Your browser doesn't support javascript.
loading
Dual-wavelength electrochemiluminescence ratiometry for hydrogen sulfide detection based on Cd2+-doped g-C3N4 nanosheets.
Cao, Jun-Tao; Fu, Yi-Zhuo; Fu, Xiao-Long; Ren, Shu-Wei; Liu, Yan-Ming.
Affiliation
  • Cao JT; College of Chemistry and Chemical Engineering, Xinyang Key Laboratory of Functional Nanomaterials for Bioanalysis, Xinyang Normal University, Xinyang 464000, China. liuym9518@sina.com.
  • Fu YZ; College of Chemistry and Chemical Engineering, Xinyang Key Laboratory of Functional Nanomaterials for Bioanalysis, Xinyang Normal University, Xinyang 464000, China. liuym9518@sina.com.
  • Fu XL; College of Chemistry and Chemical Engineering, Xinyang Key Laboratory of Functional Nanomaterials for Bioanalysis, Xinyang Normal University, Xinyang 464000, China. liuym9518@sina.com.
  • Ren SW; Xinyang Central Hospital, Xinyang 464000, China.
  • Liu YM; College of Chemistry and Chemical Engineering, Xinyang Key Laboratory of Functional Nanomaterials for Bioanalysis, Xinyang Normal University, Xinyang 464000, China. liuym9518@sina.com.
Analyst ; 147(2): 247-251, 2022 Jan 17.
Article in En | MEDLINE | ID: mdl-34931211
ABSTRACT
Herein, a novel and facile dual-wavelength ratiometric electrochemiluminescence-resonance energy transfer (ECL-RET) sensor for hydrogen sulfide (H2S) detection was constructed based on the interaction between S2- and Cd2+-doped g-C3N4 nanosheets (NSs). Cd2+-doped g-C3N4 NSs exhibited a strong ECL emission at 435 nm. In the presence of H2S, CdS was formed in situ on g-C3N4 NSs by the adsorption of S2- and Cd2+, generating another ECL emission at 515 nm. Furthermore, the overlapping of the absorption spectrum of the formed CdS and the ECL emission spectrum of g-C3N4 NSs led to a feasible RET, thus quenching the ECL intensity from g-C3N4 at 435 nm. Through an ECL decrease at 435 nm and an increase at 515 nm, a dual-wavelength ratiometric ECL-RET system for H2S was designed. The sensor exhibited a lower detection limit of 0.02 µM with a wide linear range of 0.05-100.0 µM. In addition, the applicability of the method was validated by plasma sample analysis with a linear range of 80.0-106.0%. We believe that such a proposal would provide new insight into advanced dual-wavelength ECL ratiometric assays.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Biosensing Techniques / Hydrogen Sulfide Type of study: Diagnostic_studies Language: En Journal: Analyst Year: 2022 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Biosensing Techniques / Hydrogen Sulfide Type of study: Diagnostic_studies Language: En Journal: Analyst Year: 2022 Document type: Article