Substitution with Low-Osmolar Iodinated Contrast Agent to Minimize Recurrent Immediate Hypersensitivity Reaction.
Radiology
; 309(1): e222467, 2023 10.
Article
in En
| MEDLINE
| ID: mdl-37906013
ABSTRACT
Background The recurrence of hypersensitivity reaction (HSR) to low-osmolar iodinated contrast media (LOCM) remains challenging despite premedication and substitution of the LOCM. Purpose To determine the optimal practical preventive strategy for LOCM substitution in patients with a history of prior immediate HSR to LOCM. Materials and Methods In a retrospective study, patients with an immediate HSR to LOCM before February 2020 and who underwent subsequent exposure to LOCM until March 2021 were enrolled in five tertiary referral hospitals in South Korea. The association of recurrence of an HSR after subsequent LOCM exposures was assessed using multivariate general estimating equation analysis according to age, sex, the severity of the index HSR, premedication, and substituting LOCM based on common carbamoyl side chains, including the N-(2,3-dihydroxypropyl)-carbamoyl and N-(2,3-dihydroxypropyl)-N-methyl-carbamoyl moieties. Results The evaluation included 3800 subsequent LOCM exposures in 1066 patients (mean age, 56.2 years ± 13.5 [SD]; 567 [53%] female and 499 [47%] male patients). The general estimating equation analysis, using 11 propensity score matched data for age, sex, HSR severity, and LOCM selection, showed that premedication with corticosteroids significantly reduced recurrent HSR (odds ratio [OR], 0.72; 95% CI 0.52, 1.00; P = .049). The change to another LOCM with a common side chain had a similar recurrence rate as using the same LOCM (OR, 0.98; 95% CI 0.64, 1.50; P = .93), whereas the use of a different LOCM without a common side chain significantly lowered HSR recurrence (OR, 0.51; 95% CI 0.37, 0.69; P < .001) in multivariate general estimating equation analysis. Substitution of an LOCM without a common side chain was effective regardless of the index HSR severity but was more pronounced in moderate-to-severe reactions (OR, 0.30; 95% CI 0.16, 0.55; P < .001). Conclusion For patients with a previous immediate HSR of any severity to LOCM, alternative LOCM without a common carbamoyl side chain reduced recurrent HSR during subsequent exposures. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by McDonald in this issue.
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Hypersensitivity
/
Hypersensitivity, Immediate
Limits:
Female
/
Humans
/
Male
/
Middle aged
Language:
En
Journal:
Radiology
Year:
2023
Document type:
Article