Your browser doesn't support javascript.
loading
Evidence of second-trimester changes in head biometry and brain perfusion in fetuses with congenital heart disease.
Masoller, N; Martínez, J M; Gómez, O; Bennasar, M; Crispi, F; Sanz-Cortés, M; Egaña-Ugrinovic, G; Bartrons, J; Puerto, B; Gratacós, E.
Affiliation
  • Masoller N; BCNatal - Barcelona Center for Maternal-Fetal and Neonatal Medicine (Hospital Clínic and Hospital Sant Joan de Déu), IDIBAPS, University of Barcelona, and Centre for Biomedical Research on Rare Diseases (CIBER-ER), Barcelona, Spain.
Ultrasound Obstet Gynecol ; 44(2): 182-7, 2014 Aug.
Article in En | MEDLINE | ID: mdl-24687311
ABSTRACT

OBJECTIVES:

To evaluate the associations between congenital heart disease (CHD) and head biometry and cerebrovascular blood flow dynamics at the time of diagnosis of CHD in the second trimester of pregnancy.

METHODS:

This was a study of 95 consecutive fetuses diagnosed with CHD. At the time of diagnosis, fetal biometry was performed and brain perfusion was assessed by middle cerebral artery pulsatility index (MCA-PI), cerebroplacental ratio (CPR) and fractional moving blood volume (FMBV). The results were compared with those of 95 normal fetuses matched for gestational age.

RESULTS:

Median gestational age at diagnosis was 22 + 3 (range, 20 + 0 to 23 + 5) weeks. Fetuses with CHD showed significantly lower MCA-PI and CPR Z-scores (-0.23 vs 0.34 and -0.37 vs 0.30, respectively; both P < 0.001) and higher FMBV Z-scores (2.35 vs 0.15; P < 0.001). FMBV > 95(th) percentile was observed in 81.1% of cases as compared with 10.5% in controls (P < 0.001). Moreover, cases showed significantly smaller biparietal diameter (BPD) and head circumference (HC) Z-scores (-1.61 vs -0.43 and -0.89 vs 0.09, respectively; both P < 0.001), with a higher proportion of BPD and HC measurements below the 5(th) percentile compared with controls (51.6% vs 13.7% and 26.3% vs 4.2%, respectively; both P < 0.001). These findings were more pronounced in those cases with types of CHD associated with compromised oxygenated blood delivery to the brain, such as left outflow tract obstruction and transposition of the great arteries.

CONCLUSIONS:

A high proportion of fetuses with CHD have a smaller head and increased brain perfusion already in the second trimester, suggesting an early onset of the mechanisms leading to poorer neurodevelopment later in life.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Brain / Fetal Diseases / Head / Heart Defects, Congenital Type of study: Observational_studies / Risk_factors_studies Limits: Adult / Female / Humans / Pregnancy Language: En Journal: Ultrasound Obstet Gynecol Year: 2014 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Brain / Fetal Diseases / Head / Heart Defects, Congenital Type of study: Observational_studies / Risk_factors_studies Limits: Adult / Female / Humans / Pregnancy Language: En Journal: Ultrasound Obstet Gynecol Year: 2014 Document type: Article