Your browser doesn't support javascript.
loading
One-year Outcomes of Ultrathin Descemet Stripping Automated Endothelial Keratoplasty Combined with Cataract Surgery in the Korean Population.
Koo, Minjeong Ashley; Yoon, Hye Yeon; Park, Jae Hyun; Chung, So-Hyang; Kim, Hyun-Seung; Byun, Yong-Soo.
Affiliation
  • Koo MA; Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Yoon HY; Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Park JH; Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Chung SH; Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Kim HS; Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Byun YS; Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Korean J Ophthalmol ; 38(2): 105-112, 2024 Apr.
Article in En | MEDLINE | ID: mdl-38351485
ABSTRACT

PURPOSE:

To evaluate the refractive outcomes after ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) combined with phacoemulsification and intraocular lens implantation (triple procedure) in the South Korean population.

METHODS:

This retrospective observational study included 37 eyes of 36 patients who underwent the UT-DSAEK triple procedure between 2012 and 2021 in a single tertiary hospital. Preoperative and postoperative refractive outcomes and endothelial parameters at 1, 3, 6, and 12 months were observed.

RESULTS:

At the final postoperative 12-month period, the average best-corrected visual acuity was 0.4 ± 0.5 in logarithm of the minimum angle of resolution. The mean endothelial cell density at 12 months was 1,841.92 ± 731.24 cells/mm2, indicating no significant endothelial cell loss compared to the baseline (p = 0.128). The mean postoperative central corneal thickness at 12 months was 597.41 ± 86.26 µm. The postoperative mean absolute error at 12 months was 0.96 ± 0.89 diopters (D) and mean error was 0.89 ± 0.97 D.

CONCLUSIONS:

The results of our South Korean cohort study on UT-DSAEK triple surgery showed favorable and safe outcomes. Regardless of graft thickness, it should be noted that a hyperopic shift of 1.00 to 2.00 D needs to be considered in the case of UT-DSAEK triple surgery.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Cataract / Fuchs' Endothelial Dystrophy / Corneal Transplantation / Descemet Stripping Endothelial Keratoplasty Type of study: Observational_studies Limits: Humans Language: En Journal: Korean J Ophthalmol Year: 2024 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Cataract / Fuchs' Endothelial Dystrophy / Corneal Transplantation / Descemet Stripping Endothelial Keratoplasty Type of study: Observational_studies Limits: Humans Language: En Journal: Korean J Ophthalmol Year: 2024 Document type: Article