Your browser doesn't support javascript.
loading
Ex Vivo Liver Experiment of Hydrochloric Acid-Infused and Saline-Infused Monopolar Radiofrequency Ablation: Better Outcomes in Temperature, Energy, and Coagulation.
Jiang, Xiong-ying; Gu, Yang-kui; Huang, Jin-hua; Gao, Fei; Zou, Ru-hai; Zhang, Tian-qi.
Affiliation
  • Jiang XY; Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, 510060, People's Republic of China.
  • Gu YK; Department of Minimally Invasive Interventional Radiology, Sun Yat-sen University Cancer Center, Guangzhou, Guangdong, 510060, People's Republic of China.
  • Huang JH; Department of Interventional Radiology, Sun Yat-sen Memorial Hospital, Guangzhou, Guangdong, 510120, People's Republic of China.
  • Gao F; Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, 510060, People's Republic of China.
  • Zou RH; Department of Minimally Invasive Interventional Radiology, Sun Yat-sen University Cancer Center, Guangzhou, Guangdong, 510060, People's Republic of China.
  • Zhang TQ; Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, 510060, People's Republic of China. huangjh@sysucc.org.cn.
Cardiovasc Intervent Radiol ; 39(4): 600-5, 2016 Apr.
Article in En | MEDLINE | ID: mdl-26486153
ABSTRACT

OBJECTIVE:

To compare temperature, energy, and coagulation between hydrochloric acid-infused radiofrequency ablation (HAIRFA) and normal saline-infused radiofrequency ablation (NSIRFA) in ex vivo porcine liver model. MATERIALS AND

METHODS:

30 fresh porcine livers were excised in 60 lesions, 30 with HAIRFA and the other 30 with NSIRFA. Both modalities used monopolar perfusion electrode connected to a RF generator set at 103 °C and 30 W. In each group, ablation time was set at 10, 20, or 30 min (10 lesions from each group at each time). We compared tissue temperatures (at 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 cm away from the electrode tip), average power, deposited energy, deposited energy per coagulation volume (DEV), coagulation diameters, coagulative volume, and spherical ratio between the two groups.

RESULTS:

Temperature-time curves showed that HAIRFA provided progressively greater heating than that of NSIRFA. At 30 min, mean average power, deposited energy, coagulation volumes (113.67 vs. 12.28 cm(3)) and diameters, and increasing in tissue temperature were much greater with HAIRFA (P < 0.001 for all), except DEV was lower (456 vs. 1396 J/cm(3), P < 0.001). The spherical ratio was closer to 1 with HAIRFA (1.23 vs. 1.46). Coagulation diameters, volume, and average power of HAIRFA increased significantly with longer ablation times. While with NSIRFA, these characteristics were stable till later 20 min, except the power decreased with longer ablation times.

CONCLUSIONS:

HAIRFA creates much larger and more spherical lesions by increasing overall energy deposition, modulating thermal conductivity, and transferring heat during ablation.