Your browser doesn't support javascript.
loading
m-PIMA™ HIV1/2 VL: A suitable tool for HIV-1 and HIV-2 viral load quantification in West Africa.
Diop-Ndiaye, Halimatou; Sène, Pauline Yacine; Coulibaly, Khadidiatou; Diallo, Marième; Diallo, Sada; Diop, Karim; Sow-Ndoye, Aissatou; Fall, Mengue; Ndiaye, Anna Julienne Selbe; Mathebula, Evans; Ba, Adjratou Aissatou; Lejeune, Charlotte; Manga, Ndeye Marie Pascaline; Camara, Makhtar; Ndour, Cheikh Tidiane; Kane, Coumba Toure.
Affiliation
  • Diop-Ndiaye H; Cheikh Anta Diop University and Bacteriology-Virology UTH Aristide le Dantec, Dakar, Senegal. Electronic address: halimatoudiop@yahoo.fr.
  • Sène PY; Bacteriology-Virology UTH Aristide le Dantec, Dakar, Senegal.
  • Coulibaly K; Division de Lutte contre le SIDA/IST, Dakar, Senegal.
  • Diallo M; Clinton Health Access Initiative, Dakar, Senegal.
  • Diallo S; Bacteriology-Virology UTH Aristide le Dantec, Dakar, Senegal.
  • Diop K; Division de Lutte contre le SIDA/IST, Dakar, Senegal.
  • Sow-Ndoye A; Institut de Recherche en Santé, de surveillance épidémiologique et de Formation, Dakar, Senegal.
  • Fall M; Bacteriology-Virology UTH Aristide le Dantec, Dakar, Senegal.
  • Ndiaye AJS; Institut de Recherche en Santé, de surveillance épidémiologique et de Formation, Dakar, Senegal.
  • Mathebula E; School of Health Systems and Public Health, Faculty of Health Science, University of Pretoria, Pretoria, South Africa.
  • Ba AA; Bacteriology-Virology UTH Aristide le Dantec, Dakar, Senegal.
  • Lejeune C; Clinton Health Access Initiative, Dakar, Senegal.
  • Manga NMP; Bacteriology-Virology UTH Aristide le Dantec, Dakar, Senegal.
  • Camara M; Cheikh Anta Diop University and Bacteriology-Virology UTH Aristide le Dantec, Dakar, Senegal.
  • Ndour CT; Division de Lutte contre le SIDA/IST, Dakar, Senegal.
  • Kane CT; Institut de Recherche en Santé, de surveillance épidémiologique et de Formation, Dakar, Senegal.
J Virol Methods ; 324: 114872, 2024 Feb.
Article in En | MEDLINE | ID: mdl-38128833
ABSTRACT
Point-of-Care for HIV viral RNA quantification seems to be a complementary strategy to the existing conventional systems. This study evaluated the performance of the m-PIMA™ HIV1/2 Viral Load for the quantification of both HIV-1 and HIV-2 RNA viral load. A total of 555 HIV-1 and 90 HIV-2 samples previously tested by Abbott RealTime HIV-1 (Abbott, Chicago, USA) and Generic HIV-2® Charge virale (Biocentric, France) were tested using the m-PIMA™ HIV1/2 Viral Load at the HIV National Reference lab in Senegal. For HIV-1, Pearson correlation and Bland-Altman plots showed a coefficient r = 0.97 and a bias of -0.11 log10 copies/ml (95% confidence interval [CI] -0.086 to -0.133 log10 copies/ml) for the m-PIMA™ HIV1/2 Viral Load, respectively. Sensitivity and specificity at 3 log10 copies/ml (threshold of virological failure) were 93.6% (95%[CI] 91.5% to 95.6%) and 99.1% (95%[CI] 98.3% to 99.9%), respectively. For HIV-2, a correlation of r = 0.95 was also noted with a bias of - 0.229 log10 copies/ml (95%[CI] -0.161 to -0.297 log10 copies/ml). Sensitivity and specificity at 3 log10 copies/ml were 97.6% (95%[CI] 94.3% to 100%) and 93.9% (95%[CI] 88.9% to 98.8%), respectively. These results confirmed that m-PIMA™ HIV1/2 VL could be a good alternative for HIV-1 and HIV-2 viral load testing in decentralized settings in Senegal.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: HIV Infections / HIV-1 Limits: Humans Country/Region as subject: Africa Language: En Journal: J Virol Methods Year: 2024 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: HIV Infections / HIV-1 Limits: Humans Country/Region as subject: Africa Language: En Journal: J Virol Methods Year: 2024 Document type: Article