Your browser doesn't support javascript.
loading
Real-Time X-MRI-Guided Left Ventricular Lead Implantation for Targeted Delivery of Cardiac Resynchronization Therapy.
Behar, Jonathan M; Mountney, Peter; Toth, Daniel; Reiml, Sabrina; Panayiotou, Maria; Brost, Alexander; Fahn, Bernhard; Karim, Rashed; Claridge, Simon; Jackson, Tom; Sieniewicz, Ben; Patel, Nik; O'Neill, Mark; Razavi, Reza; Rhode, Kawal; Rinaldi, Christopher Aldo.
Affiliation
  • Behar JM; Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom. Electronic address: jonathanbehar@gmail.com.
  • Mountney P; Medical Imaging Technologies, Siemens Healthineers, Princeton, New Jersey.
  • Toth D; Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom; Siemens Healthineers, Frimley, Camberley, United Kingdom.
  • Reiml S; Siemens Healthcare GmbH, Erlangen, Germany.
  • Panayiotou M; Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom.
  • Brost A; Siemens Healthcare GmbH, Erlangen, Germany.
  • Fahn B; Siemens Healthcare GmbH, Erlangen, Germany.
  • Karim R; Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom.
  • Claridge S; Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom.
  • Jackson T; Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom.
  • Sieniewicz B; Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom.
  • Patel N; Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom.
  • O'Neill M; Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom.
  • Razavi R; Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom.
  • Rhode K; Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom.
  • Rinaldi CA; Department of Imaging Sciences and Biomedical Engineering, King's College London, & Guy's and St Thomas' Hospital, London, United Kingdom.
JACC Clin Electrophysiol ; 3(8): 803-814, 2017 08.
Article in En | MEDLINE | ID: mdl-29759775

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Defibrillators, Implantable / Prosthesis Implantation / Magnetic Resonance Imaging, Interventional / Cardiac Resynchronization Therapy Type of study: Guideline / Prognostic_studies Limits: Aged / Humans Language: En Journal: JACC Clin Electrophysiol Year: 2017 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Defibrillators, Implantable / Prosthesis Implantation / Magnetic Resonance Imaging, Interventional / Cardiac Resynchronization Therapy Type of study: Guideline / Prognostic_studies Limits: Aged / Humans Language: En Journal: JACC Clin Electrophysiol Year: 2017 Document type: Article