Your browser doesn't support javascript.
loading
Time to intervention in patients with splenic injury in a Dutch level 1 trauma centre.
Olthof, D C; Sierink, J C; van Delden, O M; Luitse, J S K; Goslings, J C.
Affiliation
  • Olthof DC; Trauma Unit Department of Surgery, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands. Electronic address: d.c.olthof@amc.nl.
Injury ; 45(1): 95-100, 2014 Jan.
Article in En | MEDLINE | ID: mdl-23375696
ABSTRACT

BACKGROUND:

Timely intervention in patients with splenic injury is essential, since delay to treatment is associated with an increased risk of mortality. Transcatheter Arterial Embolisation (TAE) is increasingly used as an adjunct to non-operative management. The aim of this study was to report time intervals between admission to the trauma room and start of intervention (TAE or splenic surgery) in patients with splenic injury.

METHODS:

Consecutive patients with splenic injury aged ≥ 16 years admitted between January 2006 and January 2012 were included. Data were reported according to haemodynamic status (stable versus unstable). In haemodynamically (HD) unstable patients, transfusion requirement, intervention-related complications and the need for a re-intervention were compared between the TAE and splenic surgery group.

RESULTS:

The cohort consisted of 96 adults of whom 16 were HD unstable on admission. In HD stable patients, median time to intervention was 105 (IQR 77-188) min 117 (IQR 78-233) min for TAE compared to 95 (IQR 69-188) for splenic surgery (p=0.58). In HD unstable patients, median time to intervention was 58 (IQR 41-99) min 46 (IQR 27-107) min for TAE compared to 64 (IQR 45-80) min for splenic surgery (p=0.76). The median number of transfused packed red blood cells was 8 (3-22) in HD unstable patients treated with TAE versus 24 (9-55) in the surgery group (p=0.09). No intervention-related complications occurred in the TAE group and one in the splenic surgery group (p=0.88). Two spleen related re-interventions were performed in the TAE group versus 3 in the splenic surgery group (p=0.73).

CONCLUSIONS:

Time to intervention did not differ significantly between HD unstable patients treated with TAE and patients treated with splenic surgery. Although no difference was observed with regard to intervention-related complications and the need for a re-intervention, a trend towards lower transfusion requirement was observed in patients treated with TAE compared to patients treated with splenic surgery. We conclude that if 24/7 interventional radiology facilities are available, TAE is not associated with time loss compared to splenic surgery, even in HD unstable patients.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Spleen / Trauma Centers / Wounds, Nonpenetrating / Catheterization / Tomography, X-Ray Computed / Embolization, Therapeutic Type of study: Guideline / Observational_studies / Risk_factors_studies Limits: Adult / Female / Humans / Male Country/Region as subject: Europa Language: En Journal: Injury Year: 2014 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Spleen / Trauma Centers / Wounds, Nonpenetrating / Catheterization / Tomography, X-Ray Computed / Embolization, Therapeutic Type of study: Guideline / Observational_studies / Risk_factors_studies Limits: Adult / Female / Humans / Male Country/Region as subject: Europa Language: En Journal: Injury Year: 2014 Document type: Article