Your browser doesn't support javascript.
loading
Electrolyte-gated amorphous IGZO transistors with extended gates for prostate-specific antigen detection.
Yin, Xuemei; Ji, Xingqi; Liu, Wenlong; Li, Xiaoqian; Wang, Mingyang; Xin, Qian; Zhang, Jiawei; Yan, Zhuocheng; Song, Aimin.
Affiliation
  • Yin X; School of Integrated Circuits, Shandong University, Jinan 250100, China. yanzhuocheng@sdu.edu.cn.
  • Ji X; School of Integrated Circuits, Shandong University, Jinan 250100, China. yanzhuocheng@sdu.edu.cn.
  • Liu W; School of Integrated Circuits, Shandong University, Jinan 250100, China. yanzhuocheng@sdu.edu.cn.
  • Li X; School of Integrated Circuits, Shandong University, Jinan 250100, China. yanzhuocheng@sdu.edu.cn.
  • Wang M; School of Integrated Circuits, Shandong University, Jinan 250100, China. yanzhuocheng@sdu.edu.cn.
  • Xin Q; School of Integrated Circuits, Shandong University, Jinan 250100, China. yanzhuocheng@sdu.edu.cn.
  • Zhang J; State Key Laboratory of Crystal Materials, Institute of Novel Semiconductors, Shandong University, Jinan 250100, China.
  • Yan Z; School of Integrated Circuits, Shandong University, Jinan 250100, China. yanzhuocheng@sdu.edu.cn.
  • Song A; School of Integrated Circuits, Shandong University, Jinan 250100, China. yanzhuocheng@sdu.edu.cn.
Lab Chip ; 24(13): 3284-3293, 2024 06 25.
Article in En | MEDLINE | ID: mdl-38847194
ABSTRACT
The prostate-specific antigen (PSA) test is considered an important way for preoperative diagnosis and accurate screening of prostate cancer. Current antigen detection methods, including radioimmunoassay, enzyme-linked immunosorbent assay and microfluidic electrochemical detection, feature expensive equipment, long testing time and poor stability. Here, we propose a portable biosensor composed of electrolyte-gated amorphous indium gallium zinc oxide (a-IGZO) transistors with an extended gate, which can achieve real-time, instant PSA detection at a low operating voltage (<2 V) owing to the liquid-free ionic conductive elastomer (ICE) serving as the gate dielectric. The electric double layer (EDL) capacitance in ICE enhances the accumulation of carriers in the IGZO channel, leading to strong gate modulation, which enables the IGZO transistor to have a small subthreshold swing (<0.5 V dec-1) and a high on-state current (∼4 × 10-4 A). The separate, biodegradable, and pluggable sensing pad, serving as an extended gate connected to the IGZO transistor, prevents contamination and depletion arising from direct contact with biomolecular buffers, enabling the IGZO transistor to maintain superior electronic performance for at least six months. The threshold voltage and channel current of the transistor exhibit excellent linear response to PSA molecule concentrations across five orders of magnitude ranging from 1 fg mL-1 to 10 pg mL-1, with a detection limit of 400 ag mL-1 and a detection time of ∼5.1 s. The fabricated biosensors offer a point-of-care system for antigen detection, attesting the feasibility of the electrolyte-gated transistors in clinical screening, healthcare diagnostics and biological management.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Transistors, Electronic / Zinc Oxide / Biosensing Techniques / Prostate-Specific Antigen / Electrolytes / Gallium Limits: Humans / Male Language: En Journal: Lab Chip Year: 2024 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Transistors, Electronic / Zinc Oxide / Biosensing Techniques / Prostate-Specific Antigen / Electrolytes / Gallium Limits: Humans / Male Language: En Journal: Lab Chip Year: 2024 Document type: Article