Accuracy and precision of the measurement of liner orientation of dual mobility cup total hip arthroplasty using ultrasound imaging.
Riglet, Louis; Viste, Anthony; De Leissègues, Tristan; Naaim, Alexandre; Liebgott, Hervé; Dumas, Raphaël; Fessy, Michel Henri; Gras, Laure-Lise.
Affiliation
  • Riglet L; Univ Lyon, Univ Gustave Eiffel, Univ Claude Bernard Lyon 1, LBMC UMR_T9406, F69622, Lyon, France.
  • Viste A; Univ Lyon, Univ Gustave Eiffel, Univ Claude Bernard Lyon 1, LBMC UMR_T9406, F69622, Lyon, France; Hospices Civils de Lyon, Hôpital Lyon Sud, Service de Chirurgie Orthopédique, 165 Chemin du Grand Revoyet, 69495 Pierre Benite Cedex, France.
  • De Leissègues T; Hospices Civils de Lyon, Hôpital Lyon Sud, Service de Chirurgie Orthopédique, 165 Chemin du Grand Revoyet, 69495 Pierre Benite Cedex, France.
  • Naaim A; Univ Lyon, Univ Gustave Eiffel, Univ Claude Bernard Lyon 1, LBMC UMR_T9406, F69622, Lyon, France.
  • Liebgott H; CREATIS, Univ Lyon, INSA Lyon, UCBL, UJM Saint-Étienne, CNRS UMR 5220, Inserm U1294, Lyon, France.
  • Dumas R; Univ Lyon, Univ Gustave Eiffel, Univ Claude Bernard Lyon 1, LBMC UMR_T9406, F69622, Lyon, France.
  • Fessy MH; Univ Lyon, Univ Gustave Eiffel, Univ Claude Bernard Lyon 1, LBMC UMR_T9406, F69622, Lyon, France; Hospices Civils de Lyon, Hôpital Lyon Sud, Service de Chirurgie Orthopédique, 165 Chemin du Grand Revoyet, 69495 Pierre Benite Cedex, France.
  • Gras LL; Univ Lyon, Univ Gustave Eiffel, Univ Claude Bernard Lyon 1, LBMC UMR_T9406, F69622, Lyon, France. Electronic address: laure-lise.gras@univ-lyon1.fr.
Med Eng Phys ; 108: 103877, 2022 10.
Article in En | MEDLINE | ID: mdl-36195356
ABSTRACT
The Dual Mobility Cup (DMC) was created in 1974 to prevent dislocation and decrease wear. However, the movement of the polyethylene liner in vivo remains unclear. The aims of this study were to visualise liner positions and quantify the accuracy of the liner plane orientation for static positions, using ultrasound imaging. DMC reconstruction and angle between cup and liner were evaluated on isolated submerged DMCs by comparing 3D laser scans and ultrasound imaging. Moreover, the abduction and anteversion angles of the liner plane relative to the pelvis orientation were calculated via combined motion analysis and 3D ultrasound imaging on four fresh post-mortem human subjects with implanted DMC. On submerged DMC, the mean angle error between ultrasound imaging and 3D scan was 1.2°. In cadaveric experiments, intra-operator repeatability proved satisfactory, with low range value (lower than 2°) and standard deviation (lower than 1°). The study demonstrates the feasibility of measuring liner orientation on submerged and ex vivo experiments using ultrasound imaging, and is a first step towards in vivo analysis of DMC movement.