Your browser doesn't support javascript.
loading
Pacemaker Implantation After Balloon- or Self-Expandable Transcatheter Aortic Valve Replacement in Patients With Aortic Stenosis.
Bisson, Arnaud; Bodin, Alexandre; Herbert, Julien; Lacour, Thibaut; Saint Etienne, Christophe; Pierre, Bertrand; Clementy, Nicolas; Deharo, Pierre; Babuty, Dominique; Fauchier, Laurent.
Affiliation
  • Bisson A; Service de Cardiologie Centre Hospitalier Universitaire Trousseau et Faculté de Médecine EA7505 Université de Tours France.
  • Bodin A; Service de Cardiologie Centre Hospitalier Universitaire Trousseau et Faculté de Médecine EA7505 Université de Tours France.
  • Herbert J; Service de Cardiologie Centre Hospitalier Universitaire Trousseau et Faculté de Médecine EA7505 Université de Tours France.
  • Lacour T; Service d'information Médicale, d'épidémiologie et d'économie de la santé Centre Hospitalier Universitaire et Faculté de Médecine EA7505 Université de Tours France.
  • Saint Etienne C; Service de Cardiologie Centre Hospitalier Universitaire Trousseau et Faculté de Médecine EA7505 Université de Tours France.
  • Pierre B; Service de Cardiologie Centre Hospitalier Universitaire Trousseau et Faculté de Médecine EA7505 Université de Tours France.
  • Clementy N; Service de Cardiologie Centre Hospitalier Universitaire Trousseau et Faculté de Médecine EA7505 Université de Tours France.
  • Deharo P; Service de Cardiologie Centre Hospitalier Universitaire Trousseau et Faculté de Médecine EA7505 Université de Tours France.
  • Babuty D; Département de Cardiologie Centre Hospitalier Universitaire Timone Marseille France.
  • Fauchier L; Inserm Inra C2VN Marseille France.
J Am Heart Assoc ; 9(9): e015896, 2020 05 05.
Article in En | MEDLINE | ID: mdl-32362220
ABSTRACT
Background The incidence of conduction abnormalities requiring permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with early and later generation prostheses remains debated. Methods and Results Based on the administrative hospital-discharge database, we collected information for all patients treated with TAVR between 2010 and 2019 in France. We compared the incidence of PPI after TAVR according to the type and generation of valve implanted. A total of 49 201 patients with aortic stenosis treated with TAVR using the balloon-expandable (BE) Edwards SAPIEN valve (early Sapien XT and latest Sapien 3) or the self-expanding (SE) Medtronic CoreValve (early CoreValve and latest Evolut R) were found in the database. Mean (SD) follow-up was 1.2 (1.5 years) (median [interquartile range] 0.6 [0.1-2.0] years). PPI after the procedure was reported in 13 289 patients, among whom 11 010 (22.4%) had implantation during the first 30 days. In multivariable analysis, using early BE TAVR as reference, adjusted odds ratio (95% CI) for PPI during the first 30 days was 0.88 (0.81-0.95) for latest BE TAVR, 1.40 (1.27-1.55) for early SE TAVR, and 1.17 (1.07-1.27) for latest SE TAVR. Compared with early BE TAVR, the adjusted hazard ratio for PPI during the whole follow-up was 1.01 (0.95-1.08) for latest BE TAVR, 1.30 (1.21-1.40) for early SE TAVR, and 1.25 (1.18-1.34) for latest SE TAVR. Conclusions In patients with aortic stenosis treated with TAVR, our systematic analysis at a nationwide level found higher rates of PPI than previously reported. BE technology was independently associated with lower incidence rates of PPI both at the acute and chronic phases than SE technology. Recent generations of TAVR were not independently associated with different rates of PPI than early generations during the overall follow-up.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Topics: Promover_ampliacao_atencao_especializada Database: MEDLINE Main subject: Aortic Valve Stenosis / Pacemaker, Artificial / Arrhythmias, Cardiac / Heart Valve Prosthesis / Cardiac Pacing, Artificial / Transcatheter Aortic Valve Replacement Type of study: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Aged / Aged80 / Female / Humans / Male Country/Region as subject: Europa Language: En Journal: J Am Heart Assoc Year: 2020 Document type: Article

Full text: 1 Collection: 01-internacional Topics: Promover_ampliacao_atencao_especializada Database: MEDLINE Main subject: Aortic Valve Stenosis / Pacemaker, Artificial / Arrhythmias, Cardiac / Heart Valve Prosthesis / Cardiac Pacing, Artificial / Transcatheter Aortic Valve Replacement Type of study: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Aged / Aged80 / Female / Humans / Male Country/Region as subject: Europa Language: En Journal: J Am Heart Assoc Year: 2020 Document type: Article