Protecting the Antibacterial Coating of Urinal Catheters for Improving Safety.
Perelshtein, Ilana; Shoshani, Sivan; Jacobi, Gila; Natan, Michal; Dudchenko, Nataliia; Perkas, Nina; Tkachev, Maria; Bengalli, Rossella; Fiandra, Luisa; Mantecca, Paride; Ivanova, Kristina; Tzanov, Tzanko; Banin, Ehud; Gedanken, Aharon.
Affiliation
  • Perelshtein I; Department of Chemistry, Bar-Ilan University, Ramat-Gan 5290002, Israel.
  • Shoshani S; Institute of Nanotechnology and Advanced Materials (BINA), Bar-Ilan University, Ramat-Gan 5290002, Israel.
  • Jacobi G; The Mina and Everard Goodman Faculty of Life Sciences, Institute of Nanotechnology and Advanced Materials (BINA), Bar-Ilan University, Ramat-Gan 5290002, Israel.
  • Natan M; The Mina and Everard Goodman Faculty of Life Sciences, Institute of Nanotechnology and Advanced Materials (BINA), Bar-Ilan University, Ramat-Gan 5290002, Israel.
  • Dudchenko N; The Mina and Everard Goodman Faculty of Life Sciences, Institute of Nanotechnology and Advanced Materials (BINA), Bar-Ilan University, Ramat-Gan 5290002, Israel.
  • Perkas N; Institute of Nanotechnology and Advanced Materials (BINA), Bar-Ilan University, Ramat-Gan 5290002, Israel.
  • Tkachev M; Department of Chemistry, Bar-Ilan University, Ramat-Gan 5290002, Israel.
  • Bengalli R; Institute of Nanotechnology and Advanced Materials (BINA), Bar-Ilan University, Ramat-Gan 5290002, Israel.
  • Fiandra L; Institute of Nanotechnology and Advanced Materials (BINA), Bar-Ilan University, Ramat-Gan 5290002, Israel.
  • Mantecca P; Department of Earth and Environmental Sciences, Research Center POLARIS, University of Milano Bicocca, Milan 20126, Italy.
  • Ivanova K; Department of Earth and Environmental Sciences, Research Center POLARIS, University of Milano Bicocca, Milan 20126, Italy.
  • Tzanov T; Department of Earth and Environmental Sciences, Research Center POLARIS, University of Milano Bicocca, Milan 20126, Italy.
  • Banin E; Grup de Biotecnologia Molecular i Industrial, Department of Chemical Engineering, Universitat Politècnica de Catalunya, Rambla Sant Nebridi 22, 08222 Terrasa, Spain.
  • Gedanken A; Grup de Biotecnologia Molecular i Industrial, Department of Chemical Engineering, Universitat Politècnica de Catalunya, Rambla Sant Nebridi 22, 08222 Terrasa, Spain.
ACS Appl Bio Mater ; 7(2): 990-998, 2024 02 19.
Article in En | MEDLINE | ID: mdl-38226433
ABSTRACT
Catheter-associated urinary tract infections (CAUTI) are among the most common bacterial infections associated with prolonged hospitalization and increased healthcare expenditures. Despite recent advances in the prevention and treatment of these infections, there are still many challenges remaining, among them the creation of a durable catheter coating, which prevents bacterial biofilm formation. The current work reports on a method of protecting medical tubing endowed with antibiofilm properties. Silicone catheters coated sonochemically with ZnO nanoparticles (NPs) demonstrated excellent antibiofilm effects. Toward approval by the European Medicines Agency, it was realized that the ZnO coating would not withstand the regulatory requirements of avoiding dissolution for 14 days in artificial urine examination. Namely, after exposure to urine for 14 days, the coating amount was reduced by 90%. Additional coatings with either carbon or silica maintained antibiofilm activity against Staphylococcus aureus while resisting dissolution in artificial urine for 14 days (C- or SiO2-protected catheters exhibited only 29% reduction). HR-SEM images of the protected catheters indicate the presence of the ZnO coating as well as the protective layer. Antibiofilm activity of all catheters was evaluated both before and after exposure to artificial urine. It was shown that before artificial urine exposure, all coated catheters showed high antibiofilm properties compared to the uncoated control. Exposure of ZnO-coated catheters, without the protective layer, to artificial urine had a significant effect exhibited by the decrease in antibiofilm activity by almost 2 orders of magnitude, compared to unexposed catheters. Toxicity studies performed using a reconstructed human epidermis demonstrated the safety of the improved coating. Exposure of the epidermis to ZnO catheter extracts in artificial urine affects tissue viability compared with control samples, which was not observed in the case of ZnO NPs coating with SiO2 or C. We suggest that silica and carbon coatings confer some protection against zinc ions release, improving ZnO coating safety.