Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
1.
Khirurgiia (Mosk) ; (2. Vyp. 2): 5-12, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38380459

RESUMO

OBJECTIVE: To justify the optimal method for determining indocyanine green plasma disappearance rate (PDRICG). MATERIAL AND METHODS: We analyzed PDRICG in intensive care units. Indocyanine green was administered intravenously at a dose of 0.25 mg/kg. PDRICG was analyzed simultaneously by using of three methods: 1) PDD (PiCCO2 LiMON device), 2) SBS with analysis of plasma samples on precise spectrophotometer, 3) SBS with analysis of plasma samples on simple experimental photometer. RESULTS: PDD method was used for 346 PDRICG tests in 256 patients. Of these, 14.3% of measurements were erroneous. Paired tests using PDD and SBS methods were performed in 299 cases. SBS method resulted erroneous data in 0.6% of cases. Certain correlation (r=0.79, p<0.001) was found between the reference method (SBS with spectrophotometry) and the PDD method. Bland-Altman plot for these two methods showed that proportional bias of mean difference was caused by extremely high PDRICG of the PDD method (for example, more than 30%/min). Comparison of two SBS variants (spectrophotometer and experimental photometer) revealed good correlation (r=0.91, p<0.001). CONCLUSION: SBS method for measuring PDRICG ensures accurate results under mechanical interferences in patients with impaired capillary blood flow. This eliminates the need for redo measurement. Duplication of the PDD and SBS methods is recommended when repeating the test is not possible (organ donors).


Assuntos
Corantes , Verde de Indocianina , Humanos , Verde de Indocianina/análise , Corantes/farmacologia , Densitometria/métodos , Hemodinâmica/fisiologia , Unidades de Terapia Intensiva
2.
CEN Case Rep ; 11(4): 471-476, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35428968

RESUMO

Pleuroperitoneal communication is a severe complication in peritoneal dialysis, and about half of the patients forced to discontinue peritoneal dialysis. The method of coloring dialysis solution by indocyanine green or CT peritoneography have been reported to make diagnosis of pleuroperitoneal communication, however sensitivity of these tests is not a satisfactory level. By repairing the pleural hole with thoracoscopic surgery, it is possible to resume peritoneal dialysis. However, the recurrence rate is very high unless precisely detecting the location of the pleural hole during surgery. We report three cases of pleuroperitoneal communication in peritoneal dialysis patients, in which we found the combination of contrast-enhanced ultrasonography and the indocyanine green fluorescence system are reliable method to make diagnosis and identify the location of leakage of pleuroperitoneal communication. By making definite diagnosis and precisely identifying the localization, we were able to close diaphragm holes by video-assisted thoracoscopic surgery.


Assuntos
Diálise Peritoneal , Doenças Peritoneais , Doenças Pleurais , Humanos , Verde de Indocianina/análise , Diálise Peritoneal/efeitos adversos , Doenças Peritoneais/diagnóstico , Doenças Peritoneais/etiologia , Doenças Peritoneais/cirurgia , Doenças Pleurais/diagnóstico , Doenças Pleurais/etiologia , Doenças Pleurais/cirurgia , Ultrassonografia , Meios de Contraste , Fluorescência , Cirurgia Torácica Vídeoassistida
3.
Bioconjug Chem ; 32(8): 1541-1547, 2021 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-34309379

RESUMO

Recently, shortwave-infrared (SWIR) fluorescence imaging for the optical diagnostics of diseases has attracted much attention as a new noninvasive imaging modality. For this application, the development of SWIR molecular imaging probes with high biocompatibility is crucial. Although many types of biocompatible SWIR fluorescent probes based on organic dyes have been reported, there are no SWIR-emitting molecular imaging probes that can be used for the detection of specific biomolecules in vivo. To apply SWIR-emitting molecular imaging probes to biomedical fields, we developed a biocompatible SWIR fluorescent dye based on π-conjugation extended indocyanine green (ICG), where ICG is the only approved near-infrared dye by the US Food and Drug Administration (FDA) for use in the clinic. Using the π-conjugation extended ICG, we prepared SWIR molecular imaging probes that can be used for in vivo tumor imaging. Herein, we demonstrate noninvasive SWIR fluorescence imaging of human epidermal growth factor receptor 2 (HER2)-positive and epidermal growth factor receptor (EGFR)-positive breast tumors using π-conjugation extended ICG and monoclonal antibody conjugates. The presented π-conjugation extended ICG analog probes will be a breakthrough to apply SWIR fluorescence imaging in biomedical fields.


Assuntos
Neoplasias da Mama/patologia , Receptores ErbB/análise , Corantes Fluorescentes/análise , Verde de Indocianina/análise , Receptor ErbB-2/análise , Neoplasias da Mama/diagnóstico por imagem , Linhagem Celular Tumoral , Feminino , Corantes Fluorescentes/química , Humanos , Verde de Indocianina/análogos & derivados , Imagem Molecular/métodos , Imagem Óptica/métodos
4.
Crit Care ; 25(1): 21, 2021 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-33413583

RESUMO

BACKGROUND: Several studies have shown that heart rate control with selective beta-1 blockers in septic shock is safe. In these trials, esmolol was administered 24 h after onset of septic shock in patients who remained tachycardic. While an earlier use of beta-blockers might be beneficial, such use remains challenging due to the difficulty in distinguishing between compensatory and non-compensatory tachycardia. Therefore, the Esmosepsis study was designed to study the effects of esmolol aimed at reducing the heart rate by 20% after the initial resuscitation process in hyperkinetic septic shock patients on (1) cardiac index and (2) systemic and regional hemodynamics as well as inflammatory patterns. METHODS: Nine consecutive stabilized tachycardic hyperkinetic septic shock patients treated with norepinephrine for a minimum of 6 h were included. Esmolol was infused during 6 h in order to decrease the heart rate by 20%. The following data were recorded at hours H0 (before esmolol administration), H1-H6 (esmolol administration) and 1 h after esmolol cessation (H7): systolic arterial pressure, diastolic arterial pressure, mean arterial pressure, central venous pressure, heart rate, PICCO transpulmonary thermodilution, sublingual and musculo-cutaneous microcirculation, indocyanine green clearance and echocardiographic parameters, diuresis, lactate, and arterial and venous blood gases. RESULTS: Esmolol was infused 9 (6.4-11.6) hours after norepinephrine introduction. Esmolol was ceased early in 3 out of 9 patients due to a marked increase in norepinephrine requirement associated with a picture of persistent cardiac failure at the lowest esmolol dose. For the global group, during esmolol infusion, norepinephrine infusion increased from 0.49 (0.34-0.83) to 0.78 (0.3-1.11) µg/min/kg. The use of esmolol was associated with a significant decrease in heart rate from 115 (110-125) to 100 (92-103) beats/min and a decrease in cardiac index from 4.2 (3.1-4.4) to 2.9 (2.5-3.7) l/min/m-2. Indexed stroke volume remained unchanged. Cardiac function index and global ejection fraction also markedly decreased. Using echocardiography, systolic, diastolic as well as left and right ventricular function parameters worsened. After esmolol cessation, all parameters returned to baseline values. Lactate and microcirculatory parameters did not change while the majority of pro-inflammatory proteins decreased in all patients. CONCLUSION: In the very early phase of septic shock, heart rate reduction using fast esmolol titration is associated with an increased risk of hypotension and decreased cardiac index despite maintained adequate tissue perfusion (NCT02068287).


Assuntos
Hemodinâmica/efeitos dos fármacos , Propanolaminas/farmacologia , Choque Séptico/tratamento farmacológico , Fatores de Tempo , Adulto , Idoso , Idoso de 80 Anos ou mais , Anti-Inflamatórios/farmacologia , Anti-Inflamatórios/uso terapêutico , Débito Cardíaco/efeitos dos fármacos , Ecocardiografia/métodos , Feminino , França , Frequência Cardíaca/efeitos dos fármacos , Humanos , Verde de Indocianina/análise , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Norepinefrina/administração & dosagem , Norepinefrina/classificação , Projetos Piloto , Propanolaminas/uso terapêutico , Choque Séptico/fisiopatologia , Espectrofotometria Infravermelho/métodos , Vasoconstritores/administração & dosagem , Vasoconstritores/classificação
5.
J Cancer Res Clin Oncol ; 147(6): 1813-1823, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33230583

RESUMO

PURPOSE: The usage of radioactive Technetium99m (Tc99m) colloid for the purpose of sentinel lymph node biopsy (SLNB) in early breast cancer is considered the gold standard in Germany. However, new tracers, such as near-infrared (NIR) imaging agents like indocyanine green (ICG) could offer an alternative in future, as they overcome drawbacks associated with radioactive Technetium99m (Tc99m) like limited availability, high costs and radioactivity exposure for both patients and surgeons. METHODS: In this double-arm retrospective study, we sought to establish the usefulness of indocyanine green as an alternative or an addition to the conventional Technetium99m (Tc99m) in the identification of the SLN in early breast cancer. RESULTS: Among the 161 patients who underwent primary SLNB, 34 patients had at least 1 SLN with metastasis. Among these patients with SLN metastasis, 33 had the SLN detected by ICG; while 31 had the SLN detected by Tc99m. The conventional Technetium99m radiotracer failed to detect 2 patients with metastasis in this Arm of the study. Among the 87 patients who underwent SLNB after NACT, 13 patients had at least 1 SLN with metastasis. Among these 13 patients with SLN metastasis, ICG and Tc99m had detected the SLN among 12 patients, while 1 patient had been detected by ICG alone. CONCLUSIONS: Our results show that ICG is as effective as the radioisotope for SLNB even among patients who have undergone NACT. This trial is registered with the German Clinical Trial Register, ID: DRKS00013606.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/farmacologia , Neoplasias da Mama/patologia , Biópsia de Linfonodo Sentinela , Linfonodo Sentinela/efeitos dos fármacos , Linfonodo Sentinela/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Corantes/análise , Corantes/farmacocinética , Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/métodos , Feminino , Fluorescência , Humanos , Verde de Indocianina/análise , Verde de Indocianina/farmacocinética , Metástase Linfática , Pessoa de Meia-Idade , Terapia Neoadjuvante , Imagem Óptica/instrumentação , Imagem Óptica/métodos , Valor Preditivo dos Testes , Estudos Retrospectivos , Linfonodo Sentinela/metabolismo , Linfonodo Sentinela/patologia , Biópsia de Linfonodo Sentinela/instrumentação , Biópsia de Linfonodo Sentinela/métodos , Tecnécio/análise , Tecnécio/farmacocinética
6.
Chem Pharm Bull (Tokyo) ; 69(1): 118-123, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33087642

RESUMO

Quantitative NMR (qNMR) is applied to determine the absolute quantitative value of analytical standards for HPLC-based quantification. We have previously reported the optimal and reproducible sample preparation method for qNMR of hygroscopic reagents, such as saikosaponin a, which is used as an analytical standard in the assay of crude drug section of Japanese Pharmacopoeia (JP). In this study, we examined the absolute purity determination of a hygroscopic substance, indocyanine green (ICG), listed in the Japanese Pharmaceutical Codex 2002, using qNMR for standardization by focusing on the adaptation of ICG to JP. The purity of ICG, as an official non-Pharmacopoeial reference standard (non-PRS), had high variation (86.12 ± 2.70%) when preparing qNMR samples under non-controlled humidity (a conventional method). Additionally, residual ethanol (0.26 ± 0.11%) was observed in the non-PRS ICG. Next, the purity of non-PRS ICG was determined via qNMR when preparing samples under controlled humidity using a saturated sodium bromide solution. The purity was 84.19 ± 0.47% with a lower variation than that under non-controlled humidity. Moreover, ethanol signal almost disappeared. We estimated that residual ethanol in non-PRS ICG was replaced with water under controlled humidity. Subsequently, qNMR analysis was performed when preparing samples under controlled humidity in a constant temperature and humidity box. It showed excellent results with the lowest variation (82.26 ± 0.19%). As the use of a constant temperature and humidity box resulted in the lowest variability, it is recommended to use the control box if the reference ICG standard is needed for JP assays.


Assuntos
Verde de Indocianina/análise , Espectroscopia de Ressonância Magnética , Estrutura Molecular , Molhabilidade
7.
J Mater Chem B ; 8(46): 10602-10608, 2020 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-33136101

RESUMO

Melanoma are malignant tumors derived from melanocytes being responsible for the majority of skin cancer deaths with an increasing rate of incidence. The Melanocortin-1 receptor (MC1R) has been recognized as a molecular target for melanoma detection. Here, we report on the development and optimization of molecular probes which are based on novel conjugates of near-infrared (NIR) fluorescent indocyanine dyes and an MC1R-targeting peptide intended for optical fluorescence imaging enabling an early, specific, accurate and sensitive diagnosis of malignant melanomas. The introduction of anionic groups into the aromatic ring of the indolenine substructure of the conjugated dyes has shown to result in a strong fluorescence in aqueous solution and a concomitant increase of binding affinities of the peptide conjugates to the target receptor. The length and flexibility of the PEG chain introduced as a linker, as well as the nature of its attachment to the dye also affect the binding affinities, albeit to a lower extent. The conjugates have been successfully applied in the MC1R-specific staining of B16F10 melanoma cells, both in cell cultures and in microtome sections of solid tumors.


Assuntos
Diagnóstico por Imagem/métodos , Corantes Fluorescentes/síntese química , Melanoma/diagnóstico por imagem , Receptor Tipo 1 de Melanocortina/análise , Neoplasias Cutâneas/diagnóstico por imagem , Animais , Corantes Fluorescentes/metabolismo , Humanos , Verde de Indocianina/análise , Verde de Indocianina/metabolismo , Melanoma/metabolismo , Melanoma Experimental , Camundongos , Camundongos Nus , Ligação Proteica/fisiologia , Receptor Tipo 1 de Melanocortina/metabolismo , Neoplasias Cutâneas/metabolismo , Espectroscopia de Luz Próxima ao Infravermelho/métodos
8.
IEEE J Biomed Health Inform ; 24(12): 3520-3528, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32750947

RESUMO

Retinal pigment epithelial (RPE) cells play an important role in nourishing retinal neurosensory photoreceptor cells, and numerous blinding diseases are associated with RPE defects. Their fluorescence signature can now be visualized in the living human eye using adaptive optics (AO) imaging combined with indocyanine green (ICG), which motivates us to develop an automated RPE detection method to improve the quantitative evaluation of RPE status in patients. This paper proposes a spatially-aware, Dense-LinkNet-based regression approach to improve the detection of in vivo fluorescent cell patterns, achieving precision, recall, and F1-Score of 93.6 ± 4.3%, 81.4 ± 9.5%, and 86.7 ± 5.7%, respectively. These results demonstrate the utility of incorporating spatial inputs into a deep learning-based regression framework for cell detection.


Assuntos
Aprendizado Profundo , Corantes Fluorescentes , Processamento de Imagem Assistida por Computador/métodos , Imagem Óptica/métodos , Epitélio Pigmentado da Retina , Técnicas de Diagnóstico Oftalmológico , Corantes Fluorescentes/análise , Corantes Fluorescentes/química , Humanos , Verde de Indocianina/análise , Epitélio Pigmentado da Retina/citologia , Epitélio Pigmentado da Retina/diagnóstico por imagem
9.
Ann Thorac Surg ; 110(5): e385-e386, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32360873

RESUMO

Currently there is no explicit guideline for the use of indocyanine green (ICG) in the localization of pulmonary nodules before surgery. How long ICG can remain in vivo is unknown. According to previous reports, ICG can be observed under infrared thoracoscope within 24 hours after injection. We unexpectedly found a case of a 54-year-old man who was injected with ICG under CT guidance, which was still clearly visible under infrared thoracoscopy after 6 days. This unexpected finding suggests that the operation time can be arranged appropriately after local injection with ICG.


Assuntos
Verde de Indocianina/análise , Pulmão/química , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Tomografia Computadorizada por Raios X
10.
Transplant Proc ; 52(5): 1397-1398, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32461006

RESUMO

Since the beginning of the history of transplants, numerous difficulties have been faced in the effective implementation of this therapeutic practice, especially with regard to the transplantation of solid organs and their teaching and training, together with the time of removal and transplantation of the organ that directly influences the results of the transplant surgical procedure. The objective of this research was to demonstrate the results found on the process of using green indocyanine during the invention of the Automatic Portable Surgical Communication Equipment with the Robot R1T1 (APSCERR), as well as to demonstrate its capabilities in the medical area of organ transplantation. Biochemical exams, liver profile exams, and mitochondrial breathing exams were performed on the control group and on the indocyanine group. The Mann-Whitney U test was used for statistical evaluations with a significance level of P < .05. As a result of this research, the effectiveness of using the APSCERR equipment on detecting the green indocyanine marker was proven, along with its ability to analyze macroscopic parameters together with the standard color "Dianin Boin scale" used to analyze the level of metabolism/reperfusion of the liver when observed with the APSCERR equipment connected to the R1T1 robot in the presence of green indocyanine. A patent for the development of APSCERR has been registered. It was possible to demonstrate the effectiveness of the equipment in detecting green indocyanine when analyzing parameters in the liver and the absence of a significant impact on the organ with the use of green indocyanine.


Assuntos
Verde de Indocianina/metabolismo , Testes de Função Hepática/instrumentação , Transplante de Fígado/métodos , Robótica/instrumentação , Robótica/métodos , Animais , Humanos , Verde de Indocianina/análise , Fígado/metabolismo , Testes de Função Hepática/métodos , Masculino , Ratos , Ratos Wistar , Transplantes/metabolismo
11.
J Neurosurg ; 134(5): 1544-1552, 2020 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-32442970

RESUMO

OBJECTIVE: Although intravenous indocyanine green (ICG) videoangiography has been reported to be useful when applied to cerebral arteriovenous malformation (AVM) surgery, the ICG that remains after the procedure makes it difficult to understand the anatomy, to evaluate nidus blood flow changes, and to repeat ICG videoangiography within a short time. Intraarterial ICG videoangiography has emerged as a way to overcome these limitations. The current study presents the results of intraarterial ICG videoangiography undertaken in patients with cerebral AVMs. METHODS: Intraarterial ICG videoangiography was performed in 13 patients with cerebral AVMs. Routine intraoperative digital subtraction angiography at the authors' institution is performed in a hybrid operating room during AVM surgery and includes the added step of injecting ICG to the contrast medium that is administered through a catheter. RESULTS: Predissection studies were able to visualize the feeder in 12 of 13 cases. The nidus was visualized in 12 of 13 cases, while the drainer was visualized in all cases. After total dissection of the nidus, there was no ICG filling in the drainers found in any of the cases. Washout of the ICG took 4.4 ± 1.3 seconds in the feeders, 9.2 ± 3.5 seconds in the drainers, and 20.9 ± 3.4 seconds in all of the vessels. Nidus flow reduction was confirmed during dissection in 9 of 9 cases. Flow reduction was easy to recognize due to each span being very short. Color-encoded visualization and objective data obtained by Flow 800 analysis reinforced these findings. CONCLUSIONS: The results showed that intraarterial ICG videoangiography was more useful than intravenous ICG videoangiography in cerebral AVM surgery. This was especially effective in the identification of the feeder, nidus, and drainer and in the assessment of the flow dynamics of the nidus. Use of Flow 800 made it simpler and easier to evaluate these findings.


Assuntos
Angiografia Cerebral/métodos , Corantes Fluorescentes/análise , Verde de Indocianina/análise , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Salas Cirúrgicas , Gravação em Vídeo/métodos , Adolescente , Adulto , Angiografia Digital/métodos , Cateterismo , Meios de Contraste/administração & dosagem , Feminino , Corantes Fluorescentes/administração & dosagem , Humanos , Achados Incidentais , Verde de Indocianina/administração & dosagem , Injeções Intra-Arteriais , Malformações Arteriovenosas Intracranianas/cirurgia , Masculino , Pessoa de Meia-Idade , Cirurgia Assistida por Computador , Adulto Jovem
12.
Int J Biol Sci ; 16(9): 1616-1628, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32226306

RESUMO

Rationale:In vivo molecular imaging in preclinical animal models is a tool of choice for understanding the pathophysiological mechanisms involved in cancer development and for conducting drug development research. Moreover, combining several imaging modalities can provide multifaceted, complementary and cross-validated information. Photoacoustic imaging (PAI) is a promising imaging modality that can reflect blood vasculature and tissue oxygenation as well as detect exogenous molecules, but one shortcoming of PAI is a lack of organic photoacoustic contrast agents capable of providing tumor contrast. Methods: In the present study, we designed an animal model of liver metastases from colon cancer and monitored metastasis development by in vivo bioluminescence and X-ray microcomputed tomography. Contrast-agent-free PAI was used to detect the respective amounts of oxy- and deoxyhemoglobin and, thus, liver tissue oxygenation. two contrast agents, Angiostamp800 and indocyanin green (ICG), respectively with and without tumor targeting specificity, were then evaluated for their dual fluorescence and photoacoustic detectability and were then used for combined PAI and fluorescence diffuse optical tomography (fDOT) at various disease development stages. Findings: Contrast-agent-free PAI reflected tumor angiogenesis and gradual hypoxia during metastasis development. Multispectral PAI enabled noninvasive real-time monitoring of ICG blood pharmacokinetics, which demonstrated tumor-related liver dysfunction. Both PAI and fluorescence ICG signals were clearly modified in metastasis-bearing livers but did not allow for differentiation between different disease stages. In contrast, there was a significant improvement achieved by using the tumor-specific marker Angiostamp800, which provided gradually increasing PAI and fDOT signals during metastasis development. Conclusion: We demonstrated for the first time the value of using Angiostamp800 as a bimodal tumor-targeting contrast agent for combined PAI and fluorescence imaging of liver metastasis progression in vivo.


Assuntos
Meios de Contraste , Neoplasias Hepáticas/secundário , Técnicas Fotoacústicas , Tomografia Óptica , Animais , Linhagem Celular Tumoral , Neoplasias do Colo/patologia , Meios de Contraste/análise , Meios de Contraste/farmacocinética , Feminino , Corantes Fluorescentes/análise , Corantes Fluorescentes/farmacocinética , Humanos , Verde de Indocianina/análise , Verde de Indocianina/farmacocinética , Fígado/metabolismo , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/metabolismo , Camundongos Nus
13.
Theranostics ; 10(7): 3340-3350, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32194872

RESUMO

Lymph node (LN) dissection followed by histological analysis is the current standard for diagnosis of LN metastasis but the method suffers from patient morbidity and low sensitivity of detection. Ultra-pH sensitive (UPS) nanoparticles show remarkable accuracy in the delineation of primary tumor margins for precision cancer surgery. Herein we investigate the effectiveness of UPS nanoparticles to detect cancer-involved LNs. Methods: We synthesized a series of indocyanine green (ICG) conjugated UPS nanoparticles with distinct pKa (UPS5.3, UPS6.1, and UPS6.9). Systemically administered UPS-ICG nanoparticles in the 4T1.2-BALB/cj mouse model were imaged with real-time, near-infrared fluorescence (NIRF) to guide removal of LNs. Ex vivo imaging of gross tissue enabled quantification of fluorescence intensity. Histological analysis was used as the gold standard diagnostic test. Results: Macrophage uptake of UPS nanoparticles elevates the background signal in benign LNs. However, cancer foci within LNs show distinctive clustering of UPS-ICG fluorescence. UPS5.3 achieves accurate detection of metastatic LNs as shown by a receiver operating characteristic (ROC) area under the curve (AUC) of 0.96 ± 0.03. UPS6.1 and UPS6.9 offer decreased discriminatory power at ROC AUC of 0.73 ± 0.1 and 0.88 ± 0.07, respectively. Conclusions: All UPS compositions show cancer-specific discrimination of metastatic LNs over benign LNs with the best outcomes from UPS5.3. Detection of micro-metastatic LNs (cancer foci < 2 mm) remains a challenge. This study provides information on the detection of LN status for image-guided resection of metastatic LNs.


Assuntos
Verde de Indocianina/análise , Metástase Linfática/diagnóstico por imagem , Macrófagos/fisiologia , Nanopartículas/análise , Acidose , Animais , Área Sob a Curva , Sistemas Computacionais , Difusão Dinâmica da Luz , Feminino , Fluorometria , Concentração de Íons de Hidrogênio , Verde de Indocianina/administração & dosagem , Excisão de Linfonodo , Linfonodos/citologia , Neoplasias Mamárias Experimentais , Camundongos , Camundongos Endogâmicos BALB C , Micelas , Nanopartículas/química , Fagocitose , Curva ROC , Cirurgia Assistida por Computador , Macrófagos Associados a Tumor/fisiologia
14.
Transplant Proc ; 52(5): 1336-1339, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32178927

RESUMO

BACKGROUND: Liver transplantation (LT) has evolved to improve graft and patient survival. Early graft dysfunction (EGD) and primary nonfunction are an important cause of morbi-mortality. We had formulated the scientific hypothesis that the liver function can be evaluated by the indocyanine green (IG) after LT. The aim was to evaluate the EGD by plasma disappearance rate (PDR) of IG after LT. METHOD: Prospective and observational clinical study, from July 2014 to June 2015. IG evaluation by pulse densitometry, Limon system. Degree analysis of ischemia and reperfusion injury in groups as follows: 1 (G0/G1/G2) and 2 (G3/G4). Donor risk index (DRI), Wagener and Olthoff criteria, and prognostic predictors were evaluated. All tests were performed with bidirectional α of 0.05 and a confidence interval of 95% and support by IBM SPSS 25. RESULTS: A total of 40 patients, mean age 53.3 ± 14.0 years and a majority of men and hepatitis C virus. PDR were more relevant with high degrees of ischemia and reperfusion injury grades G3/G4 (P = .030). The PDR related to the donor risk index showed positive significance at DRI >1.5 (P = .066). The retention rate of IG at 15 minutes demonstrated potential in assessing graft loss or death (P = .063). CONCLUSION: EGD can be assessed by PDR with high degrees of ischemia and reperfusion injury (G3/G4) and with marginal donors (DRI >1.5). The retention rate of IG at 15 minutes demonstrated potential in assessing graft loss or death of the patient.


Assuntos
Verde de Indocianina , Testes de Função Hepática/métodos , Transplante de Fígado , Disfunção Primária do Enxerto/diagnóstico , Traumatismo por Reperfusão/diagnóstico , Adulto , Idoso , Feminino , Humanos , Verde de Indocianina/análise , Verde de Indocianina/metabolismo , Transplante de Fígado/mortalidade , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Prognóstico , Estudos Prospectivos , Traumatismo por Reperfusão/etiologia , Resultado do Tratamento
15.
IEEE Trans Med Imaging ; 39(4): 944-951, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31478842

RESUMO

Recently, fluorescence imaging using shortwave infrared light (SWIR, 1,000-2,000 nm) has been proposed as having advantage over conventional near-infrared fluorescence (NIRF) imaging due to the reduced tissue scattering, negligible autofluorescence, comparable tissue absorption, and the discovery that indocyanine green (ICG), used clinically as a NIRF contrast agent, also has fluorescence emission in SWIR regime. Images of ICG in small animals acquired by commercial Si-based and InGaAs-based imaging cameras have been qualitatively compared, however the lack of working standards to quantify performance of these imaging systems limits quantitative comparison. Without quantification using a traceable in vitro test, clinical adoption of rapidly evolving advances in both NIRF and SWIR imaging devices will become limited. In this work, we developed an ICG based fluorescent solid working standard calibrated with SI units (mW [Formula: see text]cm [Formula: see text]sr -1) for quantification of measurement sensitivity of Si, GaAs-intensified Si, and InGaAs based camera systems, their signal-to-noise ratio (SNR), and contrast in non-clinical tests. In addition, we present small animal and large animal imaging with ICG for qualitative comparison of the same SWIR fluorescence and NIRF imaging systems. Results suggest that SWIR fluorescence imaging of ICG may have superior resolution in small animal imaging compared to NIRF imaging, but lack of measurement sensitivity, SNR, contrast, as well as water absorption limits deep penetration in large animals.


Assuntos
Imagem Óptica/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Animais , Calibragem , Verde de Indocianina/análise , Verde de Indocianina/química , Camundongos , Imagem Molecular , Imagem Óptica/normas , Imagens de Fantasmas , Padrões de Referência , Espectroscopia de Luz Próxima ao Infravermelho/normas
16.
Sci Transl Med ; 11(507)2019 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-31462508

RESUMO

Imaging technologies that simultaneously provide anatomical, functional, and molecular information are emerging as an attractive choice for disease screening and management. Since the 1980s, transrectal ultrasound (TRUS) has been routinely used to visualize prostatic anatomy and guide needle biopsy, despite limited specificity. Photoacoustic imaging (PAI) provides functional and molecular information at ultrasonic resolution based on optical absorption. Combining the strengths of TRUS and PAI approaches, we report the development and bench-to-bedside translation of an integrated TRUS and photoacoustic (TRUSPA) device. TRUSPA uses a miniaturized capacitive micromachined ultrasonic transducer array for simultaneous imaging of anatomical and molecular optical contrasts [intrinsic: hemoglobin; extrinsic: intravenous indocyanine green (ICG)] of the human prostate. Hemoglobin absorption mapped vascularity of the prostate and surroundings, whereas ICG absorption enhanced the intraprostatic photoacoustic contrast. Future work using the TRUSPA device for biomarker-specific molecular imaging may enable a fundamentally new approach to prostate cancer diagnosis, prognostication, and therapeutic monitoring.


Assuntos
Técnicas Fotoacústicas/métodos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Ultrassonografia/métodos , Animais , Meios de Contraste/análise , Humanos , Verde de Indocianina/análise , Masculino , Camundongos , Camundongos Nus , Estudos Prospectivos
17.
Med Biol Eng Comput ; 57(9): 1889-1900, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31243624

RESUMO

Most common complications of esophagectomy stem from a perfusion deficiency of the gastric conduit at the anastomosis. Fluorescent tracer imaging allows intraoperative visualization of tissue perfusion. Quantitative assessment of fluorescence dynamics has the potential to identify perfusion deficiency. We developed a perfusion model to analyze the relation between fluorescence dynamics and perfusion deficiency. The model divides the gastric conduit into two well-perfused and two anastomosed sites. Hemodynamics and tracer transport were modeled. We analyzed the value of relative time-to-threshold (RTT) as a predictor of the relative remaining flow (RRF). Intensity thresholds for RTT of 20% to 50% of the maximum fluorescence intensity of the well-perfused site were tested. The relation between RTT and RRF at the anastomosed sites was evaluated over large variations of vascular conductance and volume. The ability of RTT to distinguish between sufficient and impaired perfusion was analyzed using c-statistics. We found that RTT was a valuable estimate for low RRF. The threshold of 20% of the maximum fluorescence intensity provided the best prediction of impaired perfusion on the two anastomosed sites (AUC = 0.89 and 0.86). The presented model showed that for low flows, relative time-to-threshold may be used to estimate perfusion deficiency.


Assuntos
Esofagectomia , Corantes Fluorescentes/análise , Microvasos/fisiologia , Modelos Biológicos , Anastomose Cirúrgica , Humanos , Verde de Indocianina/análise , Imagem Óptica/métodos , Perfusão , Fluxo Sanguíneo Regional , Fatores de Tempo
18.
J Fr Ophtalmol ; 42(7): 690-695, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31164300

RESUMO

PURPOSE: To compare optical coherence tomography angiography (OCTA) and indocyanine green angiography (ICGA) findings in polypoidal choroidal vasculopathy (PCV) according to polyp type, polyp size and pigment epithelial detachment (PED) size. METHOD: Seventeen patients with PCV were included this study. The participants were divided into two groups according to ICGA images. Participants who had type I PCV formed group 1, and group 2 was comprised of patients with type II PCV. OCTA was performed for all participants. Polyp detection rates with OCTA and factors affecting this detection were assessed. RESULTS: The mean age of all patients was 68.85±4.77 years (group 1 70.4±2.54 years, group 2 67.45±5.93 years). The rate of polyps seen in OCTA images was statistically significantly correlated with polyp type, polyp size, and PED size (r=0.633, p=0.002; r=0.64, P=0.001 and r=0.59, p<0.001, respectively). In group 1, the mean polyp size was 230.8±82.94µm, and the mean PED size was 161.3±73.87µm. In group 1, 10 patients with PCV were detected with ICGA, while only 1 (10%) PCV was detected with OCTA. In group 2, the mean polyp size was 387.90±245.90µm, and the mean PED size was 345.18±276.26µm. In group 2, 11 patients with PCV were detected with ICGA, while 8 (72.7%) of these patients were detected using OCTA. CONCLUSIONS: OCTA showed a greater percentage of detection of type II PCV than type I PCV. Polyp and PED size are important for the detection of PCV using OCTA.


Assuntos
Doenças da Coroide/diagnóstico , Neovascularização de Coroide/diagnóstico , Angiofluoresceinografia/métodos , Pólipos/diagnóstico , Tomografia de Coerência Óptica/métodos , Idoso , Idoso de 80 Anos ou mais , Neovascularização de Coroide/complicações , Corantes/análise , Feminino , Humanos , Verde de Indocianina/análise , Masculino , Pessoa de Meia-Idade , Pólipos/complicações , Estudos Prospectivos
19.
BMC Infect Dis ; 19(1): 473, 2019 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-31138261

RESUMO

BACKGROUND: Leptospirosis is one of the leading global zoonotic causes of morbidity and mortality. It is induced by a pathogenic spirochete of the genus Leptospira. The icteric form of leptospirosis is characterized by pronounced hyperbilirubinemia and associated with significantly increased mortality. Conventional static liver function tests insufficiently assess hepatic damage and have limited prognostic value. Dynamic tests, such as indocyanine green plasma (ICG) clearance, more adequately reflect hepatic functional status. In this case report we describe the ICG plasma disappearance rates (ICG-PDR) in a patient with leptospirosis and massive hyperbilirubinemia, expanding our knowledge of liver dysfunction in icteric leptospirosis. CASE PRESENTATION: A 21-year-old Caucasian man presented with acute-onset jaundice, myalgia, fever and headaches. Laboratory tests upon admission revealed, most notably, acute kidney failure and hyperbilirubinemia of 17 mg/dl with mild elevation of aminotransferases. In the course of the following 4 days, total serum bilirubin increased to 54 mg/dl. The clinical outcome was favorable with intravenous ceftriaxone and doxycycline. Presumptive diagnosis of leptospirosis was later confirmed by PCR-based amplification of leptospiral DNA in the blood. ICG-PDR values, bilirubin as well as aminotransferases were recorded throughout hospitalization and a 3-month follow-up period. Initially dramatically reduced ICG-PDR (2.0%/min, normal range: 18-25%/min) rapidly normalized within 10 days, while bilirubin remained elevated up to week 7. Mild elevation of serum alanine aminotransferase was at its peak of 124 U/l by day 12 and reached close to normal levels by week 7 upon admission. CONCLUSIONS: Markedly diminished ICG-PDR values presented in this case report suggest severe liver function impairment in the acute phase of icteric leptospirosis. Prolonged elevation of serum bilirubin may not adequately reflect recovery of liver injury in this disease. ICG clearance appears to be a promising marker for the detection of hepatic dysfunction and recovery in icteric leptospirosis in addition to the static tests.


Assuntos
Verde de Indocianina/farmacocinética , Leptospirose/fisiopatologia , Hepatopatias/diagnóstico , Testes de Função Hepática/métodos , Alanina Transaminase/sangue , Ceftriaxona/uso terapêutico , Corantes/análise , Corantes/farmacocinética , Doxiciclina/uso terapêutico , Humanos , Hiperbilirrubinemia/fisiopatologia , Verde de Indocianina/análise , Leptospirose/tratamento farmacológico , Hepatopatias/sangue , Masculino , Adulto Jovem
20.
Sci Rep ; 9(1): 6149, 2019 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-30992527

RESUMO

The purpose of this article is to compare optical coherence tomography angiography (OCTA) and indocyanine green angiography (ICGA) in patients with central serous chorioretinopathy (CSC). OCTA, ICGA and fluorescein angiography (FA) images of all enrolled patients were collected and compared. Abnormal areas were annotated on en face choriocapillaris OCTA and ICGA images and compared with each other. We found three main types of anomalies in choriocapillaris OCTA images: type A, coarse granulated high reflective area (61 eyes [92.4%]); type B, roundish dark halo around Type A (54 eyes [81.8%]); and type C, coarse granulated low reflective area (66 eyes [100%]). There were 54 eyes (81.8%) that exhibited all three types abnormalities, 7 (10.6%) had only type A and C abnormalities, and 5 (7.6%) had only type C abnormalities. The Mean JI of type A on OCTA and hyperfluorescence area on ICGA was 0.84 ± 0.15 and 0.82 ± 0.23 for grader 1 and 2, respectively. Type A area on OCTA had a statistically larger area than hyperfluorescence on ICGA (P = 0.01 [paired t-test]). In summary, abnormalities were found on OCTA images of CSC. Coarse granulated high reflective area in OCTA corresponded well with the hyper-permeability area in ICGA in most of the eyes.


Assuntos
Coriorretinopatia Serosa Central/diagnóstico por imagem , Corioide/diagnóstico por imagem , Adulto , Angiografia/métodos , Feminino , Angiofluoresceinografia/métodos , Humanos , Verde de Indocianina/análise , Masculino , Pessoa de Meia-Idade , Tomografia de Coerência Óptica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA