Fetal heart rate monitoring during fetoscopic repair of open spinal neural tube defects: a single-centre observational cohort study.
García, I; Suárez, E; Maiz, N; Pascual, M; Perera, R; Arévalo, S; Giné, C; Molino, J A; López, M; Carreras, E; Manrique, S.
Affiliation
  • García I; Anaesthesiology and Intensive Care Department. Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain; Universitat Autònoma de Barcelona, Bellaterra, Spain.
  • Suárez E; Anaesthesiology and Intensive Care Department. Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain; Universitat Autònoma de Barcelona, Bellaterra, Spain.
  • Maiz N; Universitat Autònoma de Barcelona, Bellaterra, Spain; Obstetrics Department, Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain. Electronic address: nmaiz@vhebron.net.
  • Pascual M; Anaesthesiology and Intensive Care Department. Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain; Universitat Autònoma de Barcelona, Bellaterra, Spain.
  • Perera R; Anaesthesiology and Intensive Care Department. Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain; Universitat Autònoma de Barcelona, Bellaterra, Spain.
  • Arévalo S; Universitat Autònoma de Barcelona, Bellaterra, Spain; Obstetrics Department, Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain.
  • Giné C; Universitat Autònoma de Barcelona, Bellaterra, Spain; Paediatric Surgery Department. Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus. Barcelona, Spain.
  • Molino JA; Universitat Autònoma de Barcelona, Bellaterra, Spain; Paediatric Surgery Department. Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus. Barcelona, Spain.
  • López M; Universitat Autònoma de Barcelona, Bellaterra, Spain; Paediatric Surgery Department. Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus. Barcelona, Spain.
  • Carreras E; Universitat Autònoma de Barcelona, Bellaterra, Spain; Obstetrics Department, Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain.
  • Manrique S; Anaesthesiology and Intensive Care Department. Hospital Universitari Vall d'Hebron, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain; Universitat Autònoma de Barcelona, Bellaterra, Spain.
Int J Obstet Anesth ; 48: 103195, 2021 Nov.
Article in En | MEDLINE | ID: mdl-34175576
ABSTRACT

BACKGROUND:

During fetal surgery, the haemodynamic stability of the fetus depends on the haemodynamic stability of the mother. The primary objective of this study was to assess changes in fetal heart rate (FHR) throughout the different stages of surgery. The secondary objective was to assess potential changes in maternal physiological parameters and their association with FHR.

METHODS:

This was a single-center observational cohort study conducted between 2015 and 2019 in 26 women undergoing intra-uterine fetoscopic repair of open spina bifida. The primary outcome was FHR. Maternal physiologic parameters were measured at the beginning, during and after surgery. The linear mixed-effects model fitted by maximum likelihood was used to assess changes in each variable at specific times throughout the surgery, and the repeated measures correlation coefficient was used to study the association between FHR and maternal physiological parameters.

RESULTS:

One (3.8%) case of fetal bradycardia (FHR <110 beats per minute) required the administration of intramuscular atropine. No other significant FHR changes were observed during surgery. Maternal oesophageal temperature (P <0.001), lactate levels (P=0.002), and mean arterial pressure (P=0.016) changed significantly during surgery, although none of these changes was clinically relevant. The FHR showed a significant association with maternal carbon dioxide tension (r=0.285, 95% CI 0.001 to 0.526) and maternal heart rate (r=0.302, 95% CI 0.025 to 0.535).

CONCLUSION:

The FHR remained stable during intra-uterine fetoscopic repair of open spina bifida. Maternal carbon dioxide tension and heart rate may have a mild influence on FHR.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Heart Rate, Fetal / Neural Tube Defects Type of study: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Female / Humans / Pregnancy Language: En Journal: Int J Obstet Anesth Year: 2021 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Heart Rate, Fetal / Neural Tube Defects Type of study: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Female / Humans / Pregnancy Language: En Journal: Int J Obstet Anesth Year: 2021 Document type: Article