Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
Ultrasound Obstet Gynecol ; 58(6): 853-863, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34096674

RESUMO

OBJECTIVES: The primary aim of this study was to evaluate the feasibility of automated measurement of fetal atrioventricular (AV) plane displacement (AVPD) over several cardiac cycles using myocardial velocity traces obtained by color tissue Doppler imaging (cTDI). The secondary objectives were to establish reference ranges for AVPD during the second half of normal pregnancy, to assess fetal AVPD in prolonged pregnancy in relation to adverse perinatal outcome and to evaluate AVPD in fetuses with a suspicion of intrauterine growth restriction (IUGR). METHODS: The population used to develop the reference ranges consisted of women with an uncomplicated singleton pregnancy at 18-42 weeks of gestation (n = 201). The prolonged-pregnancy group comprised women with an uncomplicated singleton pregnancy at ≥ 41 + 0 weeks of gestation (n = 107). The third study cohort comprised women with a singleton pregnancy and suspicion of IUGR, defined as an estimated fetal weight < 2.5th centile or an estimated fetal weight < 10th centile and umbilical artery pulsatility index > 97.5th centile (n = 35). Cineloops of the four-chamber view of the fetal heart were recorded using cTDI. Regions of interest were placed at the AV plane in the left and right ventricular walls and the interventricular septum, and myocardial velocity traces were integrated and analyzed using an automated algorithm developed in-house to obtain mitral (MAPSE), tricuspid (TAPSE) and septal (SAPSE) annular plane systolic excursion. Gestational-age specific reference ranges were constructed and normalized for cardiac size. The correlation between AVPD measurements obtained using cTDI and those obtained by anatomic M-mode were evaluated, and agreement between these two methods was assessed using Bland-Altman analysis. The mean Z-scores of fetal AVPD in the cohort of prolonged pregnancies were compared between cases with normal and those with adverse outcome using Mann-Whitney U-test. The mean Z-scores of fetal AVPD in IUGR fetuses were compared with those in the normal reference population using Mann-Whitney U-test. Inter- and intraobserver variability for acquisition of cTDI recordings and offline analysis was assessed by calculating coefficients of variation (CV) using the root mean square method. RESULTS: Fetal MAPSE, SAPSE and TAPSE increased with gestational age but did not change significantly when normalized for cardiac size. The fitted mean was highest for TAPSE throughout the second half of gestation, followed by SAPSE and MAPSE. There was a significant correlation between MAPSE (r = 0.64; P < 0.001), SAPSE (r = 0.72; P < 0.001) and TAPSE (r = 0.84; P < 0.001) measurements obtained by M-mode and those obtained by cTDI. The geometric means of ratios between AVPD measured by cTDI and by M-mode were 1.38 (95% limits of agreement (LoA), 0.84-2.25) for MAPSE, 1.00 (95% LoA, 0.72-1.40) for SAPSE and 1.20 (95% LoA, 0.92-1.57) for TAPSE. In the prolonged-pregnancy group, the mean ± SD Z-scores for MAPSE (0.14 ± 0.97), SAPSE (0.09 ± 1.02) and TAPSE (0.15 ± 0.90) did not show any significant difference compared to the reference ranges. Twenty-one of the 107 (19.6%) prolonged pregnancies had adverse perinatal outcome. The AVPD Z-scores were not significantly different between pregnancies with normal and those with adverse outcome in the prolonged-pregnancy cohort. The mean ± SD Z-scores for SAPSE (-0.62 ± 1.07; P = 0.006) and TAPSE (-0.60 ± 0.89; P = 0.002) were significantly lower in the IUGR group compared to those in the normal reference population, but the differences were not significant when the values were corrected for cardiac size. The interobserver CVs for the automated measurement of MAPSE, SAPSE and TAPSE were 28.1%, 17.7% and 15.3%, respectively, and the respective intraobserver CVs were 33.5%, 15.0% and 17.9%. CONCLUSIONS: This study showed that fetal AVPD can be measured automatically by integrating cTDI velocities over several cardiac cycles. Automated analysis of AVPD could potentially help gather larger datasets to facilitate use of machine-learning models to study fetal cardiac function. The gestational-age associated increase in AVPD is most likely a result of increasing cardiac size, as the AVPD normalized for cardiac size did not change significantly between 18 and 42 weeks. A decrease was seen in TAPSE and SAPSE in IUGR fetuses, but not after correction for cardiac size. © 2021 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Nó Atrioventricular/diagnóstico por imagem , Ecocardiografia Doppler em Cores/estatística & dados numéricos , Coração Fetal/diagnóstico por imagem , Sístole/fisiologia , Ultrassonografia Pré-Natal/estatística & dados numéricos , Nó Atrioventricular/embriologia , Velocidade do Fluxo Sanguíneo , Estudos de Viabilidade , Feminino , Retardo do Crescimento Fetal/diagnóstico por imagem , Retardo do Crescimento Fetal/fisiopatologia , Coração Fetal/embriologia , Peso Fetal , Idade Gestacional , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/embriologia , Humanos , Gravidez , Fluxo Pulsátil , Valores de Referência , Volume Sistólico , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/embriologia , Septo Interventricular/diagnóstico por imagem , Septo Interventricular/embriologia
2.
Physiol Genomics ; 52(12): 563-574, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33044885

RESUMO

Calcific aortic valve disease (CAVD) is a significant cause of illness and death worldwide. Identification of early predictive markers could help optimize patient management. RNA-sequencing was carried out on human fetal aortic valves at gestational weeks 9, 13, and 22 and on a case-control study with adult noncalcified and calcified bicuspid and tricuspid aortic valves. In dimension reduction and clustering analyses, diseased valves tended to cluster with fetal valves at week 9 rather than normal adult valves, suggesting that part of the disease program might be due to reiterated developmental processes. The analysis of groups of coregulated genes revealed predominant immune-metabolic signatures, including innate and adaptive immune responses involving lymphocyte T-cell metabolic adaptation. Cytokine and chemokine signaling, cell migration, and proliferation were all increased in CAVD, whereas oxidative phosphorylation and protein translation were decreased. Discrete immune-metabolic gene signatures were present at fetal stages and increased in adult controls, suggesting that these processes intensify throughout life and heighten in disease. Cellular stress response and neurodegeneration gene signatures were aberrantly expressed in CAVD, pointing to a mechanistic link between chronic inflammation and biological aging. Comparison of the valve RNA-sequencing data set with a case-control study of whole blood transcriptomes from asymptomatic individuals with early aortic valve calcification identified a highly predictive gene signature of CAVD and of moderate aortic valve calcification in overtly healthy individuals. These data deepen and broaden our understanding of the molecular basis of CAVD and identify a peripheral blood gene signature for the early detection of aortic valve calcification.


Assuntos
Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/genética , Valva Aórtica/patologia , Calcinose/sangue , Calcinose/genética , Doenças Fetais/genética , Transcriptoma , Adulto , Valva Aórtica/embriologia , Estenose da Valva Aórtica/embriologia , Estenose da Valva Aórtica/epidemiologia , Doenças Assintomáticas , Biomarcadores/sangue , Calcinose/embriologia , Calcinose/epidemiologia , Estudos de Casos e Controles , Análise por Conglomerados , Feminino , Idade Gestacional , Humanos , Valva Mitral/embriologia , Valva Mitral/patologia , Gravidez , Estudos Prospectivos , RNA-Seq , Espanha/epidemiologia , Valva Tricúspide/embriologia , Valva Tricúspide/patologia
3.
J Perinat Med ; 48(6): 601-608, 2020 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-32609650

RESUMO

Objectives This study aimed to establish reference ranges for fetal mitral, tricuspid, and interventricular septum annular plane systolic excursions (MAPSE, TAPSE, and SAPSE) in normal pregnant women between 20 and 36 + 6 weeks of gestation. Methods This prospective and cross-sectional study included 360 low-risk singleton pregnancies between 20 and 36 + 6 weeks of gestation. MAPSE, TAPSE, and SAPSE were measured by M-mode in real time in an apical or basal four-chamber view through placing the cursor at the atrioventricular junction, marked by the valve rings at the tricuspid, mitral, and basal septum, respectively. A regression analysis was done to determine the appropriate polynomial equation model for both measurements and standard deviation (SD) values in relation to gestational age (GA). The intra- and inter-observer reproducibility was evaluated using the concordance correlation coefficient (CCC) and limits of agreement (LoA). Results There was a significant positive correlation between MAPSE (r=0.705, p<0.0001), TAPSE (r=0.804, p<0.0001), and SAPSE (r=0.690, p<0.0001) and GA. The mean of each parameter ranged as follows: 2.87-5.56 mm, MAPSE; 3.98-8.07 mm, TAPSE; and 2.34-4.21 mm, SAPSE. Poor/moderate intra- and inter-observer reliability (CCC between 0.70 and 0.90) and poor/moderate agreement of all the tested parameters were evaluated (LoA between 10 and 50%). Conclusions Reference values were established for the fetal MAPSE, TAPSE, and SAPSE between 20 and 36 + 6 weeks of gestation in low-risk pregnant women. These parameters showed poor/moderate reproducibility.


Assuntos
Coração Fetal/fisiologia , Valva Mitral/embriologia , Sístole/fisiologia , Valva Tricúspide/embriologia , Septo Interventricular/embriologia , Adulto , Estudos Transversais , Feminino , Coração Fetal/diagnóstico por imagem , Feto , Idade Gestacional , Humanos , Recém-Nascido , Valva Mitral/diagnóstico por imagem , Gravidez , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes , Valva Tricúspide/diagnóstico por imagem , Ultrassonografia Pré-Natal , Septo Interventricular/diagnóstico por imagem
4.
J Matern Fetal Neonatal Med ; 33(9): 1579-1586, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-30238805

RESUMO

Objectives: To establish Z-score models for early diastolic blood flow widths of mitral and tricuspid valves in normal fetuses and compare Z-scores and other blood flow dynamic parameters between normal fetuses and fetuses with dilated coronary sinus (CS). This study seeks to assess whether dilated CS affects cardiac structure or hemodynamics.Methods: One hundred twenty-nine normal fetuses (Group I) and 15 fetuses with dilated CS connected to persistent left superior vena cava (PLSVC) (Group II) were included in this study. Noncardiac biometrical parameters, including gestation age (GA), biparietal diameter (BPD), femoral length (FL), and heart area (HA), were obtained. Hemodynamic parameters, such as the early diastolic blood flow widths of mitral and tricuspid valves (MV-CDFI-Width, TV-CDFI-Width), velocity and time integral of blood flow (VTI), peak early and late diastolic velocity of mitral and tricuspid valves [peak early diastolic velocity of the mitral valve (MVE), peak late diastolic velocity of the mitral valve (MVA), peak early diastolic velocity of the tricuspid valve (TVE), peak late diastolic velocity of the tricuspid valve (TVA)], were measured.Results: Z-score models for MV-CDFI-Width and TV-CDFI-Width against noncardiac biometrical parameters were best described by linear regression analysis. The mean equations of MV-CDFI-Width against noncardiac biometrical parameters were 0.066 + (0.025 × GA), 0.169 + (0.084 × BPD), 0.213 + (0.106 × FL) and 0.533 + (0.028 × HA). The SD for MV-CDFI-Width against FL was estimated based on values from the following equation: -0.006 + (0.02 × FL). Other SDs were constants estimated as the standard deviations of the unscaled residuals. Z-scores and other blood flow dynamic parameters exhibited no statistically significant differences between Group I and Group II.Conclusions: This study demonstrated that dilated CS did not affect fetal hemodynamics of the mitral or tricuspid valves or cardiac structures. We also suggested that the causes of diminutive left heart or coarctation of the aorta might not be associated with dilated CS in fetuses with PLSVC.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Seio Coronário/embriologia , Valva Mitral/embriologia , Valva Tricúspide/embriologia , Estudos de Casos e Controles , Seio Coronário/diagnóstico por imagem , Ecocardiografia , Feminino , Coração Fetal/diagnóstico por imagem , Idade Gestacional , Cardiopatias Congênitas/embriologia , Humanos , Valva Mitral/diagnóstico por imagem , Gravidez , Valva Tricúspide/diagnóstico por imagem , Ultrassonografia Pré-Natal
5.
Ultrasound Obstet Gynecol ; 55(2): 226-232, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31008542

RESUMO

OBJECTIVES: Tricuspid valve dysplasia (TVD) and Ebstein's anomaly (EA) diagnosed by fetal echocardiography vary greatly in terms of clinical severity and prognosis. The Celermajer index and Simpson-Andrews-Sharland (SAS) score have been reported previously for the prediction of prognosis in cases of TVD/EA; however, they do not take into account the hemodynamic impact of left ventricular (LV) function, which has recently been implicated as being important in the pathophysiology of TVD/EA. The aim of this study was to develop a novel scoring system that includes LV function for the prediction of perinatal death in fetuses diagnosed with TVD/EA. METHODS: The clinical records of 36 fetuses diagnosed prenatally with TVD/EA between 2000 and 2015 in our hospital were reviewed. Univariate analysis was used to assess the association between perinatal death (defined as death between 22 weeks' gestation and 4 weeks after delivery) and gestational age at diagnosis, cardiothoracic area ratio (CTAR), degree of pulmonary artery flow, direction of ductal flow, right-to-left ventricular diameter ratio, tricuspid regurgitation (TR) maximum velocity, Celermajer index, SAS score and LV-Tei index. A new prognostic score, the TRIPP score (TRIcuspid malformation Prognosis Prediction score), was developed using the parameters found to be associated significantly with perinatal death. The predictive value of this score was assessed in an additional nine fetuses diagnosed with TVD/EA. RESULTS: Thirty-six fetuses were diagnosed prenatally with TVD/EA, two of which were terminated, one was lost to follow-up and two died before 22 weeks' gestation. Of the 31 included fetuses, 10 (32%) died in the perinatal period. Univariate analysis demonstrated that TR maximum velocity was significantly lower (2.22 ± 0.17 m/s vs 3.26 ± 0.12 m/s; P < 0.001) and SAS score was significantly higher (5.7 ± 0.6 points vs 2.8 ± 0.4 points; P = 0.0014) in cases of perinatal death than in surviving fetuses. The degree of pulmonary artery flow and the direction of ductal flow were also associated significantly with perinatal death (P < 0.01 for both). Notably, LV-Tei index was significantly higher in cases of perinatal death than in surviving fetuses (0.81 ± 0.08 vs 0.50 ± 0.05; P < 0.001). In contrast, there was no significant difference in Celermajer index, CTAR or right-to-left ventricular diameter ratio. Finally, we established a novel combinatorial scoring system, the TRIPP score, including the four significant factors: TR maximum velocity, pulmonary artery flow, direction of ductal flow and LV-Tei index. The TRIPP score was found to predict efficiently perinatal mortality in fetuses with TVD/EA. CONCLUSIONS: Our novel combinatorial score of echocardiographic parameters, the TRIPP score, including LV-Tei index, is easy to measure and provides a good tool for the prediction of perinatal mortality in fetuses diagnosed prenatally with TVD/EA. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Regras de Decisão Clínica , Anomalia de Ebstein/diagnóstico , Ecocardiografia/métodos , Cardiopatias Congênitas/diagnóstico , Diagnóstico Pré-Natal/métodos , Insuficiência da Valva Tricúspide/diagnóstico , Anomalia de Ebstein/embriologia , Anomalia de Ebstein/mortalidade , Feminino , Idade Gestacional , Cardiopatias Congênitas/embriologia , Cardiopatias Congênitas/mortalidade , Humanos , Recém-Nascido , Morte Perinatal/etiologia , Mortalidade Perinatal , Valor Preditivo dos Testes , Gravidez , Prognóstico , Estudos Retrospectivos , Valva Tricúspide/embriologia , Insuficiência da Valva Tricúspide/embriologia , Insuficiência da Valva Tricúspide/mortalidade , Função Ventricular Esquerda
6.
Dev Biol ; 458(1): 88-97, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31669335

RESUMO

Atrioventricular valve development requires endothelial-to-mesenchymal transition (EndMT) that induces cushion endocardial cells to give rise to mesenchymal cells crucial to valve formation. In the adult endothelium, deletion of the docking protein FRS2α induces EndMT by activating TGFß signaling in a miRNA let-7-dependent manner. To study the role of endothelial FRS2α during embryonic development, we generated mice with an inducible endothelial-specific deletion of Frs2α (FRS2αiECKO). Analysis of the FRS2αiECKO embryos uncovered a combination of impaired EndMT in AV cushions and defective maturation of AV valves leading to development of thickened, abnormal valves when Frs2α was deleted early (E7.5) in development. At the same time, no AV valve developmental abnormalities were observed after late (E10.5) deletion. These observations identify FRS2α as a pivotal controller of cell fate transition during both EndMT and post-EndMT valvulogenesis.


Assuntos
Coxins Endocárdicos/embriologia , Regulação da Expressão Gênica no Desenvolvimento , Proteínas de Membrana/fisiologia , Animais , Contagem de Células , Linhagem da Célula , Comunicação Atrioventricular/embriologia , Comunicação Atrioventricular/genética , Coxins Endocárdicos/citologia , Coxins Endocárdicos/patologia , Células Endoteliais/citologia , Deleção de Genes , Proteínas de Membrana/deficiência , Proteínas de Membrana/genética , Mesoderma/citologia , Mesoderma/embriologia , Camundongos , Camundongos Endogâmicos C57BL , MicroRNAs/fisiologia , Valva Mitral/anormalidades , Valva Mitral/embriologia , Morfogênese/genética , Fenótipo , Valva Tricúspide/anormalidades , Valva Tricúspide/embriologia
7.
J Ultrasound Med ; 39(5): 929-937, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31737932

RESUMO

OBJECTIVES: The aim of this study was to construct reference ranges for fetal tricuspid annular plane systolic excursion (TAPSE) and mitral annular plane systolic excursion (MAPSE) using conventional M-mode ultrasound (US) in the second half of pregnancy. METHODS: Participants underwent US scans every 4 weeks from 18 weeks' gestation until delivery. The TAPSE and MAPSE were measured by conventional M-mode US at each examination. The relationships between TAPSE and MAPSE and gestational age and estimated fetal weight were modeled by Bayesian mixed effects linear regression. RESULTS: Positive linear relationships were observed between both MAPSE and TAPSE and gestational age and estimated fetal weight. Reference centiles for TAPSE and MAPSE were developed. CONCLUSIONS: This simple technique is a useful tool for assessing cardiac function and could be used for quantitative assessments of fetal cardiac function, particularly in high-risk pregnancies such as those complicated by maternal diabetes.


Assuntos
Ecocardiografia/métodos , Valva Mitral/anatomia & histologia , Valva Mitral/embriologia , Valva Tricúspide/anatomia & histologia , Valva Tricúspide/embriologia , Ultrassonografia Pré-Natal/métodos , Adulto , Austrália , Teorema de Bayes , Feminino , Humanos , Estudos Longitudinais , Gravidez , Estudos Prospectivos , Valores de Referência
8.
J Obstet Gynaecol Res ; 45(11): 2150-2157, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31441198

RESUMO

AIM: To evaluate the level of agreement between M-mode and pulsed-wave tissue Doppler imaging (PW-TDI) techniques in assessing fetal mitral annular plane systolic excursion (MAPSE), tricuspid annular plane systolic excursion (TAPSE) and septal annular plane systolic excursion (SAPSE) in a low-risk population. METHODS: This prospective longitudinal study included healthy fetuses assessed from 18 to 40 weeks of gestation. Tricuspid annular plane systolic excursion, MAPSE and SAPSE were measured using anatomical M-mode and PW-TDI. The agreement between the two diagnostic tests was assessed using Bland-Altman analysis. RESULTS: Fifty fetuses were included in the final analysis. Mean values of TASPE were higher than that of MAPSE. There was a progressive increase of TAPSE, MAPSE and SAPSE values with advancing gestation. For each parameter assessed, there was an overall good agreement between the measurements obtained with M-mode and PW-TDI techniques. However, the measurements made with M-mode were slightly higher than those obtained with PW-TDI (mean differences: 0.03, 0.05 and 0.03 cm for TAPSE, MAPSE and SAPSE, respectively). When stratifying the analyses by gestational age, the mean values of TAPSE, MAPSE and SAPSE measured with M-Mode were higher compared to those obtained with PW-TDI, although the mean differences between the two techniques tended to narrow with increasing gestation. Tricuspid annular plane systolic excursion, MAPSE and SAPSE measurements were all significantly, positively associated with gestational age (all P < 0.001). CONCLUSION: Fetal atrioventricular annular plane displacement can be assessed with M-mode technique, or with PW-TDI as the velocity-time integral of the myocardial systolic waveform. Atrioventricular annular plane displacement values obtained with M-mode technique are slightly higher than those obtained with PW-TDI.


Assuntos
Ecocardiografia Doppler de Pulso/estatística & dados numéricos , Coração Fetal/diagnóstico por imagem , Ultrassonografia Pré-Natal/estatística & dados numéricos , Adulto , Ecocardiografia Doppler de Pulso/métodos , Feminino , Coração Fetal/embriologia , Coração Fetal/fisiologia , Idade Gestacional , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/embriologia , Humanos , Estudos Longitudinais , Valva Mitral/diagnóstico por imagem , Valva Mitral/embriologia , Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes , Sístole , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/embriologia , Ultrassonografia Pré-Natal/métodos
9.
J Obstet Gynaecol ; 38(3): 408-412, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29355062

RESUMO

We examined the foetal cardiac structural and functional characteristics in diabetic pregnancies versus non-diabetic, healthy pregnancies. Between August 2015 and April 2016, 32 pregnant women with pregestational diabetes, 36 pregnant women with gestational diabetes, and 42 healthy pregnant women were scheduled to have foetal echocardiograms to assess cardiac structure and function. In the diabetic groups, the foetal interventricular septum (IVS) thickness was significantly greater than in non-diabetics (p < .05) but none had an IVS >2 SD from normal. The peak velocity of tricuspid E, and the E/A ratio were significantly lower in the diabetic groups (p < .05). Tricuspid valve Ea values and the Ea/Aa ratio were lower in the diabetic group than in the control group (p < .05) but there was no significant difference between the pre-GDM and GDM groups (p > .05). Interventricular septal hypertrophy is the most common structural abnormality in diabetic pregnancies. These changes do not pose a risk to the foetal unless they cause functional impairment. Thus, we believe that it is important for diabetic pregnant women to be monitored for foetal cardiac diastolic dysfunction. Impact statement What is already known on this subject? Pregestational insulin-dependent diabetes mellitus is a relatively common condition in pregnancy, affecting up to 0.5% of the pregnant population. Foetuses of diabetic mothers are at an increased risk of perinatal morbidity and death. Gestational diabetes mellitus is under-recognised and affects up to 4% of pregnancies. Although diabetes mellitus is known to increase the risk of cardiovascular defects and structural changes (myocardial hypertrophy and diastolic dysfunction) due to foetal hyperglycaemia and hyperinsulinism, similar data in women with gestational diabetes is scarce. Moreover, the effect of maternal hyperglycaemia on foetal cardiac structure and function is unclear because of discordant results from previous studies. What do the results of this study add? In this study, we have used foetal echocardiography, two-dimensional US, pulsed wave Doppler and TDI to characterise the foetal cardiac structure and function in normal pregnancies as well as in the pregnancies complicated by GDM, and pregestational DM. Interventricular septum thickness is increased in women with pregestational diabetes mellitus and impaired diastolic function. The dominant right ventricle of the foetal circulation was affected earlier than the left ventricle. What are the implications of these findings for clinical practice and/or further research? Large population-based studies are required to establish the absolute risk of congenital heart defects in patients with pregestational diabetes and pregestational diabetes in the utility of routine screening.


Assuntos
Diabetes Mellitus Tipo 1/complicações , Diabetes Gestacional/fisiopatologia , Coração Fetal/patologia , Coração Fetal/fisiopatologia , Hipertrofia/etiologia , Complicações na Gravidez/fisiopatologia , Adulto , Diástole , Ecocardiografia , Feminino , Coração Fetal/diagnóstico por imagem , Idade Gestacional , Humanos , Hiperglicemia/complicações , Insulina/efeitos adversos , Insulina/uso terapêutico , Cuidado Pré-Concepcional , Gravidez , Complicações na Gravidez/patologia , Valva Tricúspide/embriologia , Valva Tricúspide/fisiopatologia , Ultrassonografia Pré-Natal/métodos , Septo Interventricular/embriologia , Septo Interventricular/patologia
10.
Cardiol Young ; 27(8): 1637-1640, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28534460

RESUMO

This brief report describes a case of flail anterior tricuspid valve leaflet in a neonate associated with maternal antiphospholipid syndrome. Fetal echocardiography at 27 weeks of gestation showed competent atrioventricular valves with biventricular echogenic chordae. Fetal distress was noted at delivery, and echocardiography showed a flail anterior leaflet of the tricuspid valve with severe regurgitation. Possible causation and implications of maternal antiphospholipid syndrome are discussed.


Assuntos
Síndrome Antifosfolipídica/complicações , Doenças Fetais/diagnóstico , Complicações na Gravidez , Efeitos Tardios da Exposição Pré-Natal , Insuficiência da Valva Tricúspide/diagnóstico , Valva Tricúspide/diagnóstico por imagem , Adulto , Síndrome Antifosfolipídica/diagnóstico , Ecocardiografia , Feminino , Humanos , Recém-Nascido , Gravidez , Valva Tricúspide/embriologia , Insuficiência da Valva Tricúspide/embriologia , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/fisiopatologia , Ultrassonografia Pré-Natal
11.
J Clin Ultrasound ; 45(6): 370-374, 2017 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-27753109

RESUMO

The anatomic causes for fetal right atrial dilatation with tricuspid regurgitation include Ebstein anomaly, tricuspid dysplasia, unguarded tricuspid orifice, and Uhl anomaly. Unguarded tricuspid orifice is characterized by complete or partial agenesis of the tricuspid valvular and subvalvular structures. It is commonly associated with pulmonary atresia. Its prenatal diagnosis is usually associated with unfavorable prognosis. We present a prenatally diagnosed case of fetal unguarded tricuspid orifice with description of its diagnostic workup, along with a review of literature, to enhance the understanding of this rarely reported entity. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:370-374, 2017.


Assuntos
Ecocardiografia Doppler em Cores/métodos , Valva Tricúspide/anormalidades , Valva Tricúspide/embriologia , Ultrassonografia Pré-Natal/métodos , Aborto Eugênico , Adulto , Dilatação Patológica , Feminino , Humanos , Gravidez , Valva Tricúspide/diagnóstico por imagem
12.
Prenat Diagn ; 35(8): 741-7, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26125132

RESUMO

OBJECTIVE: Our aim is to evaluate the feasibility to examine the morphology and area of the atrioventricular (AV) valves in normal fetuses and fetuses with cardiac defects using spatiotemporal image correlation (STIC). METHODS: Atrioventricular valves were analyzed longitudinally in STIC volumes of 74 normal fetuses between the 15th and 36th week of pregnancy. The valve area was measured in a rendered view in diastole, the number of valve leaflets in systole. Longitudinal data analysis was performed using linear mixed models. Fifty fetuses with cardiac defects were examined. RESULTS: Examination of 355 STIC volumes of normal fetuses showed in 82.5% sufficient quality. The tricuspid valve leaflets were seen in 200 (68.3%) volumes and the mitral valve leaflets in 219 (74.7%) volumes. The tricuspid valve showed in 61.1% a round, 29.0% rectangle, and 8.9% elliptical shape and the mitral valve in 60.1% round, 28.0% rectangle, and 10.9% elliptical. Regression analysis revealed a positive relationship of the valve area with gestational age (p < 0.0001). Most heart defects with stenosis showed an area below the 5th percentile. CONCLUSION: Prenatal examination of the morphology and area of the AV valves using four-dimensional ultrasound is feasible. A rectangular valve opening is normal, which was visualized in about one third of the normal fetuses.


Assuntos
Ecocardiografia Quadridimensional , Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Valva Tricúspide/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Estudos de Casos e Controles , Estudos de Viabilidade , Feminino , Coração Fetal/anormalidades , Coração Fetal/embriologia , Cardiopatias Congênitas/embriologia , Humanos , Modelos Lineares , Estudos Longitudinais , Valva Mitral/anormalidades , Valva Mitral/embriologia , Gravidez , Segundo Trimestre da Gravidez , Terceiro Trimestre da Gravidez , Estudos Prospectivos , Valores de Referência , Análise Espaço-Temporal , Valva Tricúspide/anormalidades , Valva Tricúspide/embriologia
13.
J Matern Fetal Neonatal Med ; 28(12): 1375-80, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25123513

RESUMO

OBJECTIVE: To assess the viewing rate and reproducibility of areas of the papillary muscles (PMs) of foetal atrioventricular valves using spatio-temporal image correlation (STIC) in the rendering mode in congenital heart disease (CHD). METHODS: We retrospectively reviewed 40 4D-STIC volume datasets from different foetal CHD cases at a gestational age of 18w6d­35w6d. The following papillary muscles (PMs) were assessed: antero-lateral (MPAL) and postero-medial (MPPM) to the mitral valve and antero-superior (MPAS), inferior (MPI) and septal (MPS) to the tricuspid valve. To assess the valve viewing rate, percentages (%) were used. The concordance correlation coefficient (CCC) was used to assess inter-observer reliability. RESULTS: Two independent observers concluded that a complete examination of the PMs was impossible in 11 cases, yielding a viewing rate of 72.5%. The complete examination of the PMs of the tricuspid and mitral valves was possible by both examiners in 33/40 (82.5%) and 32/40 (80.0%) cases, respectively. We observed moderate to good inter-observer reliability with CCCs of 0.95, 0.92, 0.97, 0.96 and 0.97 for MPS, MPI, MPAS, MPAL and MPPM, respectively. CONCLUSION: The viewing rate of PM areas in different CHDs using STIC in the rendering mode was moderate. The inter-observer reproducibility was moderate to good for all PM areas.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/embriologia , Valvas Cardíacas/embriologia , Músculos Papilares/diagnóstico por imagem , Músculos Papilares/embriologia , Ultrassonografia Pré-Natal/métodos , Ecocardiografia Quadridimensional , Feminino , Coração Fetal/diagnóstico por imagem , Idade Gestacional , Valvas Cardíacas/diagnóstico por imagem , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/embriologia , Variações Dependentes do Observador , Gravidez , Reprodutibilidade dos Testes , Estudos Retrospectivos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/embriologia
14.
Prenat Diagn ; 35(3): 236-43, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25378021

RESUMO

OBJECTIVES: We aimed to construct reference ranges for time intervals of each component of cardiac flow velocity waveforms in normal fetuses, comparing those variables between right and left ventricles. METHODS: In 359 fetuses at the gestational age of 17-38 weeks, the durations of atrioventricular (AV) valve opening (AVVO), AV valve closure (AVVC), total E- (total-E) and A- (total-A) waves, total ejection time (total-ET), acceleration time (acc-E for E-wave, acc-A for A-wave, and acc-ET for ejection time), and deceleration time (dec-E for E-wave, dec-A for A-wave, and dec-ET for ejection time) were studied cross sectionally. RESULTS: Both right and left acc-E showed the strongest correlations with gestational age (r = 0.478 and r = 0.519, respectively). Left AVVO showed a stronger correlation (r = 0.474) than right AVVO (r = 0.282) and, conversely, right AVVC showed a stronger correlation (r = 0.399) than left AVVC (r = 0.195) with gestational age. Significant differences (all P values <0.001) were observed for all right and left parameters other than total-A and acc-E. CONCLUSIONS: Characteristic differences between right and left ventricles were found in the reference ranges, suggesting the developmental properties of the fetal heart. © 2014 John Wiley & Sons, Ltd.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Coração Fetal/fisiologia , Valvas Cardíacas/fisiologia , Valva Aórtica/embriologia , Valva Aórtica/fisiologia , Estudos Transversais , Ecocardiografia Doppler , Feminino , Desenvolvimento Fetal , Coração Fetal/embriologia , Idade Gestacional , Valvas Cardíacas/embriologia , Humanos , Modelos Lineares , Valva Mitral/embriologia , Valva Mitral/fisiologia , Gravidez , Segundo Trimestre da Gravidez , Terceiro Trimestre da Gravidez , Valva Pulmonar/embriologia , Valva Pulmonar/fisiologia , Valores de Referência , Valva Tricúspide/embriologia , Valva Tricúspide/fisiologia , Ultrassonografia Pré-Natal
16.
Ultrasound Obstet Gynecol ; 42(2): 175-81, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23280816

RESUMO

OBJECTIVE: To compare the ability of two different methods for longitudinal annular motion measurement, M-mode and tissue Doppler imaging (TDI), to demonstrate cardiac dysfunction in intrauterine-growth-restricted (IUGR) fetuses. METHODS: Cardiac longitudinal annular motion in the basal free wall of the left ventricle (mitral annulus), interventricular septum and tricuspid annulus was assessed in 23 early-onset IUGR cases and 43 controls by TDI (annular peak velocities) and M-mode (displacement). RESULTS: All annular parameters were significantly decreased in the IUGR group with respect to controls using both methods. M-mode showed a trend towards equal performance as classifier between cases and controls, as compared to TDI, mainly in the tricuspid annulus. CONCLUSIONS: Both M-mode and TDI demonstrate annular motion changes and consequently cardiac dysfunction in IUGR fetuses. M-mode imaging is simpler to perform and could be as sensitive as TDI for detecting subtle changes.


Assuntos
Retardo do Crescimento Fetal/fisiopatologia , Coração Fetal/fisiopatologia , Cardiopatias/fisiopatologia , Ecocardiografia Doppler/métodos , Feminino , Coração Fetal/embriologia , Cardiopatias/diagnóstico por imagem , Cardiopatias/embriologia , Septos Cardíacos/embriologia , Septos Cardíacos/fisiologia , Ventrículos do Coração/embriologia , Humanos , Valva Mitral/embriologia , Valva Mitral/fisiologia , Movimento/fisiologia , Valva Tricúspide/embriologia , Valva Tricúspide/fisiologia , Ultrassonografia Pré-Natal/métodos , Função Ventricular/fisiologia
17.
Ultrasound Obstet Gynecol ; 42(2): 182-8, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23288668

RESUMO

OBJECTIVES: Fetal tricuspid annular plane systolic excursion (f-TAPSE) is a modified method to measure the vertical movement of the tricuspid valve annulus by M-mode ultrasound, in order to assess the fetal right heart. Evaluation of right heart function is well-recognized in pediatric and adult cardiology, but has not been studied widely in the fetus. We aimed to study f-TAPSE in the second half of gestation in normal fetuses, to establish reference ranges for this measure, to evaluate the usefulness of spatiotemporal image correlation (STIC) M-mode in obtaining it, and to compare conventional M-mode and STIC M-mode-based measures of f-TAPSE. METHODS: We recruited gravidae presenting to our centers from 20 to 38 weeks for targeted organ scans, fetal echocardiography or third-trimester fetal surveillance, with structurally normal singleton fetuses and verified gestational age (GA). Because of the small number of subjects at the lower limit, fetuses at 20 and those at 21 weeks were combined into a single group ('21 weeks'). During the booked scan, in addition to standard biometry, M-mode was applied to the tricuspid annulus, parallel to the ventricular septum, and the amplitude of the resulting wave was measured. To allow comparison with STIC M-mode, a STIC volume was acquired and saved. In post-processing, the volume was rotated to show an apical four-chamber view, and f-TAPSE was investigated in a similar fashion to that used for conventional M-mode. Two to three measures of TAPSE were taken and the results averaged. In thirty women, measurements were performed by two observers and inter- and intraobserver variation were calculated. RESULTS: We examined 341 fetuses at GA 20-39 weeks. Conventional M-mode f-TAPSE values ranged from a mean of 3.6 (± 1.1) mm at 21 weeks to a mean of 8.6 (± 1.5) mm at 39 weeks. In 45 cases we were unable to perform conventional M-mode ultrasound because of fetal lie; in eight cases STIC volumes were found in post-processing to be unsuitable for analysis. STIC f-TAPSE values ranged from a mean of 4.2 (± 1.4) mm at 21 weeks to a mean of 8.3 (± 1.5) mm at 39 weeks. Scatterplots of f-TAPSE measures obtained with conventional M-mode and with STIC M-mode were created vs GA and estimated fetal weight (EFW). For both modalities, f-TAPSE increased linearly with GA and with EFW. Good correlation was found between the two methods (Pearson's R(2) = 0.904). No significant difference was found in mean or variance of the distributions or slopes of the regression equations. Inter- and intraobserver variation (intraclass correlation coefficient) in conventional M-mode and STIC M-mode f-TAPSE measures were 0.94 and 0.97, respectively. CONCLUSION: F-TAPSE in normal fetuses increases over the course of gestation and correlates to EFW. F-TAPSE measurement is easy to perform and available on all ultrasound machines; STIC f-TAPSE is possible on machines with STIC capability and produces similar measures with a greater success rate. We suggest the addition of f-TAPSE measurement to fetal right cardiac function evaluation.


Assuntos
Coração Fetal/fisiologia , Valva Tricúspide/fisiologia , Função Ventricular Direita/fisiologia , Adulto , Ecocardiografia , Feminino , Coração Fetal/diagnóstico por imagem , Coração Fetal/embriologia , Idade Gestacional , Humanos , Idade Materna , Movimento/fisiologia , Variações Dependentes do Observador , Gravidez , Padrões de Referência , Análise Espaço-Temporal , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/embriologia , Ultrassonografia Pré-Natal/métodos
18.
Cardiol Rev ; 21(5): 257-63, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23269033

RESUMO

Ebstein anomaly (EA) is a congenital defect of the tricuspid valve (TV) and the right ventricle (RV) in which the attachments of the septal and posterior valve leaflets are apically displaced. The latter creates 3 morphologic components inside the right heart, namely the right atrium proper, the atrialized RV, and the functional RV. This rare anomaly accounts for <1.5% of all congenital heart diseases. The current opinion among authors is that it is a genetically heterogeneous condition caused by failure of delamination of the TV leaflets from the underlying myocardium and the interventricular septum. Its characteristic electrocardiographic findings include tall, broad, right atrial P waves, prolonged PR intervals, and deep Q waves in the right precordial leads. Echocardiography is currently the best technique for diagnosing this anomaly, although cardiac magnetic resonance imaging is also gaining traction as an alternative modality. The management strategies for EA correlate with the age of the patient, severity of the heart disease, and/or associated cardiac abnormalities. TV repair, rather than valve replacement, is preferred because of its favorable long-term prognosis. Nevertheless, a large, randomized study is still needed to compare the different valve repair techniques used in patients with EA.


Assuntos
Anomalia de Ebstein/induzido quimicamente , Compostos de Lítio/efeitos adversos , Diagnóstico Diferencial , Anomalia de Ebstein/diagnóstico , Anomalia de Ebstein/terapia , Eletrocardiografia , Feminino , Humanos , Gravidez , Efeitos Tardios da Exposição Pré-Natal/induzido quimicamente , Prognóstico , Valva Tricúspide/embriologia
19.
Prenat Diagn ; 33(1): 50-5, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23148015

RESUMO

OBJECTIVE: This study aims to determine reference curves for fetal atrioventricular valve areas by means of three-dimensional ultrasound using the spatiotemporal image correlation (STIC) software. METHODS: This was a cross-sectional prospective study on 328 normal fetuses between the 18th and the 33rd weeks of pregnancy. In order to obtain valve areas, the four heart chambers plane was used with the fetus in a dorsal posterior position. To construct reference ranges, a linear regression model was used, adjusted according to the coefficient of determination (R(2)). To calculate the reproducibility of the tricuspid valve area, the intraclass coefficient correlation (ICC) was used. RESULTS: The mean areas of the tricuspid and mitral valves ranged from 0.19 ± 0.08 and 0.20 ± 0.10 cm(2) in the 18th week to 0.93 ± 0.31 and 1.06 ± 0.39 cm(2) in the 33rd week, respectively. The intra-observer and interobserver reproducibility was excellent with ICC = 0.997 and 0.933, respectively. CONCLUSIONS: Reference curves for fetal atrioventricular valve areas were determined and presented good reproducibility.


Assuntos
Ecocardiografia Quadridimensional , Coração Fetal/diagnóstico por imagem , Valvas Cardíacas/diagnóstico por imagem , Valvas Cardíacas/embriologia , Ultrassonografia Pré-Natal/métodos , Estudos Transversais , Feminino , Idade Gestacional , Humanos , Processamento de Imagem Assistida por Computador , Valva Mitral/diagnóstico por imagem , Valva Mitral/embriologia , Gravidez , Estudos Prospectivos , Valores de Referência , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/embriologia
20.
Fetal Diagn Ther ; 32(1-2): 65-71, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22613840

RESUMO

AIM: To evaluate the feasibility of offline anatomic M-mode (AMM) to study fetal atrioventricular annulus long-axis displacement (LAD) and compare its performance against real-time conventional M-mode (MM). MATERIAL AND METHODS: Paired AMM and MM LAD studies were recorded prospectively in 54 fetuses, and performance was compared. Insonation angles were less than 30° in all but 4 cases. The overall feasibility of AMM was tested in a composite total sample of 91 normal singleton pregnancies (median gestational age 23⁺6 weeks, range 12-36). AMM LAD was measured by placement of a virtual M-mode line on digitally stored raw data of fetal 4-chamber video loops. We studied annulus LAD at the lateral mitral (left ventricle; LV), proximal mitral (intraventricular septum; IVS), and lateral tricuspid (right ventricle; RV) myocardial segments. We compared LAD and its regression with gestational age measured using both methods in paired studies and AMM in the whole cohort. RESULTS: Annulus LAD was measured using AMM, in all cases and segments, irrespective of cardiac axis alignment to the ultrasound beam. Good correlation existed between AMM and MM (RV r = 0.901, LV r = 0.899, IVS r = 0.815, p < 0.001). AMM recorded higher LAD values than MM in RV [mean 6.17 (SD 1.46) vs. 5.82 (SD 1.74) mm, p = 0.002] and LV [mean 4.18 (SD 1.11) vs. 3.98 (SD 1.12), p = 0.007]. Both methods showed LAD in RV > LV > IVS and a significant gestational increase in LAD values in all segments (p < 0.001) CONCLUSIONS: AMM permits offline evaluation of fetal longitudinal myocardial function in routinely obtained 2D fetal heart images with similar values to conventional MM in paired studies recorded <30°.


Assuntos
Coração/embriologia , Coração/fisiologia , Contração Miocárdica , Ultrassonografia Pré-Natal/métodos , Estudos de Coortes , Ecocardiografia , Estudos de Viabilidade , Feminino , Idade Gestacional , Humanos , Processamento de Imagem Assistida por Computador , Modelos Lineares , Valva Mitral/diagnóstico por imagem , Valva Mitral/embriologia , Valva Mitral/fisiologia , Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/embriologia , Valva Tricúspide/fisiologia , Gravação em Vídeo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA