Central Vein Sign in Multiple Sclerosis: A Comparison Study of the Diagnostic Performance of 3T versus 7T MRI.
Okromelidze, Lela; Patel, Vishal; Singh, Rahul B; Lopez Chiriboga, Alfonso S; Tao, Shengzhen; Zhou, Xiangzhi; Straub, Sina; Westerhold, Erin M; Gupta, Vivek; Agarwal, Amit K; Murray, John V; Desai, Amit; Sandhu, S J S; Marin Collazo, I Vanessa; Middlebrooks, Erik H.
Affiliation
  • Okromelidze L; From the Departments of Radiology (L.O., V.P., R.B.S., S.T., X.Z., S.S., E.M.W., V.G., A.K.A., J.V.M., A.D., S.J.S.S., E.H.M.), Mayo Clinic, Jacksonville, Florida.
  • Patel V; From the Departments of Radiology (L.O., V.P., R.B.S., S.T., X.Z., S.S., E.M.W., V.G., A.K.A., J.V.M., A.D., S.J.S.S., E.H.M.), Mayo Clinic, Jacksonville, Florida.
  • Singh RB; From the Departments of Radiology (L.O., V.P., R.B.S., S.T., X.Z., S.S., E.M.W., V.G., A.K.A., J.V.M., A.D., S.J.S.S., E.H.M.), Mayo Clinic, Jacksonville, Florida.
  • Lopez Chiriboga AS; Neurology (A.S.L.C., I.V.M.C.), Mayo Clinic, Jacksonville, Florida.
  • Tao S; From the Departments of Radiology (L.O., V.P., R.B.S., S.T., X.Z., S.S., E.M.W., V.G., A.K.A., J.V.M., A.D., S.J.S.S., E.H.M.), Mayo Clinic, Jacksonville, Florida.
  • Zhou X; From the Departments of Radiology (L.O., V.P., R.B.S., S.T., X.Z., S.S., E.M.W., V.G., A.K.A., J.V.M., A.D., S.J.S.S., E.H.M.), Mayo Clinic, Jacksonville, Florida.
  • Straub S; From the Departments of Radiology (L.O., V.P., R.B.S., S.T., X.Z., S.S., E.M.W., V.G., A.K.A., J.V.M., A.D., S.J.S.S., E.H.M.), Mayo Clinic, Jacksonville, Florida.
  • Westerhold EM; From the Departments of Radiology (L.O., V.P., R.B.S., S.T., X.Z., S.S., E.M.W., V.G., A.K.A., J.V.M., A.D., S.J.S.S., E.H.M.), Mayo Clinic, Jacksonville, Florida.
  • Gupta V; From the Departments of Radiology (L.O., V.P., R.B.S., S.T., X.Z., S.S., E.M.W., V.G., A.K.A., J.V.M., A.D., S.J.S.S., E.H.M.), Mayo Clinic, Jacksonville, Florida.
  • Agarwal AK; From the Departments of Radiology (L.O., V.P., R.B.S., S.T., X.Z., S.S., E.M.W., V.G., A.K.A., J.V.M., A.D., S.J.S.S., E.H.M.), Mayo Clinic, Jacksonville, Florida.
  • Murray JV; From the Departments of Radiology (L.O., V.P., R.B.S., S.T., X.Z., S.S., E.M.W., V.G., A.K.A., J.V.M., A.D., S.J.S.S., E.H.M.), Mayo Clinic, Jacksonville, Florida.
  • Desai A; From the Departments of Radiology (L.O., V.P., R.B.S., S.T., X.Z., S.S., E.M.W., V.G., A.K.A., J.V.M., A.D., S.J.S.S., E.H.M.), Mayo Clinic, Jacksonville, Florida.
  • Sandhu SJS; From the Departments of Radiology (L.O., V.P., R.B.S., S.T., X.Z., S.S., E.M.W., V.G., A.K.A., J.V.M., A.D., S.J.S.S., E.H.M.), Mayo Clinic, Jacksonville, Florida.
  • Marin Collazo IV; Neurology (A.S.L.C., I.V.M.C.), Mayo Clinic, Jacksonville, Florida.
  • Middlebrooks EH; From the Departments of Radiology (L.O., V.P., R.B.S., S.T., X.Z., S.S., E.M.W., V.G., A.K.A., J.V.M., A.D., S.J.S.S., E.H.M.), Mayo Clinic, Jacksonville, Florida middlebrooks.erik@mayo.edu.
AJNR Am J Neuroradiol ; 45(1): 76-81, 2023 12 29.
Article in En | MEDLINE | ID: mdl-38164557
ABSTRACT
BACKGROUND AND

PURPOSE:

An early and accurate diagnosis of multiple sclerosis remains challenging in clinical neurology. Established diagnostic methods have less than desirable sensitivity and specificity. An accurate, noninvasive diagnostic test for MS could have a major impact on diagnostic criteria. We compared the frequency of detection of the central vein sign (CVS) in white matter lesions of MS and controls on 7T T2*-weighted and SWI to 3T SWI. Additionally, we assessed the diagnostic performance of 7T T2*, 7T SWI, and 3T SWI for MS. MATERIALS AND

METHODS:

A retrospective case-control study was performed of patients with MS having both 7T MRI and 3T MRI. A control group of patients without MS was selected. Diagnosis of MS was established by board-certified neurologists with fellowship training in autoimmune neurology in line with the 2017 McDonald criteria. Percentage of lesions with a CVS was blindly measured for each technique. Diagnostic performance was computed by sensitivity, specificity, and positive and negative likelihood ratios (LRs).

RESULTS:

Sixty-one patients with MS (903 lesions) and 39 controls (1088 lesions) were included. 7T T2* showed significantly more CVS (87%) than both 7T SWI (73%) and 3T SWI (31%) (all P < .001). CVS was identified in the control group in ≤6% of lesions on all sequences. Using a threshold of >40% of lesions with CVS on 7T T2* and >15% on 7T SWI, both sequences had an accuracy = 100%, sensitivity = 100%, specificity = 100%, infinite positive LR, and zero negative LR. Using an optimal threshold of >12%, 3T SWI had an accuracy = 96.0%, sensitivity = 93.4%, specificity = 100%, infinite positive LR, and negative LR = 0.066.

CONCLUSIONS:

7T MRI had 100% sensitivity and specificity for the diagnosis of MS and is superior to 3T. Future revisions to MS diagnostic criteria may consider recommendations for 7T MRI and inclusion of CVS as a biomarker.