Your browser doesn't support javascript.
loading
Chiral LC method development: Stereo-selective separation, characterization, and determination of cabotegravir and related RS, RR, and SS isomeric impurities on coated cellulose-based chiral stationary phase by HILIC-LC and LC-MS.
Krishna Murthy Kasa, S R; Venkatanarayana, Muvvala; Chennuru, Lakshmi Narayana; Chandra Sekhara Rao, B; Vemparala, Manohar; Chaman, Abdul Fareed; Talluri, M V N Kumar.
Affiliation
  • Krishna Murthy Kasa SR; Daicel Chiral Technologies (India) Pvt Ltd, IKP Knowledge Park, Shamirpet, Hyderabad 500101, India.
  • Venkatanarayana M; Department of Chemistry, GITAM school of science, GITAM (Deemed to be University), Hyderabad 502329, India. Electronic address: vmuvvala2@gitam.edu.
  • Chennuru LN; Daicel Chiral Technologies (India) Pvt Ltd, IKP Knowledge Park, Shamirpet, Hyderabad 500101, India.
  • Chandra Sekhara Rao B; Daicel Chiral Technologies (India) Pvt Ltd, IKP Knowledge Park, Shamirpet, Hyderabad 500101, India.
  • Vemparala M; Daicel Chiral Technologies (India) Pvt Ltd, IKP Knowledge Park, Shamirpet, Hyderabad 500101, India.
  • Chaman AF; Daicel Chiral Technologies (India) Pvt Ltd, IKP Knowledge Park, Shamirpet, Hyderabad 500101, India.
  • Talluri MVNK; Daicel Chiral Technologies (India) Pvt Ltd, IKP Knowledge Park, Shamirpet, Hyderabad 500101, India. Electronic address: narendra.talluri@gmail.com.
J Pharm Biomed Anal ; 222: 115062, 2023 Jan 05.
Article in En | MEDLINE | ID: mdl-36194910
ABSTRACT
The first, sensitive, and rapid chiral method was developed for enatioseperations and determination of cabotegravir and its enantiomeric impurities by using HPLC and LC-MS. Cabotegravir is an antiretroviral medication used for the treatment of HIV/AIDS approved by the food and drugs administration (FDA) in the year 2021. The cabotegravir chiral separation was achieved on the coated cellulose-tris (4-chloro-3-methyl phenyl carbamate) (CHIRALCEL OX-3R) column in HILIC mode and the total run time is less than 15 min. The effects of mobile phase composition, elution mode, and percentage of organic modifier as well as the effect of mobile phase-additives and column temperature were investigated on selectivity, resolution, and peak symmetry. The mobile phase consisted of acetonitrile and water with 0.1% (v/v) addition of formic acid additive with the flow rate of 1 mLmin-1. UV detection was carried out at 220 nm. The calibration curves of cabotegravir and its enantiomers were linear over the concentration range of 0.04-1.125 µgmL-1. The limits of detection and quantification for cabotegravir and its enantiomer (RS isomer) were ≤ 0.02 and ≤ 0.06, and the RR and SS-isomers limits were ≤ 0.02 and 0.03 µgmL-1 respectively. It was demonstrated that the proposed method is selective, precise, and robust. Finally, the validated method was applied for the determination and identification of cabotegravir and its chiral enantiomers in the bulk drugs by using HPLC and LC-MS techniques.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Cellulose / Tandem Mass Spectrometry Language: En Journal: J Pharm Biomed Anal Year: 2023 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Cellulose / Tandem Mass Spectrometry Language: En Journal: J Pharm Biomed Anal Year: 2023 Document type: Article