Liquid chromatography with tandem mass spectrometric method for determination of 52 antibiotics in human whole blood and urine and application to forensic cases.
Shi, Qianwen; Wang, Gege; Wang, Shuhui; Zhang, Chao; Wei, Zhiwen; Guo, Zhongyuan; Zhang, Dan; Yun, Keming; Fu, Shanlin.
Affiliation
  • Shi Q; School of Forensic Medicine, Shanxi Medical University, Taiyuan, 030001, China.
  • Wang G; Shanxi Key Laboratory of Forensic Medicine, Shanxi, 030600, China.
  • Wang S; School of Forensic Medicine, Shanxi Medical University, Taiyuan, 030001, China.
  • Zhang C; Shanxi Key Laboratory of Forensic Medicine, Shanxi, 030600, China.
  • Wei Z; School of Forensic Medicine, Shanxi Medical University, Taiyuan, 030001, China.
  • Guo Z; Shanxi Key Laboratory of Forensic Medicine, Shanxi, 030600, China.
  • Zhang D; School of Forensic Medicine, Shanxi Medical University, Taiyuan, 030001, China.
  • Yun K; Shanxi Key Laboratory of Forensic Medicine, Shanxi, 030600, China.
  • Fu S; School of Forensic Medicine, Shanxi Medical University, Taiyuan, 030001, China.
Forensic Toxicol ; 42(2): 202-211, 2024 Jul.
Article in En | MEDLINE | ID: mdl-38642241
ABSTRACT

PURPOSE:

A rapid and reliable method was developed and validated for the simultaneous analysis of 52 antibiotics (cephalosporins, penicillins, carbapenems, lincosamides, quinolones, nitroimidazoles, macrolides, sulfonamides, tetracyclines, glycopeptide) in urine and whole blood by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS).

METHOD:

Analytes were extracted by dilution or protein precipitation and analyzed on an Agilent 1260 HPLC system coupled to an Agilent 6470 Triple Quadrupole Mass Spectrometer.

RESULTS:

The method attended method validation criteria. The limits of detection were equal or lower than 2.0 ng/mL, whereas the limits of quantification ranged from 0.1 to 10.0 ng/mL, from 0.1 to 5.0 ng/mL, in urine and whole blood, respectively. For all analytes, the bias and intra- and inter-day precision values were less than 14.7%. The ranges of recovery values of all antibiotics were 76.5-124.5% in whole blood and 76.3-121.8% in urine, values of the effects were lower than 25% in two matrices. No evidence of carryover was observed. The study of sample stability showed that almost all analytes were stable at 24 °C for 24 h, all analytes were stable at -20 °C for 14 days and at -80 °C for 30 days. Freeze-thaw cycles stability showed that antibiotics were stable except for imipenem. Autosampler stability study showed that all analytes were stable for 24 h, except for imipenem and amoxicillin. Applicability was proven by analyzing authentic whole blood (n = 86) and urine (n = 79) samples from patients under antibiotics treatment. Therefore, this method was applied to the analysis 3 forensic allergy cases, which were positive for at least one analyte.

CONCLUSIONS:

A simple, sensitive and high-throughput method for the simultaneous determination of different classes of antibiotics in urine and whole blood samples was developed and applied. This sensitive method was successfully applied to forensic cases.