ABSTRACT
This paper focuses on a method for measuring the electron temperature (T(e)) without knowing the transmissivity using Thomson scattering diagnostic with a double-pass scattering system. Application of this method for measuring the anisotropic T(e), i.e., the T(e) in the directions parallel (T(eparallel)) and perpendicular (T(eperpendicular)) to the magnetic field, is proposed. Simulations based on the designed parameters for a JT-60SA indicate the feasibility of the measurements except in certain T(e) ranges, e.g., T(eparallel) ~ 3.5T(eperpendicular) at 120° of the scattering angle.