Your browser doesn't support javascript.
loading
Discrepancies in MR- and CT-Based Femoral Version Measurements Despite Strong Correlations.
Zhang, Siqi; Liu, Ke; Gao, Guanying; Lang, Ning; Xu, Yan.
Affiliation
  • Zhang S; Department of Sports Medicine, Institute of Sports Medicine of Peking University, Peking University Third Hospital, Beijing, China; Beijing Key Laboratory of Sports Injuries, Beijing, China; Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing
  • Liu K; Department of Radiology, Peking University Third Hospital, Beijing, China.
  • Gao G; Department of Sports Medicine, Institute of Sports Medicine of Peking University, Peking University Third Hospital, Beijing, China; Beijing Key Laboratory of Sports Injuries, Beijing, China; Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing
  • Lang N; Department of Radiology, Peking University Third Hospital, Beijing, China.
  • Xu Y; Department of Sports Medicine, Institute of Sports Medicine of Peking University, Peking University Third Hospital, Beijing, China; Beijing Key Laboratory of Sports Injuries, Beijing, China; Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing
Arthroscopy ; 2024 Jan 03.
Article in En | MEDLINE | ID: mdl-38181987
ABSTRACT

PURPOSE:

To determine the correlation and classification consistency of femoral version measurements between magnetic resonance (MR) and computed tomography (CT) using 4 commonly used measurement methods.

METHODS:

A retrospective study was performed on patients with femoroacetabular impingement (FAI) who received preoperative CT and MR imaging assessment of the surgical hip and ipsilateral distal femur. Femoral version was measured using the Murphy method, the oblique method, the Reikerås method, and the Lee method. Intra- and inter-rater agreements were calculated. Linear regression and Bland-Altman analysis were performed for measurements using different imaging modalities and measurement methods. Femoral version measurements within the lower quartile, the middle 2 quartiles, and the upper quartile were classified into different groups based on their percentile within the sample population. Classification consistency rates between modalities and methods were calculated and compared.

RESULTS:

Fifty-three patients (39.4 ± 9.1 years; 32 female) were included for analysis. Intra- and inter-rater reliability were high for all modalities and methods (intrarater intraclass correlation coefficient [ICC] range, 0.963-0.993; inter-rater ICC range, 0.871-0.960). MR- and CT-based femoral version measurements showed strong correlations for all methods, with the Lee method demonstrating the strongest association (r = 0.904), while the oblique method exhibited the lowest correlation (r = 0.684) (all P < .001). MR-based measurements were smaller than CT-based measurements, with mean differences ranging from 4.5° to 10.3°. Classification consistency between MR and CT ranged from 51% to 74%, whereas the consistency between different measurement methods ranged from 68% to 85%.

CONCLUSIONS:

While strong correlations were observed between MR- and CT-based femoral version measurements, MR-based measurements were significantly smaller than their CT counterparts. Classification consistency between the modalities was moderate to high. Measurements between different methods showed strong correlations with high consistency rates. LEVEL OF EVIDENCE Level III, retrospective case series.

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Observational_studies / Risk_factors_studies Language: En Journal: Arthroscopy Year: 2024 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Observational_studies / Risk_factors_studies Language: En Journal: Arthroscopy Year: 2024 Document type: Article