Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.218
Filtrar
1.
J Nucl Cardiol ; 36: 101867, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38697386

RESUMO

BACKGROUND: The segment of the latest mechanical contraction (LMC) does not always overlap with the site of the latest electrical activation (LEA). By integrating both mechanical and electrical dyssynchrony, this proof-of-concept study aimed to propose a new method for recommending left ventricular (LV) lead placements, with the goal of enhancing response to cardiac resynchronization therapy (CRT). METHODS: The LMC segment was determined by single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) phase analysis. The LEA site was detected by vectorcardiogram. The recommended segments for LV lead placement were as follows: (1) the LMC viable segments that overlapped with the LEA site; (2) the LMC viable segments adjacent to the LEA site; (3) If no segment met either of the above, the LV lateral wall was recommended. The response was defined as ≥15% reduction in left ventricular end-systolic volume (LVESV) 6-months after CRT. Patients with LV lead located in the recommended site were assigned to the recommended group, and those located in the non-recommended site were assigned to the non-recommended group. RESULTS: The cohort comprised of 76 patients, including 54 (71.1%) in the recommended group and 22 (28.9%) in the non-recommended group. Among the recommended group, 74.1% of the patients responded to CRT, while 36.4% in the non-recommended group were responders (P = .002). Compared to pacing at the non-recommended segments, pacing at the recommended segments showed an independent association with an increased response by univariate and multivariable analysis (odds ratio 5.00, 95% confidence interval 1.73-14.44, P = .003; odds ratio 7.33, 95% confidence interval 1.53-35.14, P = .013). Kaplan-Meier curves showed that pacing at the recommended LV lead position demonstrated a better long-term prognosis. CONCLUSION: Our findings indicate that pacing at the recommended segments, by integrating of mechanical and electrical dyssynchrony, is significantly associated with an improved CRT response and better long-term prognosis.


Assuntos
Terapia de Ressincronização Cardíaca , Ventrículos do Coração , Vetorcardiografia , Humanos , Terapia de Ressincronização Cardíaca/métodos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Vetorcardiografia/métodos , Resultado do Tratamento , Ventrículos do Coração/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Imagem de Perfusão do Miocárdio/métodos , Estudo de Prova de Conceito , Tomografia Computadorizada de Emissão de Fóton Único , Dispositivos de Terapia de Ressincronização Cardíaca
2.
J Electrocardiol ; 84: 81-87, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38574634

RESUMO

BACKGROUND: Precordial Bipolar Leads (PBLs) provide new electrocardiographic information derived from standard 12­lead ECG recordings. OBJECTIVES: To explore the usefulness of PBLs in patients with acute circumflex coronary artery (CxCA) occlusion. METHODS: Twelve patients undergoing elective percutaneous transluminal coronary angioplasty (PTCA) were studied before and after acute CxCA occlusion and their data were processed with new methods based on PBLs. RESULTS: The findings were: 1. In right PBL V2-V1, a strong systolic current of injury moving in the left-to-right direction coexists with a strong right-to-left current of injury displayed in left standard unipolar precordial leads (V4, V5 and V6). 2. Ischemic changes lead to a significant increase (approximately 10 ms) in the QRS duration in different leads, although changes in the QRS loop rotation and folding were absent. 3. In the transverse, sagittal, and frontal planes, superimposing two PBLs and the corresponding Regional VCG facilitates the location of the J-point. 4. In the Regional VCGs of this group of patients, J-point and ST segment shifts produced an image that reminds the Greek letter omega (Ω). 5. The currents of injury flowing in opposite directions could result in electrical cancellation that minimizes ECG changes in the standard 12­lead recordings. CONCLUSIONS: Computerized processing of digital, standard 12­lead ECG recordings, provides new valuable diagnostic data in patients with acute CxCA occlusion. The loops revealed important information related to systolic currents of injury. Because these methods use routine 12­lead ECG data, the procedure is based only in software applications. CONDENSED ABSTRACT: Twelve patients undergoing PTCA were studied before and after acute CxCA occlusion and their data were processed with the new methods based on Precordial Bipolar Leads (PBLs) to explore their usefulness. The results showed strong systolic currents of injury in different and sometimes opposite directions in the right-to-left axis and ischemic alterations in the time and amplitude of the QRS waves. The superimposition of two-dimensional coordinates planes (x-y, x-z or z-y) helped to locate the J-point and to display the Regional VCG omega sign (Ω) of myocardial injury. In conclusion, computerized processing of digital ECG data provides new diagnostic information in patients with acute CxCA occlusion.


Assuntos
Vetorcardiografia , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Vetorcardiografia/métodos , Reprodutibilidade dos Testes , Idoso , Sensibilidade e Especificidade , Ventrículos do Coração/fisiopatologia , Eletrodos , Eletrocardiografia , Diagnóstico por Computador/métodos
3.
Pacing Clin Electrophysiol ; 47(7): 974-976, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38529807

RESUMO

3DQRSarea is a strong marker for cardiac resynchronization therapy and can be obtained by taking the (i) summation or the (ii) difference of the areas subtended by positive and negative deflections in X, Y, Z vectorcardiographic electrocardiogram (ECG) leads. We correlated both methods with the instantaneous-absolute-3D-voltage-time-integral (VTIQRS-3D). 3DQRSarea consistently underestimated the VTIQRS -3D, but the summation method was a closer and more reliable approximation. The dissimilarity was less apparent in left bundle branch block (r2 summation .996 vs. difference .972) and biventricular paced ECGs (r2 .996 vs. .957) but was more apparent in normal ECGs (r2 .988 vs. .653).


Assuntos
Vetorcardiografia , Humanos , Vetorcardiografia/métodos , Terapia de Ressincronização Cardíaca/métodos , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Masculino , Eletrocardiografia/métodos , Reprodutibilidade dos Testes , Feminino , Sensibilidade e Especificidade , Diagnóstico por Computador/métodos , Algoritmos
4.
Nuklearmedizin ; 63(3): 213-218, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38378022

RESUMO

AIM: The present study evaluated with myocardial perfusion SPECT (MPS) the diagnostic accuracy of an artificial intelligence-enabled vectorcardiography system (Cardisiography, CSG) for detection of perfusion abnormalities. METHODS: We studied 241 patients, 155 with suspected CAD and 86 with known CAD who were referred for MPS. The CSG was performed after the MPS acquisition. The CSG results (1) p-factor (perfusion, 0: normal, 1: mildly, 2: moderately, 3: highly abnormal) and (2) s-factor (structure, categories as p-factor) were compared with the MPS scores. The CSG system was not trained during the study. RESULTS: Considering the p-factor alone, a specificity of >78% and a negative predictive value of mostly >90% for all MPS variables were found. The sensitivities ranged from 17 to 56%, the positive predictive values from 4 to 38%. Combining the p- and the s-factor, significantly higher specificity values of about 90% were reached. The s-factor showed a significant correlation (p=0.006) with the MPS ejection fraction. CONCLUSIONS: The CSG system is able to exclude relevant perfusion abnormalities in patients with suspected or known CAD with a specificity and a negative predictive value of about 90% combining the p- and the s-factor. Since it is a learning system there is potential for further improvement before routine use.


Assuntos
Inteligência Artificial , Imagem de Perfusão do Miocárdio , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único , Vetorcardiografia , Humanos , Imagem de Perfusão do Miocárdio/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Vetorcardiografia/métodos , Idoso , Reprodutibilidade dos Testes , Doença da Artéria Coronariana/diagnóstico por imagem , Doença das Coronárias/diagnóstico por imagem , Adulto
5.
IFMBE ; 99: 3-10, jan. 2024.
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1526932

RESUMO

ABSTRACT In medical practice, it is common to perform electrocardiography exams and by mathematical transformations to obtain the vectorcardiogram. The vectorcardiogram provides important information for medical diagnosis, such as the angle of inclination of the heart. This article aims to present a methodology for estimating the QRS vector-related angle of the heart using a posteroanterior chest radiograph image. We used an open source image processing software (Icy software version 2.3.0.0, Institut Pasteur, France, 2021) to perform a manual measurement of the target angle by analyzing relevant morphological structures from the x-ray images and using some functions to help the user to measure it. 18 radiographic images were selected to measure the angle of the heart by two independent individuals. The measured angles were compared using the mean absolute error (MAE). We then computed the QRS peak elevation angles of the vectorcardiogram (VCG) of the 57 patients collected at Dante Pazzanese Institute of Cardiology. In addition, an individual was randomly selected to measure a set of 57 radiographic images of these same patients. We performed the statistical treatments and the results suggested that the proposed manual method may be an alternative, viable and fast approach to estimating the anatomical heart axis for the purpose of aiding in medical diagnosis. However, further comparisons with more data and information are needed to determine its validity and possible method improvements.


Assuntos
Vetorcardiografia , Tórax/diagnóstico por imagem
6.
Comput Biol Med ; 169: 107781, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38103481

RESUMO

This article presents an overview of existing approaches to perform vectorcardiographic (VCG) diagnostics of ischemic heart disease (IHD). Individual methodologies are divided into categories to create a comprehensive and clear overview of electrical cardiac activity measurement, signal pre-processing, features extraction and classification procedures. An emphasis is placed on methods describing the electrical heart space (EHS) by several features extraction techniques based on spatiotemporal characteristics or signal modelling and signal transformations. Performance of individual methodologies are compared depending on classification of extent of ischemia, acute forms - myocardial infarction (MI) and myocardial scars localization. Based on a comparison of imaging methods, the advantages of VCG over the standard 12-leads ECG such as providing a 3D orthogonal leads imaging, better performance, and appropriate computer processing are highlighted. The issues of electrical cardiac activity measurements on body surface, the lack of VKG databases supported by a more accurate imaging method, possibility of comparison with the physiology of individual cases are outlined as potential reserves for future research.


Assuntos
Infarto do Miocárdio , Vetorcardiografia , Humanos , Vetorcardiografia/métodos , Coração/fisiologia , Miocárdio , Processamento de Sinais Assistido por Computador , Eletrocardiografia/métodos
7.
J Electrocardiol ; 82: 100-112, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38113771

RESUMO

BACKGROUND: The vectocardiogram (VCG) offers a three-dimensional view of the heart's electrical activity, yet many VCG parameters remain unexplored in diverse clinical contexts. OBJECTIVES: This study aims to explore the relationships between various VCG parameters and specific patient characteristics. METHODS: ECG signals from adults were transformed into VCGs utilizing the Kors matrix, yielding 315 parameters per patient from the P, QRS and T loops. Univariable analysis, circular statistics, and stepwise logistic regression were employed to examine the relationships between VCG parameters and factors such as age, sex, BMI, hypertension, echocardiographic ischemic heart disease (Echo-IHD), and left ventricular hypertrophy (Echo-LVH). RESULTS: We included 664 adults and considered an alpha value of 0.05 and a power of 90%. The study revealed significant associations, such as age with P loop roundness index (RI) (OR = 3.825, 95% confidence interval [95%CI] = 2.079-7.04), male sex with QRS loop RI (OR = 6.08, 95%CI = 1.835-20.153), abnormal BMI with the T loop's RI (OR = 0.544, 95%CI = 0.325-0.909), hypertension with the T loop planarity index (PI) (OR = 8.01, 95%CI = 2.134-30.117), Echo-IHD with QRS loop curvature at the 4/10th segment (OR = 7.58, 95%CI = 1.954-29.458), and Echo-LVH with the T loop lag-1/10 dihedral angle (OR = 10.3, 95%CI = 1.822-58.101). In the study, several additional VCG parameters demonstrated statistically significant, albeit smaller, associations with patient demographics and cardiovascular conditions. CONCLUSIONS: The findings enhance our understanding of the intricate relationships between VCG parameters and patient characteristics, emphasizing the potential role of VCG analysis in assessing cardiovascular diseases. These insights may guide future research and clinical applications in cardiology.


Assuntos
Doenças Cardiovasculares , Cardiopatias , Hipertensão , Isquemia Miocárdica , Adulto , Masculino , Humanos , Eletrocardiografia/métodos , Índice de Massa Corporal , Vetorcardiografia/métodos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem
9.
Comput Methods Programs Biomed ; 242: 107798, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37734217

RESUMO

BACKGROUND AND OBJECTIVES: Electrocardiographic (ECG) and vectorcardiographic (VCG) analyses are used to diagnose current cardiovascular disease and for risk stratification for future adverse cardiovascular events. With increasing use of digital ECGs, research into novel ECG/VCG parameters has increased, but widespread computer-based ECG/VCG analysis is limited because there are no currently available, open-source, and easily customizable software packages designed for automated and reproducible analysis. METHODS AND RESULTS: We present BRAVEHEART, an open-source, modular, customizable, and easy to use software package implemented in the MATLAB programming language, for scientific analysis of standard 12-lead ECGs acquired in a digital format. BRAVEHEART accepts a wide variety of digital ECG formats and provides complete and automatic ECG/VCG processing with signal denoising to remove high- and low-frequency artifact, non-dominant beat identification and removal, accurate fiducial point annotation, VCG construction, median beat construction, customizable measurements on median beats, and output of measurements and results in numeric and graphical formats. CONCLUSIONS: The BRAVEHEART software package provides easily customizable scientific analysis of ECGs and VCGs. We hope that making BRAVEHART available will allow other researchers to further the field of ECG/VCG analysis without having to spend significant time and resources developing their own ECG/VCG analysis software and will improve the reproducibility of future studies. Source code, compiled executables, and a detailed user guide can be found at http://github.com/BIVectors/BRAVEHEART. The source code is distributed under the GNU General Public License version 3.


Assuntos
Doenças Cardiovasculares , Vetorcardiografia , Humanos , Vetorcardiografia/métodos , Reprodutibilidade dos Testes , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Software , Doenças Cardiovasculares/diagnóstico
10.
Am J Physiol Heart Circ Physiol ; 325(6): H1279-H1289, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37773058

RESUMO

Congenital long QT syndrome (LQTS) carries an increased risk for syncope and sudden death. QT prolongation promotes ventricular extrasystoles, which, in the presence of an arrhythmia substrate, might trigger ventricular tachycardia degenerating into fibrillation. Increased electrical heterogeneity (dispersion) is the suggested arrhythmia substrate in LQTS. In the most common subtype LQT1, physical exercise predisposes for arrhythmia and spatiotemporal dispersion was therefore studied in this context. Thirty-seven patients (57% on ß-blockers) and 37 healthy controls (mean age, 31 vs. 35; range, 6-68 vs. 6-72 yr) performed an exercise test. Frank vectorcardiography was used to assess spatiotemporal dispersion as Tampl, Tarea, the ventricular gradient (VG), and the Tpeak-end interval from 10-s signal averages before and 7 ± 2 min after exercise; during exercise too much signal disturbance excluded analysis. Baseline and maximum heart rates as well as estimated exercise intensity were similar, but heart rate recovery was slower in patients. At baseline, QT and heart rate-corrected QT (QTcB) were significantly longer in patients (as expected), whereas dispersion parameters were numerically larger in controls. After exercise, QTpeakcB and Tpeak-endcB increased significantly more in patients (18 ± 23 vs. 7 ± 10 ms and 12 ± 17 vs. 2 ± 6 ms; P < 0.001 and P < 0.01). There was, however, no difference in the change in Tampl, Tarea, and VG between groups. In conclusion, although temporal dispersion of repolarization increased significantly more after exercise in patients with LQT1, there were no signs of exercise-induced increase in global dispersion of action potential duration and morphology. The arrhythmia substrate/mechanism in LQT1 warrants further study.NEW & NOTEWORTHY Physical activity increases the risk for life-threatening arrhythmias in LQTS type 1 (LQT1). The arrhythmia substrate is presumably altered electrical heterogeneity (a.k.a. dispersion). Spatiotemporal dispersion parameters were therefore compared before and after exercise in patients versus healthy controls using Frank vectorcardiography, a novelty. Physical exercise prolonged the time between the earliest and latest complete repolarization in patients versus controls, but did not increase parameters reflecting global dispersion of action potential duration and morphology, another novelty.


Assuntos
Síndrome do QT Longo , Síndrome de Romano-Ward , Humanos , Adulto , Eletrocardiografia , Síndrome do QT Longo/diagnóstico , Vetorcardiografia , Teste de Esforço , Ventrículos do Coração , Exercício Físico/fisiologia
11.
IEEE Trans Biomed Eng ; 70(3): 812-823, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36040933

RESUMO

OBJECTIVE: Myocardial infarction (MI) causes rapid and permanent damage to the heart muscle. Therefore, it can deteriorate the myocardial structure and function if not timely diagnosed and treated. However, it is difficult to determine the precise localization of MI based on vectorcardiogram (VCG) due to the existing studies ignore the spatiotemporal features of VCG. METHODS: In this paper, a precise MI localization method was proposed based on Tucker decomposition. The multi-scale characteristics of wavelet transform and the spatiotemporal characteristics of VCG were used to construct the VCG tensor containing the local and the spatiotemporal information. The VCG tensor was compressed in the time dimension based on Tucker decomposition to remove redundant information and extract the local spatiotemporal features. The features were fed back to the TreeBagger classifier. RESULTS: The proposed method achieved a total accuracy of 99.80% for 11 types of MI on the benchmark Physikalisch-Technische Bundesanstalt database. The area under the receiver operating characteristic curves and precision-recall curves of each kind of VCG signal was more than 0.88. CONCLUSION: The proposed algorithm effectively realized the classification of normal and 11 categories of MI using VCG. SIGNIFICANCE: Therefore, this study provides new ideas for the intelligent diagnosis of MI based on VCG.


Assuntos
Infarto do Miocárdio , Vetorcardiografia , Humanos , Vetorcardiografia/métodos , Infarto do Miocárdio/diagnóstico , Análise de Ondaletas , Algoritmos , Bases de Dados Factuais
12.
Am J Physiol Heart Circ Physiol ; 323(5): H996-H1003, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36206051

RESUMO

There are numerous sex-related differences in cardiac electrophysiology and arrhythmia propensity but very little knowledge about the reasons. Difference in body size has been proposed as one reason and was tested in this study of >20 cardiac electrophysiology parameters in 319 (158 women) apparently healthy 50- to 64-yr-old subjects from a randomly enrolled population sample, the pilot SCAPIS (Swedish Cardiopulmonary Bioimaging Study), using Frank vectorcardiography. We studied conventional conduction intervals, parameters reflecting electrical heterogeneity (dispersion) in the ventricles, QRS- and T-vector directions, spatial QRS-T angles, and T-vector loop morphology. Body surface area (BSA; 2 methods) and lean body mass (LBM), both estimated from body weight and height, were used as body size parameters. According to multivariable linear regression analysis adjusted for sex, there was no association between electrophysiological parameters and body size apart from QRS duration and QRSarea. In conclusion, most electrophysiological parameters assessed completely noninvasively and showing statistically significant differences between women and men on the group level show no association with BSA or LBM. Scaling (indexing) the electrophysiological parameters for body size parameters is therefore not an option. Consequently, the explanation for the sex-related electrophysiological differences should be sought along other lines.NEW & NOTEWORTHY We sought explanations for sex-related differences in >20 cardiac electrophysiology parameters including conventional conduction intervals in 319 (158 women) apparently healthy 50- to 64-yr-old subjects using Frank vectorcardiography, a novelty. Our hypothesis that body size was partly explanatory for such differences had to be refuted apart from QRS duration and QRSarea. Scaling (indexing) electrophysiological parameters for body size is therefore not an option and explanations for electrophysiological sex-related differences are to be sought elsewhere.


Assuntos
Coração , Vetorcardiografia , Feminino , Humanos , Masculino , Arritmias Cardíacas , Tamanho Corporal , Coração/fisiologia , Ventrículos do Coração , Vetorcardiografia/métodos , Pessoa de Meia-Idade
14.
Ter Arkh ; 94(9): 1122-1125, 2022 Oct 24.
Artigo em Russo | MEDLINE | ID: mdl-36286765

RESUMO

The vector concept in the analysis of the electrical signals of the heart began to be used at the dawn of the development of electrocardiology. For several decades, vectorcardiography has developed in parallel with electrocardiography; reached its peak in the 60s, and after a period of cooling experienced a resurgence since the early 90s, when it became possible to mathematically synthesize vectorcardiograms (VCG) from digital electrocardiograms in 12 leads. VCG reflects the same phenomena as electrocardiography, but allows you to calculate and visualize a number of three-dimensional characteristics of the electrical signals of the heart. The article describes the main milestones in the development of the VCG, the history of international cooperation in this area, the contribution of domestic scientists to this field of science. Modern promising areas of research related to the vector concept of the analysis of the electrical signals of the heart are briefly reflected.


Assuntos
Eletrocardiografia , Vetorcardiografia , Humanos , Vetorcardiografia/métodos , Eletrocardiografia/métodos , Coração
15.
Sci Rep ; 12(1): 9961, 2022 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-35705598

RESUMO

Alteration of muscle activation sequence is a key mechanism in heart failure with reduced ejection fraction. Successful cardiac resynchronization therapy (CRT), which has become standard therapy in these patients, is limited by the lack of precise dyssynchrony quantification. We implemented a computational pipeline that allows assessment of ventricular dyssynchrony by vectorcardiogram reconstruction from the patient's electrocardiogram. We defined a ventricular dyssynchrony index as the distance between the voltage and speed time integrals of an individual observation and the linear fit of these variables obtained from a healthy population. The pipeline was tested in a 1914-patient population. The dyssynchrony index showed minimum values in heathy controls and maximum values in patients with left bundle branch block (LBBB) or with a pacemaker (PM). We established a critical dyssynchrony index value that discriminates electrical dyssynchronous patterns (LBBB and PM) from ventricular synchrony. In 10 patients with PM or CRT devices, dyssynchrony indexes above the critical value were associated with high time to peak strain standard deviation, an echocardiographic measure of mechanical dyssynchrony. Our index proves to be a promising tool to evaluate ventricular activation dyssynchrony, potentially enhancing the selection of candidates for CRT, device configuration during implantation, and post-implant optimization.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Arritmias Cardíacas , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Vetorcardiografia
16.
IEEE J Transl Eng Health Med ; 10: 1900208, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35769406

RESUMO

Objective: Vectorcardiography (VCG) as an alternative form of ECG provides important spatial information about the electrical activity of the heart. It achieves higher sensitivity in the detection of some pathologies such as myocardial infarction, ischemia and hypertrophy. However, vectorcardiography is not commonly measured in clinical practice, and for this reason mathematical transformations have been developed to obtain derived VCG leads, which in application in current systems and subsequent analysis can contribute to early diagnosis and obtaining other useful information about the electrical activity of the heart. Methods and procedures: The most frequently used transformation methods are compared, namely the Kors regression method, the Inverse Dower transformation, QLSV and the Quasi-orthogonal transformation. These transformation methods were used on 30 randomly selected records with a diagnosis of myocardial infarction from the Physikalisch-Technische Bundesanstalt (PTB) database and their accuracy was evaluated based on the calculation of the mean square error (MSE). MSE was subjected to statistical evaluation at a significance level of 0.05. Results: Based on statistical testing using the nonparametric multiselective Kruskall-Wallis test and subsequent post-hoc analysis using the Dunn method, the Kors regression as a whole method achieved the most accurate transformation. Conclusion: The results of statistical analysis provide an evaluation of the accuracy of several transformation methods for deriving orthogonal leads, for possible application in measuring and evaluation systems, which may contribute to the correct choice of method for subsequent analysis of electrical activity of the heart at orthogonal leads to predict various diseases.


Assuntos
Diagnóstico por Computador , Infarto do Miocárdio , Bases de Dados Factuais , Diagnóstico por Computador/métodos , Coração , Humanos , Infarto do Miocárdio/diagnóstico , Vetorcardiografia/métodos
17.
J. health inform ; 14(1): 3-10, jan.-mar. 2022. ilus
Artigo em Inglês | LILACS | ID: biblio-1370250

RESUMO

Objectives: Thousands of people suffer from cardiovascular diseases. Even though the electrocardiogram is an exam consolidated. The lack of methodological observation in the placement of sensors can compromise the results. This article proposes a wearable vest capable of conditioning cardiac signals from three simultaneous channels, reducing the chance of failures in the exam due to the smaller number of electrodes attached to the patient's body. Methods: It adds the vectorcardiogram technique to the electrocardiogram wearable, which consists of three orthonormal derivations Vx, Vy, and Vz, measuring dynamic components of the heart vector. Results: The display of the cardiac biopotential in the web-mobile application represents the visualization of the twelve derivations synthesized from the Dower transform and the spatial projections of the cardiac loop under a three-dimensional view. Conclusion: Feasibility of integrating the vectorcardiogram with the electrocardiogram exam.


Objetivos: Milhares de pessoas sofrem com doenças cardiovasculares, apesar do Eletrocardiograma ser um exame consolidado, a falta de observação metodológica na colocação dos sensores pode comprometer os resultados. O presente artigo propõe um colete vestível capaz de condicionar sinais cardíacos de três canais simultâneos, reduzindo a chance de falhas na execução do exame em função da menor quantidade de eletrodos fixados ao corpo do paciente. Métodos: Acrescenta a técnica do vetocardiograma ao vestível de eletrocardiograma, que consiste em três derivações ortonormais Vx, Vy e Vz, medindo componentes dinâmicos do vetor coração. Resultados: Exibição do biopotencial cardíaco na aplicação web-mobile representa de forma satisfatória a visualização das doze derivações sintetizadas a partir da transformada de Dower, bem como, as projeções espaciais do loop cardíaco sob uma visão tridimensional. Conclusão: Viabilidade de integração do vetocardiograma ao exame de eletrocardiograma.


Objetivos: Miles de personas padecen enfermedades cardiovasculares, a pesar de que el electrocardiograma es un examen consolidado, la falta de observación metodológica en la colocación de sensores puede comprometer los resultados. Este artículo propone una tecnología vestible capaz de acondicionar las señales cardíacas de tres canales simultáneos, reduciendo la posibilidad de fallas en el examen por la menor cantidad de electrodos adheridos al cuerpo del paciente. Métodos: Agrega la técnica del vetocardiograma al electrocardiograma vestible, que consta de tres derivaciones ortonormales Vx, Vy y Vz, midiendo los componentes dinámicos del vector cardíaco. Resultados: La visualización del biopotencial cardíaco en la aplicación web-móvil representa satisfactoriamente la visualización de las doce derivaciones sintetizadas a partir de la transformada de Dower, así como las proyecciones espaciales del bucle cardíaco bajo una vista tridimensional. Conclusión: Viabilidad de integrar el vetocardiograma con el examen electrocardiográfico.


Assuntos
Humanos , Vetorcardiografia/instrumentação , Doenças Cardiovasculares/diagnóstico , Eletrocardiografia/instrumentação , Dispositivos Eletrônicos Vestíveis
18.
PLoS One ; 17(2): e0263894, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35171953

RESUMO

The predictive value of non-invasive electrocardiographic examination findings for the risk of sudden cardiac death (SCD) in populations with structurally normal hearts remains unclear. This study aimed to investigate the characteristics of the QRS vectorcardiography of surface electrocardiography in patients with structurally normal hearts who experienced SCD. We consecutively enrolled patients who underwent vectorcardiography between March 2017 and December 2018 in a tertiary referral medical center. These patients didn't have structural heart diseases, histories of congestive heart failure, or reduced ejection fraction, and they were classified into SCD (with aborted SCD history and cerebral performance category score of 1) and control groups (with an intervention for atrioventricular node reentrant tachycardia and without SCD history). A total of 162 patients (mean age, 54.3±18.1 years; men, 75.9%), including 59 in the SCD group and 103 in the control group, underwent propensity analysis. The baseline demographic variables, underlying diseases, QRS loop descriptors (the percentage of the loop area, loop dispersion, and inter-lead QRS dispersion), and other electrocardiographic parameters were compared between the two groups. In the univariate and multivariate analyses, a smaller percentage of the loop area (odds ratio, 0.0003; 95% confidence interval, 0.00-0.02; p<0.001), more significant V4-5 dispersion (odds ratio, 1.04; 95% confidence interval, 1.02-1.07; p = 0.002), and longer QRS duration (odds ratio, 1.05; 95% confidence interval, 1.00-1.10; p = 0.04) were associated with SCD. In conclusion, the QRS loop descriptors of surface electrocardiography could be used as non-invasive markers to identify patients experiencing aborted SCD from a healthy population. A decreased percentage of loop area and elevated V4-5 QRS dispersion values assessed using vectorcardiography were associated with an increased risk of SCD in patients with structurally normal hearts.


Assuntos
Morte Súbita Cardíaca/etiologia , Eletrocardiografia/métodos , Coração/fisiopatologia , Medição de Risco/métodos , Vetorcardiografia/métodos , Estudos de Casos e Controles , Morte Súbita Cardíaca/patologia , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Risco
19.
Pacing Clin Electrophysiol ; 45(3): 393-400, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35000207

RESUMO

BACKGROUND: QRS area, a three-dimensional QRS complex, is a novel vectorcardiography method of measuring the magnitude of electrical forces in the heart. Hypothetically, a greater QRS area denotes higher dyssynchrony and indicates potential benefits from cardiac resynchronization therapy (CRT). Previous studies suggest a positive correlation between QRS area and the degree of response to CRT, but its clinical use remains unclear. We performed a meta-analysis of the relationship between QRS area and survival benefit following CRT. METHODS: We comprehensively searched the MEDLINE, EMBASE, and Cochrane databases from inception to August 2021. We included studies with prospective and retrospective cohort designs that reported QRS area before CRT and total mortality. Data from each study were analyzed using a random-effects model. The results were reported as a hazard ratio (HR) and 95% confidence intervals. RESULTS: Five observational studies including 4931 patients were identified. The cut-off values between large and small QRS areas ranged from 102 to 116 µVs. Our analysis showed a larger QRS area was statistically associated with increased 5-year survival in patients implanted with CRT (HR pooled 0.48, 95% CI 0.46-0.51, I2  = 54%, p < .0001). Greater QRS area reduction (pre- and post-implantation) were associated with a lower total mortality rate (HR pooled 0.45, 95% CI 0.38-0.52, I2  = 0%, p < .0001). CONCLUSION: Larger pre-implantation QRS area was associated with increased survival after CRT. QRS area reduction following CRT implantation was also associated with lower mortality. QRS area may potentially become an additional selection criterion for CRT implantations.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia , Insuficiência Cardíaca/terapia , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento , Vetorcardiografia/métodos
20.
J Electrocardiol ; 70: 79-83, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34971852

RESUMO

BACKGROUND: Patients with atrial septal defects and pulmonary hypertension would benefit from early identification and treatment of pulmonary hypertension prior to closure. Noninvasive screening tools for pulmonary hypertension are inadequate. Electrocardiography, though readily available, has so far been of limited screening utility in patients with pulmonary hypertension. We hypothesize that derived vectorcardiographic parameters will aid in identifying increased right ventricular afterload and thus provide an additional screening tool for pulmonary hypertension in patients with secundum atrial septal defects. OBJECTIVE: Establish whether vectorcardiography can be used to screen for pulmonary hypertension. METHODS: A retrospective review of patients with secundum atrial septal defects (ASD) who underwent cardiac catheterization at the University of Minnesota from 2012 to 2020 was performed. We excluded patients with other congenital heart diagnoses, insufficient hemodynamic data, or lacking sinus rhythm electrocardiogram at time of cardiac catheterization. Parameters analyzed included: Sokolow-Lion right ventricular hypertrophy criteria, PR duration, QRS duration, corrected QT intervals, QRS and T wave frontal plane axes, rSR', R' amplitude, as well as vectorcardiographic parameters (Kors regression-related method), the QRS vector magnitude, T wave vector magnitude, and the spatial QRS-T angle. These were compared to measures of pulmonary hypertension obtained at cardiac catheterization. RESULTS: The spatial QRS-T angle significantly differentiated ASD patients with pulmonary hypertension (median 104 degrees, interquartile range 55-137 degrees) from ASD patients without pulmonary hypertension (median 37 degrees, interquartile range 21-63 degrees, p-value of 0.002). At a cut-off of 124 degrees, the positive and negative predictive values for identification of pulmonary hypertension were 36.4% and 96.4%, respectively, with an odds ratio of 13.4 (95% confidence interval of 2.9 to 63.7). The positive predictive value was significantly improved when combined with echocardiographic data to screen for pulmonary hypertension. CONCLUSION: The spatial QRS-T angle is associated with pulmonary hypertension in patients with secundum atrial septal defects.


Assuntos
Comunicação Interatrial , Hipertensão Pulmonar , Ecocardiografia , Eletrocardiografia , Comunicação Interatrial/diagnóstico , Ventrículos do Coração , Humanos , Hipertensão Pulmonar/diagnóstico , Vetorcardiografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA