Your browser doesn't support javascript.
loading
First-in-Human Experience With Patient-Specific Computer Simulation of TAVR in Bicuspid Aortic Valve Morphology.
Dowling, Cameron; Firoozi, Sami; Brecker, Stephen J.
Affiliation
  • Dowling C; Cardiology Clinical Academic Group, St. George's, University of London and St. George's University Hospitals NHS Foundation Trust, London, United Kingdom. Electronic address: cameron.dowling@stgeorges.nhs.uk.
  • Firoozi S; Cardiology Clinical Academic Group, St. George's, University of London and St. George's University Hospitals NHS Foundation Trust, London, United Kingdom.
  • Brecker SJ; Cardiology Clinical Academic Group, St. George's, University of London and St. George's University Hospitals NHS Foundation Trust, London, United Kingdom.
JACC Cardiovasc Interv ; 13(2): 184-192, 2020 01 27.
Article in En | MEDLINE | ID: mdl-31629752
OBJECTIVES: The aim of this study was to prospectively evaluate the clinical use of patient-specific computer simulation of transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) morphology. BACKGROUND: Patient-specific computer simulation of TAVR in BAV may predict important clinical outcomes, such as paravalvular regurgitation and conduction disturbance. METHODS: Between May 2018 and April 2019, all patients who were referred for TAVR who had BAV identified on work-up cardiac multidetector computed tomographic imaging prospectively underwent patient-specific computer simulation with a self-expanding transcatheter heart valve (THV) using TAVIguide technology. RESULTS: Nine patients were included in the study. Sievers classification was type 0 in 2 patients and type 1 in 7 patients. The simulations altered the treatment strategy in 8 patients (89%). The simulations suggested moderate to severe paravalvular regurgitation in 3 patients, who were referred for consideration of surgery. The remaining 6 patients underwent TAVR with a self-expanding THV. In 5 of these patients (83%), THV size and/or implantation depth was altered to minimize paravalvular regurgitation and/or conduction disturbance. In 1 patient, simulations suggested significant conduction disturbance after TAVR, and a permanent pacemaker was implanted before the procedure. Following treatment, all 9 patients had no to mild paravalvular regurgitation. The patient who had a pre-procedure permanent pacemaker implanted became pacing dependent, with underlying third-degree atrioventricular block. CONCLUSIONS: Patient-specific computer simulation of TAVR in BAV can be used to identify those patients where TAVR may be associated with unfavorable clinical outcomes. Patient-specific computer simulation may be useful to guide THV sizing and positioning for potential favorable clinical outcomes.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Health context: 1_ASSA2030 / 2_ODS3 / 6_ODS3_enfermedades_notrasmisibles Database: MEDLINE Main subject: Aortic Valve / Multidetector Computed Tomography / Transcatheter Aortic Valve Replacement / Patient-Specific Modeling / Heart Valve Diseases / Models, Cardiovascular Type of study: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Aged / Aged80 / Female / Humans / Male Language: En Journal: JACC Cardiovasc Interv Year: 2020 Document type: Article

Full text: 1 Collection: 01-internacional Health context: 1_ASSA2030 / 2_ODS3 / 6_ODS3_enfermedades_notrasmisibles Database: MEDLINE Main subject: Aortic Valve / Multidetector Computed Tomography / Transcatheter Aortic Valve Replacement / Patient-Specific Modeling / Heart Valve Diseases / Models, Cardiovascular Type of study: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Aged / Aged80 / Female / Humans / Male Language: En Journal: JACC Cardiovasc Interv Year: 2020 Document type: Article