Your browser doesn't support javascript.
loading
Automated Generation of Reliable Blood Velocity Parameter Maps from Contrast-Enhanced Ultrasound Data.
Theek, Benjamin; Opacic, Tatjana; Möckel, Diana; Schmitz, Georg; Lammers, Twan; Kiessling, Fabian.
Affiliation
  • Theek B; Institute for Experimental Molecular Imaging, RWTH Aachen University Clinic and Helmholtz Institute for Biomedical Engineering, Pauwelsstr. 30, 52074 Aachen, Germany.
  • Opacic T; Institute for Experimental Molecular Imaging, RWTH Aachen University Clinic and Helmholtz Institute for Biomedical Engineering, Pauwelsstr. 30, 52074 Aachen, Germany.
  • Möckel D; Institute for Experimental Molecular Imaging, RWTH Aachen University Clinic and Helmholtz Institute for Biomedical Engineering, Pauwelsstr. 30, 52074 Aachen, Germany.
  • Schmitz G; Department of Medical Engineering, Ruhr-University Bochum, Universitätsstr. 150, 44801 Bochum, Germany.
  • Lammers T; Institute for Experimental Molecular Imaging, RWTH Aachen University Clinic and Helmholtz Institute for Biomedical Engineering, Pauwelsstr. 30, 52074 Aachen, Germany.
  • Kiessling F; Institute for Experimental Molecular Imaging, RWTH Aachen University Clinic and Helmholtz Institute for Biomedical Engineering, Pauwelsstr. 30, 52074 Aachen, Germany.
Contrast Media Mol Imaging ; 2017: 2098324, 2017.
Article in En | MEDLINE | ID: mdl-29097912
ABSTRACT

Objectives:

The purpose of this study was the automated generation and validation of parametric blood flow velocity maps, based on contrast-enhanced ultrasound (CEUS) scans. Materials and

Methods:

Ethical approval for animal experiments was obtained. CEUS destruction-replenishment sequences were recorded in phantoms and three different tumor xenograft mouse models. Systematic pixel binning and intensity averaging was performed to generate parameter maps of blood flow velocities with different pixel resolution. The 95% confidence interval of the mean velocity, calculated on the basis of the whole tumor segmentation, served as ground truth for the different parameter maps.

Results:

In flow phantoms the measured mean velocity values were only weakly influenced by the pixel resolution and correlated with real velocities (r2 ≥ 0.94, p < 0.01). In tumor xenografts, however, calculated mean velocities varied significantly (p < 0.0001), depending on the parameter maps' resolution. Pixel binning was required for all in vivo measurements to obtain reliable parameter maps and its degree depended on the tumor model.

Conclusion:

Systematic pixel binning allows the automated identification of optimal pixel resolutions for parametric maps, supporting textural analysis of CEUS data. This approach is independent from the ultrasound setup and can be implemented in the software of other (clinical) ultrasound devices.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Blood Flow Velocity / Ultrasonography Type of study: Diagnostic_studies Aspects: Ethics Limits: Animals / Humans Language: En Journal: Contrast Media Mol Imaging Year: 2017 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Blood Flow Velocity / Ultrasonography Type of study: Diagnostic_studies Aspects: Ethics Limits: Animals / Humans Language: En Journal: Contrast Media Mol Imaging Year: 2017 Document type: Article