Your browser doesn't support javascript.
loading
Full-field strain of regenerated bone tissue in a femoral fracture model.
Karali, A; Kao, A P; Meeson, R; Roldo, M; Blunn, G W; Tozzi, G.
Affiliation
  • Karali A; Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Portsmouth, UK.
  • Kao AP; Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Portsmouth, UK.
  • Meeson R; Royal Veterinary College, Hatfield, Hertfordshire, UK.
  • Roldo M; School of Pharmacy and Biomedical Sciences, University of Portsmouth, Portsmouth, UK.
  • Blunn GW; School of Pharmacy and Biomedical Sciences, University of Portsmouth, Portsmouth, UK.
  • Tozzi G; Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Portsmouth, UK.
J Microsc ; 285(3): 156-166, 2022 03.
Article in En | MEDLINE | ID: mdl-32530049
ABSTRACT
The mechanical behaviour of regenerated bone tissue during fracture healing is key in determining its ability to withstand physiological loads. However, the strain distribution in the newly formed tissue and how this influences the way a fracture heals it is still unclear. X-ray Computed Tomography (XCT) has been extensively used to assess the progress of mineralised tissues in regeneration and when combined with in situ mechanics and digital volume correlation (DVC) has been proven a powerful tool to understand the mechanical behaviour and full-field three-dimensional (3D) strain distribution in bone. The purpose of this study is therefore to use in situ XCT mechanics and DVC to investigate the strain distribution and load-bearing capacity in a regenerating fracture in the diaphyseal bone, using a rodent femoral fracture model stabilised by external fixation. Rat femurs with 1 mm and 2 mm osteotomy gaps were tested under in situ XCT step-wise compression in the apparent elastic region. High strain was present in the newly formed bone (εp1 and εp3 reaching 29 000 µÎµ and -43 000 µÎµ, respectively), with a wide variation and inhomogeneity of the 3D strain distribution in the regenerating tissues of the fracture gap, which is directly related to the presence of unmineralised tissue observed in histological images. The outcomes of this study will contribute in understanding natural regenerative ability of bone and its mechanical behaviour under loading.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Bone and Bones / Femoral Fractures Limits: Animals Language: En Journal: J Microsc Year: 2022 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Bone and Bones / Femoral Fractures Limits: Animals Language: En Journal: J Microsc Year: 2022 Document type: Article