Your browser doesn't support javascript.
loading
A novel micro-capillary discharge plasma jet triggered gas switch.
Chen, L; Zhang, W; Tian, S; Zhang, Q; Cao, H; Li, X; Zhang, B; Zhang, F; Wei, Y; Liu, Y.
Affiliation
  • Chen L; State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an, China.
  • Zhang W; State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an, China.
  • Tian S; State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an, China.
  • Zhang Q; State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an, China.
  • Cao H; State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an, China.
  • Li X; State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an, China.
  • Zhang B; State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an, China.
  • Zhang F; State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an, China.
  • Wei Y; State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an, China.
  • Liu Y; State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an, China.
Rev Sci Instrum ; 95(8)2024 Aug 01.
Article in En | MEDLINE | ID: mdl-39101786
ABSTRACT
To reduce the working coefficient and jitter of the three-electrode gas switch used in linear transformer drivers, a novel trigger method that uses a nanosecond pulse in cooperation with the microplasma jet generated by capillary discharge was developed. A microplasma jet was generated by the nanosecond trigger pulse and injected into the follow-up breakdown gap of the gas switch to decrease the working coefficient. The influence of capillary parameters on the development of the microplasma jet was simulated. The results showed that the microplasma jet significantly reduced the breakdown delay time, jitter, and working coefficient. Increasing the capillary length and decreasing the diameter results in better triggered breakdown performance. Furthermore, the gas switch triggered by a positive pulse exhibits a lower breakdown delay and jitter. Combined with the intensified charge coupled device's shooting results, it can be concluded that the microplasma jet has a distinct influence on streamer formation, which is important for improving the working performance of the gas switch.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Rev Sci Instrum Year: 2024 Document type: Article