast Teaching Hospital and 39 (18.3%) from other health centers did not indicate patients clinical history/indication on the request forms. Majority 76 (68.5%) of scans in the first trimester were done without indications/history. Only 29 of requests with clinical history were inappropriate. CONCLUSION: practitioners should be mindful of adequately completing request forms for obstetric investigations since a large number of practitioners do not state the history/indications for the scans. There should be continuous medical education on the importance of appropriate indication for obstetric ultrasound.


Assuntos
Obstetrícia/métodos , Padrões de Prática Médica/estatística & dados numéricos , Ultrassonografia Pré-Natal/estatística & dados numéricos , Adolescente , Adulto , Feminino , Gana , Hospitais de Ensino , Humanos , Auditoria Médica , Pessoa de Meia-Idade , Obstetrícia/normas , Padrões de Prática Médica/normas , Gravidez , Estudos Retrospectivos , Centros de Atenção Terciária , Ultrassonografia Pré-Natal/normas , Adulto Jovem
9.
Obstet Gynecol ; 138(4): 593-602, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34352810

RESUMO

OBJECTIVE: To describe MiPATH (the Michigan Plan for Appropriate Tailored Healthcare in pregnancy) panel process and key recommendations for prenatal care delivery. METHODS: We conducted an appropriateness study using the RAND Corporation and University of California Los Angeles Appropriateness Method, a modified e-Delphi process, to develop MiPATH recommendations using sequential steps: 1) definition and scope of key terms, 2) literature review and data synthesis, 3) case scenario development, 4) panel selection and scenario revisions, and 5) two rounds of panel appropriateness ratings with deliberation. Recommendations were developed for average-risk pregnant individuals (eg, individuals not requiring care by maternal-fetal medicine specialists). Because prenatal services (eg, laboratory tests, vaccinations) have robust evidence, panelists considered only how services are delivered (eg, visit frequency, telemedicine). RESULTS: The appropriateness of key aspects of prenatal care delivery across individuals with and without common medical and pregnancy complications, as well as social and structural determinants of health, was determined by the panel. Panelists agreed that a risk assessment for medical, social, and structural determinants of health should be completed as soon as individuals present for care. Additionally, the panel provided recommendations for: 1) prenatal visit schedules (care initiation, visit timing and frequency, routine pregnancy assessments), 2) integration of telemedicine (virtual visits and home devices), and 3) care individualization. Panelists recognized significant gaps in existing evidence and the need for policy changes to support equitable care with changing practices. CONCLUSION: The MiPATH recommendations offer more flexible prenatal care delivery for average-risk individuals.


Assuntos
Atenção à Saúde/normas , Cuidado Pré-Natal/normas , Atenção à Saúde/métodos , Técnica Delphi , Feminino , Humanos , Recém-Nascido , Michigan , Gravidez , Complicações na Gravidez/epidemiologia , Cuidado Pré-Natal/métodos , Medição de Risco , Fatores de Risco , Determinantes Sociais da Saúde/normas , Telemedicina/normas , Ultrassonografia Pré-Natal/normas
12.
Prenat Diagn ; 41(9): 1039-1048, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34318486

RESUMO

BACKGROUND: Lower urinary tract obstruction (LUTO) is a rare but critical fetal diagnosis. Different ultrasound markers have been reported with varying sensitivity and specificity. AIMS: The objective of this systematic review and meta-analysis was to identify the diagnostic accuracy of ultrasound markers for LUTO. MATERIALS AND METHODS: We performed a systematic literature review of studies reporting on fetuses with hydronephrosis or a prenatally suspected and/or postnatally confirmed diagnosis of LUTO. Bayesian bivariate random effects meta-analytic models were fitted, and we calculated posterior means and 95% credible intervals for the pooled diagnostic odds ratio (DOR). RESULTS: A total of 36,189 studies were identified; 636 studies were available for full text review and a total of 42 studies were included in the Bayesian meta-analysis. Among the ultrasound signs assessed, megacystis (DOR 49.15, [15.28, 177.44]), bilateral hydroureteronephrosis (DOR 41.33, [13.36,164.83]), bladder thickening (DOR 13.73, [1.23, 115.20]), bilateral hydronephrosis (DOR 8.36 [3.17, 21.91]), male sex (DOR 8.08 [3.05, 22.82]), oligo- or anhydramnios (DOR 7.75 [4.23, 14.46]), and urinoma (DOR 7.47 [1.14, 33.18]) were found to be predictive of LUTO (Table 1). The predictive sensitivities and specificities however are low and wide study heterogeneity existed. DISCUSSION: Classically, LUTO is suspected in the presence of prenatally detected megacystis with a dilated posterior urethra (i.e., the keyhole sign), and bilateral hydroureteronephrosis. However, keyhole sign has been found to have modest diagnostic performance in predicting the presence of LUTO in the literature which we confirmed in our analysis. The surprisingly low specificity may be influenced by several factors, including the degree of obstruction, and the diligence of the sonographer at searching for and documenting it during the scan. As a result, providers should consider this when establishing the differential for a fetus with hydronephrosis as the presence or absence of keyhole sign does not reliably rule in or rule out LUTO. CONCLUSIONS: Megacystis, bilateral hydroureteronephrosis and bladder wall thickening are the most accurate predictors of LUTO. Given the significant consequences of a missed LUTO diagnosis, clinicians providing counselling for prenatal hydronephrosis should maintain a low threshold for considering LUTO as part of the differential diagnosis.


Assuntos
Ultrassonografia Pré-Natal/normas , Obstrução Uretral/diagnóstico por imagem , Adulto , Teorema de Bayes , Feminino , Idade Gestacional , Humanos , Gravidez , Ultrassonografia Pré-Natal/métodos , Uretra/anormalidades , Uretra/diagnóstico por imagem
13.
Sci Rep ; 11(1): 12464, 2021 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-34127756

RESUMO

Fetal growth restriction is a strong risk factor for perinatal morbidity and mortality. Reliable standards are indispensable, both to assess fetal growth and to evaluate birthweight and early postnatal growth in infants born preterm. The aim of this study was to create updated Swedish reference ranges for estimated fetal weight (EFW) from gestational week 12-42. This prospective longitudinal multicentre study included 583 women without known conditions causing aberrant fetal growth. Each woman was assigned a randomly selected protocol of five ultrasound scans from gestational week 12 + 3 to 41 + 6. Hadlock's 3rd formula was used to estimate fetal weight. A two-level hierarchical regression model was employed to calculate the expected median and variance, expressed in standard deviations and percentiles, for EFW. EFW was higher for males than females. The reference ranges were compared with the presently used Swedish, and international reference ranges. Our reference ranges had higher EFW than the presently used Swedish reference ranges from gestational week 33, and higher median, 2.5th and 97.5th percentiles from gestational week 24 compared with INTERGROWTH-21st. The new reference ranges can be used both for assessment of intrauterine fetal weight and growth, and early postnatal growth in children born preterm.


Assuntos
Desenvolvimento Fetal , Retardo do Crescimento Fetal/diagnóstico , Peso Fetal/fisiologia , Recém-Nascido Prematuro/crescimento & desenvolvimento , Adulto , Peso ao Nascer , Feminino , Retardo do Crescimento Fetal/fisiopatologia , Feto/diagnóstico por imagem , Idade Gestacional , Humanos , Recém-Nascido , Estudos Longitudinais , Masculino , Idade Materna , Gravidez , Trimestres da Gravidez/fisiologia , Estudos Prospectivos , Valores de Referência , Suécia , Ultrassonografia Pré-Natal/normas , Ultrassonografia Pré-Natal/estatística & dados numéricos , Adulto Jovem
14.
Prenat Diagn ; 41(11): 1401-1413, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34091931

RESUMO

OBJECTIVE: To investigate the genetic etiology of skeletal dysplasia in highly selected fetuses during the first and second trimesters using deep phenotyping and exome sequencing (ES). METHOD: Fetuses with short femurs were identified using the established prenatal diagnostic approach. A multidisciplinary team reviewed fetal phenotypic information (prenatal ultrasound findings, fetal postmortem, and radiographs) in a cohort of highly selected fetuses with skeletal dysplasia during the first and second trimesters. The affected families underwent multiplatform genetic tests. RESULTS: Of the 27 affected fetuses, 21 (77.8%) had pathogenic or potential pathogenic variations in the following genes: COL1A1, FGFR3, COL2A1, COL1A2, FLNB, DYNC2LI1, and TRIP11. Two fetuses had compound heterozygous mutations in DYNC2LI1 and TRIP11, respectively, and the other 19 carried de novo autosomal dominant variants. Novel variants were identified in COL1A1, COL2A1, COL1A2, DYNC2LI1, and TRIP11 in 11 fetuses. We also included the first description of the phenotype of odontochondrodysplasia in a prenatal setting. CONCLUSIONS: ES or panel sequencing offers a high diagnostic yield for fetal skeletal dysplasia during the first and second trimesters. Comprehensive and complete phenotypic information is indispensable for genetic analysis and the expansion of genotype-phenotype correlations in fetal skeletal abnormalities.


Assuntos
Dentinogênese Imperfeita/diagnóstico , Sequenciamento do Exoma/normas , Osteocondrodisplasias/diagnóstico , Fenótipo , Adulto , Dentinogênese Imperfeita/genética , Feminino , Feto , Idade Gestacional , Humanos , Osteocondrodisplasias/genética , Gravidez , Primeiro Trimestre da Gravidez/genética , Segundo Trimestre da Gravidez/genética , Ultrassonografia Pré-Natal/métodos , Ultrassonografia Pré-Natal/normas , Ultrassonografia Pré-Natal/estatística & dados numéricos , Sequenciamento do Exoma/métodos , Sequenciamento do Exoma/estatística & dados numéricos
17.
Genes (Basel) ; 12(5)2021 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-33946859

RESUMO

In families without a Cystic Fibrosis (CF) history, fetal ultrasound bowel abnormalities can unexpectedly reveal the disease. Isolated or in association, the signs can be fetal bowel hyperechogenicity, intestinal loop dilatation and non-visualization of fetal gallbladder. In these cases, search for CF transmembrane conductance regulator (CFTR) gene mutations is part of the recommended diagnostic practices, with a search for frequent mutations according to ethnicity, and, in case of the triad of signs, with an exhaustive study of the gene. However, the molecular diagnosis remains a challenge in populations without well-known frequent pathogenic variants. We present a multiethnic cohort of 108 pregnancies with fetal bowel abnormalities in which the parents benefited from an exhaustive study of the CFTR gene. We describe the new homozygous p.Cys1410* mutation in a fetus of African origin. We did not observe the most frequent p.Phe508del mutation in our cohort but evidenced variants undetected by our frequent mutations kit. Thanks to the progress of sequencing techniques and despite the difficulties of interpretation occasionally encountered, we discuss the need to carry out a comprehensive CFTR study in all patients in case of fetal bowel abnormalities.


Assuntos
Fibrose Cística/diagnóstico por imagem , Intestino Ecogênico/diagnóstico por imagem , Testes Genéticos/normas , Ultrassonografia Pré-Natal/normas , Fibrose Cística/complicações , Fibrose Cística/etnologia , Fibrose Cística/genética , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Intestino Ecogênico/etiologia , Intestino Ecogênico/genética , Etnicidade/genética , Feminino , Frequência do Gene , Testes Genéticos/métodos , Humanos , Valor Preditivo dos Testes , Gravidez , Ultrassonografia Pré-Natal/métodos
18.
Taiwan J Obstet Gynecol ; 60(3): 401-404, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33966720

RESUMO

Third trimester ultrasound has long been in obstetrics a topic of debate. This issue is framed in a historical debate on the effectiveness of routine obstetrical ultrasound and two opposing trends originated in America and Europe, respectively. Primary function of this ultrasound has been to detect fetal growth restriction, but no study has shown evidence of improving perinatal outcomes. Other secondary functions are detection of fetal abnormalities or evaluation of fetal presentation, and they have also shown no evidence. Despite the continuous appearance of works in this regard, health policies of both american and european trends have not been modified. Future seems to show a prolongation of the stalemate. Those health systems with a universal third trimester policy should propose an optimization of the test, in order to improve the benefits and obtain data for future studies that could resolve this longstanding debate.


Assuntos
Obstetrícia/normas , Terceiro Trimestre da Gravidez , Ultrassonografia Pré-Natal/normas , Anormalidades Congênitas/diagnóstico por imagem , Anormalidades Congênitas/embriologia , Europa (Continente) , Feminino , Retardo do Crescimento Fetal/diagnóstico por imagem , Humanos , Gravidez , Estados Unidos
20.
BMC Pregnancy Childbirth ; 21(1): 328, 2021 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-33902496

RESUMO

BACKGROUND: Ninety-four percent of all maternal deaths occur in low- and middle-income countries, and the majority are preventable. Access to quality Obstetric ultrasound can identify some complications leading to maternal and neonatal/perinatal mortality or morbidity and may allow timely referral to higher-resource centers. However, there are significant global inequalities in access to imaging and many challenges to deploying ultrasound to rural areas. In this study, we tested a novel, innovative Obstetric telediagnostic ultrasound system in which the imaging acquisitions are obtained by an operator without prior ultrasound experience using simple scan protocols based only on external body landmarks and uploaded using low-bandwidth internet for asynchronous remote interpretation by an off-site specialist. METHODS: This is a single-center pilot study. A nurse and care technician underwent 8 h of training on the telediagnostic system. Subsequently, 126 patients (68 second trimester and 58 third trimester) were recruited at a health center in Lima, Peru and scanned by these ultrasound-naïve operators. The imaging acquisitions were uploaded by the telemedicine platform and interpreted remotely in the United States. Comparison of telediagnostic imaging was made to a concurrently performed standard of care ultrasound obtained and interpreted by an experienced attending radiologist. Cohen's Kappa was used to test agreement between categorical variables. Intraclass correlation and Bland-Altman plots were used to test agreement between continuous variables. RESULTS: Obstetric ultrasound telediagnosis showed excellent agreement with standard of care ultrasound allowing the identification of number of fetuses (100% agreement), fetal presentation (95.8% agreement, κ =0.78 (p < 0.0001)), placental location (85.6% agreement, κ =0.74 (p < 0.0001)), and assessment of normal/abnormal amniotic fluid volume (99.2% agreement) with sensitivity and specificity > 95% for all variables. Intraclass correlation was good or excellent for all fetal biometric measurements (0.81-0.95). The majority (88.5%) of second trimester ultrasound exam biometry measurements produced dating within 14 days of standard of care ultrasound. CONCLUSION: This Obstetric ultrasound telediagnostic system is a promising means to increase access to diagnostic Obstetric ultrasound in low-resource settings. The telediagnostic system demonstrated excellent agreement with standard of care ultrasound. Fetal biometric measurements were acceptable for use in the detection of gross discrepancies in fetal size requiring further follow up.


Assuntos
Assistência Perinatal , Consulta Remota/métodos , Desenvolvimento de Pessoal , Telemedicina/métodos , Ultrassonografia Pré-Natal , Diagnóstico Precoce , Intervenção Médica Precoce/normas , Feminino , Humanos , Obstetrícia/educação , Assistência Perinatal/métodos , Assistência Perinatal/normas , Peru/epidemiologia , Testes Imediatos/organização & administração , Gravidez , Trimestres da Gravidez , Melhoria de Qualidade/organização & administração , Serviços de Saúde Rural/normas , Serviços de Saúde Rural/tendências , Enfermagem Rural/métodos , Desenvolvimento de Pessoal/métodos , Desenvolvimento de Pessoal/organização & administração , Ultrassonografia Pré-Natal/métodos , Ultrassonografia Pré-Natal/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA