Your browser doesn't support javascript.
loading
Robotic-assisted burring in total hip replacement: A new surgical technique to optimise acetabular preparation.
Li, Tiancheng; Walker, Peter; Khonasty, Richardo; van de Graaf, Victor A; Yelf, Eric; Zhao, Liang; Huang, Shoudong.
Affiliation
  • Li T; Robotics Institute, Faculty of Engineering and Information Technology, University of Technology Sydney (UTS), Sydney, New South Wales, Australia.
  • Walker P; Concord Repatriation General Hospital, Concord, New South Wales, Australia.
  • Khonasty R; Robotics Institute, Faculty of Engineering and Information Technology, University of Technology Sydney (UTS), Sydney, New South Wales, Australia.
  • van de Graaf VA; Concord Repatriation General Hospital, Concord, New South Wales, Australia.
  • Yelf E; Concord Repatriation General Hospital, Concord, New South Wales, Australia.
  • Zhao L; Robotics Institute, Faculty of Engineering and Information Technology, University of Technology Sydney (UTS), Sydney, New South Wales, Australia.
  • Huang S; Robotics Institute, Faculty of Engineering and Information Technology, University of Technology Sydney (UTS), Sydney, New South Wales, Australia.
Int J Med Robot ; 20(1): e2615, 2024 Feb.
Article in En | MEDLINE | ID: mdl-38536714
ABSTRACT

BACKGROUND:

In Total Hip replacement (THR) surgery, a critical step is to cut an accurate hemisphere into the acetabulum so that the component can be fitted accurately and obtain early stability. This study aims to determine whether burring rather than reaming the acetabulum can achieve greater accuracy in the creation of this hemisphere.

METHODS:

A preliminary robotic system was developed to demonstrate the feasibility of burring the acetabulum using the Universal Robot (UR10). The study will describe mechanical design, robot trajectory optimisation, control algorithm development, and results from phantom experiments compared with both robotic reaming and conventional reaming. The system was also tested in a cadaver experiment.

RESULTS:

The proposed robotic burring system can produce a surface in 2 min with an average error of 0.1 and 0.18 mm, when cutting polyurethane bone block #15 and #30, respectively. The performance was better than robotic reaming and conventional hand reaming.

CONCLUSION:

The proposed robotic burring system outperformed robotic and conventional reaming methods to produce an accurate acetabular cavity. The findings show the potential usage of a robotic-assisted burring in THR for acetabular preparation.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Robotics / Arthroplasty, Replacement, Hip / Robotic Surgical Procedures / Hip Prosthesis Limits: Humans Language: En Journal: Int J Med Robot / Int. j. med. robot. comput. assist. surg / International journal of medical robotics / computer assisted surgery Year: 2024 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Robotics / Arthroplasty, Replacement, Hip / Robotic Surgical Procedures / Hip Prosthesis Limits: Humans Language: En Journal: Int J Med Robot / Int. j. med. robot. comput. assist. surg / International journal of medical robotics / computer assisted surgery Year: 2024 Document type: Article